Abstract

Purpose

To summarize the biological effects of metal debris from hip arthroplasties which characterize a polymorphic clinical spectrum of local and remote manifestation.

Methods

Retrospective study. Patient, implant, and surgical characteristics were collected, including implant survival, clinical manifestations, cause of arthroplasty revision or implant failure, and peri- and intra-operative complications. The primary endpoint was implant survivorship. Hip revision arthroplasty was decided considering clinical signs and symptoms, abnormal imaging (XR, MR, TC, echotomography, scintigraphy), and blood metal ion level. An ad hoc electronic form was used to collect demographic, epidemiological, and clinical variables. In-between group comparisons of quantitative variables were performed with the Student t test and the Mann-Whitney for parametric and non-parametric variables, respectively. Logistic regression analyses were carried out to assess the relationship between clinical and radiographic characteristics and stem and cup revision. Radiographic measurements of implant positioning validity and reliability were assessed using Krippendorff’s alpha reliability coefficient. The statistical software STATA version 15 (StatsCorp, TX) was used to perform statistical computations.

Results

In this MoM THA series, the most incident cause of implant failure was ARMD in 11 out of 14 (78.6%) patients. All clinical failure manifestations, revision surgery highlights, and intra-operative findings are reported.

Conclusions

The local adverse reactions include lesions of different clinical relevance from small asymptomatic soft tissue lesions to dramatic osteolysis, necrosis, effusion, and growing masses which can cause secondary pathological effects. Symptoms of systemic toxicity are rarely described but may have been largely unreported in literature. Despite the extensive literature on the topic, the patient’s management is still uncertain and challenging. Every metallic implant (e.g., screws, plates, spinal instrumentations) has a potential local or systemic adverse effect. Organizing a national registry of arthroplasty should be mandatory, in order to collect data about the patients, the surgery, the implanted device (with a careful post-marketing tracking), and the follow-up for all the procedures performed at a national level. The data collected in the registry will allow to analyze the implant survival and to better recognize the undesirable and sometimes unexpected effects of different biomaterials on the whole body.
Literature
1.
go back to reference MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F (2003) Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 406:282–296CrossRef MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F (2003) Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 406:282–296CrossRef
2.
go back to reference Corten K, MacDonald SJ (2010) Hip resurfacing data from national joint registries: what do they tell us? What do they not tell us? Clin Orthop Relat Res 468(2):351–357CrossRefPubMed Corten K, MacDonald SJ (2010) Hip resurfacing data from national joint registries: what do they tell us? What do they not tell us? Clin Orthop Relat Res 468(2):351–357CrossRefPubMed
3.
go back to reference Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW (2012) Failure rates of stemmed metal on metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet 379(9822):1199–1204CrossRefPubMed Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW (2012) Failure rates of stemmed metal on metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet 379(9822):1199–1204CrossRefPubMed
4.
go back to reference Bordini B, Stea S, Castagnini F, Busanelli L, Giardina F, Toni A (2018) The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six cementless total hip arthroplasties. Int Orthop. https://doi.org/10.1007/s00264-018-4097-2 Bordini B, Stea S, Castagnini F, Busanelli L, Giardina F, Toni A (2018) The influence of bearing surfaces on periprosthetic hip infections: analysis of thirty nine thousand, two hundred and six cementless total hip arthroplasties. Int Orthop. https://​doi.​org/​10.​1007/​s00264-018-4097-2
5.
go back to reference Hothi HS, Berber R, Panagiotopoulos AC, Whittaker RK, Rhead C, Skinner JA, Hart AJ (2016) Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study. Int Orthop 40:2247–2254CrossRefPubMed Hothi HS, Berber R, Panagiotopoulos AC, Whittaker RK, Rhead C, Skinner JA, Hart AJ (2016) Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study. Int Orthop 40:2247–2254CrossRefPubMed
6.
go back to reference Azam MQ, McMahon S, Hawdon G, Sankineani SR (2016) Survivorship and clinical outcome of Birmingham hip resurfacing: a minimum ten years’ follow-up. Int Orthop 40:1–7CrossRefPubMed Azam MQ, McMahon S, Hawdon G, Sankineani SR (2016) Survivorship and clinical outcome of Birmingham hip resurfacing: a minimum ten years’ follow-up. Int Orthop 40:1–7CrossRefPubMed
8.
go back to reference Matharu GS, Mellon SJ, Murray DW, Pandit HG (2015) Follow-up guidance for metal-on-metal hip replacement patients should be updated. Int Orthop 39:609–610CrossRefPubMed Matharu GS, Mellon SJ, Murray DW, Pandit HG (2015) Follow-up guidance for metal-on-metal hip replacement patients should be updated. Int Orthop 39:609–610CrossRefPubMed
9.
go back to reference Guenther D, Thomas P, Kendoff D, Omar M, Gehrke T, Haasper C (2016) Allergic reactions in arthroplasty: myth or serious problem? Int Orthop 40:239–244CrossRefPubMed Guenther D, Thomas P, Kendoff D, Omar M, Gehrke T, Haasper C (2016) Allergic reactions in arthroplasty: myth or serious problem? Int Orthop 40:239–244CrossRefPubMed
10.
go back to reference Kretzer JP, Mueller U, Streit MR, Kiefer H, Sonntag R, Streicher RM, Reinders J (2018) Ion release in ceramic bearings for total hip replacement: results from an in vitro and an in vivo study. Int Orthop 42:65–70CrossRefPubMed Kretzer JP, Mueller U, Streit MR, Kiefer H, Sonntag R, Streicher RM, Reinders J (2018) Ion release in ceramic bearings for total hip replacement: results from an in vitro and an in vivo study. Int Orthop 42:65–70CrossRefPubMed
12.
go back to reference Bisschop R, Boomsma MF, Van Raay JJAM, Tiebosch ATMG, Maas M, Gerritsma CLE (2013) High prevalence of pseudotumors in patients with a Birmingham Hip Resurfacing prosthesis: a prospective cohort study of one hundred and twenty nine patients. J Bone Joint Surg Am 95(17):1554–1560CrossRefPubMed Bisschop R, Boomsma MF, Van Raay JJAM, Tiebosch ATMG, Maas M, Gerritsma CLE (2013) High prevalence of pseudotumors in patients with a Birmingham Hip Resurfacing prosthesis: a prospective cohort study of one hundred and twenty nine patients. J Bone Joint Surg Am 95(17):1554–1560CrossRefPubMed
13.
go back to reference Khatkar H, Hothi H, de Villiers D, Lausmann C, Kendoff D, Gehrke T, Skinner J, Hart A (2017) Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements. Int Orthop 41:1101–1105CrossRefPubMed Khatkar H, Hothi H, de Villiers D, Lausmann C, Kendoff D, Gehrke T, Skinner J, Hart A (2017) Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements. Int Orthop 41:1101–1105CrossRefPubMed
14.
go back to reference Scully WF, Teeny SM (2013) Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics 36(5):e666–e670CrossRefPubMed Scully WF, Teeny SM (2013) Pseudotumor associated with metal-on-polyethylene total hip arthroplasty. Orthopedics 36(5):e666–e670CrossRefPubMed
15.
go back to reference Bisseling P, Tan T, Lu Z, Campbell PA, Susante JL (2013) Absence of a metal on metal bearing does not preclude the formation of a destructive pseudotumor in the hip – a case report. Acta Orthop 84:437–441CrossRefPubMedPubMedCentral Bisseling P, Tan T, Lu Z, Campbell PA, Susante JL (2013) Absence of a metal on metal bearing does not preclude the formation of a destructive pseudotumor in the hip – a case report. Acta Orthop 84:437–441CrossRefPubMedPubMedCentral
17.
go back to reference Hsu AR, Gross CE, Levine BR (2012) Pseudotumor from modular neck corrosion after ceramic on polyethylene total hip arthroplasty. Am J Orthop 41(9):422–426PubMed Hsu AR, Gross CE, Levine BR (2012) Pseudotumor from modular neck corrosion after ceramic on polyethylene total hip arthroplasty. Am J Orthop 41(9):422–426PubMed
19.
go back to reference Apostoli P, Catalani S, Zaghini A, Mariotti A, Poliani PL, Vielmi V, Semeraro F, Duse S, Porzionato A, Macchie V, Padovani A, Rizzetti MC, De Caro D (2013) High doses of cobalt induce optic and auditory neuropathy. Exp Toxicol Pathol 65:719–727CrossRefPubMed Apostoli P, Catalani S, Zaghini A, Mariotti A, Poliani PL, Vielmi V, Semeraro F, Duse S, Porzionato A, Macchie V, Padovani A, Rizzetti MC, De Caro D (2013) High doses of cobalt induce optic and auditory neuropathy. Exp Toxicol Pathol 65:719–727CrossRefPubMed
20.
go back to reference Paustenbach DJ, Galbraith DA, Finley BL (2014) Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol (Phila) 52(2):98–112CrossRef Paustenbach DJ, Galbraith DA, Finley BL (2014) Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol (Phila) 52(2):98–112CrossRef
23.
go back to reference Matthies AK, Henckel J, Cro S, Suarez A, Noble PC, Skinner J, Hart AJ (2014) Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing. J Orthop Res 32(1):167–174CrossRefPubMed Matthies AK, Henckel J, Cro S, Suarez A, Noble PC, Skinner J, Hart AJ (2014) Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing. J Orthop Res 32(1):167–174CrossRefPubMed
25.
go back to reference Tao R, Liu F, Liu Y, Lu Y, Xu H, Cao Y, Zhou Z, Wang W (2018) A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients-a minimum of five year follow-up. Int Orthop. https://doi.org/10.1007/s00264-018-3819-9 Tao R, Liu F, Liu Y, Lu Y, Xu H, Cao Y, Zhou Z, Wang W (2018) A prospective comparative study of hip resurfacing arthroplasty and large-diameter head metal-on-metal total hip arthroplasty in younger patients-a minimum of five year follow-up. Int Orthop. https://​doi.​org/​10.​1007/​s00264-018-3819-9
26.
go back to reference Fessy MH, N’diaye A, Carret JP, Fischer LP (1999) Locating the center of rotation of the hip. Surg Radiol Anat 21:247–250CrossRefPubMed Fessy MH, N’diaye A, Carret JP, Fischer LP (1999) Locating the center of rotation of the hip. Surg Radiol Anat 21:247–250CrossRefPubMed
27.
go back to reference Bolland BJRF, Culliford DJ, Langton DJ, Millington JPS, Arden NK, Latham JM (2011) High failure rates with a large diameter hybrid metal-on-metal total hip replacement: clinical radiological and retrieval analysis. J Bone Joint Surg Br 93(5):608–615CrossRefPubMed Bolland BJRF, Culliford DJ, Langton DJ, Millington JPS, Arden NK, Latham JM (2011) High failure rates with a large diameter hybrid metal-on-metal total hip replacement: clinical radiological and retrieval analysis. J Bone Joint Surg Br 93(5):608–615CrossRefPubMed
28.
go back to reference Hartmann A, Hannemann F, Lutzner J, Seidler A, Drexler H, Günther KP, Schmitt J (2013) Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing – systematic review of clinical and epidemiological studies. PLoS One 8(8):e70359CrossRefPubMedPubMedCentral Hartmann A, Hannemann F, Lutzner J, Seidler A, Drexler H, Günther KP, Schmitt J (2013) Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing – systematic review of clinical and epidemiological studies. PLoS One 8(8):e70359CrossRefPubMedPubMedCentral
29.
go back to reference Liow MHL, Kwon YM (2017) Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop 41(5):885–892CrossRefPubMed Liow MHL, Kwon YM (2017) Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop 41(5):885–892CrossRefPubMed
30.
go back to reference Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW (2011) “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplast 26(4):511–518CrossRef Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW (2011) “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplast 26(4):511–518CrossRef
31.
go back to reference Williams DH, Greidanus NV, Masri BA, Duncan CP, Garbuz DS (2011) Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty. J Bone Joint Surg Am 93(23):2164–2171CrossRefPubMed Williams DH, Greidanus NV, Masri BA, Duncan CP, Garbuz DS (2011) Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty. J Bone Joint Surg Am 93(23):2164–2171CrossRefPubMed
32.
go back to reference Hart AJ, Satchithananda K, Liddle AD, Sabah SA, McRobbie D, Henckel J, Cobb JP, Skinner JA, Mitchell AW (2012) Pseudo-tumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg Am 94(4):317–325CrossRefPubMed Hart AJ, Satchithananda K, Liddle AD, Sabah SA, McRobbie D, Henckel J, Cobb JP, Skinner JA, Mitchell AW (2012) Pseudo-tumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg Am 94(4):317–325CrossRefPubMed
33.
go back to reference Sabah SA, Mitchell AW, Henckel J, Sandison A, Skinner A, Hart AJ (2011) Magnetic resonance imaging findings in painful metal-on- metal hips: a prospective study. J Arthroplast 26(1):71–6.e2CrossRef Sabah SA, Mitchell AW, Henckel J, Sandison A, Skinner A, Hart AJ (2011) Magnetic resonance imaging findings in painful metal-on- metal hips: a prospective study. J Arthroplast 26(1):71–6.e2CrossRef
34.
go back to reference Campe CB, Palmer WE (2013) MR imaging of metal-on-metal hip prostheses. Magn Reson Imaging Clin N Am 21:155–168CrossRefPubMed Campe CB, Palmer WE (2013) MR imaging of metal-on-metal hip prostheses. Magn Reson Imaging Clin N Am 21:155–168CrossRefPubMed
35.
go back to reference Algarni AD, Huk OL, Pelmus M (2012) Metallosis-induced iliopsoas bursal cyst causing venous obstruction and lower-limb swelling after metal-on-metal THA. Orthopedics 35(12):e1811–e1814CrossRefPubMed Algarni AD, Huk OL, Pelmus M (2012) Metallosis-induced iliopsoas bursal cyst causing venous obstruction and lower-limb swelling after metal-on-metal THA. Orthopedics 35(12):e1811–e1814CrossRefPubMed
36.
go back to reference Doria C, De Santis V, Falcone G, Proietti L, De Santis E (2003) Osseointegration in hip prostheses: experimental study in sheep. Int Orthop 27:272–277CrossRefPubMedPubMedCentral Doria C, De Santis V, Falcone G, Proietti L, De Santis E (2003) Osseointegration in hip prostheses: experimental study in sheep. Int Orthop 27:272–277CrossRefPubMedPubMedCentral
37.
go back to reference Gruber FW, Böck A, Trattnig S, Lintner F, Ritschl P (2007) Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplast 22(6):923–927CrossRef Gruber FW, Böck A, Trattnig S, Lintner F, Ritschl P (2007) Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplast 22(6):923–927CrossRef
38.
go back to reference Caicedo MS, Pennekamp PH, McAllister K, Jacobs JJ, Hallab NJ (2010) Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A 93(4):1312–1321PubMed Caicedo MS, Pennekamp PH, McAllister K, Jacobs JJ, Hallab NJ (2010) Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A 93(4):1312–1321PubMed
39.
go back to reference Tuan RS, Lee FY, Konttinen Y, Wilkinson JM, Smith RL (2008) What are the local and systemic biological reactions and mediators to wear debris and what host factors determine or modulate the biological response to wear particles? J Am Acad Orthop Surg 16(Suppl 1):S42–S48CrossRefPubMedPubMedCentral Tuan RS, Lee FY, Konttinen Y, Wilkinson JM, Smith RL (2008) What are the local and systemic biological reactions and mediators to wear debris and what host factors determine or modulate the biological response to wear particles? J Am Acad Orthop Surg 16(Suppl 1):S42–S48CrossRefPubMedPubMedCentral
40.
go back to reference Hallab NJ, Mikecz K, Vermes C, Skipor A, Jacobs JJ (2001) Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation. Mol Cell Biochem 222:127–136CrossRefPubMed Hallab NJ, Mikecz K, Vermes C, Skipor A, Jacobs JJ (2001) Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation. Mol Cell Biochem 222:127–136CrossRefPubMed
42.
go back to reference Hart AJ, Matthies A, Henckel J, Ilo K, Skinner J, Noble P (2012) Understanding why metal-on-metal hip arthroplasties fail: a comparison between patients with well-functioning and revised Birmingham hip resurfacing arthroplasties. AAOS exhibit selection. J Bone Joint Surg Am 94(4):e22CrossRefPubMed Hart AJ, Matthies A, Henckel J, Ilo K, Skinner J, Noble P (2012) Understanding why metal-on-metal hip arthroplasties fail: a comparison between patients with well-functioning and revised Birmingham hip resurfacing arthroplasties. AAOS exhibit selection. J Bone Joint Surg Am 94(4):e22CrossRefPubMed
43.
go back to reference Donell ST, Darrah C, Nolan JF, Wimhurst J, Toms A, Barker THW, Case CP, Tucker JK (2010) Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. J Bone Joint Surg Br 92(11):1501–1508CrossRefPubMed Donell ST, Darrah C, Nolan JF, Wimhurst J, Toms A, Barker THW, Case CP, Tucker JK (2010) Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs. J Bone Joint Surg Br 92(11):1501–1508CrossRefPubMed
44.
go back to reference Siddiqui IA, Sabah SA, Satchithananda K, Lim AK, Cro S, Henckel J, Skinner JA, Hart AJ (2014) A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty. Acta Orthop 85(4):375–382CrossRefPubMedPubMedCentral Siddiqui IA, Sabah SA, Satchithananda K, Lim AK, Cro S, Henckel J, Skinner JA, Hart AJ (2014) A comparison of the diagnostic accuracy of MARS MRI and ultrasound of the painful metal-on-metal hip arthroplasty. Acta Orthop 85(4):375–382CrossRefPubMedPubMedCentral
45.
go back to reference Robinson E, Henckel J, Sabah S, Satchithananda K, Skinner J, Hart A (2014) Cross-sectional imaging of metal-on-metal hip arthroplasties. Can we substitute MARS MRI with CT? Acta Orthop 85(6):577–584CrossRefPubMedPubMedCentral Robinson E, Henckel J, Sabah S, Satchithananda K, Skinner J, Hart A (2014) Cross-sectional imaging of metal-on-metal hip arthroplasties. Can we substitute MARS MRI with CT? Acta Orthop 85(6):577–584CrossRefPubMedPubMedCentral
46.
go back to reference Hannemann F et al (2013) European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 99:263–271CrossRefPubMed Hannemann F et al (2013) European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res 99:263–271CrossRefPubMed
48.
go back to reference Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B, Skinner JA (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br 93(10):1308–1313CrossRefPubMed Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson B, Skinner JA (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br 93(10):1308–1313CrossRefPubMed
49.
go back to reference Manunta ML, Careddu GM, Masala G, Columbano N, Doria C, Crissantu L, Sanna Passino E (2008) Lumbar interbody expanding cage. A preliminary study on an animal model. Vet Comp Orthop Traumatol 4:382–384 Manunta ML, Careddu GM, Masala G, Columbano N, Doria C, Crissantu L, Sanna Passino E (2008) Lumbar interbody expanding cage. A preliminary study on an animal model. Vet Comp Orthop Traumatol 4:382–384
50.
go back to reference Floerkemeier T, Budde S, Wirries N, von Lewinski G, Windhagen H, Ezechieli M (2017) The outcome of the partial resurfacing arthroplasty of the hip shows high numbers of failures and conversion to total arthroplasty. Int Orthop 41(10):2001–2008CrossRefPubMed Floerkemeier T, Budde S, Wirries N, von Lewinski G, Windhagen H, Ezechieli M (2017) The outcome of the partial resurfacing arthroplasty of the hip shows high numbers of failures and conversion to total arthroplasty. Int Orthop 41(10):2001–2008CrossRefPubMed
51.
Metadata
Title
Pleomorphic clinical spectrum of metallosis in total hip arthroplasty
Authors
Francesco Pisanu
Carlo Doria
Matteo Andreozzi
Marco Bartoli
Laura Saderi
Giovanni Sotgiu
Paolo Tranquilli Leali
Publication date
01-01-2019
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 1/2019
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4176-4

Other articles of this Issue 1/2019

International Orthopaedics 1/2019 Go to the issue