Skip to main content
Top
Published in: International Ophthalmology 11/2019

01-11-2019 | Pediatric Ophthalmology | Original Paper

Macular spectral-domain optical coherence tomography values and correlations in healthy children

Authors: Andrea Passani, Angela Tindara Sframeli, Chiara Posarelli, Domenico Lisi, Gianluca Guidi, Giamberto Casini, Antonio Ferreras, Michele Figus

Published in: International Ophthalmology | Issue 11/2019

Login to get access

Abstract

Purpose

The aim of this study is to investigate potential correlations between age, gender, spherical equivalent and optical coherence tomography (OCT) retinal parameters among healthy children.

Methods

A macular spectral-domain OCT was performed in all patients using a Spectralis® OCT device, and the macular thickness and volume of each of the early treatment diabetic retinopathy study (ETDRS) subfields were analysed.

Results

Ninety-four children were enrolled. Mean central macular thickness was 274.968 ± 18.28 µm, while mean central macular volume was 0.216 mm3. Statistical analysis showed a significant correlation between the factor age and central macular thickness (F(3,90) = 4.96, p = 0.003, η2 = 0.14) and central macular volume (F(3,90) = 4.98, p = 0.003, η2 = 0.14). Statistical analysis showed a significant correlation between the factor gender and macular thickness/volume of several ETDRS subfields. A significant correlation between refractive error and macular thickness/volume was also noted.

Conclusions

This study shows significant correlations between macular thickness/volume and the factors age, gender and spherical equivalent. Paediatric spectral-domain optical coherence tomography ranges need further investigations since many significant correlations are still to be confirmed.
Literature
1.
go back to reference Huang D, Swanson EA, Lin CP et al (1991) Optical coherence tomography. Science 254:1178–1181CrossRef Huang D, Swanson EA, Lin CP et al (1991) Optical coherence tomography. Science 254:1178–1181CrossRef
2.
go back to reference Fercher AF, Hitzenberger CK, Drexler W, Kamp G, Sattmann H (1993) In-vivo optical coherence tomography. Am J Ophthalmol 116:113–115CrossRef Fercher AF, Hitzenberger CK, Drexler W, Kamp G, Sattmann H (1993) In-vivo optical coherence tomography. Am J Ophthalmol 116:113–115CrossRef
3.
go back to reference Puliafito CA, Hee MR, Lin CP et al (1995) Imaging of macular diseases with optical coherence tomography. Ophthalmology 102:217–229CrossRef Puliafito CA, Hee MR, Lin CP et al (1995) Imaging of macular diseases with optical coherence tomography. Ophthalmology 102:217–229CrossRef
4.
go back to reference Wojtkowski M, Leitgeb R, Kowalczyk A, Bajraszewski T, Fercher AF (2002) In vivo human retinal imaging by Fourier domain optical coherence tomography. J Biomed Opt 7:457–463CrossRef Wojtkowski M, Leitgeb R, Kowalczyk A, Bajraszewski T, Fercher AF (2002) In vivo human retinal imaging by Fourier domain optical coherence tomography. J Biomed Opt 7:457–463CrossRef
5.
go back to reference De Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE (2003) Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt Lett 28:2067–2069CrossRef De Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE (2003) Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt Lett 28:2067–2069CrossRef
6.
go back to reference Choma MA, Sarunic MV, Yang CH, Izatt J (2003) Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt Express 11:2183–2189CrossRef Choma MA, Sarunic MV, Yang CH, Izatt J (2003) Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt Express 11:2183–2189CrossRef
7.
go back to reference Drexler W, Sattmann H, Hermann B et al (2003) Enhanced visualization of macular pathology with the use of ultrahigh resolution optical coherence tomography. Arch Ophthalmol 121:695–706CrossRef Drexler W, Sattmann H, Hermann B et al (2003) Enhanced visualization of macular pathology with the use of ultrahigh resolution optical coherence tomography. Arch Ophthalmol 121:695–706CrossRef
8.
go back to reference Salchow DJ, Oleynikov YS, Chiang MF et al (2006) Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography. Ophthalmology 113:786–791CrossRef Salchow DJ, Oleynikov YS, Chiang MF et al (2006) Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography. Ophthalmology 113:786–791CrossRef
9.
go back to reference Zhang Z, He X, Zhu J, Jiang K, Zheng W, Ke B (2011) Macular measurements using optical coherence tomography in healthy Chinese school age children. Invest Ophthalmol Vis Sci 52:6377–6383CrossRef Zhang Z, He X, Zhu J, Jiang K, Zheng W, Ke B (2011) Macular measurements using optical coherence tomography in healthy Chinese school age children. Invest Ophthalmol Vis Sci 52:6377–6383CrossRef
10.
go back to reference Leung MM, Huang RY, Lam AK (2010) Retinal nerve fiber layer thickness in normal Hong Kong chinese children measured with optical coherence tomography. J Glaucoma 19:95–99CrossRef Leung MM, Huang RY, Lam AK (2010) Retinal nerve fiber layer thickness in normal Hong Kong chinese children measured with optical coherence tomography. J Glaucoma 19:95–99CrossRef
11.
go back to reference Othman SF, Sharanjeet-Kaur, Manan FA, Zulkarnain AI, Mohamad Z, Ariffin AE (2012) Macular thickness as determined by optical coherence tomography in relation to degree of myopia, axial length and vitreous chamber depth in Malay subjects. Clin Exp Optom 95:484–491CrossRef Othman SF, Sharanjeet-Kaur, Manan FA, Zulkarnain AI, Mohamad Z, Ariffin AE (2012) Macular thickness as determined by optical coherence tomography in relation to degree of myopia, axial length and vitreous chamber depth in Malay subjects. Clin Exp Optom 95:484–491CrossRef
12.
go back to reference Turk A, Ceylan OM, Arici C et al (2012) Evaluation of the nerve fiber layer and macula in the eyes of healthy children using spectral-domain optical coherence tomography. Am J Ophthalmol 153:552–559CrossRef Turk A, Ceylan OM, Arici C et al (2012) Evaluation of the nerve fiber layer and macula in the eyes of healthy children using spectral-domain optical coherence tomography. Am J Ophthalmol 153:552–559CrossRef
13.
go back to reference Yanni SE, Wang J, Cheng CS et al (2013) Normative reference ranges for the retinal nerve fiber layer, macula, and retinal layer thicknesses in children. Am J Ophthalmol 155:354–360CrossRef Yanni SE, Wang J, Cheng CS et al (2013) Normative reference ranges for the retinal nerve fiber layer, macula, and retinal layer thicknesses in children. Am J Ophthalmol 155:354–360CrossRef
14.
go back to reference Pérez-García D, Ibañez-Alperte J, Remón L, Cristòbal JA, Sanchez-Cano A, Pinilla I (2016) Study of spectral-domain optical coherence tomography in children: normal values and influence of age, sex, and refractive status. Eur J Ophthalmol 26:135–141CrossRef Pérez-García D, Ibañez-Alperte J, Remón L, Cristòbal JA, Sanchez-Cano A, Pinilla I (2016) Study of spectral-domain optical coherence tomography in children: normal values and influence of age, sex, and refractive status. Eur J Ophthalmol 26:135–141CrossRef
15.
go back to reference Elía N, Pueyo V, Altemir I, Oros D, Pablo LE (2012) Normal reference ranges of optical coherence tomography parameters in childhood. Br J Ophthalmol 96:665–670CrossRef Elía N, Pueyo V, Altemir I, Oros D, Pablo LE (2012) Normal reference ranges of optical coherence tomography parameters in childhood. Br J Ophthalmol 96:665–670CrossRef
16.
go back to reference Barrio-Barrio J, Noval S, Galdós M et al (2013) Multicenter Spanish study of spectral-domain optical coherence tomography in normal children. Acta Ophthalmol 91:e56–e63CrossRef Barrio-Barrio J, Noval S, Galdós M et al (2013) Multicenter Spanish study of spectral-domain optical coherence tomography in normal children. Acta Ophthalmol 91:e56–e63CrossRef
17.
go back to reference Tsai DC, Huang N, Hwu JJ, Jueng RN, Chou P (2012) Estimating retinal nerve fiber layer thickness in normal schoolchildren with spectral-domain optical coherence tomography. Jpn J Ophthalmol 56:362–370CrossRef Tsai DC, Huang N, Hwu JJ, Jueng RN, Chou P (2012) Estimating retinal nerve fiber layer thickness in normal schoolchildren with spectral-domain optical coherence tomography. Jpn J Ophthalmol 56:362–370CrossRef
18.
go back to reference Hwang YH, Kim YY (2012) Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography. Clin Exp Optom 95:492–498CrossRef Hwang YH, Kim YY (2012) Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography. Clin Exp Optom 95:492–498CrossRef
Metadata
Title
Macular spectral-domain optical coherence tomography values and correlations in healthy children
Authors
Andrea Passani
Angela Tindara Sframeli
Chiara Posarelli
Domenico Lisi
Gianluca Guidi
Giamberto Casini
Antonio Ferreras
Michele Figus
Publication date
01-11-2019
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 11/2019
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-019-01085-w

Other articles of this Issue 11/2019

International Ophthalmology 11/2019 Go to the issue