Published in: Journal of Artificial Organs 2/2010

01-07-2010 | Brief Communication

Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope

Authors: Tomonori Oie, Hisato Suzuki, Yoshinobu Murayama, Toru Fukuda, Sadao Omata, Keiichi Kanda, Keiichi Takamizawa, Yasuhide Nakayama

Published in: Journal of Artificial Organs | Issue 2/2010

Login to get access

Abstract

The objective of this study was to make an elasticity distribution image of natural arteries in a liquid environment at high resolution at the micrometer level and at a wide area at the sub-square millimeter level by improving the scanning haptic microscope (SHM), developed previously for characterization of the stiffness of natural tissues. The circumferential sections (thickness, 1.0 mm) of small-caliber porcine arteries (approximately 3-mm diameter) were used as a sample. Measurement was performed by soaking a probe (diameter, 5 μm; spatial resolution, less than 2 μm) in saline solution at an appropriate depth. The vascular tissues were segregated by multi-layering a high elasticity region with mainly elastin (50.8 ± 13.8 kPa) and a low one with mainly collagen and smooth muscle cells (17.0 ± 9.0 kPa), as observed previously in high humidity conditions. The elasticity was measured repeatedly with little change for over 4 h in a liquid environment, which enabled observation with maintenance of high precision of a large area of at least 1,200 × 100 μm, whereas the elasticity was increased with time by the dehydration of samples with shrinkage in the air, in which an averaged elasticity in the overall area was approximately doubled within 2 h. This simple, inexpensive system allows observation of the distribution of the surface elasticity at the extracellular matrix level of vascular tissues in a liquid environment close to the natural one.
Literature
1.
go back to reference Egorov V, Tsyuryupa S, Kanilo S, Kogit M, Sarvazyan A. Soft tissue elastometer. Med Eng Phys. 2007;30:206–12.CrossRefPubMed Egorov V, Tsyuryupa S, Kanilo S, Kogit M, Sarvazyan A. Soft tissue elastometer. Med Eng Phys. 2007;30:206–12.CrossRefPubMed
2.
3.
go back to reference Egorov V, Sarvazyan A. Mechanical imaging of the breast. IEEE Trans Med Imaging. 2008;27:1275–87.CrossRefPubMed Egorov V, Sarvazyan A. Mechanical imaging of the breast. IEEE Trans Med Imaging. 2008;27:1275–87.CrossRefPubMed
5.
go back to reference Schaap A, Carrasco C, Pablo P, MacKintosh F, Schmidt C. Elastic response, buckling, and instability of microtubules under radial indentation. Biophys J. 2006;91:1521–31.CrossRefPubMed Schaap A, Carrasco C, Pablo P, MacKintosh F, Schmidt C. Elastic response, buckling, and instability of microtubules under radial indentation. Biophys J. 2006;91:1521–31.CrossRefPubMed
6.
go back to reference Zhao L, Schaefer D, Marten M. Assessment of elasticity and topography of Aspergillus nidulans spores via atomic force microscopy. Biophys J. 2007;92:955–60.CrossRef Zhao L, Schaefer D, Marten M. Assessment of elasticity and topography of Aspergillus nidulans spores via atomic force microscopy. Biophys J. 2007;92:955–60.CrossRef
7.
go back to reference Stolz M, Raiteri R, Daniels A, Landingham M, Baschong W, Aebi U. Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys J. 2004;86:3269–83.CrossRefPubMed Stolz M, Raiteri R, Daniels A, Landingham M, Baschong W, Aebi U. Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys J. 2004;86:3269–83.CrossRefPubMed
8.
go back to reference Jacot J, Dianis S, Schnall J, Wong J. A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues. J Biomed Mater Res. 2006;79A:485–94.CrossRef Jacot J, Dianis S, Schnall J, Wong J. A simple microindentation technique for mapping the microscale compliance of soft hydrated materials and tissues. J Biomed Mater Res. 2006;79A:485–94.CrossRef
9.
go back to reference Murayama Y, Constantinou C, Omata S. Micro-mechanical platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.CrossRefPubMed Murayama Y, Constantinou C, Omata S. Micro-mechanical platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.CrossRefPubMed
10.
go back to reference Murayama Y, Constantinou C, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005;120:543–9.CrossRef Murayama Y, Constantinou C, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005;120:543–9.CrossRef
11.
go back to reference Oie T, Murayama Y, Fukuda T, Nagai C, Omata S, Kanda K, Yaku H, Nakayama Y. Local elasticity imaging of vascular tissues by tactile mapping system. J Artif Organs. 2009;12:40–6.CrossRefPubMed Oie T, Murayama Y, Fukuda T, Nagai C, Omata S, Kanda K, Yaku H, Nakayama Y. Local elasticity imaging of vascular tissues by tactile mapping system. J Artif Organs. 2009;12:40–6.CrossRefPubMed
12.
go back to reference Oie T, Suzuki H, Fukuda T, Murayama Y, Omata S, Kanda K, Nakayama Y. Tactile mapping system: a novel imaging technology for surface topography and elasticity of tissues or organs. Innovations. 2009;4:345–50. Oie T, Suzuki H, Fukuda T, Murayama Y, Omata S, Kanda K, Nakayama Y. Tactile mapping system: a novel imaging technology for surface topography and elasticity of tissues or organs. Innovations. 2009;4:345–50.
13.
go back to reference Watanabe T, Kanda K, Ishibashi-Umeda H, Yaku H, Nakayama Y. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs. 2007;10:10–5.CrossRefPubMed Watanabe T, Kanda K, Ishibashi-Umeda H, Yaku H, Nakayama Y. Development of biotube vascular grafts incorporating cuffs for easy implantation. J Artif Organs. 2007;10:10–5.CrossRefPubMed
14.
go back to reference Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Autologous small-caliber “Biotube” vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits. J Biomed Mater Res B. 2010;92B:236–42.CrossRef Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Autologous small-caliber “Biotube” vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits. J Biomed Mater Res B. 2010;92B:236–42.CrossRef
15.
go back to reference Hayashida K, Kanda K, Yaku H, Ando J, Nakayama Y. Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): preparation of prototype model. J Thorac Cardiovasc Surg. 2007;134:152–9.CrossRefPubMed Hayashida K, Kanda K, Yaku H, Ando J, Nakayama Y. Development of an in vivo tissue-engineered autologous heart valve (the Biovalve): preparation of prototype model. J Thorac Cardiovasc Surg. 2007;134:152–9.CrossRefPubMed
16.
go back to reference Yamanami M, Yahata Y, Uechi M, Fujiwara M, Ishibashi-Ueda Hatsue, Kanda K, Watanabe T, Tajikawa T, Ohba K, Yaku H, Nakayama Y (2010) Development of a completely autologous valved-conduit with the sinus of valsalva (BIOVALVE) using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model. Circulation [Epub ahead of print] Yamanami M, Yahata Y, Uechi M, Fujiwara M, Ishibashi-Ueda Hatsue, Kanda K, Watanabe T, Tajikawa T, Ohba K, Yaku H, Nakayama Y (2010) Development of a completely autologous valved-conduit with the sinus of valsalva (BIOVALVE) using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model. Circulation [Epub ahead of print]
17.
go back to reference Yamanami M, Yahata Y, Tajikawa T, Ohba K, Watanabe T, Kanda K, Yaku H, Nakayama Y (2010) Preparation of in vivo tissue-engineered valved conduit with the sinus of valsalva (Type IV Biovalve). J Artif Organs (in press) Yamanami M, Yahata Y, Tajikawa T, Ohba K, Watanabe T, Kanda K, Yaku H, Nakayama Y (2010) Preparation of in vivo tissue-engineered valved conduit with the sinus of valsalva (Type IV Biovalve). J Artif Organs (in press)
Metadata
Title
Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope
Authors
Tomonori Oie
Hisato Suzuki
Yoshinobu Murayama
Toru Fukuda
Sadao Omata
Keiichi Kanda
Keiichi Takamizawa
Yasuhide Nakayama
Publication date
01-07-2010
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 2/2010
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-010-0503-2

Other articles of this Issue 2/2010

Journal of Artificial Organs 2/2010 Go to the issue