Novel temporary left ventricular assist system with hydrodynamically levitated bearing pump for bridge to decision: initial preclinical assessment in a goat model

Authors: Satoru Kishimoto, Yoshiaki Takewa, Tomonori Tsukiya, Toshihide Mizuno, Kazuma Date, Hirohito Sumikura, Yutaka Fujii, Kentaro Ohnuma, Konomi Togo, Nobumasa Katagiri, Noritsugu Naito, Yuichiro Kishimoto, Yoshinobu Nakamura, Motonobu Nishimura, Eisuke Tatsumi

Published in: Journal of Artificial Organs | Issue 1/2018

Login to get access

Abstract

The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58–68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000–4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.
Literature
1.
go back to reference Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345:1435–43.CrossRefPubMed Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 2001;345:1435–43.CrossRefPubMed
2.
go back to reference Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRefPubMed Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;361:2241–51.CrossRefPubMed
3.
go back to reference Slaughter MS, Singh R. The role of ventricular assist devices in advanced heart failure. Rev Esp Cardiol. 2012;65:982–5.CrossRefPubMed Slaughter MS, Singh R. The role of ventricular assist devices in advanced heart failure. Rev Esp Cardiol. 2012;65:982–5.CrossRefPubMed
4.
go back to reference Puehler T, Ensminger S, Schoenbrodt M, Börgermann J, Rehn E, Hakim-Meibodi K, et al. Mechanical circulatory support devices as destination therapy-current evidence. Ann Cardiothorac Surg. 2014;3:513–24.PubMedPubMedCentral Puehler T, Ensminger S, Schoenbrodt M, Börgermann J, Rehn E, Hakim-Meibodi K, et al. Mechanical circulatory support devices as destination therapy-current evidence. Ann Cardiothorac Surg. 2014;3:513–24.PubMedPubMedCentral
5.
go back to reference Boyle AJ, Ascheim DD, Russo MJ, Kormos RL, John R, Naka Y, et al. Clinical outcomes for continuous-flow left ventricular assist device patients stratified by pre-operative INTERMACS classification. J Heart Lung Transpl. 2011;30:402–7.CrossRef Boyle AJ, Ascheim DD, Russo MJ, Kormos RL, John R, Naka Y, et al. Clinical outcomes for continuous-flow left ventricular assist device patients stratified by pre-operative INTERMACS classification. J Heart Lung Transpl. 2011;30:402–7.CrossRef
6.
go back to reference Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.CrossRefPubMed Ziemba EA, John R. Mechanical circulatory support for bridge to decision: which device and when to decide. J Card Surg. 2010;25:425–33.CrossRefPubMed
7.
go back to reference De Robertis F, Rogers P, Amrani M, Petrou M, Pepper JR, Bahrami T, et al. Bridge to decision using the Levitronix CentriMag short-term ventricular assist device. J Heart Lung Transpl. 2008;27:474–8.CrossRef De Robertis F, Rogers P, Amrani M, Petrou M, Pepper JR, Bahrami T, et al. Bridge to decision using the Levitronix CentriMag short-term ventricular assist device. J Heart Lung Transpl. 2008;27:474–8.CrossRef
8.
go back to reference Takayama H, Soni L, Kalesan B, Truby LK, Ota T, Cedola S, et al. Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes. Circ Heart Fail. 2014;7:799–806.CrossRefPubMedPubMedCentral Takayama H, Soni L, Kalesan B, Truby LK, Ota T, Cedola S, et al. Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes. Circ Heart Fail. 2014;7:799–806.CrossRefPubMedPubMedCentral
9.
go back to reference Borisenko O, Wylie G, Payne J, Bjessmo S, Smith J, Firmin R, et al. The cost impact of short-term ventricular assist devices and extracorporeal life support systems therapies on the National Health Service in the UK. Interact Cardiovasc Thorac Surg. 2014;19:41–8.CrossRefPubMed Borisenko O, Wylie G, Payne J, Bjessmo S, Smith J, Firmin R, et al. The cost impact of short-term ventricular assist devices and extracorporeal life support systems therapies on the National Health Service in the UK. Interact Cardiovasc Thorac Surg. 2014;19:41–8.CrossRefPubMed
10.
go back to reference Kashiwa K, Nishimura T, Saito A, Kubo H, Fukaya A, Tamai H, et al. Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult. J Artif Organs. 2012;15:207–10.CrossRefPubMed Kashiwa K, Nishimura T, Saito A, Kubo H, Fukaya A, Tamai H, et al. Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult. J Artif Organs. 2012;15:207–10.CrossRefPubMed
11.
go back to reference Khaliel F, Al Habeeb W, Saad E, Kjellman U. Use of Rotaflow pump for left ventricular assist device bridging for 15 weeks. Asian Cardiovasc Thorac Ann. 2014;22:205–7.CrossRefPubMed Khaliel F, Al Habeeb W, Saad E, Kjellman U. Use of Rotaflow pump for left ventricular assist device bridging for 15 weeks. Asian Cardiovasc Thorac Ann. 2014;22:205–7.CrossRefPubMed
12.
go back to reference Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs. 2006;30:324–38.CrossRefPubMed Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs. 2006;30:324–38.CrossRefPubMed
13.
go back to reference Sawa Y. Current status of third-generation implantable left ventricular assist devices in Japan, Duraheart and HeartWare. Surg Today. 2015;45:672–81.CrossRefPubMed Sawa Y. Current status of third-generation implantable left ventricular assist devices in Japan, Duraheart and HeartWare. Surg Today. 2015;45:672–81.CrossRefPubMed
14.
go back to reference Tanaka H, Tsukiya T, Tatsumi E, Mizuno T, Hidaka T, Okubo T, et al. Initial in vivo evaluation of the newly developed axial flow turbo pump with hydrodynamic bearings. J Artif Organs. 2011;14:31–8.CrossRefPubMed Tanaka H, Tsukiya T, Tatsumi E, Mizuno T, Hidaka T, Okubo T, et al. Initial in vivo evaluation of the newly developed axial flow turbo pump with hydrodynamic bearings. J Artif Organs. 2011;14:31–8.CrossRefPubMed
15.
go back to reference Tsukiya T, Mizuno T, Takewa Y, Tatsumi E, Taenaka Y. Preclinical study of a novel hydrodynamically levitated centrifugal pump for long-term cardiopulmonary support: in vivo performance during percutaneous cardiopulmonary support. J Artif Organs. 2015;18:300–6.CrossRefPubMed Tsukiya T, Mizuno T, Takewa Y, Tatsumi E, Taenaka Y. Preclinical study of a novel hydrodynamically levitated centrifugal pump for long-term cardiopulmonary support: in vivo performance during percutaneous cardiopulmonary support. J Artif Organs. 2015;18:300–6.CrossRefPubMed
16.
go back to reference Nishimura T. Current status of extracorporeal ventricular assist devices in Japan. J Artif Organs. 2014;17:211–9.CrossRefPubMed Nishimura T. Current status of extracorporeal ventricular assist devices in Japan. J Artif Organs. 2014;17:211–9.CrossRefPubMed
17.
go back to reference Mohite PN, Zych B, Popov AF, Sabashnikov A, Sáez DG, Patil NP, et al. CentriMag short-term ventricular assist as a bridge to solution in patients with advanced heart failure: use beyond 30 days. Eur J Cardiothorac Surg. 2013;44:e310–e5.CrossRefPubMed Mohite PN, Zych B, Popov AF, Sabashnikov A, Sáez DG, Patil NP, et al. CentriMag short-term ventricular assist as a bridge to solution in patients with advanced heart failure: use beyond 30 days. Eur J Cardiothorac Surg. 2013;44:e310–e5.CrossRefPubMed
18.
go back to reference Takeda S, Kotani T, Nakagawa S, Ichiba S, Aokage T, Ochiai R, et al. Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) severe respiratory failure in Japan. J Anesth. 2012;26:650–7.CrossRefPubMedPubMedCentral Takeda S, Kotani T, Nakagawa S, Ichiba S, Aokage T, Ochiai R, et al. Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) severe respiratory failure in Japan. J Anesth. 2012;26:650–7.CrossRefPubMedPubMedCentral
19.
go back to reference Takauji S, Saito T, Sato T, Okada M, Kano H, Makise H, et al. A comparison between long- and short-term extracorporeal membrane oxygenation. [Long-term ECMO 症例と short-term ECMO 症例の比較検討]. Jpn J Respir Care. 2014;31:45–9 (Japanese). Takauji S, Saito T, Sato T, Okada M, Kano H, Makise H, et al. A comparison between long- and short-term extracorporeal membrane oxygenation. [Long-term ECMO 症例と short-term ECMO 症例の比較検討]. Jpn J Respir Care. 2014;31:45–9 (Japanese).
20.
go back to reference Date K, Kishimoto S, Fujii Y, Togo K, Kakuta Y, Mizuno T, et al. Effects of feeding state on anticoagulation in adult goats treated with warfarin. J Artif Organs 2016;19301–4. Date K, Kishimoto S, Fujii Y, Togo K, Kakuta Y, Mizuno T, et al. Effects of feeding state on anticoagulation in adult goats treated with warfarin. J Artif Organs 2016;19301–4.
Metadata
Title
Novel temporary left ventricular assist system with hydrodynamically levitated bearing pump for bridge to decision: initial preclinical assessment in a goat model
Authors
Satoru Kishimoto
Yoshiaki Takewa
Tomonori Tsukiya
Toshihide Mizuno
Kazuma Date
Hirohito Sumikura
Yutaka Fujii
Kentaro Ohnuma
Konomi Togo
Nobumasa Katagiri
Noritsugu Naito
Yuichiro Kishimoto
Yoshinobu Nakamura
Motonobu Nishimura
Eisuke Tatsumi
Publication date
01-03-2018
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2018
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-017-0989-y

Other articles of this Issue 1/2018

Journal of Artificial Organs 1/2018 Go to the issue