Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 4/2004

01-04-2004 | Clinical Investigation

Marked reduction and distinct patterns of eye blinking in patients with moderately dry eyes during video display terminal use

Authors: Torsten Schlote, Gregor Kadner, Nora Freudenthaler

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 4/2004

Login to get access

Abstract

Purpose

To analyze the spontaneous eye-blink rate (SEBR) and blinking pattern in patients with moderately dry eyes during video display terminal (VDT) use.

Methods

The SEBR of 30 patients with dry eye syndrome (median age 44.8 years, range 18 – 67 years) was measured using a computer-based video analysis system. Only complete eye blinks were recorded during 10 min of conversation, during initial VDT use and again after a preceding work period of 30 min.

Results

In comparison with SEBR during conversation (mean value 16.8 blinks/min, standard deviation 16.8 blinks/min) the SEBR significantly decreased during initial VDT use (6.6±4.8; P<0.001) and remained significantly decreased during re-measurement after 30 min (5.9±4.6; P<0.001). SEBR was not significantly different between initial VDT use and re-measurement after 30 min (P=0.65). The SEBR was characterized by marked interindividual variability during conversation and VDT use. No significant correlation was found between SEBR (either during conversation or during VDT use), and the quality (tear break-up time) or quantity (Schirmer I test, Jones test) of the tear film. Typical blinking patterns were found to be (1) a relatively time-independent, irregular pattern, (2) an initial phase of 2–4 min with shorter inter-eye-blink intervals, and (3) alternating periods of higher and lower inter-eye-blink intervals.

Conclusions

Reduction of the SEBR during VDT use is primarily determined by marked visual attention, resulting in an exacerbation of dry eye symptoms in predisposed humans. High interindividual variability and distinct patterns of eye blinking may be key factors in further clarification of VDT–eye interactions and develop individually designed solutions to prevent desiccation during VDT use.
Literature
1.
go back to reference Acosta MC, Gallar J, Belmonte C (1999) The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals. Exp Eye Res 68: 663–669CrossRefPubMed Acosta MC, Gallar J, Belmonte C (1999) The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals. Exp Eye Res 68: 663–669CrossRefPubMed
2.
go back to reference Bron AJ (2001) Diagnosis of dry eye. Surv Ophthalmol 45 [Suppl 2]: S221–S226 Bron AJ (2001) Diagnosis of dry eye. Surv Ophthalmol 45 [Suppl 2]: S221–S226
3.
go back to reference Carney LG, Hill RM (1982) The nature of normal blinking patterns. Acta Ophthalmol Scand 60: 427–433 Carney LG, Hill RM (1982) The nature of normal blinking patterns. Acta Ophthalmol Scand 60: 427–433
4.
go back to reference Dain SJ, McCarthy AK, Chan-Ling T (1988) Symptoms in VDU operators. Am J Optom Physiol Opt 65: 162–167PubMed Dain SJ, McCarthy AK, Chan-Ling T (1988) Symptoms in VDU operators. Am J Optom Physiol Opt 65: 162–167PubMed
5.
go back to reference Doughty MJ (2001) Consideration of three types of spontaneous eyeblink activity in normal humans: during reading and video display terminal use, in primary gaze, and while in conversation. Optom Vis Sci 78: 712–725PubMed Doughty MJ (2001) Consideration of three types of spontaneous eyeblink activity in normal humans: during reading and video display terminal use, in primary gaze, and while in conversation. Optom Vis Sci 78: 712–725PubMed
6.
go back to reference Freudenthaler N, Neuf H, Kadner G, Schlote T (2003) Characteristics of spontaneous eyeblink activity during video display terminal use in healthy volunteers. Graefes Arch Clin Exp Ophthalmol 241: 914–920PubMed Freudenthaler N, Neuf H, Kadner G, Schlote T (2003) Characteristics of spontaneous eyeblink activity during video display terminal use in healthy volunteers. Graefes Arch Clin Exp Ophthalmol 241: 914–920PubMed
7.
go back to reference Hikichi T, Yoshida A, Fukui Y, Hamano T, Ri M, Araki K, Horimoto K, Takamura E, Kitagawa K, Oyama M (1995) Prevalence of dry eye in Japanese eye centers. Graefes Arch Clin Exp Ophthalmol 233: 555–558PubMed Hikichi T, Yoshida A, Fukui Y, Hamano T, Ri M, Araki K, Horimoto K, Takamura E, Kitagawa K, Oyama M (1995) Prevalence of dry eye in Japanese eye centers. Graefes Arch Clin Exp Ophthalmol 233: 555–558PubMed
8 .
go back to reference Jones LT (1966) The lacrimal secretory system and its treatment. Am J Ophthalmol 62: 47–60PubMed Jones LT (1966) The lacrimal secretory system and its treatment. Am J Ophthalmol 62: 47–60PubMed
9.
go back to reference Nakamori K, Odawara BS, Nakajimia T, Mizutani T, Tsubota K (1997) Blinking is controlled primarily by ocular surface conditions. Am J Ophthalmol 124: 24–30PubMed Nakamori K, Odawara BS, Nakajimia T, Mizutani T, Tsubota K (1997) Blinking is controlled primarily by ocular surface conditions. Am J Ophthalmol 124: 24–30PubMed
10.
go back to reference Patel S, Henderson R, Bradley L, Galloway B (1991) Effect of visual display unit use on blink rate and tear stability. Optom Vis Sci 68: 888–892PubMed Patel S, Henderson R, Bradley L, Galloway B (1991) Effect of visual display unit use on blink rate and tear stability. Optom Vis Sci 68: 888–892PubMed
11.
go back to reference Prause JU, Norn M (1987) Relation between blink frequency and break-up time. Acta Ophthalmol Scand 65: 19–22 Prause JU, Norn M (1987) Relation between blink frequency and break-up time. Acta Ophthalmol Scand 65: 19–22
12.
go back to reference Rolando M, Zierhut M (2001) The ocular surface and tear film and their dysfunction in dry eye disease. Surv Ophthalmol 45 [Suppl 2]: S203–210 Rolando M, Zierhut M (2001) The ocular surface and tear film and their dysfunction in dry eye disease. Surv Ophthalmol 45 [Suppl 2]: S203–210
13.
go back to reference Salibello C, Nilsen E (1995) Is there a typical VDT patient? A demographic analysis. J Am Optom Assoc 66: 479-483PubMed Salibello C, Nilsen E (1995) Is there a typical VDT patient? A demographic analysis. J Am Optom Assoc 66: 479-483PubMed
14.
go back to reference Schirmer O (1903) Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr. Albrecht v Graefes Arch Ophthalmol 56: 197–291 Schirmer O (1903) Studien zur Physiologie und Pathologie der Tränenabsonderung und Tränenabfuhr. Albrecht v Graefes Arch Ophthalmol 56: 197–291
15.
go back to reference Shimmura S, Shimazaki J, Tsubota K (1999) Results of a population-based questionnaire on the symptoms and lifestyles associated with dry eye. Cornea 18: 408–411PubMed Shimmura S, Shimazaki J, Tsubota K (1999) Results of a population-based questionnaire on the symptoms and lifestyles associated with dry eye. Cornea 18: 408–411PubMed
16.
go back to reference Thomson WD (1998) Eye problems and visual display terminals—the facts and the fallacies. Ophthalmic Physiol Opt 18: 111–119PubMed Thomson WD (1998) Eye problems and visual display terminals—the facts and the fallacies. Ophthalmic Physiol Opt 18: 111–119PubMed
17.
go back to reference Toda I, Fujishima H, Tsubota K (1993) Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol 71: 347–352 Toda I, Fujishima H, Tsubota K (1993) Ocular fatigue is the major symptom of dry eye. Acta Ophthalmol 71: 347–352
18.
go back to reference Tsubota K, Nakamori K (1993) Dry eyes and video display terminals. New Engl J Med 328: 584 Tsubota K, Nakamori K (1993) Dry eyes and video display terminals. New Engl J Med 328: 584
19.
go back to reference Tsubota K, Nakamori K (1995) Effects of ocular surface area and blink rate on tear dynamics. Arch Ophthalmol 113: 155–158PubMed Tsubota K, Nakamori K (1995) Effects of ocular surface area and blink rate on tear dynamics. Arch Ophthalmol 113: 155–158PubMed
20.
go back to reference Tsubota K, Hata S, Okusawa Y, Egami F, Ohtsuki T, Nakamori K (1996) Quantitative videographic analysis of blinking in normal subjects and patients with dry eye. Arch Ophthalmol 114: 715–720PubMed Tsubota K, Hata S, Okusawa Y, Egami F, Ohtsuki T, Nakamori K (1996) Quantitative videographic analysis of blinking in normal subjects and patients with dry eye. Arch Ophthalmol 114: 715–720PubMed
21.
go back to reference Yap M (1991) Tear-break-up time is related to blink frequency. Acta Ophthalmol Scand 69: 92–94 Yap M (1991) Tear-break-up time is related to blink frequency. Acta Ophthalmol Scand 69: 92–94
22.
go back to reference Zaman ML, Doughty MJ, Button NF (1998) The exposed ocular surface and its relationship to spontaneous eyeblink rate in elderly caucasians. Exp Eye Res 67: 681–686CrossRefPubMed Zaman ML, Doughty MJ, Button NF (1998) The exposed ocular surface and its relationship to spontaneous eyeblink rate in elderly caucasians. Exp Eye Res 67: 681–686CrossRefPubMed
Metadata
Title
Marked reduction and distinct patterns of eye blinking in patients with moderately dry eyes during video display terminal use
Authors
Torsten Schlote
Gregor Kadner
Nora Freudenthaler
Publication date
01-04-2004
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 4/2004
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-003-0845-z

Other articles of this Issue 4/2004

Graefe's Archive for Clinical and Experimental Ophthalmology 4/2004 Go to the issue