Abstract

Background

Most PCR-based diagnostics are still considered time- and labor-intensive due to disparate purification, amplification, and detection steps. Advancements in PCR enzymes and buffer chemistry have increased inhibitor tolerance, facilitating PCR directly from crude samples. Obviating the need for DNA purification, while lacking a concentration step, these direct sample methods are particularly apt for human genetic testing. However, direct PCR protocols have traditionally employed thermal cyclers with slow ramp rates and conservative hold times that significantly increase an assay’s time-to-result. For this proof-of-principle study, our objective was to significantly reduce sample preparation and assay time for a PCR-based genetic test, for myotonic dystrophy type 1 (DM1), by pairing an inhibitor-resistant enzyme mix with a rapid thermal cycler to analyze samples directly in whole blood.

Methods

DM1 genetic screening was done with an adapted conventional PCR approach that employed the Streck Philisa® Thermal Cycler, the inhibitor-resistant NEBNext® High-Fidelity 2X PCR Master Mix, and agarose gel electrophoresis or an Agilent 2100 Bioanalyzer for detection. The Gene Link™ Myotonic Dystrophy Genemer™ Kit was used as a reference assay kit to evaluate the rapid assay.

Results

In this work, a rapid and direct PCR assay testing 10% whole blood as template has been developed as an exclusionary screening assay for DM1, a triple-repeat genetic disorder. PCR amplification was completed in 15 minutes using 30 cycles, including in situ hot-start/cell lysis. Out of the 40 donors screened, this assay identified 23 (57.5%) as DM1 negative suggesting no need for further testing. These data are 100% concordant with data collected using the commercially available Gene Link Genemer™ Kit per the kit-specific PCR protocol.

Conclusions

The PCR assay described in this study amplified DM1 short tandem repeats in 15 minutes. By eliminating sample purification and slower conventional PCR protocols, we demonstrated how adaptation of current PCR technology and chemistries can produce a simple-to-use exclusionary screening assay that is independent of up-front sample prep, improving a clinical lab technician’s time-to-result. We envision this direct and rapid methodology could be applied to other conventional PCR-based genetic tests and sample matrices where genomic DNA is targeted for analysis within a given molecular diagnostic platform.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bussani C, Cioni R, Mattei A, Fambrini M, Marchionni M, Scarselli G: Prenatal diagnosis of common aneuploidies in transcervical samples using quantitative fluorescent-PCR analysis. Mol Diagn Ther. 2007, 11 (2): 117-121. 10.1007/BF03256231.CrossRefPubMed Bussani C, Cioni R, Mattei A, Fambrini M, Marchionni M, Scarselli G: Prenatal diagnosis of common aneuploidies in transcervical samples using quantitative fluorescent-PCR analysis. Mol Diagn Ther. 2007, 11 (2): 117-121. 10.1007/BF03256231.CrossRefPubMed
2.
go back to reference Cursons RT, Jeyerajah E, Sleigh JW: The use of polymerase chain reaction to detect septicemia in critically ill patients. Crit Care Med. 1999, 27 (5): 937-940. 10.1097/00003246-199905000-00029.CrossRefPubMed Cursons RT, Jeyerajah E, Sleigh JW: The use of polymerase chain reaction to detect septicemia in critically ill patients. Crit Care Med. 1999, 27 (5): 937-940. 10.1097/00003246-199905000-00029.CrossRefPubMed
3.
go back to reference Deng Z, Wu G, Li Q, Zhang X, Liang Y, Li D, Gao S, Lan Y: Noninvasive genotyping of 9 Y-chromosome specific STR loci using circulatory fetal DNA in maternal plasma by multiplex PCR. Prenat Diagn. 2006, 26 (4): 362-368. 10.1002/pd.1422.CrossRefPubMed Deng Z, Wu G, Li Q, Zhang X, Liang Y, Li D, Gao S, Lan Y: Noninvasive genotyping of 9 Y-chromosome specific STR loci using circulatory fetal DNA in maternal plasma by multiplex PCR. Prenat Diagn. 2006, 26 (4): 362-368. 10.1002/pd.1422.CrossRefPubMed
4.
go back to reference Espy MJ, Uhl JR, Sloan LM, Buckwalter SP, Jones MF, Vetter EA, Yao JD, Wengenack NL, Rosenblatt JE, Cockerill FR, Smith TF: Real-time PCR in clinical microbiology: applications for routine laboratory testing. Clin Microbiol Rev. 2006, 19 (1): 165-256. 10.1128/CMR.19.1.165-256.2006.CrossRefPubMedPubMedCentral Espy MJ, Uhl JR, Sloan LM, Buckwalter SP, Jones MF, Vetter EA, Yao JD, Wengenack NL, Rosenblatt JE, Cockerill FR, Smith TF: Real-time PCR in clinical microbiology: applications for routine laboratory testing. Clin Microbiol Rev. 2006, 19 (1): 165-256. 10.1128/CMR.19.1.165-256.2006.CrossRefPubMedPubMedCentral
5.
go back to reference Lo YM, Leung TN, Tein MS, Sargent IL, Zhang J, Lau TK, Haines CJ, Redman CW: Quantitative abnormalities of fetal DNA in maternal serum in preeclampsia. Clin Chem. 1999, 45 (2): 184-188.PubMed Lo YM, Leung TN, Tein MS, Sargent IL, Zhang J, Lau TK, Haines CJ, Redman CW: Quantitative abnormalities of fetal DNA in maternal serum in preeclampsia. Clin Chem. 1999, 45 (2): 184-188.PubMed
6.
go back to reference Rautenberg P, Lubbert C, Weers W, Boetel E, Schweichler J, Zhou L, Costard-Jackle A, Kraemer-Hansen H, Harder TC: Evaluation of the AmpliSensor PCR and the SHARP signal detection system for the early prediction of symptomatic CMV infection in solid transplant recipients. J Clin Virol. 1999, 13 (1–2): 81-94. 10.1016/S1386-6532(99)00013-X.CrossRefPubMed Rautenberg P, Lubbert C, Weers W, Boetel E, Schweichler J, Zhou L, Costard-Jackle A, Kraemer-Hansen H, Harder TC: Evaluation of the AmpliSensor PCR and the SHARP signal detection system for the early prediction of symptomatic CMV infection in solid transplant recipients. J Clin Virol. 1999, 13 (1–2): 81-94. 10.1016/S1386-6532(99)00013-X.CrossRefPubMed
7.
go back to reference Robertson JM, Walsh-Weller J: An introduction to PCR primer design and optimization of amplification reactions. Methods Mol Biol. 1998, 98: 121-154.PubMed Robertson JM, Walsh-Weller J: An introduction to PCR primer design and optimization of amplification reactions. Methods Mol Biol. 1998, 98: 121-154.PubMed
8.
go back to reference Kranaster R, Marx A: Engineered DNA polymerases in biotechnology. Chembiochem. 2010, 11 (15): 2077-2084. 10.1002/cbic.201000215.CrossRefPubMed Kranaster R, Marx A: Engineered DNA polymerases in biotechnology. Chembiochem. 2010, 11 (15): 2077-2084. 10.1002/cbic.201000215.CrossRefPubMed
9.
go back to reference Dauphin LA, Hutchins RJ, Bost LA, Bowen MD: Evaluation of automated and manual commercial DNA extraction methods for recovery of Brucella DNA from suspensions and spiked swabs. J Clin Microbiol. 2009, 47 (12): 3920-3926. 10.1128/JCM.01288-09.CrossRefPubMedPubMedCentral Dauphin LA, Hutchins RJ, Bost LA, Bowen MD: Evaluation of automated and manual commercial DNA extraction methods for recovery of Brucella DNA from suspensions and spiked swabs. J Clin Microbiol. 2009, 47 (12): 3920-3926. 10.1128/JCM.01288-09.CrossRefPubMedPubMedCentral
10.
go back to reference Dauphin LA, Moser BD, Bowen MD: Evaluation of five commercial nucleic acid extraction kits for their ability to inactivate Bacillus anthracis spores and comparison of DNA yields from spores and spiked environmental samples. J Microbiol Methods. 2009, 76 (1): 30-37. 10.1016/j.mimet.2008.09.004.CrossRefPubMed Dauphin LA, Moser BD, Bowen MD: Evaluation of five commercial nucleic acid extraction kits for their ability to inactivate Bacillus anthracis spores and comparison of DNA yields from spores and spiked environmental samples. J Microbiol Methods. 2009, 76 (1): 30-37. 10.1016/j.mimet.2008.09.004.CrossRefPubMed
11.
go back to reference Kramvis A, Bukofzer S, Kew MC: Comparison of hepatitis B virus DNA extractions from serum by the QIAamp blood kit, GeneReleaser, and the phenol-chloroform method. J Clin Microbiol. 1996, 34 (11): 2731-2733.PubMedPubMedCentral Kramvis A, Bukofzer S, Kew MC: Comparison of hepatitis B virus DNA extractions from serum by the QIAamp blood kit, GeneReleaser, and the phenol-chloroform method. J Clin Microbiol. 1996, 34 (11): 2731-2733.PubMedPubMedCentral
12.
go back to reference Schuurman T, van Breda A, de Boer R, Kooistra-Smid M, Beld M, Savelkoul P, Boom R: Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit. J Clin Microbiol. 2005, 43 (9): 4616-4622. 10.1128/JCM.43.9.4616-4622.2005.CrossRefPubMedPubMedCentral Schuurman T, van Breda A, de Boer R, Kooistra-Smid M, Beld M, Savelkoul P, Boom R: Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit. J Clin Microbiol. 2005, 43 (9): 4616-4622. 10.1128/JCM.43.9.4616-4622.2005.CrossRefPubMedPubMedCentral
13.
go back to reference Zhang Z, Kermekchiev MB, Barnes WM: Direct DNA amplification from crude clinical samples using a PCR enhancer cocktail and novel mutants of Taq. J Mol Diagn. 2010, 12 (2): 152-161. 10.2353/jmoldx.2010.090070.CrossRefPubMedPubMedCentral Zhang Z, Kermekchiev MB, Barnes WM: Direct DNA amplification from crude clinical samples using a PCR enhancer cocktail and novel mutants of Taq. J Mol Diagn. 2010, 12 (2): 152-161. 10.2353/jmoldx.2010.090070.CrossRefPubMedPubMedCentral
14.
go back to reference Kermekchiev MB, Kirilova LI, Vail EE, Barnes WM: Mutants of Taq DNA polymerase resistant to PCR inhibitors allow DNA amplification from whole blood and crude soil samples. Nucleic Acids Res. 2009, 37 (5): e40-10.1093/nar/gkn1055.CrossRefPubMedPubMedCentral Kermekchiev MB, Kirilova LI, Vail EE, Barnes WM: Mutants of Taq DNA polymerase resistant to PCR inhibitors allow DNA amplification from whole blood and crude soil samples. Nucleic Acids Res. 2009, 37 (5): e40-10.1093/nar/gkn1055.CrossRefPubMedPubMedCentral
15.
go back to reference Schrader C, Schielke A, Ellerbroek L, Johne R: PCR inhibitors - occurrence, properties and removal. J Appl Microbiol. 2012, 113 (5): 1014-1026. 10.1111/j.1365-2672.2012.05384.x.CrossRefPubMed Schrader C, Schielke A, Ellerbroek L, Johne R: PCR inhibitors - occurrence, properties and removal. J Appl Microbiol. 2012, 113 (5): 1014-1026. 10.1111/j.1365-2672.2012.05384.x.CrossRefPubMed
16.
go back to reference Wang Y, Prosen DE, Mei L, Sullivan JCM, Vander Horn PB: A novel strategy to engineer DNA polymerases for enhanced processivity and improved performance in vitro. Nucleic Acids Res. 2004, 32 (3): 1197-1207. 10.1093/nar/gkh271.CrossRefPubMedPubMedCentral Wang Y, Prosen DE, Mei L, Sullivan JCM, Vander Horn PB: A novel strategy to engineer DNA polymerases for enhanced processivity and improved performance in vitro. Nucleic Acids Res. 2004, 32 (3): 1197-1207. 10.1093/nar/gkh271.CrossRefPubMedPubMedCentral
17.
go back to reference Loh E, Choe J, Loeb LA: Highly tolerated amino acid substitutions increase the fidelity of Escherichia coli DNA polymerase I. J Biol Chem. 2007, 282 (16): 12201-12209. 10.1074/jbc.M611294200.CrossRefPubMed Loh E, Choe J, Loeb LA: Highly tolerated amino acid substitutions increase the fidelity of Escherichia coli DNA polymerase I. J Biol Chem. 2007, 282 (16): 12201-12209. 10.1074/jbc.M611294200.CrossRefPubMed
18.
go back to reference Aboud M, Oh HH, McCord B: Rapid direct PCR for forensic genotyping in under 25 min. Electrophoresis. 2013, 34 (11): 1539-1547. 10.1002/elps.201200570.CrossRefPubMed Aboud M, Oh HH, McCord B: Rapid direct PCR for forensic genotyping in under 25 min. Electrophoresis. 2013, 34 (11): 1539-1547. 10.1002/elps.201200570.CrossRefPubMed
19.
go back to reference Kamsteeg EJ, Kress W, Catalli C, Hertz JM, Witsch-Baumgartner M, Buckley MF, van Engelen BG, Schwartz M, Scheffer H: Best practice guidelines and recommendations on the molecular diagnosis of myotonic dystrophy types 1 and 2. Eur J Hum Genet. 2012, 20 (12): 1203-1208. 10.1038/ejhg.2012.108.CrossRefPubMedPubMedCentral Kamsteeg EJ, Kress W, Catalli C, Hertz JM, Witsch-Baumgartner M, Buckley MF, van Engelen BG, Schwartz M, Scheffer H: Best practice guidelines and recommendations on the molecular diagnosis of myotonic dystrophy types 1 and 2. Eur J Hum Genet. 2012, 20 (12): 1203-1208. 10.1038/ejhg.2012.108.CrossRefPubMedPubMedCentral
20.
go back to reference Brook JD, McCurrach ME, Harley HG, Buckler AJ, Church D, Aburatani H, Hunter K, Stanton VP, Thirion JP, Hudson T: Molecular basis of myotonic dystrophy: expansion of a trinucleotide (CTG) repeat at the 3′ end of a transcript encoding a protein kinase family member. Cell. 1992, 69 (2): 385-10.1016/0092-8674(92)90418-C.CrossRefPubMed Brook JD, McCurrach ME, Harley HG, Buckler AJ, Church D, Aburatani H, Hunter K, Stanton VP, Thirion JP, Hudson T: Molecular basis of myotonic dystrophy: expansion of a trinucleotide (CTG) repeat at the 3′ end of a transcript encoding a protein kinase family member. Cell. 1992, 69 (2): 385-10.1016/0092-8674(92)90418-C.CrossRefPubMed
21.
go back to reference Prior TW, American College of Medical Genetics Laboratory Quality Assurance C: Technical standards and guidelines for myotonic dystrophy type 1 testing. Genet Med. 2009, 11 (7): 552-555. 10.1097/GIM.0b013e3181abce0f.CrossRefPubMed Prior TW, American College of Medical Genetics Laboratory Quality Assurance C: Technical standards and guidelines for myotonic dystrophy type 1 testing. Genet Med. 2009, 11 (7): 552-555. 10.1097/GIM.0b013e3181abce0f.CrossRefPubMed
Metadata
Title
PCR amplification of a triple-repeat genetic target directly from whole blood in 15 minutes as a proof-of-principle PCR study for direct sample analysis for a clinically relevant target
Authors
Christopher M Connelly
Laura R Porter
Joel R TerMaat
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Medical Genetics / Issue 1/2014
Electronic ISSN: 1471-2350
DOI
https://doi.org/10.1186/s12881-014-0130-5

Other articles of this Issue 1/2014

BMC Medical Genetics 1/2014 Go to the issue