Skip to main content
Top
Published in: Osteoporosis International 2/2019

01-02-2019 | Original Article

Radiofrequency echographic multispectrometry compared with dual X-ray absorptiometry for osteoporosis diagnosis on lumbar spine and femoral neck

Authors: M. Di Paola, D. Gatti, O. Viapiana, L. Cianferotti, L. Cavalli, C. Caffarelli, F. Conversano, E. Quarta, P. Pisani, G. Girasole, A. Giusti, M. Manfredini, G. Arioli, M. Matucci-Cerinic, G. Bianchi, R. Nuti, S. Gonnelli, M. L. Brandi, M. Muratore, M. Rossini

Published in: Osteoporosis International | Issue 2/2019

Login to get access

Abstract

Summary

An innovative, non-ionizing technique to diagnose osteoporosis on lumbar spine and femoral neck was evaluated through a multicenter study involving 1914 women. The proposed method showed significant agreement with reference gold standard method and, therefore, a potential for early osteoporosis diagnoses and possibly improved patient management.

Introduction

To assess precision (i.e., short term intra-operator precision) and diagnostic accuracy of an innovative non-ionizing technique, REMS (Radiofrequency Echographic Multi Spectrometry), in comparison with the clinical gold standard reference DXA (dual X-ray absorptiometry), through an observational multicenter clinical study.

Methods

In a multicenter cross-sectional observational study, a total of 1914 postmenopausal women (51–70 years) underwent spinal (n = 1553) and/or femoral (n = 1637) DXA, according to their medical prescription, and echographic scan of the same anatomical sites performed with the REMS approach. All the medical reports (DXA and REMS) were carefully checked to identify possible errors that could have caused inaccurate measurements: erroneous REMS reports were excluded, whereas erroneous DXA reports were re-analyzed where possible and otherwise excluded before assessing REMS accuracy. REMS precision was independently assessed.

Results

In the spinal group, quality assessment on medical reports produced the exclusion of 280 patients because of REMS errors and 78 patients because of DXA errors, whereas 296 DXA reports were re-analyzed and corrected. Analogously, in the femoral group there were 205 exclusions for REMS errors, 59 exclusions for DXA errors, and 217 re-analyzed DXA reports. In the resulting dataset (n = 1195 for spine, n = 1373 for femur) REMS outcome showed a good agreement with DXA: the average difference in bone mineral density (BMD, bias ± 2SD) was −0.004 ± 0.088 g/cm2 for spine and − 0.006 ± 0.076 g/cm2 for femur. Linear regression showed also that the two methods were well correlated: standard error of the estimate (SEE) was 5.3% for spine and 5.8% for femur. REMS precision, expressed as RMS-CV, was 0.38% for spine and 0.32% for femur.

Conclusions

The REMS approach can be used for non-ionizing osteoporosis diagnosis directly on lumbar spine and femoral neck with a good level of accuracy and precision. However, a more rigorous operator training is needed to limit the erroneous acquisitions and to ensure the full clinical practicability.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kanis JA (2007) WHO Technical Report. University of Sheffield, UK, p 66 Kanis JA (2007) WHO Technical Report. University of Sheffield, UK, p 66
2.
go back to reference Johnell O, Kanis JA (2006) An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int 17:1726–1733CrossRefPubMed Johnell O, Kanis JA (2006) An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int 17:1726–1733CrossRefPubMed
3.
go back to reference Cosman F, de Beur SJ, LeBoff MS, Lewiecki EM, Tanner B, Randall S, Lindsay R (2014) Clinician’s guide to prevention and treatment of osteoporosis. Osteoporos Int 25:2359–2381CrossRefPubMedPubMedCentral Cosman F, de Beur SJ, LeBoff MS, Lewiecki EM, Tanner B, Randall S, Lindsay R (2014) Clinician’s guide to prevention and treatment of osteoporosis. Osteoporos Int 25:2359–2381CrossRefPubMedPubMedCentral
4.
go back to reference Lewiecki EM, Laster AJ (2006) Clinical review: clinical applications of vertebral fracture assessment by dual-energy X-ray absorptiometry. J Clin Endocrinol Metab 91(11):4215–4222CrossRefPubMed Lewiecki EM, Laster AJ (2006) Clinical review: clinical applications of vertebral fracture assessment by dual-energy X-ray absorptiometry. J Clin Endocrinol Metab 91(11):4215–4222CrossRefPubMed
5.
go back to reference Abrahamsen B, van Staa T, Ariely R, Olson M, Cooper C (2009) Excess mortality following hip fracture: a systematic epidemiological review. Osteoporos Int 20(10):1633–1650CrossRefPubMed Abrahamsen B, van Staa T, Ariely R, Olson M, Cooper C (2009) Excess mortality following hip fracture: a systematic epidemiological review. Osteoporos Int 20(10):1633–1650CrossRefPubMed
7.
go back to reference Cosman F, de Beur SJ, LeBoff MS, Lewiecki EM, Tanner B, Randall S, Lindsay R (2015) Erratum to: clinician’s guide to prevention and treatment of osteoporosis. Osteoporos Int 26:2045–2047CrossRefPubMedPubMedCentral Cosman F, de Beur SJ, LeBoff MS, Lewiecki EM, Tanner B, Randall S, Lindsay R (2015) Erratum to: clinician’s guide to prevention and treatment of osteoporosis. Osteoporos Int 26:2045–2047CrossRefPubMedPubMedCentral
10.
go back to reference Quiros Roldan E, Brianese N, Raffetti E, Focà E, Pezzoli MC, Bonito A, Ferraresi A, Lanza P, Porcelli T, Castelli F (2017) Comparison between the gold standard DXA with calcaneal quantitative ultrasound based-strategy (QUS) to detect osteoporosis in an HIV infected cohort. Braz J Infect Dis 21:581–586CrossRefPubMed Quiros Roldan E, Brianese N, Raffetti E, Focà E, Pezzoli MC, Bonito A, Ferraresi A, Lanza P, Porcelli T, Castelli F (2017) Comparison between the gold standard DXA with calcaneal quantitative ultrasound based-strategy (QUS) to detect osteoporosis in an HIV infected cohort. Braz J Infect Dis 21:581–586CrossRefPubMed
11.
go back to reference Schnitzer TJ, Wysocki N, Barkema D, Griffith J, Lent V, Romba M, Welbel R, Bhuva S, Manyam B, Linn S (2012) Calcaneal quantitative ultrasound compared with hip and femoral neck dual-energy X-ray absorptiometry in people with a spinal cord injury. PM R 4:748–755CrossRefPubMed Schnitzer TJ, Wysocki N, Barkema D, Griffith J, Lent V, Romba M, Welbel R, Bhuva S, Manyam B, Linn S (2012) Calcaneal quantitative ultrasound compared with hip and femoral neck dual-energy X-ray absorptiometry in people with a spinal cord injury. PM R 4:748–755CrossRefPubMed
12.
go back to reference Shin M-H, Kweon S-S, Park K-S, Heo H, Kim S-J, Nam H-S, Jeong S-K, Chung E-K, Choi J-S (2005) Quantitative ultrasound of the calcaneus in a Korean population: reference data and relationship to bone mineral density determined by peripheral dual X-ray absorptiometry. J Korean Med Sci 20:1011–1016CrossRefPubMedPubMedCentral Shin M-H, Kweon S-S, Park K-S, Heo H, Kim S-J, Nam H-S, Jeong S-K, Chung E-K, Choi J-S (2005) Quantitative ultrasound of the calcaneus in a Korean population: reference data and relationship to bone mineral density determined by peripheral dual X-ray absorptiometry. J Korean Med Sci 20:1011–1016CrossRefPubMedPubMedCentral
13.
go back to reference Paggiosi MA, Barkmann R, Gluer CC, Roux C, Reid DM, Felsenberg D, Bradburn M, Eastell R (2012) A European multicenter comparison of quantitative ultrasound measurement variables: the OPUS study. Osteoporos Int 23:2815–2828CrossRefPubMed Paggiosi MA, Barkmann R, Gluer CC, Roux C, Reid DM, Felsenberg D, Bradburn M, Eastell R (2012) A European multicenter comparison of quantitative ultrasound measurement variables: the OPUS study. Osteoporos Int 23:2815–2828CrossRefPubMed
14.
go back to reference Kwok T, Khoo CC, Leung J, Kwok A, Qin L, Woo J, Leung PC (2012) Predictive values of calcaneal quantitative ultrasound and dual energy X-ray absorptiometry for non-vertebral fracture in older men: results from the MrOS study (Hong Kong). Osteoporos Int 23:1001–1006CrossRefPubMed Kwok T, Khoo CC, Leung J, Kwok A, Qin L, Woo J, Leung PC (2012) Predictive values of calcaneal quantitative ultrasound and dual energy X-ray absorptiometry for non-vertebral fracture in older men: results from the MrOS study (Hong Kong). Osteoporos Int 23:1001–1006CrossRefPubMed
15.
go back to reference Liu JM, Ma LY, Bi YF, Xu Y, Huang Y, Xu M, Zhao HY, Sun LH, Tao B, Li XY, Wang WQ, Ning G (2012) A population-based study examining calcaneus quantitative ultrasound and its optimal cut-points to discriminate osteoporotic fractures among 9352 Chinese women and men. J Clin Endorinol Metab 97:800–809CrossRef Liu JM, Ma LY, Bi YF, Xu Y, Huang Y, Xu M, Zhao HY, Sun LH, Tao B, Li XY, Wang WQ, Ning G (2012) A population-based study examining calcaneus quantitative ultrasound and its optimal cut-points to discriminate osteoporotic fractures among 9352 Chinese women and men. J Clin Endorinol Metab 97:800–809CrossRef
16.
go back to reference Moayyeri A, Adams JE, Adler RA, Krieg MA, Hans D, Compston J, Lewiecki EM (2012) Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis. Osteoporos Int 23:143–153CrossRefPubMed Moayyeri A, Adams JE, Adler RA, Krieg MA, Hans D, Compston J, Lewiecki EM (2012) Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis. Osteoporos Int 23:143–153CrossRefPubMed
17.
go back to reference Jiang YQ, Liu CC, Li RY, Wang WP, Ding H, Qi Q, Ta D, Dong J, Wang WQ (2014) Analysis of apparent integrated backscatter coefficient and backscatter spectral centroid shift in calcaneus in vivo for the ultrasonic evaluation of osteoporosis. Ultrasound Med Biol 40:1307–1317CrossRefPubMed Jiang YQ, Liu CC, Li RY, Wang WP, Ding H, Qi Q, Ta D, Dong J, Wang WQ (2014) Analysis of apparent integrated backscatter coefficient and backscatter spectral centroid shift in calcaneus in vivo for the ultrasonic evaluation of osteoporosis. Ultrasound Med Biol 40:1307–1317CrossRefPubMed
18.
go back to reference Garra BS, Locher M, Felker S, Wear KA (2009) Measurements of ultrasonic backscattered spectral centroid shift from spine in vivo: methodology and preliminary results. Ultrasound Med Biol 35:165–168CrossRefPubMed Garra BS, Locher M, Felker S, Wear KA (2009) Measurements of ultrasonic backscattered spectral centroid shift from spine in vivo: methodology and preliminary results. Ultrasound Med Biol 35:165–168CrossRefPubMed
19.
go back to reference Karjalainen JP, Riekkinen O, Toyras J, Hakulinen M, Kroger H, Rikkonen T, Salovaara K, Jurvelin JS (2012) Multi-site bone ultrasound measurements in elderly women with and without previous hip fractures. Osteoporos Int 23:1287–1295CrossRefPubMed Karjalainen JP, Riekkinen O, Toyras J, Hakulinen M, Kroger H, Rikkonen T, Salovaara K, Jurvelin JS (2012) Multi-site bone ultrasound measurements in elderly women with and without previous hip fractures. Osteoporos Int 23:1287–1295CrossRefPubMed
20.
go back to reference Barkmann R, Dencks S, Laugier P, Padilla F, Brixen K, Ryg J, Seekamp A, Mahlke L, Bremer A, Heller M, Gluer CC (2010) Femur ultrasound (FemUS)—first clinical results on hip fracture discrimination and estimation of femoral BMD. Osteoporos Int 21:969–976CrossRefPubMed Barkmann R, Dencks S, Laugier P, Padilla F, Brixen K, Ryg J, Seekamp A, Mahlke L, Bremer A, Heller M, Gluer CC (2010) Femur ultrasound (FemUS)—first clinical results on hip fracture discrimination and estimation of femoral BMD. Osteoporos Int 21:969–976CrossRefPubMed
21.
go back to reference Schousboe JT, Riekkinen O, Karjalainen J (2017) Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device. Osteoporos Int 28:85–93CrossRefPubMed Schousboe JT, Riekkinen O, Karjalainen J (2017) Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device. Osteoporos Int 28:85–93CrossRefPubMed
22.
go back to reference Karjalainen JP, Riekkinen O, Töyräs J, Jurvelin JS, Kröger H (2016) New method for point-of-care osteoporosis screening and diagnostics. Osteoporos Int 27:971–977CrossRefPubMed Karjalainen JP, Riekkinen O, Töyräs J, Jurvelin JS, Kröger H (2016) New method for point-of-care osteoporosis screening and diagnostics. Osteoporos Int 27:971–977CrossRefPubMed
23.
go back to reference McCloskey EV, Kanis JA, Odén A, Harvey NC, Bauer D, González-Macias J, Hans D, Kaptoge S, Krieg MA, Kwok T, Marin F, Moayyeri A, Orwoll E, Gluёr C, Johansson H (2015) Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporos Int 26:1979–1987CrossRefPubMed McCloskey EV, Kanis JA, Odén A, Harvey NC, Bauer D, González-Macias J, Hans D, Kaptoge S, Krieg MA, Kwok T, Marin F, Moayyeri A, Orwoll E, Gluёr C, Johansson H (2015) Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporos Int 26:1979–1987CrossRefPubMed
24.
go back to reference Chan MY, Nguyen ND, Center JR, Eisman JA, Nguyen TV (2013) Quantitative ultrasound and fracture risk prediction in non-osteoporotic men and women as defined by WHO criteria. Osteoporos Int 24:1015–1022CrossRefPubMed Chan MY, Nguyen ND, Center JR, Eisman JA, Nguyen TV (2013) Quantitative ultrasound and fracture risk prediction in non-osteoporotic men and women as defined by WHO criteria. Osteoporos Int 24:1015–1022CrossRefPubMed
25.
go back to reference Conversano F, Franchini R, Greco A, Soloperto G, Chiriacò F, Casciaro E, Aventaggiato M, Renna MD, Pisani P, Di Paola M, Grimaldi A, Quarta L, Quarta E, Muratore M, Laugier P, Casciaro S (2015) A novel ultrasound methodology for estimating spine mineral density. Ultrasound Med Biol 41:281–300CrossRefPubMed Conversano F, Franchini R, Greco A, Soloperto G, Chiriacò F, Casciaro E, Aventaggiato M, Renna MD, Pisani P, Di Paola M, Grimaldi A, Quarta L, Quarta E, Muratore M, Laugier P, Casciaro S (2015) A novel ultrasound methodology for estimating spine mineral density. Ultrasound Med Biol 41:281–300CrossRefPubMed
26.
go back to reference Casciaro S, Peccarisi M, Pisani P, Franchini R, Greco A, De Marco T, Grimaldi A, Quarta L, Quarta E, Muratore M, Conversano F (2016) An advanced quantitative echosound methodology for femoral neck densitometry. Ultrasound Med Biol 42:1337–1356CrossRefPubMed Casciaro S, Peccarisi M, Pisani P, Franchini R, Greco A, De Marco T, Grimaldi A, Quarta L, Quarta E, Muratore M, Conversano F (2016) An advanced quantitative echosound methodology for femoral neck densitometry. Ultrasound Med Biol 42:1337–1356CrossRefPubMed
27.
go back to reference Casciaro S, Conversano F, Pisani P, Muratore M (2015) New perspectives in echographic diagnosis of osteoporosis on hip and spine. Clin Cases Miner Bone Metab 12:143–151 Casciaro S, Conversano F, Pisani P, Muratore M (2015) New perspectives in echographic diagnosis of osteoporosis on hip and spine. Clin Cases Miner Bone Metab 12:143–151
28.
go back to reference Messina C, Bandirali M, Sconfienza LM, D’Alonzo NK, Di Leo G, Papini GDE, Ulivieri FM, Sardanelli F (2015) Prevalence and type of errors in dual-energy x-ray absorptiometry. Eur Radiol 25:1504–1511CrossRefPubMed Messina C, Bandirali M, Sconfienza LM, D’Alonzo NK, Di Leo G, Papini GDE, Ulivieri FM, Sardanelli F (2015) Prevalence and type of errors in dual-energy x-ray absorptiometry. Eur Radiol 25:1504–1511CrossRefPubMed
29.
go back to reference Engelke K, Gluer CC (2006) Quality and performance measures in bone densitometry. Part 1: errors and diagnosis. Osteoporos Int 17:1283–1292CrossRefPubMed Engelke K, Gluer CC (2006) Quality and performance measures in bone densitometry. Part 1: errors and diagnosis. Osteoporos Int 17:1283–1292CrossRefPubMed
30.
go back to reference Shepherd JA, Schousboe JT, Broy SB, Engelke K, Leslie WD (2015) Executive summary of the 2015 ISCD position development conference on advanced measures from DXA and QCT: fracture prediction beyond BMD. J Clin Densitom 18:274–286CrossRefPubMed Shepherd JA, Schousboe JT, Broy SB, Engelke K, Leslie WD (2015) Executive summary of the 2015 ISCD position development conference on advanced measures from DXA and QCT: fracture prediction beyond BMD. J Clin Densitom 18:274–286CrossRefPubMed
31.
go back to reference Altman DG, Bland JM (1983) Measurements in medicine: the analysis of method comparison studies. Statistician 32:307–317CrossRef Altman DG, Bland JM (1983) Measurements in medicine: the analysis of method comparison studies. Statistician 32:307–317CrossRef
32.
go back to reference Hui SL, Gao S, Zhou X-H, Johnston CC Jr, Lu Y, Glüer CC, Grampp S, Genant H (1997) Universal standardization of bone density measurements: a method with optimal properties for calibration among several instruments. J Bone Miner Res 12:1463–1470CrossRefPubMed Hui SL, Gao S, Zhou X-H, Johnston CC Jr, Lu Y, Glüer CC, Grampp S, Genant H (1997) Universal standardization of bone density measurements: a method with optimal properties for calibration among several instruments. J Bone Miner Res 12:1463–1470CrossRefPubMed
33.
go back to reference Lu Y, Fuerst T, Hui S, Genant HK (2001) Standardization of bone mineral density at femoral neck, trochanter and Ward’s triangle. Osteoporos Int 12:438–444CrossRefPubMed Lu Y, Fuerst T, Hui S, Genant HK (2001) Standardization of bone mineral density at femoral neck, trochanter and Ward’s triangle. Osteoporos Int 12:438–444CrossRefPubMed
34.
go back to reference Hans DB, Shepherd JA, Schwartz EN, Reid DM, Blake GM, Fordham JN, Fuerst T, Hadji P, Itabashi A, Krieg MA, Lewiecki EM (2008) Peripheral dual-energy x-ray absorptiometry in the management of osteoporosis: the 2007 ISCD official positions. J Clin Densitom 11:188–206CrossRefPubMed Hans DB, Shepherd JA, Schwartz EN, Reid DM, Blake GM, Fordham JN, Fuerst T, Hadji P, Itabashi A, Krieg MA, Lewiecki EM (2008) Peripheral dual-energy x-ray absorptiometry in the management of osteoporosis: the 2007 ISCD official positions. J Clin Densitom 11:188–206CrossRefPubMed
35.
go back to reference Blake GM, Chinn DJ, Steel SA, Patel R, Panayiotou E, Thorpe J, Fordham JN, National Osteoporosis Society Bone Densitometry (2005) A list of device-specific thresholds for the clinical interpretation of peripheral x-ray absorptiometry examinations. Osteoporos Int 16:2149–2156CrossRefPubMed Blake GM, Chinn DJ, Steel SA, Patel R, Panayiotou E, Thorpe J, Fordham JN, National Osteoporosis Society Bone Densitometry (2005) A list of device-specific thresholds for the clinical interpretation of peripheral x-ray absorptiometry examinations. Osteoporos Int 16:2149–2156CrossRefPubMed
36.
go back to reference Hopkins SJ, Welsman JR, Knapp KM (2014) Short-term precision error in dual energy x-ray absorptiometry, bone mineral density and trabecular bone score measurements; and effects of obesity on precision error. Journal of Biomedical Graphics and Computing 4:8–14CrossRef Hopkins SJ, Welsman JR, Knapp KM (2014) Short-term precision error in dual energy x-ray absorptiometry, bone mineral density and trabecular bone score measurements; and effects of obesity on precision error. Journal of Biomedical Graphics and Computing 4:8–14CrossRef
37.
go back to reference Ravaud P, Reny JL, Giraudeau B, Porcher R, Dougados M, Roux C (1999) Individual smallest detectable difference in bone mineral density measurements. J Bone Miner Res 14:1449–1456CrossRefPubMed Ravaud P, Reny JL, Giraudeau B, Porcher R, Dougados M, Roux C (1999) Individual smallest detectable difference in bone mineral density measurements. J Bone Miner Res 14:1449–1456CrossRefPubMed
38.
go back to reference Trevisan C, Gandolini GG, Sibilla P, Penotti M, Caraceni MP, Ortolani S (1992) Bone mass measurement by DXA: influence of analysis procedures and interunit variation. J Bone Miner Res 7:1373–1382CrossRefPubMed Trevisan C, Gandolini GG, Sibilla P, Penotti M, Caraceni MP, Ortolani S (1992) Bone mass measurement by DXA: influence of analysis procedures and interunit variation. J Bone Miner Res 7:1373–1382CrossRefPubMed
39.
go back to reference Larnach TA, Boyd SJ, Smart RC, Butler SP, Rohl PG, Diamond TH (1992) Reproducibility of lateral spine scans using dual energy X-ray absorptiometry. Calcif Tissue Int 51:255–258CrossRefPubMed Larnach TA, Boyd SJ, Smart RC, Butler SP, Rohl PG, Diamond TH (1992) Reproducibility of lateral spine scans using dual energy X-ray absorptiometry. Calcif Tissue Int 51:255–258CrossRefPubMed
40.
go back to reference Raffan E, Holden SL, Cullingham F, Hackett RM, Rawlings JM, German AJ (2006) Standardized positioning is essential for precise determination of body composition using dual-energy X-ray absorptiometry in dogs. J Nutr 136:1976S–1978SCrossRefPubMed Raffan E, Holden SL, Cullingham F, Hackett RM, Rawlings JM, German AJ (2006) Standardized positioning is essential for precise determination of body composition using dual-energy X-ray absorptiometry in dogs. J Nutr 136:1976S–1978SCrossRefPubMed
Metadata
Title
Radiofrequency echographic multispectrometry compared with dual X-ray absorptiometry for osteoporosis diagnosis on lumbar spine and femoral neck
Authors
M. Di Paola
D. Gatti
O. Viapiana
L. Cianferotti
L. Cavalli
C. Caffarelli
F. Conversano
E. Quarta
P. Pisani
G. Girasole
A. Giusti
M. Manfredini
G. Arioli
M. Matucci-Cerinic
G. Bianchi
R. Nuti
S. Gonnelli
M. L. Brandi
M. Muratore
M. Rossini
Publication date
01-02-2019
Publisher
Springer London
Published in
Osteoporosis International / Issue 2/2019
Print ISSN: 0937-941X
Electronic ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-018-4686-3

Other articles of this Issue 2/2019

Osteoporosis International 2/2019 Go to the issue