Skip to main content
Top
Published in: International Orthopaedics 2/2011

01-02-2011 | Original Paper

Twenty-year results of the cementless Corail stem

Author: Jean-Pierre Vidalain

Published in: International Orthopaedics | Issue 2/2011

Login to get access

Abstract

The concept of an extensive hydroxyapatite (HA) coating for the fixation of a tapered femoral stem (Corail®) was introduced 25 years ago in the hope that we could achieve durable biological fixation while preserving normal periprosthetic bone activity. The value of uncemented fixation using HA-coated implants is now widely admitted. However, the characteristics of implant coating and more specifically its extent still remain a subject of debate or even controversy. This prospective study conducted over a 20-year period has greatly contributed to demonstrating the reliability of the Corail® prosthesis, in terms of functional abilities, radiographic evidence and global survivorship. A full HA coating applied on a straight and proximally flared stem induces substantial short-, mid- and long-term benefits without any deleterious effects reported. Modifications of the bone pattern have been strictly limited: slight resorption at the calcar level, absence of cortical hypertrophy and alleged stress shielding. The radiological “silence” is one of the paramount facts clearly demonstrated.
Literature
1.
go back to reference Al Hertani W, Waddell JP, Anderson GI (2000) The effect of partial vs. full hydroxyapatite coating on periprosthetic bone quality around the canine madreporic femoral stem. J Biomed Mater Res 53:518–524CrossRefPubMed Al Hertani W, Waddell JP, Anderson GI (2000) The effect of partial vs. full hydroxyapatite coating on periprosthetic bone quality around the canine madreporic femoral stem. J Biomed Mater Res 53:518–524CrossRefPubMed
2.
go back to reference Baltopoulos P, Tsintzos C, Papadakou E et al (2008) Hydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival. Acta Orthop Belg 74:323–331PubMed Baltopoulos P, Tsintzos C, Papadakou E et al (2008) Hydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival. Acta Orthop Belg 74:323–331PubMed
3.
go back to reference Bloebaum RD, Merrell M, Gutske K et al (1991) Retrieval analysis of a hydroxyapatite-coated hip prosthesis. Clin Orthop Relat Res 267:97–102PubMed Bloebaum RD, Merrell M, Gutske K et al (1991) Retrieval analysis of a hydroxyapatite-coated hip prosthesis. Clin Orthop Relat Res 267:97–102PubMed
4.
go back to reference Bloebaum RD, Zou L, Bachus KN et al (1997) Analysis of particles in acetabular components from patients with osteolysis. Clin Orthop Relat Res 338:109–118CrossRefPubMed Bloebaum RD, Zou L, Bachus KN et al (1997) Analysis of particles in acetabular components from patients with osteolysis. Clin Orthop Relat Res 338:109–118CrossRefPubMed
5.
go back to reference Campbell D, Mercer G, Nilsson KG et al (2009) Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study. Int Orthop. Epub ahead of print Campbell D, Mercer G, Nilsson KG et al (2009) Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study. Int Orthop. Epub ahead of print
6.
go back to reference Chambers B, St Clair SF, Froimson MI (2007) Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty. J Arthroplasty 22:71–74CrossRefPubMed Chambers B, St Clair SF, Froimson MI (2007) Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty. J Arthroplasty 22:71–74CrossRefPubMed
7.
go back to reference Chatelet JC, Setiey L (2004) Femoral component revision with hydroxyapatite-coated revision stems. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris Chatelet JC, Setiey L (2004) Femoral component revision with hydroxyapatite-coated revision stems. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris
8.
go back to reference Coathup MJ, Blunn GW, Flynn N et al (2001) A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem. J Bone Joint Surg Br 83:118–123CrossRefPubMed Coathup MJ, Blunn GW, Flynn N et al (2001) A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem. J Bone Joint Surg Br 83:118–123CrossRefPubMed
9.
go back to reference Epinette JA, Manley MT (2008) Uncemented stems in hip replacement–hydroxyapatite or plain porous: does it matter? Based on a prospective study of HA Omnifit stems at 15-years minimum follow-up. Hip Int 18:69–74PubMed Epinette JA, Manley MT (2008) Uncemented stems in hip replacement–hydroxyapatite or plain porous: does it matter? Based on a prospective study of HA Omnifit stems at 15-years minimum follow-up. Hip Int 18:69–74PubMed
10.
go back to reference Figved W, Opland V, Frihagen F et al (2009) Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures. Clin Orthop Relat Res 467:2426–2435CrossRefPubMed Figved W, Opland V, Frihagen F et al (2009) Cemented versus uncemented hemiarthroplasty for displaced femoral neck fractures. Clin Orthop Relat Res 467:2426–2435CrossRefPubMed
11.
go back to reference Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7CrossRefPubMed Froimson MI, Garino J, Machenaud A, Vidalain JP (2007) Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty 22:1–7CrossRefPubMed
12.
go back to reference Geesink RG (2002) Osteoconductive coatings for total joint arthroplasty. Clin Orthop Relat Res 395:53–65CrossRefPubMed Geesink RG (2002) Osteoconductive coatings for total joint arthroplasty. Clin Orthop Relat Res 395:53–65CrossRefPubMed
13.
go back to reference Hardy DCR, Frayssinet P, Guilhem A et al (1991) Bonding of hydroxyapatite-coated femoral prostheses. Histopathology of specimens from four cases. J Bone Joint Surg Br 73:732–740PubMed Hardy DCR, Frayssinet P, Guilhem A et al (1991) Bonding of hydroxyapatite-coated femoral prostheses. Histopathology of specimens from four cases. J Bone Joint Surg Br 73:732–740PubMed
14.
go back to reference Havelin LI, Espehaug B, Vollset SE et al (1995) Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register. J Bone Joint Surg Br 77:11–17PubMed Havelin LI, Espehaug B, Vollset SE et al (1995) Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register. J Bone Joint Surg Br 77:11–17PubMed
15.
go back to reference Karachalios T, Tsatsaronis C, Efraimis G et al (2004) The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. J Arthroplasty 19:469–475CrossRefPubMed Karachalios T, Tsatsaronis C, Efraimis G et al (2004) The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. J Arthroplasty 19:469–475CrossRefPubMed
16.
go back to reference Kärrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed Kärrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed
17.
go back to reference Philippot R, Delangle F, Verdot FX et al (2009) Femoral deficiency reconstruction using a hydroxyapatite-coated locked modular stem. A series of 43 total hip revisions. Orthop Traumatol Surg Res 95:119–126, Epub 2009 Mar 17CrossRefPubMed Philippot R, Delangle F, Verdot FX et al (2009) Femoral deficiency reconstruction using a hydroxyapatite-coated locked modular stem. A series of 43 total hip revisions. Orthop Traumatol Surg Res 95:119–126, Epub 2009 Mar 17CrossRefPubMed
18.
go back to reference Pinaroli A, Lavoie F, Cartillier JC et al (2009) Conservative femoral stem revision: avoiding therapeutic escalation. J Arthroplasty 24:365–373, Epub 2008 Apr 11CrossRefPubMed Pinaroli A, Lavoie F, Cartillier JC et al (2009) Conservative femoral stem revision: avoiding therapeutic escalation. J Arthroplasty 24:365–373, Epub 2008 Apr 11CrossRefPubMed
19.
go back to reference Rajaratnam SS, Jack C, Tavakkolizadeh A et al (2008) Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study. J Bone Joint Surg Br 90:27–30PubMed Rajaratnam SS, Jack C, Tavakkolizadeh A et al (2008) Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study. J Bone Joint Surg Br 90:27–30PubMed
20.
go back to reference Reikerås O, Gunderson RB (2006) Excellent results with femoral revision surgery using an extensively hydroxyapatite-coated stem: 59 patients followed for 10-16 years. Acta Orthop 77:98–103CrossRefPubMed Reikerås O, Gunderson RB (2006) Excellent results with femoral revision surgery using an extensively hydroxyapatite-coated stem: 59 patients followed for 10-16 years. Acta Orthop 77:98–103CrossRefPubMed
21.
go back to reference Shah NN, Edge AJ, Clark DW (2009) Hydroxyapatite-ceramic-coated femoral components in young patients followed-up for 16 to 19 years: an update of a previous report. J Bone Joint Surg Br 91:865–869CrossRefPubMed Shah NN, Edge AJ, Clark DW (2009) Hydroxyapatite-ceramic-coated femoral components in young patients followed-up for 16 to 19 years: an update of a previous report. J Bone Joint Surg Br 91:865–869CrossRefPubMed
22.
go back to reference Søballe K, Toksvig-Larsen S, Gelineck J et al (1993) Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed Søballe K, Toksvig-Larsen S, Gelineck J et al (1993) Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed
23.
go back to reference Vidalain JP (2004) Corail stem long-term results based upon the 15-year Artro group experience. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris Vidalain JP (2004) Corail stem long-term results based upon the 15-year Artro group experience. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris
24.
go back to reference Vidalain JP (2004) Hydroxyapatite and infection: results of a consecutive series of 49 infected total hip replacements. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris Vidalain JP (2004) Hydroxyapatite and infection: results of a consecutive series of 49 infected total hip replacements. In: Epinette JA, Manley MT (eds) Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty. Springer, Paris
25.
go back to reference Wangen H, Lereim P, Holm I et al (2008) Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem. Int Orthop 32:203–208, Epub 2007 Feb 15CrossRefPubMed Wangen H, Lereim P, Holm I et al (2008) Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem. Int Orthop 32:203–208, Epub 2007 Feb 15CrossRefPubMed
Metadata
Title
Twenty-year results of the cementless Corail stem
Author
Jean-Pierre Vidalain
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1117-2

Other articles of this Issue 2/2011

International Orthopaedics 2/2011 Go to the issue

Acknowledgement to Referees

Acknowledgement to Referees