Skip to main content
Top
Published in: Osteoporosis International 1/2017

01-01-2017 | Original Article

Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device

Authors: J. T. Schousboe, O. Riekkinen, J. Karjalainen

Published in: Osteoporosis International | Issue 1/2017

Login to get access

Abstract

Summary

Pulse-echo ultrasonometry can be used as a pre-screen for hip osteoporosis before dual-energy x-ray absorptiometry (DXA), potentially allowing DXA to be avoided for the majority of post-menopausal women. Pulse-echo ultrasound measures of tibia cortical thickness are also associated with radiographically confirmed prior fractures, independent of femoral neck bone mineral density.

Introduction

To estimate how well a pulse-echo ultrasound device discriminates those who have from those who do not have hip osteoporosis (femoral neck bone mineral density [BMD] or total hip BMD T-score ≤ −2.5), and to estimate the association of pulse-echo ultrasound measures with prevalent (radiographically confirmed) clinical fractures.

Methods

Five hundred fifty-five post-menopausal women age 50 to 89 had femoral neck and total hip BMD measured by dual-energy x-ray absorptiometry (DXA), and pulse-echo ultrasound measures of distal radius, proximal tibia, distal tibia cortical thickness, and multi- and single-site density indices (DI). Using previously published threshold ultrasound values, we estimated the proportion of women who would avoid a follow-up DXA after pulse-echo ultrasonometry, and the sensitivity and specificity of this for the detection of hip osteoporosis. Logistic regression models were used to estimate the associations of pulse-echo ultrasound measures with radiographically confirmed clinical fractures within the prior 5 years.

Results

Using multi-site and single-site DI measures, follow-up DXA could be avoided for 73 and 69 % of individuals, respectively, while detecting hip osteoporosis with 80–82 % sensitivity and 81 % specificity. Radiographically confirmed prior fracture was associated with ultrasound measures of single-site DI (odds ratio (OR) 1.55, 95 % confidence interval (CI). 1.06 to 2.26) and proximal tibia cortical thickness (OR 1.47, 95 % CI 1.10 to 1.96), adjusted for age, body mass index, and femoral neck BMD.

Conclusions

Pulse-echo ultrasonometry can be used as an initial screening test for hip osteoporosis. Prospective studies of how well pulse-echo ultrasound measures predict subsequent clinical fractures are warranted.
Literature
1.
go back to reference Blake GM, Chinn DJ, Steel SA, Patel R, Panayiotou E, Thorpe J, Fordham JN, National Osteoporosis Society Bone Densitometry F (2005) A list of device-specific thresholds for the clinical interpretation of peripheral x-ray absorptiometry examinations. Osteoporos Int 16:2149–2156CrossRefPubMed Blake GM, Chinn DJ, Steel SA, Patel R, Panayiotou E, Thorpe J, Fordham JN, National Osteoporosis Society Bone Densitometry F (2005) A list of device-specific thresholds for the clinical interpretation of peripheral x-ray absorptiometry examinations. Osteoporos Int 16:2149–2156CrossRefPubMed
2.
go back to reference Patel R, Blake GM, Fordham JN, McCrea JD, Ryan PJ (2011) Peripheral X-ray absorptiometry in the management of osteoporosis. Patel R, Blake GM, Fordham JN, McCrea JD, Ryan PJ (2011) Peripheral X-ray absorptiometry in the management of osteoporosis.
3.
go back to reference Hans DB, Shepherd JA, Schwartz EN et al (2008) Peripheral dual-energy x-ray absorptiometry in the management of osteoporosis: the 2007 ISCD Official Positions. J Clin Densitom 11:188–206CrossRefPubMed Hans DB, Shepherd JA, Schwartz EN et al (2008) Peripheral dual-energy x-ray absorptiometry in the management of osteoporosis: the 2007 ISCD Official Positions. J Clin Densitom 11:188–206CrossRefPubMed
4.
go back to reference Krieg MA, Barkmann R, Gonnelli S et al (2008) Quantitative ultrasound in the management of osteoporosis: the 2007 ISCD Official Positions. J Clin Densitom 11:163–187CrossRefPubMed Krieg MA, Barkmann R, Gonnelli S et al (2008) Quantitative ultrasound in the management of osteoporosis: the 2007 ISCD Official Positions. J Clin Densitom 11:163–187CrossRefPubMed
5.
go back to reference Karjalainen J, Riekkinen O, Töyräs J, Kröger H, Jurvelin J (2008) Ultrasonic assessment of cortical bone thickness in vitro and in vivo. IEEE Trans Ultrason Ferroelec Freq Control 55:2191–2197CrossRef Karjalainen J, Riekkinen O, Töyräs J, Kröger H, Jurvelin J (2008) Ultrasonic assessment of cortical bone thickness in vitro and in vivo. IEEE Trans Ultrason Ferroelec Freq Control 55:2191–2197CrossRef
6.
go back to reference Karjalainen JP, Riekkinen O, Toyras J, Hakulinen M, Kroger H, Rikkonen T, Salovaara K, Jurvelin JS (2012) Multi-site bone ultrasound measurements in elderly women with and without previous hip fractures. Osteoporos Int 23:1287–1295CrossRefPubMed Karjalainen JP, Riekkinen O, Toyras J, Hakulinen M, Kroger H, Rikkonen T, Salovaara K, Jurvelin JS (2012) Multi-site bone ultrasound measurements in elderly women with and without previous hip fractures. Osteoporos Int 23:1287–1295CrossRefPubMed
7.
go back to reference Karjalainen JP, Riekkinen O, Toyras J, Jurvelin JS, Kroger H (2016) New method for point-of-care osteoporosis screening and diagnostics. Osteoporos Int 27:971–977CrossRefPubMed Karjalainen JP, Riekkinen O, Toyras J, Jurvelin JS, Kroger H (2016) New method for point-of-care osteoporosis screening and diagnostics. Osteoporos Int 27:971–977CrossRefPubMed
8.
go back to reference Kanis JA, Oden A, Johansson H, Borgstrom F, Strom O, McCloskey E (2009) FRAX and its applications to clinical practice. Bone 44:734–743CrossRefPubMed Kanis JA, Oden A, Johansson H, Borgstrom F, Strom O, McCloskey E (2009) FRAX and its applications to clinical practice. Bone 44:734–743CrossRefPubMed
9.
go back to reference Pritchard JM, Giangregorio LM, Ioannidis G, Papaioannou A, Adachi JD, Leslie WD (2012) Ankle fractures do not predict osteoporotic fractures in women with or without diabetes. Osteoporos Int 23:957–962CrossRefPubMed Pritchard JM, Giangregorio LM, Ioannidis G, Papaioannou A, Adachi JD, Leslie WD (2012) Ankle fractures do not predict osteoporotic fractures in women with or without diabetes. Osteoporos Int 23:957–962CrossRefPubMed
10.
go back to reference Stata C (2005) SUEST—Seemingly unrelated estimation. Stata Reference Manual. Stata Press, College Station, TX, pp 301–322 Stata C (2005) SUEST—Seemingly unrelated estimation. Stata Reference Manual. Stata Press, College Station, TX, pp 301–322
11.
go back to reference Steyerberg EW (2010) Clinical prediction models. A practical approach to development, validation, and updating. Springer Science + Business Media, New York, NY Steyerberg EW (2010) Clinical prediction models. A practical approach to development, validation, and updating. Springer Science + Business Media, New York, NY
12.
go back to reference Clowes JA, Eastell R, Peel NF (2005) The discriminative ability of peripheral and axial bone measurements to identify proximal femoral, vertebral, distal forearm and proximal humeral fractures: a case control study. Osteoporos Int 16:1794–1802CrossRefPubMed Clowes JA, Eastell R, Peel NF (2005) The discriminative ability of peripheral and axial bone measurements to identify proximal femoral, vertebral, distal forearm and proximal humeral fractures: a case control study. Osteoporos Int 16:1794–1802CrossRefPubMed
13.
go back to reference Cummings SR, Black DM, Nevitt MC, Browner W, Cauley J, Ensrud K, Genant HK, Palermo L, Scott J, Vogt TM (1993) Bone density at various sites for prediction of hip fractures. The Study of Osteoporotic Fractures Research Group. Lancet 341:72–75CrossRefPubMed Cummings SR, Black DM, Nevitt MC, Browner W, Cauley J, Ensrud K, Genant HK, Palermo L, Scott J, Vogt TM (1993) Bone density at various sites for prediction of hip fractures. The Study of Osteoporotic Fractures Research Group. Lancet 341:72–75CrossRefPubMed
14.
go back to reference McCloskey EV, Kanis JA, Oden A et al (2015) Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporos Int 26:1979–1987CrossRefPubMed McCloskey EV, Kanis JA, Oden A et al (2015) Predictive ability of heel quantitative ultrasound for incident fractures: an individual-level meta-analysis. Osteoporos Int 26:1979–1987CrossRefPubMed
Metadata
Title
Prediction of hip osteoporosis by DXA using a novel pulse-echo ultrasound device
Authors
J. T. Schousboe
O. Riekkinen
J. Karjalainen
Publication date
01-01-2017
Publisher
Springer London
Published in
Osteoporosis International / Issue 1/2017
Print ISSN: 0937-941X
Electronic ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-016-3722-4

Other articles of this Issue 1/2017

Osteoporosis International 1/2017 Go to the issue