Background
No automated methods exist to objectively monitor and evaluate the diagnostic process while physicians review computerized medical images. The present study tested whether using eye tracking to monitor tonic and phasic pupil dynamics may prove valuable in tracking interpretive difficulty and predicting diagnostic accuracy.
Methods
Pathologists interpreted digitized breast biopsies varying in diagnosis and rated difficulty, while pupil diameter was monitored. Tonic diameter was recorded during the entire duration of interpretation, and phasic diameter was examined when the eyes fixated on a pre-determined diagnostic region during inspection.
Results
Tonic pupil diameter was higher with increasing rated difficulty levels of cases. Phasic diameter was interactively influenced by case difficulty and the eventual agreement with consensus diagnosis. More difficult cases produced increases in pupil diameter, but only when the pathologists’ diagnoses were ultimately correct. All results were robust after adjusting for the potential impact of screen brightness on pupil diameter.
Conclusions
Results contribute new understandings of the diagnostic process, theoretical positions regarding locus coeruleus-norepinephrine system function, and suggest novel approaches to monitoring, evaluating, and guiding medical image interpretation.