Skip to main content
Top
Published in: International Archives of Occupational and Environmental Health 3/2018

01-04-2018 | Original Article

Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types

Authors: Ana Tauste, Elena Ronda, Valborg Baste, Magne Bråtveit, Bente E. Moen, María-del-Mar Seguí Crespo

Published in: International Archives of Occupational and Environmental Health | Issue 3/2018

Login to get access

Abstract

Purpose

To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials.

Methods

Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer’s and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type.

Results

The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25–2.30), limbal redness (aRR 2.87; 1.88–4.37), lid redness (aRR 2.53; 1.35–4.73) and lid roughness (aRR 7.03; 1.31–37.82). VDT exposure > 4 h/day increased wearers’ risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%).

Conclusions

Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer’s results in all participants suggests that VDT use greatly affects tear film characteristics.
Literature
go back to reference Aakre BM, Doughty MJ (2007) Are there differences between ‘visual symptoms’ and specific ocular symptoms associated with video display terminal (VDT) use? Cont Lens Anterior Eye 30(3):174–182CrossRef Aakre BM, Doughty MJ (2007) Are there differences between ‘visual symptoms’ and specific ocular symptoms associated with video display terminal (VDT) use? Cont Lens Anterior Eye 30(3):174–182CrossRef
go back to reference Argilés M, Cardona G, Pérez-Cabré E, Rodríguez M (2015) Blink rate and incomplete blinks in six different controlled hard-copy and electronic reading conditions. Investig Opthalmol Vis Sci 56(11):6679CrossRef Argilés M, Cardona G, Pérez-Cabré E, Rodríguez M (2015) Blink rate and incomplete blinks in six different controlled hard-copy and electronic reading conditions. Investig Opthalmol Vis Sci 56(11):6679CrossRef
go back to reference Brennan NA, Coles MC, Comstock TL, Levy B (2002) A 1-year prospective clinical trial of balafilcon a (PureVision) silicone-hydrogel contact lenses used on a 30-day continuous wear schedule. Ophthalmology 109(6):1172–1177CrossRef Brennan NA, Coles MC, Comstock TL, Levy B (2002) A 1-year prospective clinical trial of balafilcon a (PureVision) silicone-hydrogel contact lenses used on a 30-day continuous wear schedule. Ophthalmology 109(6):1172–1177CrossRef
go back to reference Chu CA, Rosenfield M, Portello JK (2014) Blink patterns: reading from a computer screen versus hard copy. Optom Vis Sci 91(3):297–302 Chu CA, Rosenfield M, Portello JK (2014) Blink patterns: reading from a computer screen versus hard copy. Optom Vis Sci 91(3):297–302
go back to reference de Kluizenaar Y, Roda C, Dijkstra NE, Fossati S, Mandin C, Mihucz VG, Bluyssen PM (2016) Office characteristics and dry eye complaints in European workers–The OFFICAIR study. Build Environ 102(Supplement C):54–63CrossRef de Kluizenaar Y, Roda C, Dijkstra NE, Fossati S, Mandin C, Mihucz VG, Bluyssen PM (2016) Office characteristics and dry eye complaints in European workers–The OFFICAIR study. Build Environ 102(Supplement C):54–63CrossRef
go back to reference Dumbleton KA, Chalmers RL, Richter DB, Fonn D (2001) Vascular response to extended wear of hydrogel lenses with high and low oxygen permeability. Optom Vis Sci 78(3):147–151CrossRef Dumbleton KA, Chalmers RL, Richter DB, Fonn D (2001) Vascular response to extended wear of hydrogel lenses with high and low oxygen permeability. Optom Vis Sci 78(3):147–151CrossRef
go back to reference Dumbleton K, Keir N, Moezzi A, Feng Y, Jones L, Fonn D (2006) Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses. Optom Vis Sci 83(10):758–768CrossRef Dumbleton K, Keir N, Moezzi A, Feng Y, Jones L, Fonn D (2006) Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses. Optom Vis Sci 83(10):758–768CrossRef
go back to reference González-Méijome JM, Parafita MA, Yebra-Pimentel E, Almeida JB (2007) Symptoms in a population of contact lens and noncontact lens wearers under different environmental conditions. Optom Vis Sci 84(4):296–302CrossRef González-Méijome JM, Parafita MA, Yebra-Pimentel E, Almeida JB (2007) Symptoms in a population of contact lens and noncontact lens wearers under different environmental conditions. Optom Vis Sci 84(4):296–302CrossRef
go back to reference Hirota M, Uozato H, Kawamorita T, Shibata Y, Yamamoto S (2013) Effect of incomplete blinking on tear film stability. Optom Vis Sci 90(7):650–657CrossRef Hirota M, Uozato H, Kawamorita T, Shibata Y, Yamamoto S (2013) Effect of incomplete blinking on tear film stability. Optom Vis Sci 90(7):650–657CrossRef
go back to reference Jones L, Senchyna M, Glasier M-A, Schickler J, Forbes I, Louie D et al (2003) Lysozyme and lipid deposition on silicone hydrogel contact lens materials. Eye Contact Lens 29(1):S75–S79CrossRef Jones L, Senchyna M, Glasier M-A, Schickler J, Forbes I, Louie D et al (2003) Lysozyme and lipid deposition on silicone hydrogel contact lens materials. Eye Contact Lens 29(1):S75–S79CrossRef
go back to reference Kallarackal GU, Ansari EA, Amos N, Martin JC, Lane C, Camilleri JP (2002) A comparative study to assess the clinical use of fluorescein meniscus time (FMT) with tear break up time (TBUT) and Schirmer’s tests (ST) in the diagnosis of dry eyes. Eye 16(5):594–600CrossRef Kallarackal GU, Ansari EA, Amos N, Martin JC, Lane C, Camilleri JP (2002) A comparative study to assess the clinical use of fluorescein meniscus time (FMT) with tear break up time (TBUT) and Schirmer’s tests (ST) in the diagnosis of dry eyes. Eye 16(5):594–600CrossRef
go back to reference Kojima T, Ibrahim OMA, Wakamatsu T, Tsuyama A, Ogawa J, Matsumoto Y et al (2011) The impact of contact lens wear and visual display terminal work on ocular surface and tear functions in office workers. Am J Ophthalmol 152(6):933–940CrossRef Kojima T, Ibrahim OMA, Wakamatsu T, Tsuyama A, Ogawa J, Matsumoto Y et al (2011) The impact of contact lens wear and visual display terminal work on ocular surface and tear functions in office workers. Am J Ophthalmol 152(6):933–940CrossRef
go back to reference Lemp MA, Bielory L (2008) Contact lenses and associated anterior segment disorders: dry eye disease, blepharitis, and allergy. Immunol Allergy Clin N Am 28(1):105–117 Lemp MA, Bielory L (2008) Contact lenses and associated anterior segment disorders: dry eye disease, blepharitis, and allergy. Immunol Allergy Clin N Am 28(1):105–117
go back to reference Li N, Deng X-G, He M-F (2012) Comparison of the Schirmer I test with and without topical anesthesia for diagnosing dry eye. Int J Ophthalmol 5(4):478–481 Li N, Deng X-G, He M-F (2012) Comparison of the Schirmer I test with and without topical anesthesia for diagnosing dry eye. Int J Ophthalmol 5(4):478–481
go back to reference Lin MC, Yeh TN (2013) Mechanical complications induced by silicone hydrogel contact lenses. Eye Contact Lens 39(1):115–124CrossRef Lin MC, Yeh TN (2013) Mechanical complications induced by silicone hydrogel contact lenses. Eye Contact Lens 39(1):115–124CrossRef
go back to reference Luensmann D, Jones L (2012) Protein deposition on contact lenses: the past, the present, and the future. Cont Lens Anterior Eye 35(2):53–64CrossRef Luensmann D, Jones L (2012) Protein deposition on contact lenses: the past, the present, and the future. Cont Lens Anterior Eye 35(2):53–64CrossRef
go back to reference Maldonado-Codina C, Morgan PB, Schnider CM, Efron N (2004) Short-term physiologic response in neophyte subjects fitted with hydrogel and silicone hydrogel contact lenses. Optom Vis Sci 81(12):911–921 Maldonado-Codina C, Morgan PB, Schnider CM, Efron N (2004) Short-term physiologic response in neophyte subjects fitted with hydrogel and silicone hydrogel contact lenses. Optom Vis Sci 81(12):911–921
go back to reference Maldonado-Codina C, Morgan PB, Efron N, Efron S (2005) Comparative clinical performance of rigid versus soft hyper Dk contact lenses used for continuous wear. Optom Vis Sci 82(6):536–548CrossRef Maldonado-Codina C, Morgan PB, Efron N, Efron S (2005) Comparative clinical performance of rigid versus soft hyper Dk contact lenses used for continuous wear. Optom Vis Sci 82(6):536–548CrossRef
go back to reference Nakamura S, Kinoshita S, Yokoi N, Ogawa Y, Shibuya M, Nakashima H et al (2010) Lacrimal hypofunction as a new mechanism of dry eye in visual display terminal users. Chakravarti S, editor. PLoS One 5(6):e11119CrossRef Nakamura S, Kinoshita S, Yokoi N, Ogawa Y, Shibuya M, Nakashima H et al (2010) Lacrimal hypofunction as a new mechanism of dry eye in visual display terminal users. Chakravarti S, editor. PLoS One 5(6):e11119CrossRef
go back to reference Nichols JJ, Sinnott LT (2006) Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye. Invest Ophthalmol Vis Sci 47(4):1319–1328CrossRef Nichols JJ, Sinnott LT (2006) Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye. Invest Ophthalmol Vis Sci 47(4):1319–1328CrossRef
go back to reference Nichols JJ, Sinnott LT (2011) Tear film, contact lens, and patient factors associated with corneal staining. Invest Ophthalmol Vis Sci 52(2):1127CrossRef Nichols JJ, Sinnott LT (2011) Tear film, contact lens, and patient factors associated with corneal staining. Invest Ophthalmol Vis Sci 52(2):1127CrossRef
go back to reference Orsborn GN, Zantos SG (1988) Corneal desiccation staining with thin high water content contact lenses. CLAO J 14(2):81–85 Orsborn GN, Zantos SG (1988) Corneal desiccation staining with thin high water content contact lenses. CLAO J 14(2):81–85
go back to reference Portello JK, Rosenfield M, Chu CA (2013) Blink rate, incomplete blinks and computer vision syndrome. Optomet Vis Sci 90(5):482–487CrossRef Portello JK, Rosenfield M, Chu CA (2013) Blink rate, incomplete blinks and computer vision syndrome. Optomet Vis Sci 90(5):482–487CrossRef
go back to reference Riley C, Young G, Chalmers R (2006) Prevalence of ocular surface symptoms, signs, and uncomfortable hours of wear in contact lens wearers: the effect of refitting with daily-wear silicone hydrogel lenses (senofilcon a): eye and contact lens. Sci Clini Pract 32(6):281–286 Riley C, Young G, Chalmers R (2006) Prevalence of ocular surface symptoms, signs, and uncomfortable hours of wear in contact lens wearers: the effect of refitting with daily-wear silicone hydrogel lenses (senofilcon a): eye and contact lens. Sci Clini Pract 32(6):281–286
go back to reference Sankaridurg PR, Sweeney DF, Sharma S, Gora R, Naduvilath T, Ramachandran L et al (1999) Adverse events with extended wear of disposable hydrogels: results for the first 13 months of lens wear. Ophthalmology 106(9):1671–1680CrossRef Sankaridurg PR, Sweeney DF, Sharma S, Gora R, Naduvilath T, Ramachandran L et al (1999) Adverse events with extended wear of disposable hydrogels: results for the first 13 months of lens wear. Ophthalmology 106(9):1671–1680CrossRef
go back to reference Sankaridurg P, Lazon de la Jara P, Holden B (2013 Jan) The future of silicone hydrogels. Eye Contact Lens 39(1):125–129CrossRef Sankaridurg P, Lazon de la Jara P, Holden B (2013 Jan) The future of silicone hydrogels. Eye Contact Lens 39(1):125–129CrossRef
go back to reference Santodomingo J, Villa C, Morgan P (2015) Lentes de contacto adaptadas en España en 2014: comparación con otros países. Gaceta de Optometría y Óptica Oftálmica. 2:74–81 Santodomingo J, Villa C, Morgan P (2015) Lentes de contacto adaptadas en España en 2014: comparación con otros países. Gaceta de Optometría y Óptica Oftálmica. 2:74–81
go back to reference Santodomingo-Rubido J (2007) The comparative clinical performance of a new polyhexamethylene biguanide—vs a polyquad-based contact lens care regime with two silicone hydrogel contact lenses. Ophthalmic Physiol Opt 27(2):168–173CrossRef Santodomingo-Rubido J (2007) The comparative clinical performance of a new polyhexamethylene biguanide—vs a polyquad-based contact lens care regime with two silicone hydrogel contact lenses. Ophthalmic Physiol Opt 27(2):168–173CrossRef
go back to reference Savini G, Prabhawasat P, Kojima T, Grueterich M, Espana E, Goto E (2008) The challenge of dry eye diagnosis. Clin Ophthalmol 2(1):31–55CrossRef Savini G, Prabhawasat P, Kojima T, Grueterich M, Espana E, Goto E (2008) The challenge of dry eye diagnosis. Clin Ophthalmol 2(1):31–55CrossRef
go back to reference Schlote T, Kadner G, Freudenthaler N (2004) Marked reduction and distinct patterns of eye blinking in patients with moderately dry eyes during video display terminal use. Graefe’s Arch Clin Exp Ophthalmol 242(4):306–312CrossRef Schlote T, Kadner G, Freudenthaler N (2004) Marked reduction and distinct patterns of eye blinking in patients with moderately dry eyes during video display terminal use. Graefe’s Arch Clin Exp Ophthalmol 242(4):306–312CrossRef
go back to reference Stapleton F, Kasses S, Bolis S, Keay L (2001) Short term wear of high Dk soft contact lenses does not alter corneal epithelial cell size or viability. Br J Ophthalmol 85(2):143–146CrossRef Stapleton F, Kasses S, Bolis S, Keay L (2001) Short term wear of high Dk soft contact lenses does not alter corneal epithelial cell size or viability. Br J Ophthalmol 85(2):143–146CrossRef
go back to reference Tagliaferri A, Love TE, Szczotka-Flynn LB (2014) Risk factors for contact lens–induced papillary conjunctivitis associated with silicone hydrogel contact lens wear. Eye Contact Lens 40(3):117–122CrossRef Tagliaferri A, Love TE, Szczotka-Flynn LB (2014) Risk factors for contact lens–induced papillary conjunctivitis associated with silicone hydrogel contact lens wear. Eye Contact Lens 40(3):117–122CrossRef
go back to reference Tauste A, Ronda E, Molina M-J, Seguí M (2016) Effect of contact lens use on computer vision syndrome. Ophthalmic Physiol Opt 36(2):112–119CrossRef Tauste A, Ronda E, Molina M-J, Seguí M (2016) Effect of contact lens use on computer vision syndrome. Ophthalmic Physiol Opt 36(2):112–119CrossRef
go back to reference Terry RL, Schnider CM, Holden BA, Cornish R, Grant T, Sweeney D et al (1993) CCLRU standards for success of daily and extended wear contact lenses. Optom Vis Sci 70(3):234–243CrossRef Terry RL, Schnider CM, Holden BA, Cornish R, Grant T, Sweeney D et al (1993) CCLRU standards for success of daily and extended wear contact lenses. Optom Vis Sci 70(3):234–243CrossRef
go back to reference Uchino M, Schaumberg DA, Dogru M, Uchino Y, Fukagawa K, Shimmura S et al (2008) Prevalence of dry eye disease among Japanese visual display terminal users. Ophthalmology 115(11):1982–1988CrossRef Uchino M, Schaumberg DA, Dogru M, Uchino Y, Fukagawa K, Shimmura S et al (2008) Prevalence of dry eye disease among Japanese visual display terminal users. Ophthalmology 115(11):1982–1988CrossRef
go back to reference Uchino M, Nishiwaki Y, Michikawa T, Shirakawa K, Kuwahara E, Yamada M et al (2011) Prevalence and risk factors of dry eye disease in Japan: Koumi study. Ophthalmology 118(12):2361–2367CrossRef Uchino M, Nishiwaki Y, Michikawa T, Shirakawa K, Kuwahara E, Yamada M et al (2011) Prevalence and risk factors of dry eye disease in Japan: Koumi study. Ophthalmology 118(12):2361–2367CrossRef
go back to reference Urgacz A, Mrukwa E, Gawlik R (2015) Adverse events in allergy sufferers wearing contact lenses. Adv Dermatol Allergol 3:204–209CrossRef Urgacz A, Mrukwa E, Gawlik R (2015) Adverse events in allergy sufferers wearing contact lenses. Adv Dermatol Allergol 3:204–209CrossRef
go back to reference van Tilborg MM, Murphy PJ, Evans KS (2017) Impact of dry eye symptoms and daily activities in a modern office. Optom Vis Sci 94(6):688–693CrossRef van Tilborg MM, Murphy PJ, Evans KS (2017) Impact of dry eye symptoms and daily activities in a modern office. Optom Vis Sci 94(6):688–693CrossRef
go back to reference Wolkoff P (2017) External eye symptoms in indoor environments. Indoor Air 27(2):246–260CrossRef Wolkoff P (2017) External eye symptoms in indoor environments. Indoor Air 27(2):246–260CrossRef
go back to reference Wu H, Wang Y, Dong N, Yang F, Lin Z, Shang X et al (2014) Meibomian gland dysfunction determines the severity of the dry eye conditions in visual display terminal workers. Sakakibara M, editor. PLoS One 9(8):e105575CrossRef Wu H, Wang Y, Dong N, Yang F, Lin Z, Shang X et al (2014) Meibomian gland dysfunction determines the severity of the dry eye conditions in visual display terminal workers. Sakakibara M, editor. PLoS One 9(8):e105575CrossRef
go back to reference Yazici A, Sari ES, Sahin G, Kilic A, Cakmak H, Ayar O et al (2015) Change in tear film characteristics in visual display terminal users. Eur J Ophthalmol 25(2):85–89CrossRef Yazici A, Sari ES, Sahin G, Kilic A, Cakmak H, Ayar O et al (2015) Change in tear film characteristics in visual display terminal users. Eur J Ophthalmol 25(2):85–89CrossRef
go back to reference Young G, Riley CM, Chalmers RL, Hunt C (2007) Hydrogel lens comfort in challenging environments and the effect of refitting with silicone hydrogel lenses. Optom Vis Sci 84(4):302–308CrossRef Young G, Riley CM, Chalmers RL, Hunt C (2007) Hydrogel lens comfort in challenging environments and the effect of refitting with silicone hydrogel lenses. Optom Vis Sci 84(4):302–308CrossRef
Metadata
Title
Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types
Authors
Ana Tauste
Elena Ronda
Valborg Baste
Magne Bråtveit
Bente E. Moen
María-del-Mar Seguí Crespo
Publication date
01-04-2018
Publisher
Springer Berlin Heidelberg
Published in
International Archives of Occupational and Environmental Health / Issue 3/2018
Print ISSN: 0340-0131
Electronic ISSN: 1432-1246
DOI
https://doi.org/10.1007/s00420-017-1283-2

Other articles of this Issue 3/2018

International Archives of Occupational and Environmental Health 3/2018 Go to the issue