Skip to main content
Top
Published in: Journal of Artificial Organs 1/2013

01-03-2013 | Original Article

Observation of local elastic distribution in aortic tissues under static strain condition by use of a scanning haptic microscope

Authors: Takeshi Moriwaki, Tomonori Oie, Keiichi Takamizawa, Yoshinobu Murayama, Toru Fukuda, Sadao Omata, Yasuhide Nakayama

Published in: Journal of Artificial Organs | Issue 1/2013

Login to get access

Abstract

The purpose of this study was to observe variation in the local elastic distribution in aortic tissue walls under different static strain conditions, including physiological strain, by use of a scanning haptic microscope (SHM). Strain was applied by stretching aortic tissues in the circumferential direction by the simple tensile method or by the rod-insertion method to mimic in vivo internal pressure loading. SHM measurements in a saline solution at room temperature were performed on canine thoracic aorta using a glass needle probe with a diameter of ca 5 μm and a scanning area and point pitch of 160 × 80 μm and 2 μm, respectively. Under strain of 0–0.23, corresponding to internal pressure of 0–150 mmHg, wavy-shaped elastin fibers stretched until they were almost straightened, and the average elastic modulus increased almost linearly. Although there was little difference between the images obtained for the two different stretching methods, under high strain (>0.36; 250 mmHg) significant circumferential orientation of the collagen fibrils occurred with an increase in the average elastic modulus. It was concluded that the pressure resistance of the aorta under physiological strain was mainly afforded by elastin fibers; collagen fibrils contributed little except under much higher pressures.
Literature
1.
go back to reference Litwin SB, Cohen J, Fine S. Effects of sterilization and preservation on the rupture force and tensile strength of canine aortic tissue. J Surg Res. 1973;15:198–206.PubMedCrossRef Litwin SB, Cohen J, Fine S. Effects of sterilization and preservation on the rupture force and tensile strength of canine aortic tissue. J Surg Res. 1973;15:198–206.PubMedCrossRef
2.
go back to reference Assoul N, Flaud P, Chaouat M, Letourneur D, Bataille I. Mechanical properties of rat thoracic and abdominal aortas. J Biomech. 2008;41:2227–36.PubMedCrossRef Assoul N, Flaud P, Chaouat M, Letourneur D, Bataille I. Mechanical properties of rat thoracic and abdominal aortas. J Biomech. 2008;41:2227–36.PubMedCrossRef
3.
go back to reference Angouras DC, Dosios TJ, Dimitriou CA, Chamogeorgakis TP, Rokkas CK, Manos TA, Sokolis DP. Surgical thoracic sympathectomy induces structural and biomechanical remodeling of the thoracic aorta in a porcine model. J Surg Res. 2012;172:68–76.PubMedCrossRef Angouras DC, Dosios TJ, Dimitriou CA, Chamogeorgakis TP, Rokkas CK, Manos TA, Sokolis DP. Surgical thoracic sympathectomy induces structural and biomechanical remodeling of the thoracic aorta in a porcine model. J Surg Res. 2012;172:68–76.PubMedCrossRef
4.
go back to reference Wolinsky H, Glagov S. Structural basis for the static mechanical properties of the aortic media. Circ Res. 1964;14:400–13.PubMedCrossRef Wolinsky H, Glagov S. Structural basis for the static mechanical properties of the aortic media. Circ Res. 1964;14:400–13.PubMedCrossRef
5.
go back to reference Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J Biomech. 1980;13:175–84.PubMedCrossRef Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J Biomech. 1980;13:175–84.PubMedCrossRef
6.
go back to reference Dobrin PB, Rovick AA. Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries. Am J Physiol. 1969;217:1644–51.PubMed Dobrin PB, Rovick AA. Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries. Am J Physiol. 1969;217:1644–51.PubMed
7.
go back to reference Vaishnav RN, Young JT, Patel DJ. Distribution of stresses and of strain-energy density through the wall thickness in a canine aortic segment. Circ Res. 1973;32:577–83.PubMedCrossRef Vaishnav RN, Young JT, Patel DJ. Distribution of stresses and of strain-energy density through the wall thickness in a canine aortic segment. Circ Res. 1973;32:577–83.PubMedCrossRef
8.
go back to reference Matsumoto T, Hayashi K. Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain. J Biomech Eng. 1996;118:62–73.PubMedCrossRef Matsumoto T, Hayashi K. Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain. J Biomech Eng. 1996;118:62–73.PubMedCrossRef
10.
go back to reference Zhang Y, Hu X, Sun J, Shen Y, Hu J, Xu X, Shao Z. High-resolution imaging and nano-manipulation of biological structures on surface. Microsc Res Tech. 2011;74:614–26.PubMedCrossRef Zhang Y, Hu X, Sun J, Shen Y, Hu J, Xu X, Shao Z. High-resolution imaging and nano-manipulation of biological structures on surface. Microsc Res Tech. 2011;74:614–26.PubMedCrossRef
11.
go back to reference Yang L, van der Werf KO, Koopman BF, Subramaniam V, Bennink ML, Dijkstra PJ, Feijen J. Micromechanical bending of single collagen fibrils using atomic force microscopy. J Biomed Mater Res A. 2007;82:160–8.PubMed Yang L, van der Werf KO, Koopman BF, Subramaniam V, Bennink ML, Dijkstra PJ, Feijen J. Micromechanical bending of single collagen fibrils using atomic force microscopy. J Biomed Mater Res A. 2007;82:160–8.PubMed
12.
go back to reference Ohashi T, Kato Y, Matsumoto T, Sato M. Intramural distribution of elastic moduli in thoracic aortas and its relationship to histology: comparison between porcine and bovine thoracic aortas. JSME Int J Ser C. 1999;42:568–73.CrossRef Ohashi T, Kato Y, Matsumoto T, Sato M. Intramural distribution of elastic moduli in thoracic aortas and its relationship to histology: comparison between porcine and bovine thoracic aortas. JSME Int J Ser C. 1999;42:568–73.CrossRef
13.
go back to reference Kanai H, Hasegawa H, Ichiki M, Tezuka F, Koiwa Y. Elasticity imaging of atheroma with transcutaneous ultrasound: preliminary study. Circulation. 2003;107:3018–21.PubMedCrossRef Kanai H, Hasegawa H, Ichiki M, Tezuka F, Koiwa Y. Elasticity imaging of atheroma with transcutaneous ultrasound: preliminary study. Circulation. 2003;107:3018–21.PubMedCrossRef
14.
go back to reference Kim K, Jeong CG, Hollister SJ. Non-invasive monitoring of tissue scaffold degradation using ultrasound elasticity imaging. Acta Biomater. 2008;4:783–90.PubMedCrossRef Kim K, Jeong CG, Hollister SJ. Non-invasive monitoring of tissue scaffold degradation using ultrasound elasticity imaging. Acta Biomater. 2008;4:783–90.PubMedCrossRef
15.
go back to reference Matsumoto T, Goto T, Furukawa T, Sato M. Residual stress and strain in the lamellar unit of the porcine aorta: experiment and analysis. J Biomech. 2004;37:807–15.PubMedCrossRef Matsumoto T, Goto T, Furukawa T, Sato M. Residual stress and strain in the lamellar unit of the porcine aorta: experiment and analysis. J Biomech. 2004;37:807–15.PubMedCrossRef
16.
go back to reference Tracqui P, Broisat A, Toczek J, Mesnier N, Ohayon J, Riou L. Mapping elasticity moduli of atherosclerotic plaque in situ via atomic force microscopy. J Struct Biol. 2011;174:115–23.PubMedCrossRef Tracqui P, Broisat A, Toczek J, Mesnier N, Ohayon J, Riou L. Mapping elasticity moduli of atherosclerotic plaque in situ via atomic force microscopy. J Struct Biol. 2011;174:115–23.PubMedCrossRef
17.
go back to reference Murayama Y, Omata S. Fabrication of micro tactile sensor for the measurement of micro-scale local elasticity. Sens Actuators A. 2004;109:202–7.CrossRef Murayama Y, Omata S. Fabrication of micro tactile sensor for the measurement of micro-scale local elasticity. Sens Actuators A. 2004;109:202–7.CrossRef
18.
go back to reference Murayama Y, Constantinou CE, Omata S. Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.PubMedCrossRef Murayama Y, Constantinou CE, Omata S. Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.PubMedCrossRef
19.
go back to reference Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005;120:543–9.CrossRef Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005;120:543–9.CrossRef
20.
go back to reference Oie T, Suzuki H, Murayama Y, Fukuda T, Omata S, Kanda K, Takamizawa K, Nakayama Y. Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope. J Artif Organs. 2010;13:121–5.PubMedCrossRef Oie T, Suzuki H, Murayama Y, Fukuda T, Omata S, Kanda K, Takamizawa K, Nakayama Y. Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope. J Artif Organs. 2010;13:121–5.PubMedCrossRef
21.
go back to reference Moriwaki T, Oie T, Takamizawa K, Murayama Y, Fukuda T, Omata S, Kanda K, Nakayama Y. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM). J Artif Organs. 2011;14:276–83.PubMedCrossRef Moriwaki T, Oie T, Takamizawa K, Murayama Y, Fukuda T, Omata S, Kanda K, Nakayama Y. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM). J Artif Organs. 2011;14:276–83.PubMedCrossRef
22.
go back to reference Omata S, Terunuma Y. New tactile sensor like the human hand and its application. Sens Actuators A. 1992;35:9–15.CrossRef Omata S, Terunuma Y. New tactile sensor like the human hand and its application. Sens Actuators A. 1992;35:9–15.CrossRef
23.
go back to reference Takamizawa K, Hayashi K. Strain energy density function and uniform strain hypothesis for arterial mechanics. J Biomech. 1987;20:7–17.PubMedCrossRef Takamizawa K, Hayashi K. Strain energy density function and uniform strain hypothesis for arterial mechanics. J Biomech. 1987;20:7–17.PubMedCrossRef
24.
go back to reference Gosline J, Lillie M, Carrington E, Guerette P, Ortlepp C, Savage K. Elastic proteins: biological roles and mechanical properties. Philos Trans R Soc Lond B Biol Sci. 2002;357:121–32.PubMedCrossRef Gosline J, Lillie M, Carrington E, Guerette P, Ortlepp C, Savage K. Elastic proteins: biological roles and mechanical properties. Philos Trans R Soc Lond B Biol Sci. 2002;357:121–32.PubMedCrossRef
25.
go back to reference Matsumoto T, Sato M. Analysis of stress and strain distribution in the artery wall consisted of layers with different elastic modulus and opening angle. JSME Int J Ser C. 2002;45:906–12.CrossRef Matsumoto T, Sato M. Analysis of stress and strain distribution in the artery wall consisted of layers with different elastic modulus and opening angle. JSME Int J Ser C. 2002;45:906–12.CrossRef
Metadata
Title
Observation of local elastic distribution in aortic tissues under static strain condition by use of a scanning haptic microscope
Authors
Takeshi Moriwaki
Tomonori Oie
Keiichi Takamizawa
Yoshinobu Murayama
Toru Fukuda
Sadao Omata
Yasuhide Nakayama
Publication date
01-03-2013
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2013
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-012-0674-0

Other articles of this Issue 1/2013

Journal of Artificial Organs 1/2013 Go to the issue