Skip to main content
Top
Published in: Pediatric Cardiology 6/2017

01-08-2017 | Original Article

Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization

3D image fusion for interventions in CHD

Authors: Sebastian Goreczny, Pawel Dryzek, Gareth J. Morgan, Maciej Lukaszewski, Jadwiga A. Moll, Tomasz Moszura

Published in: Pediatric Cardiology | Issue 6/2017

Login to get access

Abstract

We report initial experience with novel three-dimensional (3D) image fusion software for guidance of transcatheter interventions in congenital heart disease. Developments in fusion imaging have facilitated the integration of 3D roadmaps from computed tomography or magnetic resonance imaging datasets. The latest software allows live fusion of two-dimensional (2D) fluoroscopy with pre-registered 3D roadmaps. We reviewed all cardiac catheterizations guided with this software (Philips VesselNavigator). Pre-catheterization imaging and catheterization data were collected focusing on fusion of 3D roadmap, intervention guidance, contrast and radiation exposure. From 09/2015 until 06/2016, VesselNavigator was applied in 34 patients for guidance (n = 28) or planning (n = 6) of cardiac catheterization. In all 28 patients successful 2D–3D registration was performed. Bony structures combined with the cardiovascular silhouette were used for fusion in 26 patients (93%), calcifications in 9 (32%), previously implanted devices in 8 (29%) and low-volume contrast injection in 7 patients (25%). Accurate initial 3D roadmap alignment was achieved in 25 patients (89%). Six patients (22%) required realignment during the procedure due to distortion of the anatomy after introduction of stiff equipment. Overall, VesselNavigator was applied successfully in 27 patients (96%) without any complications related to 3D image overlay. VesselNavigator was useful in guidance of nearly all of cardiac catheterizations. The combination of anatomical markers and low-volume contrast injections allowed reliable 2D–3D registration in the vast majority of patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Glatz AC, Zhu X, Gillespie MJ, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. JACC Cardiovasc Imaging 3:1149–1157CrossRefPubMed Glatz AC, Zhu X, Gillespie MJ, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. JACC Cardiovasc Imaging 3:1149–1157CrossRefPubMed
2.
go back to reference Berman DP, Khan DM, Gutierrez Y, Zahn EM (2012) The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle. Catheter Cardiovasc Interv. 80:922–930CrossRefPubMed Berman DP, Khan DM, Gutierrez Y, Zahn EM (2012) The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle. Catheter Cardiovasc Interv. 80:922–930CrossRefPubMed
3.
go back to reference Glöckler M, Halbfaβ J, Koch A, Achenbach S, Dittrich S (2013) Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv. 82:436–442CrossRefPubMed Glöckler M, Halbfaβ J, Koch A, Achenbach S, Dittrich S (2013) Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv. 82:436–442CrossRefPubMed
4.
go back to reference Goreczny S, Morgan GJ, Dryzek P (2016) Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size. Cardiol Young 26:605–608CrossRefPubMed Goreczny S, Morgan GJ, Dryzek P (2016) Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size. Cardiol Young 26:605–608CrossRefPubMed
5.
go back to reference Peters M, Krings G, Koster M, Molenschot M, Freund MW, Breur JM (2015) Effective radiation dosage of three-dimensional rotational angiography in children. Europace 17:611–616CrossRefPubMed Peters M, Krings G, Koster M, Molenschot M, Freund MW, Breur JM (2015) Effective radiation dosage of three-dimensional rotational angiography in children. Europace 17:611–616CrossRefPubMed
6.
go back to reference Haddad L, Waller BR, Johnson J, Choudhri A, McGhee V, Zurakowski D, Kuhls-Gilcrist A, Sathanandam S (2016) Radiation protocol for three-dimensional rotational angiography to limit procedural radiation exposure in the Pediatric Cardiac Catheterization Lab. Congenit Heart Dis. doi:10.1111/chd.12356 PubMed Haddad L, Waller BR, Johnson J, Choudhri A, McGhee V, Zurakowski D, Kuhls-Gilcrist A, Sathanandam S (2016) Radiation protocol for three-dimensional rotational angiography to limit procedural radiation exposure in the Pediatric Cardiac Catheterization Lab. Congenit Heart Dis. doi:10.​1111/​chd.​12356 PubMed
7.
go back to reference Ratnayaka K, Raman VK, Faranesh AZ, Sonmez M, Kim JH, Gutiérrez LF, Ozturk C, McVeigh ER, Slack MC, Lederman RJ (2009) Antegrade percutaneous closure of membranous ventricular septal defect using X-ray fused with magnetic resonance imaging. JACC Cardiovasc Interv. 2:224–230CrossRefPubMedPubMedCentral Ratnayaka K, Raman VK, Faranesh AZ, Sonmez M, Kim JH, Gutiérrez LF, Ozturk C, McVeigh ER, Slack MC, Lederman RJ (2009) Antegrade percutaneous closure of membranous ventricular septal defect using X-ray fused with magnetic resonance imaging. JACC Cardiovasc Interv. 2:224–230CrossRefPubMedPubMedCentral
8.
go back to reference Tomkowiak MT, Klein AJ, Vigen KK, Hacker TA, Speidel MA, VanLysel MS, Raval AN (2011) Targeted transendocardial therapeutic delivery guided by MRI-x-ray image fusion. Catheter Cardiovasc Interv 78:468–478PubMed Tomkowiak MT, Klein AJ, Vigen KK, Hacker TA, Speidel MA, VanLysel MS, Raval AN (2011) Targeted transendocardial therapeutic delivery guided by MRI-x-ray image fusion. Catheter Cardiovasc Interv 78:468–478PubMed
9.
go back to reference Dori Y, Sarmiento M, Glatz AC, Gillespie MJ, Jones VM, Harris MA, Whitehead KK, Fogel MA, Rome JJ (2011) X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization. Circ Cardiovasc Imaging 4:415–424CrossRefPubMedPubMedCentral Dori Y, Sarmiento M, Glatz AC, Gillespie MJ, Jones VM, Harris MA, Whitehead KK, Fogel MA, Rome JJ (2011) X-ray magnetic resonance fusion to internal markers and utility in congenital heart disease catheterization. Circ Cardiovasc Imaging 4:415–424CrossRefPubMedPubMedCentral
10.
go back to reference Abu Hazeem AA, Dori Y, Whitehead KK, Harris MA, Fogel MA, Gillespie MJ, Rome JJ, Glatz AC (2014) X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease. Catheter Cardiovasc Interv 84:795–800CrossRefPubMed Abu Hazeem AA, Dori Y, Whitehead KK, Harris MA, Fogel MA, Gillespie MJ, Rome JJ, Glatz AC (2014) X-ray magnetic resonance fusion modality may reduce radiation exposure and contrast dose in diagnostic cardiac catheterization of congenital heart disease. Catheter Cardiovasc Interv 84:795–800CrossRefPubMed
11.
go back to reference Kliger C, Jelnin V, Sharma S, Panagopoulos G, Einhorn BN, Kumar R, Cuesta F, Maranan L, Kronzon I, Carelsen B, Cohen H, Perk G, Van Den Boomen R, Sahyoun C, Ruiz CE (2014) CT angiography-fluoroscopy fusion imaging for percutaneous transapical access. JACC Cardiovasc Imaging 7:169–177CrossRefPubMed Kliger C, Jelnin V, Sharma S, Panagopoulos G, Einhorn BN, Kumar R, Cuesta F, Maranan L, Kronzon I, Carelsen B, Cohen H, Perk G, Van Den Boomen R, Sahyoun C, Ruiz CE (2014) CT angiography-fluoroscopy fusion imaging for percutaneous transapical access. JACC Cardiovasc Imaging 7:169–177CrossRefPubMed
12.
go back to reference Tacher V, Lin M, Desgranges P, Deux JF, Grünhagen T, Becquemin JP, Luciani A, Rahmouni A, Kobeiter H (2013) Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion. J Vasc Interv Radiol 24:1698–1706CrossRefPubMedPubMedCentral Tacher V, Lin M, Desgranges P, Deux JF, Grünhagen T, Becquemin JP, Luciani A, Rahmouni A, Kobeiter H (2013) Image guidance for endovascular repair of complex aortic aneurysms: comparison of two-dimensional and three-dimensional angiography and image fusion. J Vasc Interv Radiol 24:1698–1706CrossRefPubMedPubMedCentral
13.
go back to reference Stangenberg L, Shuja F, Carelsen B, Elenbaas T, Wyers MC, Schermerhorn ML (2015) A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg 62:448–455CrossRefPubMed Stangenberg L, Shuja F, Carelsen B, Elenbaas T, Wyers MC, Schermerhorn ML (2015) A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg 62:448–455CrossRefPubMed
14.
go back to reference Fagan TE, Truong UT, Jone PN, Bracken J, Quaife R, Hazeem AA, Salcedo EE, Fonseca BM (2014) Multimodality 3 dimensional image integration for congenital cardiac catheterization. Methodist Debakey Cardiovasc J 10:68–76CrossRefPubMedPubMedCentral Fagan TE, Truong UT, Jone PN, Bracken J, Quaife R, Hazeem AA, Salcedo EE, Fonseca BM (2014) Multimodality 3 dimensional image integration for congenital cardiac catheterization. Methodist Debakey Cardiovasc J 10:68–76CrossRefPubMedPubMedCentral
15.
go back to reference Goreczny S, Dryzek P, Moszura T (2016) Use of pre-intervention imaging with a novel image fusion software for guidance of cardiac catheterisation in a patient with pulmonary atresia and major aortopulmonary collaterals. Cardiol Young. doi:10.1017/S1047951116000895 Goreczny S, Dryzek P, Moszura T (2016) Use of pre-intervention imaging with a novel image fusion software for guidance of cardiac catheterisation in a patient with pulmonary atresia and major aortopulmonary collaterals. Cardiol Young. doi:10.​1017/​S104795111600089​5
17.
go back to reference Faranesh AZ, Kellman P, Ratnayaka K, Lederman RJ (2013) Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray. Med Phys 40:032302CrossRefPubMedPubMedCentral Faranesh AZ, Kellman P, Ratnayaka K, Lederman RJ (2013) Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray. Med Phys 40:032302CrossRefPubMedPubMedCentral
18.
go back to reference Goreczny S, Moszura T, Dryzek P, Lukaszewski M, Krawczuk A, Moll J, Morgan GJ (2017) Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 25:91–99CrossRefPubMed Goreczny S, Moszura T, Dryzek P, Lukaszewski M, Krawczuk A, Moll J, Morgan GJ (2017) Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 25:91–99CrossRefPubMed
Metadata
Title
Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization
3D image fusion for interventions in CHD
Authors
Sebastian Goreczny
Pawel Dryzek
Gareth J. Morgan
Maciej Lukaszewski
Jadwiga A. Moll
Tomasz Moszura
Publication date
01-08-2017
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 6/2017
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-017-1627-4

Other articles of this Issue 6/2017

Pediatric Cardiology 6/2017 Go to the issue