Published in: European Journal of Pediatrics 9/2023

Open Access 17-07-2023 | Patent Ductus Arteriosus | RESEARCH

Impact of patent ductus arteriosus on non-invasive assessments of lung fluids in very preterm infants during the transitional period

Authors: Silvia Martini, Italo Francesco Gatelli, Ottavio Vitelli, Francesca Vitali, Francesca De Rienzo, Roberta Parladori, Luigi Corvaglia, Stefano Martinelli

Published in: European Journal of Pediatrics | Issue 9/2023

Login to get access

Abstract

This prospective observational study aimed to evaluate whether lung fluids, assessed by lung ultrasonography and transthoracic electrical bioimpedance (TEB), may be influenced by the presence of a haemodynamically significant patent ductus arteriosus (hsPDA) in very preterm infants during the transitional period. Infants < 32 weeks of gestational age (GA) admitted to the neonatal intensive care units of IRCCS AOU Bologna and Niguarda Metropolitan Hospital of Milan (Italy) underwent a daily assessment of a lung ultrasound score (LUS) and of a TEB-derived index of thoracic fluid contents (TFC) during the first 72 h after birth. Echocardiographic scans were simultaneously performed to evaluate the concomitant ductal status (hsPDA vs. restrictive or closed duct). The correlation between LUS, TFC, and the ductal status was tested using generalized estimating equations. Forty-six infants (median GA: 29 [interquartile range, IQR: 27–31] weeks; median birth weight: 1099 [IQR: 880–1406] g) were included. At each daily evaluation, the presence of a hsPDA was associated with significantly higher LUS and TFC compared with a restrictive or closed ductus (p < 0.01 for all comparisons). These results were confirmed significant even after adjustment for GA and for the ongoing modality of respiratory support.
 Conclusion: Even during the first 72 h of life, the presence of a hsPDA determines a significant increase in pulmonary fluids which can be non-invasively detected and monitored over time using lung ultrasonography and TEB.
What is Known:
• Lung ultrasonography provides a non-invasive assessment of lung fluids and is widely used in neonatal settings.
In preterm infants, the persistence of a haemodynamically significant patent ductus arteriosus (hsPDA) over the first weeks can negatively affect pulmonary outcomes.
What is New:
The presence of aan hsPDA is associated with increased lung fluids since early postnatal phases.
Lung ultrasonography and transthoracic electrical bioimpedance can effectively monitor lung fluid clearance in preterm infants with a hsPDA during the transitional period, with potential clinical implications.
Literature
1.
go back to reference Liu C, Zhu X, Li D, Shi Y (2020) Related factors of patent ductus arteriosus in preterm infants: a systematic review and meta-analysis. Front Pediatr 8:605879CrossRefPubMed Liu C, Zhu X, Li D, Shi Y (2020) Related factors of patent ductus arteriosus in preterm infants: a systematic review and meta-analysis. Front Pediatr 8:605879CrossRefPubMed
2.
go back to reference Raimondi F, Yousef N, Migliaro F, Capasso L, De Luca D (2021) Point-of-care lung ultrasound in neonatology: classification into descriptive and functional applications. Pediatr Res 90(3):524–531CrossRefPubMed Raimondi F, Yousef N, Migliaro F, Capasso L, De Luca D (2021) Point-of-care lung ultrasound in neonatology: classification into descriptive and functional applications. Pediatr Res 90(3):524–531CrossRefPubMed
3.
4.
go back to reference Paviotti G, De Cunto A, Moressa V, Bettiol C, Demarini S (2017) Thoracic fluid content by electric bioimpedance correlates with respiratory distress in newborns. J Perinatol 37(9):1024–1027CrossRefPubMed Paviotti G, De Cunto A, Moressa V, Bettiol C, Demarini S (2017) Thoracic fluid content by electric bioimpedance correlates with respiratory distress in newborns. J Perinatol 37(9):1024–1027CrossRefPubMed
5.
go back to reference Martini S, Gatelli IF, Vitelli O, Galletti S, Camela F, De Rienzo F et al (2023) Prediction of respiratory distress severity and bronchopulmonary dysplasia by lung ultrasounds and transthoracic electrical bioimpedance. Eur J Pediatr 182(3):1039–1047CrossRefPubMed Martini S, Gatelli IF, Vitelli O, Galletti S, Camela F, De Rienzo F et al (2023) Prediction of respiratory distress severity and bronchopulmonary dysplasia by lung ultrasounds and transthoracic electrical bioimpedance. Eur J Pediatr 182(3):1039–1047CrossRefPubMed
6.
go back to reference De Luca D, van Kaam AH, Tingay DG, Courtney SE, Danhaive O, Carnielli VP et al (2017) The Montreux definition of neonatal ARDS: biological and clinical background behind the description of a new entity. Lancet Respir Med 5:657–666CrossRefPubMed De Luca D, van Kaam AH, Tingay DG, Courtney SE, Danhaive O, Carnielli VP et al (2017) The Montreux definition of neonatal ARDS: biological and clinical background behind the description of a new entity. Lancet Respir Med 5:657–666CrossRefPubMed
7.
go back to reference Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A et al (2019) European consensus guidelines on the management of respiratory distress syndrome - 2019 update. Neonatology 115:432–450CrossRefPubMed Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Te Pas A et al (2019) European consensus guidelines on the management of respiratory distress syndrome - 2019 update. Neonatology 115:432–450CrossRefPubMed
8.
go back to reference Brat R, Yousef N, Klifa R, Reynaud S, Shankar Aguilera S, De Luca D (2015) Lung ultrasonography score to evaluate oxygenation and surfactant need in neonates treated with continuous positive airway pressure. JAMA Pediatr 169(8):e151797CrossRefPubMed Brat R, Yousef N, Klifa R, Reynaud S, Shankar Aguilera S, De Luca D (2015) Lung ultrasonography score to evaluate oxygenation and surfactant need in neonates treated with continuous positive airway pressure. JAMA Pediatr 169(8):e151797CrossRefPubMed
9.
go back to reference Boet A, Jourdain G, Demontoux S, De Luca D (2016) Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates. J Perinatol 36(9):748–752CrossRefPubMed Boet A, Jourdain G, Demontoux S, De Luca D (2016) Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates. J Perinatol 36(9):748–752CrossRefPubMed
10.
go back to reference Corsini I, Parri N, Gozzini E, Coviello C, Leonardi V, Poggi C et al (2019) Lung ultrasound for the differential diagnosis of respiratory distress in neonates. Neonatology 115(1):77–84CrossRefPubMed Corsini I, Parri N, Gozzini E, Coviello C, Leonardi V, Poggi C et al (2019) Lung ultrasound for the differential diagnosis of respiratory distress in neonates. Neonatology 115(1):77–84CrossRefPubMed
11.
go back to reference Raimondi F, Migliaro F, Corsini I, Meneghin F, Dolce P, Pierri L et al (2021) Lung ultrasound score progress in neonatal respiratory distress syndrome. Pediatrics 147(4) Raimondi F, Migliaro F, Corsini I, Meneghin F, Dolce P, Pierri L et al (2021) Lung ultrasound score progress in neonatal respiratory distress syndrome. Pediatrics 147(4)
12.
go back to reference Savoia M, McNamara PJ, Titolo A, Cattarossi L (2022) Lung ultrasound score parallels trends in systemic haemodynamics after PDA ligation: a case series. Eur J Pediatr 181(6):2541–2546CrossRefPubMed Savoia M, McNamara PJ, Titolo A, Cattarossi L (2022) Lung ultrasound score parallels trends in systemic haemodynamics after PDA ligation: a case series. Eur J Pediatr 181(6):2541–2546CrossRefPubMed
13.
go back to reference Francescato G, Capolupo I, Cerbo RM, Doni D, Ficial B, Fiocchi S et al (2023) Fluid restriction in management of patent ductus arteriosus in Italy: a nationwide survey. Eur J Pediatr 182(1):393–401CrossRefPubMed Francescato G, Capolupo I, Cerbo RM, Doni D, Ficial B, Fiocchi S et al (2023) Fluid restriction in management of patent ductus arteriosus in Italy: a nationwide survey. Eur J Pediatr 182(1):393–401CrossRefPubMed
14.
go back to reference Mirza H, Garcia J, McKinley G, Hubbard L, Sensing W, Schneider J et al (2019) Duration of significant patent ductus arteriosus and bronchopulmonary dysplasia in extremely preterm infants. J Perinatol 39(12):1648–1655CrossRefPubMed Mirza H, Garcia J, McKinley G, Hubbard L, Sensing W, Schneider J et al (2019) Duration of significant patent ductus arteriosus and bronchopulmonary dysplasia in extremely preterm infants. J Perinatol 39(12):1648–1655CrossRefPubMed
Metadata
Title
Impact of patent ductus arteriosus on non-invasive assessments of lung fluids in very preterm infants during the transitional period
Authors
Silvia Martini
Italo Francesco Gatelli
Ottavio Vitelli
Francesca Vitali
Francesca De Rienzo
Roberta Parladori
Luigi Corvaglia
Stefano Martinelli
Publication date
17-07-2023
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Pediatrics / Issue 9/2023
Print ISSN: 0340-6199
Electronic ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-023-05106-w

Other articles of this Issue 9/2023

European Journal of Pediatrics 9/2023 Go to the issue