Abstract

Background

Dorsal plate and screw fixation is a popular choice for metacarpal stabilization. The balance between construct stability and soft tissue dissection remains a surgical dilemma. Historically, six cortices of bone fixation on either side of a fracture were deemed necessary. This study aims to elucidate whether four cortices of locked fixation on either side of the fracture is equivalent to the current gold standard of six cortices of nonlocked fixation on either side of the fracture. If so, less dissection to insert shorter plates with fewer screws could be used to stably fix these fractures.

Methods

With biomechanical testing-grade composite Sawbones, a comminuted metacarpal fracture model was used to test two fixation constructs consisting of a standard dorsal plate and either six bicortical nonlocking screws (three screws per segment) or four bicortical locking screws (two screws per segment). Thirty specimens were tested to failure in cantilever bending and torsion.

Results

There was statistical equivalence between the locking and nonlocking constructs in cantilever bending stiffness, torsional stiffness, maximum bending load, and maximum torque.

Conclusion

The tested metacarpal fracture model had equivalent biomechanical properties when fixed with a standard dorsal plate and either six bicortical nonlocking screws or four bicortical locking screws. By utilizing fewer cortices of fixation, there will be less dissection and less soft tissue stripping during fixation of metacarpal fractures. This will also be of benefit in very proximal or distal fractures as multiple cortices of fixation are often difficult to obtain during stabilization of these challenging fractures.
Literature
1.
go back to reference Bach HG, Gonzalez MH, Hall RF. Locked intramedullary nailing of metacarpal fractures secondary to gunshot wounds. J Hand Surg [Am]. 2006;31A(7):1083–7.CrossRef Bach HG, Gonzalez MH, Hall RF. Locked intramedullary nailing of metacarpal fractures secondary to gunshot wounds. J Hand Surg [Am]. 2006;31A(7):1083–7.CrossRef
2.
go back to reference Bottlang M, Doornink J, Fitzpatrick DC, et al. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94.PubMedCrossRef Bottlang M, Doornink J, Fitzpatrick DC, et al. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985–94.PubMedCrossRef
3.
go back to reference Bottlang M, Doornink J, Lujan TJ, Fitzpatrick DC, Marsh JL, Augat P, et al. Effects of construct stiffness on healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92(2):12–22.PubMedCrossRef Bottlang M, Doornink J, Lujan TJ, Fitzpatrick DC, Marsh JL, Augat P, et al. Effects of construct stiffness on healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92(2):12–22.PubMedCrossRef
4.
go back to reference Dona E, Gillies RM, Gianoutsos MP, et al. Plating of metacarpal fractures: unicortical or bicortical screws? J Hand Surg (Br). 2004;29(3):218–21. Dona E, Gillies RM, Gianoutsos MP, et al. Plating of metacarpal fractures: unicortical or bicortical screws? J Hand Surg (Br). 2004;29(3):218–21.
5.
go back to reference Dougherty PJ, Kim D, Meisterling S, et al. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric study. J Orthop Trauma. 2008;22(6):399–403.PubMedCrossRef Dougherty PJ, Kim D, Meisterling S, et al. Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric study. J Orthop Trauma. 2008;22(6):399–403.PubMedCrossRef
6.
go back to reference Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488–93.PubMedCrossRef Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Orthop Trauma. 2004;18(8):488–93.PubMedCrossRef
7.
go back to reference Fambrough RA, Green DP. Tendon rupture as a complication of screw fixation in fractures in the hand. A case report. J Bone Joint Surg Am. 1979;61(5):781–2.PubMed Fambrough RA, Green DP. Tendon rupture as a complication of screw fixation in fractures in the hand. A case report. J Bone Joint Surg Am. 1979;61(5):781–2.PubMed
8.
go back to reference Firoozbakhsh KK, Moneim MS, Doherty W, et al. Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading. Clin Orthop. 1996;325:296–301.PubMedCrossRef Firoozbakhsh KK, Moneim MS, Doherty W, et al. Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading. Clin Orthop. 1996;325:296–301.PubMedCrossRef
9.
go back to reference Firoozbakhsh KK, Moneim MS, Howey T, et al. Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques. J Hand Surg [Am]. 1993;18(6):1059–68.CrossRef Firoozbakhsh KK, Moneim MS, Howey T, et al. Comparative fatigue strengths and stabilities of metacarpal internal fixation techniques. J Hand Surg [Am]. 1993;18(6):1059–68.CrossRef
10.
go back to reference Freeland AE, Orbay JL. Extraarticular hand fractures in adults: a review of new developments. Clin Orthop. 2006;445:133–45.PubMed Freeland AE, Orbay JL. Extraarticular hand fractures in adults: a review of new developments. Clin Orthop. 2006;445:133–45.PubMed
11.
go back to reference Gajendran VK, Szabo RM, Myo GK, et al. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model. J Hand Surg [Am]. 2009;34(10):1851–8.CrossRef Gajendran VK, Szabo RM, Myo GK, et al. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model. J Hand Surg [Am]. 2009;34(10):1851–8.CrossRef
12.
go back to reference Gardner MJ, Nork SE, Huber P, Krieg JC. Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study. J Orthop Trauma. 2009;23:281–7.PubMedCrossRef Gardner MJ, Nork SE, Huber P, Krieg JC. Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study. J Orthop Trauma. 2009;23:281–7.PubMedCrossRef
13.
go back to reference Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34 Suppl 2:B63–76.PubMedCrossRef Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34 Suppl 2:B63–76.PubMedCrossRef
14.
go back to reference Gonzalez MH, Igram CM, Hall Jr RF. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg [Am]. 1995;20(3):382–7.CrossRef Gonzalez MH, Igram CM, Hall Jr RF. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg [Am]. 1995;20(3):382–7.CrossRef
15.
go back to reference Hak DJ, Althausen P, Hazelwood SJ. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough? J Orthop Trauma. 2010;24(4):207–11.PubMedCrossRef Hak DJ, Althausen P, Hazelwood SJ. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough? J Orthop Trauma. 2010;24(4):207–11.PubMedCrossRef
16.
go back to reference Harris AH, Fernandes-Taylor S, Giori N. “Not statistically different” does not necessarily mean “the same”: the important but underappreciated distinction between difference and equivalence studies. J Bone Joint Surg Am. 2012;94(5):e29 1–4. Harris AH, Fernandes-Taylor S, Giori N. “Not statistically different” does not necessarily mean “the same”: the important but underappreciated distinction between difference and equivalence studies. J Bone Joint Surg Am. 2012;94(5):e29 1–4.
17.
go back to reference Lindvall EM, Sagi HC. Selective screw placement in forearm compression plating: results of 75 consecutive fractures stabilized with 4 cortices of screw fixation on either side of the fracture. J Orthop Trauma. 2006;20(3):157–62. discussion 162–163.PubMedCrossRef Lindvall EM, Sagi HC. Selective screw placement in forearm compression plating: results of 75 consecutive fractures stabilized with 4 cortices of screw fixation on either side of the fracture. J Orthop Trauma. 2006;20(3):157–62. discussion 162–163.PubMedCrossRef
18.
go back to reference Mann RJ, Black D, Constine R, et al. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg [Am]. 1985;10(6 Pt 2):1024–8.CrossRef Mann RJ, Black D, Constine R, et al. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg [Am]. 1985;10(6 Pt 2):1024–8.CrossRef
19.
go back to reference Meunier MJ, Hentzen E, Ryan M, et al. Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg [Am]. 2004;29(4):689–93.CrossRef Meunier MJ, Hentzen E, Ryan M, et al. Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg [Am]. 2004;29(4):689–93.CrossRef
20.
go back to reference Ochman S, Doht S, Paletta J, et al. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg [Am]. 2010;35(4):597–603.CrossRef Ochman S, Doht S, Paletta J, et al. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg [Am]. 2010;35(4):597–603.CrossRef
21.
go back to reference Opgrande JD, Westphal SA. Fractures of the hand. Orthop Clin North Am. 1983;14(4):779–92.PubMed Opgrande JD, Westphal SA. Fractures of the hand. Orthop Clin North Am. 1983;14(4):779–92.PubMed
22.
go back to reference Orbay J. Intramedullary nailing of metacarpal shaft fractures. Tech Hand Up Extrem Surg. 2005;9(2):69–73.PubMedCrossRef Orbay J. Intramedullary nailing of metacarpal shaft fractures. Tech Hand Up Extrem Surg. 2005;9(2):69–73.PubMedCrossRef
23.
go back to reference Prevel CD, Eppley BL, Jackson JR, et al. Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study. J Hand Surg [Am]. 1995;20(1):44–9.CrossRef Prevel CD, Eppley BL, Jackson JR, et al. Mini and micro plating of phalangeal and metacarpal fractures: a biomechanical study. J Hand Surg [Am]. 1995;20(1):44–9.CrossRef
24.
go back to reference Prevel CD, McCarty M, Katona T, et al. Comparative biomechanical stability of titanium bone fixation systems in metacarpal fractures. Ann Plast Surg. 1995;35(1):6–14.PubMedCrossRef Prevel CD, McCarty M, Katona T, et al. Comparative biomechanical stability of titanium bone fixation systems in metacarpal fractures. Ann Plast Surg. 1995;35(1):6–14.PubMedCrossRef
25.
go back to reference Royle SG. Rotational deformity following metacarpal fracture. J Hand Surg (Br). 1990;15(1):124–5.CrossRef Royle SG. Rotational deformity following metacarpal fracture. J Hand Surg (Br). 1990;15(1):124–5.CrossRef
26.
go back to reference Ruchelsman DE, Mudgal CS, Jupiter JB. The role of locking technology in the hand. Hand Clin. 2010;26(3):307–19.PubMedCrossRef Ruchelsman DE, Mudgal CS, Jupiter JB. The role of locking technology in the hand. Hand Clin. 2010;26(3):307–19.PubMedCrossRef
27.
go back to reference Ruedi TP, Murphy WM. AO principles of fracture management. New York: Thieme; 2000. Ruedi TP, Murphy WM. AO principles of fracture management. New York: Thieme; 2000.
28.
go back to reference Sohn RC, Jahng KH, Curtiss SB, et al. Comparison of metacarpal plating methods. J Hand Surg [Am]. 2008;33(3):316–21.CrossRef Sohn RC, Jahng KH, Curtiss SB, et al. Comparison of metacarpal plating methods. J Hand Surg [Am]. 2008;33(3):316–21.CrossRef
29.
go back to reference Stern PJ, Wieser MJ, Reilly DG. Complications of plate fixation in the hand skeleton. Clin Orthop. 1987;214:59–65.PubMed Stern PJ, Wieser MJ, Reilly DG. Complications of plate fixation in the hand skeleton. Clin Orthop. 1987;214:59–65.PubMed
30.
go back to reference Vanik RK, Weber RC, Matloub HS, et al. The comparative strengths of internal fixation techniques. J Hand Surg [Am]. 1984;9(2):216–21.CrossRef Vanik RK, Weber RC, Matloub HS, et al. The comparative strengths of internal fixation techniques. J Hand Surg [Am]. 1984;9(2):216–21.CrossRef
31.
go back to reference Waris E, Ashammakhi N, Happonen H, et al. Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop. 2003;410:310–9.PubMedCrossRef Waris E, Ashammakhi N, Happonen H, et al. Bioabsorbable miniplating versus metallic fixation for metacarpal fractures. Clin Orthop. 2003;410:310–9.PubMedCrossRef
32.
go back to reference Waris E, Ashammakhi N, Raatikainen T, et al. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg [Am]. 2002;27(5):902–9.CrossRef Waris E, Ashammakhi N, Raatikainen T, et al. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg [Am]. 2002;27(5):902–9.CrossRef
Metadata
Title
Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary?
Authors
Cameron Barr
Anthony W Behn
Jeffrey Yao
Publication date
01-12-2013
Publisher
Springer US
Published in
HAND / Issue 4/2013
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-013-9544-3

Other articles of this Issue 4/2013

HAND 4/2013 Go to the issue