Skip to main content
Top
Published in: International Orthopaedics 11/2016

01-11-2016 | Original Paper

Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases

Authors: Saverio Affatato, Saverio Comitini, Matteo Fosco, Aldo Toni, Domenico Tigani

Published in: International Orthopaedics | Issue 11/2016

Login to get access

Abstract

Introduction

Since 1979 the number of patients treated with femoral stems has continued to grow, as well as the number of stems with features similar to the Zweymüller prosthesis produced by different companies. Identification can be problematic in case requiring revision. In the present paper, we present an overview of morphometric differences between the different stem designs, which can be useful for radiologic identification in revision cases.

Methods

By doing some research on the Internet of specialized sites and worldwide literature, we searched for all femoral stems agreeing with Zweymüller principles (cementless, straight, tapered, rectangular cross-sectioned femoral stems).

Results

We found 26 different stems from different companies producing or having produced in the past the Zweymüller-type femoral stems for hip prosthesis.

Discussion

Accurate preoperative identification of the Zweymüller femoral stem type may be of critical importance to eventual outcomes following revision surgery. Each manufacturer has different instruments specific to the removal of their primary implants, and ensuring they are available can simplify the revision procedure significantly. Exact pre-operative planning is also necessary for selecting the correct ball head in cases where a stem is well-fixed and can be left in situ. The commonly used notation "Eurocone 12/14" provides no information about the actual taper angle. Whenever the stem is left in situ, the exact specifications of the taper must therefore be obtained from the manufacturer in order to use a metal sleeve that precisely fits it and the ball head. Failure to do so may result in severe complications, such as metallosis. In cases where it is not possible to identify the taper angle, the surgeon may even consider removal of the stem, though this significantly increases the surgical procedure's invasiveness. Only a single, uniform standard taper, such as that offered until 1994 by CeramTec, can solve these issues in the future.

Conclusion

The survival rate of the Zweymüller stems after ten years was 96 % and the complication rate was very low. Pre-operative identification of the femoral implant is of considerable importance for planning and correctly implementing revision procedures.
Literature
1.
go back to reference Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA (2001) Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res 393:137–146CrossRef Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA (2001) Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res 393:137–146CrossRef
2.
go back to reference Rajaratnam SS, Jack C, Tavakkolizadeh A, George MD, Fletcher RJ, Hankins M, Shepperd JA (2008) Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study. J Bone Joint Surg (Br) 90(1):27–30CrossRef Rajaratnam SS, Jack C, Tavakkolizadeh A, George MD, Fletcher RJ, Hankins M, Shepperd JA (2008) Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study. J Bone Joint Surg (Br) 90(1):27–30CrossRef
3.
4.
go back to reference Evola FR, Evola G, Graceffa A et al (2014) Performance of the CLS Spotorno uncemented stem in the third decade after implantation. Bone Joint J 96(4):455–461CrossRefPubMed Evola FR, Evola G, Graceffa A et al (2014) Performance of the CLS Spotorno uncemented stem in the third decade after implantation. Bone Joint J 96(4):455–461CrossRefPubMed
5.
go back to reference Lord G, Bancel P (1983) The madreporic cementless total hip arthroplasty: new experimental data and a seven-year clinical follow-up study. Clin Orthop Relat Res 176:67–76 Lord G, Bancel P (1983) The madreporic cementless total hip arthroplasty: new experimental data and a seven-year clinical follow-up study. Clin Orthop Relat Res 176:67–76
6.
go back to reference Delaunay C, Cazeau C, Kapandji AI (1998) Cementless primary total hip replacement. Four to eight year results with the Zweymüller-alloclassic prosthesis. Int Orthop 22:1–5CrossRefPubMedPubMedCentral Delaunay C, Cazeau C, Kapandji AI (1998) Cementless primary total hip replacement. Four to eight year results with the Zweymüller-alloclassic prosthesis. Int Orthop 22:1–5CrossRefPubMedPubMedCentral
7.
go back to reference Zweymüller K (1986) A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results. Instr Course Lect 35:203–225PubMed Zweymüller K (1986) A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results. Instr Course Lect 35:203–225PubMed
8.
go back to reference Swanson TV (2005) The tapered press fit total hip arthroplasty: a European alternative. J Arthroplast 20:63–67CrossRef Swanson TV (2005) The tapered press fit total hip arthroplasty: a European alternative. J Arthroplast 20:63–67CrossRef
10.
go back to reference Zweymüller K (1984) First clinical experience with an uncemented modular femoral prosthesis system with a wrought Ti-6 Al-4 V stem and an Al2 0 3 ceramic head. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, pp 150–155CrossRef Zweymüller K (1984) First clinical experience with an uncemented modular femoral prosthesis system with a wrought Ti-6 Al-4 V stem and an Al2 0 3 ceramic head. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, pp 150–155CrossRef
11.
go back to reference Zweymüller K, Semlitsch M (1982) Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V Stems. Arch Orthop Trauma Surg 100(4):229–236. doi:10.1007/BF00381662 CrossRefPubMed Zweymüller K, Semlitsch M (1982) Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V Stems. Arch Orthop Trauma Surg 100(4):229–236. doi:10.​1007/​BF00381662 CrossRefPubMed
12.
go back to reference Mohajer MA, Hofmann F, Graf R (2010) Retrospective and consecutive analysis of the long-term outcomes of the SBG stem: a 15-year follow-up study. Arch Orthop Trauma Surg 130(2):185–190CrossRefPubMed Mohajer MA, Hofmann F, Graf R (2010) Retrospective and consecutive analysis of the long-term outcomes of the SBG stem: a 15-year follow-up study. Arch Orthop Trauma Surg 130(2):185–190CrossRefPubMed
13.
go back to reference Wright C, Lambert D, Brazil D, Keggi K, Keggi J, McTighe T (2011) Clinical review of the Zweymuller femoral stem. Reconstructive Review 1(1):41–52CrossRef Wright C, Lambert D, Brazil D, Keggi K, Keggi J, McTighe T (2011) Clinical review of the Zweymuller femoral stem. Reconstructive Review 1(1):41–52CrossRef
14.
go back to reference EndlerJr M, Endler F, PlenkJr H (1984) Experimental and early clinical experience with an uncemented UHMW polyethylene acetabular prosthesis. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, New York, Tokyo, pp 191–199CrossRef EndlerJr M, Endler F, PlenkJr H (1984) Experimental and early clinical experience with an uncemented UHMW polyethylene acetabular prosthesis. In: Morscher E (ed) The cementless fixation of hip endoprostheses. Springer, Berlin Heidelberg, New York, Tokyo, pp 191–199CrossRef
15.
go back to reference Zweymüller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of a press-fit titanium hip joint endoprosthesis. Clin Orthop Relat Res 235:195–206 Zweymüller KA, Lintner FK, Semlitsch MF (1988) Biologic fixation of a press-fit titanium hip joint endoprosthesis. Clin Orthop Relat Res 235:195–206
18.
go back to reference Ottink K, Barnaart L, Westerbeek R et al (2015) Survival, clinical and radiological outcome of the Zweymüller SL/Bicon-Plus total hip arthroplasty: a 15-year follow-up study. Hip Int 25(3):204–208. doi:10.5301/hipint.5000231 CrossRefPubMed Ottink K, Barnaart L, Westerbeek R et al (2015) Survival, clinical and radiological outcome of the Zweymüller SL/Bicon-Plus total hip arthroplasty: a 15-year follow-up study. Hip Int 25(3):204–208. doi:10.​5301/​hipint.​5000231 CrossRefPubMed
19.
go back to reference Studers P, Belajevs D, Jurkevics V, Likums P (2015) Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population. Int Orthop. doi:10.1007/s00264-015-2846-z PubMed Studers P, Belajevs D, Jurkevics V, Likums P (2015) Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population. Int Orthop. doi:10.​1007/​s00264-015-2846-z PubMed
22.
go back to reference Prymka M, Vogiatzis M, Hassenpflug J (2004) Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation. Z Orthop Grenzgeb 142(3):303–308. doi:10.1055/s-2004-822666 CrossRef Prymka M, Vogiatzis M, Hassenpflug J (2004) Primary rotatory stability of hip endoprostheses stems after manual and robot assisted implantation. Z Orthop Grenzgeb 142(3):303–308. doi:10.​1055/​s-2004-822666 CrossRef
23.
24.
go back to reference Janda W, Hübl M, Stöckl B et al (2010) Performance of the Zweymüller total hip arthroplasty system: a literature review including arthroplasty register data. Eur Orthop Traumatol 1(1):9–15. doi:10.1007/s12570-010-0004-z CrossRef Janda W, Hübl M, Stöckl B et al (2010) Performance of the Zweymüller total hip arthroplasty system: a literature review including arthroplasty register data. Eur Orthop Traumatol 1(1):9–15. doi:10.​1007/​s12570-010-0004-z CrossRef
27.
go back to reference Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F (2006) Cementless total hip arthroplasty with the rectangular titanium Zweymüuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 88:2210–2215. doi:10.2106/JBJS.E.00810 CrossRefPubMed Grübl A, Chiari C, Giurea A, Gruber M, Kaider A, Marker M, Zehetgruber H, Gottsauner-Wolf F (2006) Cementless total hip arthroplasty with the rectangular titanium Zweymüuller stem. A concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg Am 88:2210–2215. doi:10.​2106/​JBJS.​E.​00810 CrossRefPubMed
28.
go back to reference Barrack RL, Burnett RSJ (2006) Preoperative planning in revision total hip arthroplasty. Instructional course lecture series. American Academy of Orthopaedic Surgeons. J Bone Joint Surg 87(12):2800–2811 Barrack RL, Burnett RSJ (2006) Preoperative planning in revision total hip arthroplasty. Instructional course lecture series. American Academy of Orthopaedic Surgeons. J Bone Joint Surg 87(12):2800–2811
31.
go back to reference Kienapfel H, Becker A (2012) Prothesenregister und Langzeitergebnisse. In: Claes L, Kirschner P, Perka C, Herausgeber MR (eds) AE-Manual der Endoprothetik. Springer, Heidelberg, Berlin, pp 419–440CrossRef Kienapfel H, Becker A (2012) Prothesenregister und Langzeitergebnisse. In: Claes L, Kirschner P, Perka C, Herausgeber MR (eds) AE-Manual der Endoprothetik. Springer, Heidelberg, Berlin, pp 419–440CrossRef
Metadata
Title
Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases
Authors
Saverio Affatato
Saverio Comitini
Matteo Fosco
Aldo Toni
Domenico Tigani
Publication date
01-11-2016
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 11/2016
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3141-3

Other articles of this Issue 11/2016

International Orthopaedics 11/2016 Go to the issue