Introduction

There is very limited information about pulmonary cement embolism (PCE) following cement-augmented fenestrated pedicle screw (CAFPS) fixation in the literature. The aim of this study to report the incidence of PCE following CAFPS fixation in adult deformity patients with severe osteoporosis and to identify risk factors such as; the number of levels, number of screws, and the cement volume used.

Methods

281 patients (204F, 77M) in whom CAFPS fixation was used during deformity surgery were included. All patients’ routine postop 2 day chest X-rays and any available CT scans were reviewed by two radiologists. In patients with PCE, preop, early postop, and latest echocardiography studies were compared in terms of changes in pulmonary artery pressure (PAP) and right ventricular dilatation. Estimated cement volume used was calculated as: 2 cc (1 cc + 1 cc) per thoracic and 3 cc (1.5 cc + 1.5 cc) per lumbar levels, which are our routine protocol. Statistical analysis for risk factors was assessed with point biserial correlation test.

Results

Average age is 70.5 (51–89) and average follow-up is 3.2 years (2–5). A total of 2978 CAFPS were instrumented with a mean of 10.5 levels (2–16) in 281 patients. PCE was diagnosed radiologically in 46 patients (16.3%). Among these 46 patients, PCE was clinically symptomatic in only 4 patients. Overall incidence of symptomatic PCE was 1.4% (4 of 281). Symptomatic PCE was statistically significant: when CAFPS fixation was performed > 7 levels; > 14 screws were used, and > 20–25 cc cement was used for augmentation (r = 0.378). In PCE group, mean preop PAP values of 27.40 (20–37) mm/Hg increased to 32.34 (20–50) mm/Hg in early postop and decreased to 28.29 (18–49) mm/Hg at final follow-up. In symptomatic PCE patients, mean preop PAP values of 30.75 (28–36) mm/Hg increased to 45.74 (40–50) mm/Hg in early postop and decreased to 38.75 (37–40) mm/Hg at final follow-up.

Conclusion

This study showed an overall 16.3% radiological PCE and 1.4% symptomatic PCE incidence when CAFPS were used due to severe osteoporosis. The symptomatic PCE risk was significant when CAFPS were > 7 levels; > 14 fenestrated screws; and > 20–25 cc cement volume is used and this may cause PAP increase and right ventricular dilatation.

Graphical Abstract

Appendix
Available only for authorised users
Literature
1.
go back to reference Bullmann V et al (2010) Pedicle screw augmentation from a biomechanical perspective. Orthopade 39(7):673–678CrossRefPubMed Bullmann V et al (2010) Pedicle screw augmentation from a biomechanical perspective. Orthopade 39(7):673–678CrossRefPubMed
2.
go back to reference Weiser L et al (2017) Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J 26(11):2891–2897CrossRefPubMed Weiser L et al (2017) Insufficient stability of pedicle screws in osteoporotic vertebrae: biomechanical correlation of bone mineral density and pedicle screw fixation strength. Eur Spine J 26(11):2891–2897CrossRefPubMed
3.
go back to reference Hodler J, Peck D, Gilula LA (2003) Midterm outcome after vertebroplasty: predictive value of technical and patient-related factors. Radiology 227(3):662–668CrossRefPubMed Hodler J, Peck D, Gilula LA (2003) Midterm outcome after vertebroplasty: predictive value of technical and patient-related factors. Radiology 227(3):662–668CrossRefPubMed
4.
go back to reference Krueger A et al (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18(9):1257–1265CrossRefPubMedPubMedCentral Krueger A et al (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18(9):1257–1265CrossRefPubMedPubMedCentral
5.
go back to reference Kim YJ et al (2009) Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. Radiology 251(1):250–259CrossRefPubMed Kim YJ et al (2009) Pulmonary cement embolism after percutaneous vertebroplasty in osteoporotic vertebral compression fractures: incidence, characteristics, and risk factors. Radiology 251(1):250–259CrossRefPubMed
6.
go back to reference Moon BJ et al (2009) Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients. J Korean Neurosurg Soc 46(4):305–311CrossRefPubMedPubMedCentral Moon BJ et al (2009) Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients. J Korean Neurosurg Soc 46(4):305–311CrossRefPubMedPubMedCentral
7.
go back to reference Wegmann K et al (2013) Biomechanical evaluation of the primary stability of pedicle screws after augmentation with an innovative bone stabilizing system. Arch Orthop Trauma Surg 133(11):1493–1499CrossRefPubMed Wegmann K et al (2013) Biomechanical evaluation of the primary stability of pedicle screws after augmentation with an innovative bone stabilizing system. Arch Orthop Trauma Surg 133(11):1493–1499CrossRefPubMed
8.
go back to reference Rasch A et al (2010) Pulmonary Palacos embolism: a case report. Thorac Cardiovasc Surg 58(7):437–439CrossRefPubMed Rasch A et al (2010) Pulmonary Palacos embolism: a case report. Thorac Cardiovasc Surg 58(7):437–439CrossRefPubMed
9.
go back to reference Rothermich MA et al (2014) Pulmonary cement embolization after vertebroplasty requiring pulmonary wedge resection. Clin Orthop Relat Res 472(5):1652–1657CrossRefPubMedPubMedCentral Rothermich MA et al (2014) Pulmonary cement embolization after vertebroplasty requiring pulmonary wedge resection. Clin Orthop Relat Res 472(5):1652–1657CrossRefPubMedPubMedCentral
10.
go back to reference Groen RJ et al (2004) Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: a reappraisal of the vertebral venous system. Spine 29(13):1465–1471CrossRefPubMed Groen RJ et al (2004) Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: a reappraisal of the vertebral venous system. Spine 29(13):1465–1471CrossRefPubMed
11.
go back to reference Monticelli F, Meyer HJ, Tutsch-Bauer E (2005) Fatal pulmonary cement embolism following percutaneous vertebroplasty (PVP). Forensic Sci Int 149(1):35–38CrossRefPubMed Monticelli F, Meyer HJ, Tutsch-Bauer E (2005) Fatal pulmonary cement embolism following percutaneous vertebroplasty (PVP). Forensic Sci Int 149(1):35–38CrossRefPubMed
12.
go back to reference Chang MC et al (2013) Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method. J Spinal Disord Tech 26(6):305–315CrossRefPubMed Chang MC et al (2013) Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method. J Spinal Disord Tech 26(6):305–315CrossRefPubMed
13.
go back to reference Hu MH et al (2011) Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body. Eur Spine J 20(8):1281–1288CrossRefPubMedPubMedCentral Hu MH et al (2011) Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body. Eur Spine J 20(8):1281–1288CrossRefPubMedPubMedCentral
14.
go back to reference Klingler JH et al (2015) Minimally invasive technique for PMMA augmentation of fenestrated screws. Sci World J 2015:979186 Klingler JH et al (2015) Minimally invasive technique for PMMA augmentation of fenestrated screws. Sci World J 2015:979186
15.
go back to reference Janssen I et al (2017) Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J 17(6):837–844CrossRefPubMed Janssen I et al (2017) Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J 17(6):837–844CrossRefPubMed
16.
go back to reference Mueller JU et al (2016) Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws. J Neurosurg Spine 25(1):103–109CrossRefPubMed Mueller JU et al (2016) Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws. J Neurosurg Spine 25(1):103–109CrossRefPubMed
17.
go back to reference Duran C et al (2007) Pulmonary cement embolism: a complication of percutaneous vertebroplasty. Acta Radiol 48(8):854–859CrossRefPubMed Duran C et al (2007) Pulmonary cement embolism: a complication of percutaneous vertebroplasty. Acta Radiol 48(8):854–859CrossRefPubMed
18.
go back to reference Venmans A et al (2010) Percutaneous vertebroplasty and pulmonary cement embolism: results from VERTOS II. AJNR Am J Neuroradiol 31(8):1451–1453CrossRefPubMed Venmans A et al (2010) Percutaneous vertebroplasty and pulmonary cement embolism: results from VERTOS II. AJNR Am J Neuroradiol 31(8):1451–1453CrossRefPubMed
19.
go back to reference Fan HT et al (2016) The biomechanical properties of pedicle screw fixation combined with trajectory bone cement augmentation in osteoporotic vertebrae. Clin Spine Surg 29(2):78–85CrossRefPubMed Fan HT et al (2016) The biomechanical properties of pedicle screw fixation combined with trajectory bone cement augmentation in osteoporotic vertebrae. Clin Spine Surg 29(2):78–85CrossRefPubMed
20.
go back to reference Ryu KS et al (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96(1 Suppl):56–61PubMed Ryu KS et al (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg 96(1 Suppl):56–61PubMed
21.
go back to reference Barragan-Campos HM et al (2006) Percutaneous vertebroplasty for spinal metastases: complications. Radiology 238(1):354–362CrossRefPubMed Barragan-Campos HM et al (2006) Percutaneous vertebroplasty for spinal metastases: complications. Radiology 238(1):354–362CrossRefPubMed
22.
go back to reference Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537CrossRefPubMed Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537CrossRefPubMed
23.
go back to reference Bliemel C et al (2012) Higher incidence of new vertebral fractures following percutaneous vertebroplasty and kyphoplasty–fact or fiction? Acta Orthop Belg 78(2):220–229PubMed Bliemel C et al (2012) Higher incidence of new vertebral fractures following percutaneous vertebroplasty and kyphoplasty–fact or fiction? Acta Orthop Belg 78(2):220–229PubMed
Metadata
Title
Pulmonary cement embolism following cement-augmented fenestrated pedicle screw fixation in adult spinal deformity patients with severe osteoporosis (analysis of 2978 fenestrated screws)
Authors
Onur Levent Ulusoy
Sinan Kahraman
Isik Karalok
Emel Kaya
Meric Enercan
Cem Sever
Burak Abay
Selhan Karadereler
Azmi Hamzaoglu
Publication date
01-09-2018
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 9/2018
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-018-5593-1

Other articles of this Issue 9/2018

European Spine Journal 9/2018 Go to the issue