Skip to main content
Top
Published in: European Radiology 10/2013

01-10-2013 | Interventional

MRI-guided percutaneous coaxial cutting needle biopsy of small pulmonary nodules: feasibility

Authors: Ming Liu, Yubo Lv, Lebin Wu, Jiqing Song, Roberto Blanco Sequeiros, Chengli Li

Published in: European Radiology | Issue 10/2013

Login to get access

Abstract

Objectives

To prospectively evaluate the feasibility, safety and accuracy of magnetic resonance imaging (MRI)-guided percutaneous coaxial cutting needle biopsy of small (≤2.0 cm in diameter) pulmonary nodules.

Methods

Ninety-six patients (56 men and 40 women) with 96 small lung nodules underwent MRI-guided percutaneous coaxial cutting needle biopsy. These lesions were divided into two groups according to maximum nodule diameters: 0.5–1.0 cm (n = 25) and 1.1–2.0 cm (n = 71). The diagnostic accuracy, sensitivity and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test.

Results

All specimens obtained were sufficient for diagnosis. Histological examination of needle biopsy revealed 64 malignant, 30 benign and 2 indeterminate nodules. The final diagnoses from surgery or clinical follow-up were 67 malignant nodules and 29 benign nodules. The diagnostic performance of MRI-guided percutaneous coaxial cutting needle biopsy in diagnosing malignant tumours was as follows: accuracy, 97 %; sensitivity, 96 %; specificity, 100 %; positive predictive value, 100 %; and negative predictive value, 91 %. There was no significant difference between the two groups (P > 0.05, Fisher's exact test). No serious complications occurred.

Conclusions

MRI-guided percutaneous coaxial cutting needle biopsy is a safe and accurate diagnostic technique in the evaluation of small lung nodules.

Key Points

MRI-guided biopsy helps clinicians to assess patients with small lung nodules.
Differentiation of malignant and benign nodules is possible with 97 % accuracy.
MRI guidance enables accurate lung biopsy without ionising radiation.
No serious complications occurred in MRI-guided lung biopsy.
Literature
1.
2.
go back to reference Wisnivesky JP, Henschke CI, Yankelevitz DF (2006) Diagnostic percutaneous transthoracic needle biopsy does not affect survival in stage I lung cancer. Am J Respir Crit Care Med 174:684–688PubMedCrossRef Wisnivesky JP, Henschke CI, Yankelevitz DF (2006) Diagnostic percutaneous transthoracic needle biopsy does not affect survival in stage I lung cancer. Am J Respir Crit Care Med 174:684–688PubMedCrossRef
3.
go back to reference Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 137:31–35PubMed Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 137:31–35PubMed
4.
go back to reference Aviram G, Schwartz DS, Meirsdorf S, Rosen G, Greif J, Graif M (2005) Transthoracic needle biopsy of lung masses: a survey of techniques. Clin Radiol 60:370–374PubMedCrossRef Aviram G, Schwartz DS, Meirsdorf S, Rosen G, Greif J, Graif M (2005) Transthoracic needle biopsy of lung masses: a survey of techniques. Clin Radiol 60:370–374PubMedCrossRef
5.
go back to reference Laurent F, Latrabe V, Vergier B, Michel P (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef Laurent F, Latrabe V, Vergier B, Michel P (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef
6.
go back to reference Heck SL, Blom P, Berstad A (2006) Accuracy and complications in computed tomography fluoroscopy–guided needle biopsies of lung masses. Eur Radiol 16:1387–1392PubMedCrossRef Heck SL, Blom P, Berstad A (2006) Accuracy and complications in computed tomography fluoroscopy–guided needle biopsies of lung masses. Eur Radiol 16:1387–1392PubMedCrossRef
7.
go back to reference Hwang HS, Chung MJ, Lee JW (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 195:400–407CrossRef Hwang HS, Chung MJ, Lee JW (2010) C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 195:400–407CrossRef
8.
go back to reference Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202:97–103PubMed Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202:97–103PubMed
9.
go back to reference Tomiyama N, Mihara N, Maeda M et al (2000) CT-guided needle biopsy of small pulmonary nodules: value of respiratory gating. Radiology 217:907–910PubMed Tomiyama N, Mihara N, Maeda M et al (2000) CT-guided needle biopsy of small pulmonary nodules: value of respiratory gating. Radiology 217:907–910PubMed
10.
go back to reference Wallace MJ, Krishnamurthy S, Broemeling LD et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions. Radiology 225:823–828PubMedCrossRef Wallace MJ, Krishnamurthy S, Broemeling LD et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions. Radiology 225:823–828PubMedCrossRef
11.
go back to reference Ohno Y, Hatabu H, Takenaka D et al (2003) CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 180:1665–1669PubMedCrossRef Ohno Y, Hatabu H, Takenaka D et al (2003) CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 180:1665–1669PubMedCrossRef
12.
go back to reference Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC (1996) Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 167:105–109PubMedCrossRef Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC (1996) Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 167:105–109PubMedCrossRef
13.
go back to reference Yamagami T, Iida S, Kato T, Tanaka O, Nishimura T (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules? AJR Am J Roentgenol 180:811–815PubMedCrossRef Yamagami T, Iida S, Kato T, Tanaka O, Nishimura T (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules? AJR Am J Roentgenol 180:811–815PubMedCrossRef
14.
go back to reference Silit E, Kizilkaya E, Okutan O et al (2003) CT fluoroscopy-guided percutaneous needle biopsies in thoracic mass lesions. Eur J Radiol 48:193–197PubMedCrossRef Silit E, Kizilkaya E, Okutan O et al (2003) CT fluoroscopy-guided percutaneous needle biopsies in thoracic mass lesions. Eur J Radiol 48:193–197PubMedCrossRef
15.
go back to reference Tsalafoutas IA, Tsapaki V, Triantopoulou C, Gorantonaki A, Papailiou J (2007) CT-guided interventional procedures without CT fluoroscopy assistance: patient effective dose and absorbed dose considerations. AJR Am J Roentgenol 188:1479–1484PubMedCrossRef Tsalafoutas IA, Tsapaki V, Triantopoulou C, Gorantonaki A, Papailiou J (2007) CT-guided interventional procedures without CT fluoroscopy assistance: patient effective dose and absorbed dose considerations. AJR Am J Roentgenol 188:1479–1484PubMedCrossRef
16.
go back to reference Buls N, Pages J, de Mey J, Osteaux M (2003) Evaluation of patient and staff doses during various CT fluoroscopy guided interventions. Health Phys 85:165–173PubMedCrossRef Buls N, Pages J, de Mey J, Osteaux M (2003) Evaluation of patient and staff doses during various CT fluoroscopy guided interventions. Health Phys 85:165–173PubMedCrossRef
17.
go back to reference Nawfel RD, Judy PF, Silverman SG, Hooton S, Tuncali K, Adams DF (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184PubMed Nawfel RD, Judy PF, Silverman SG, Hooton S, Tuncali K, Adams DF (2000) Patient and personnel exposure during CT fluoroscopy-guided interventional procedures. Radiology 216:180–184PubMed
18.
go back to reference Stattaus J, Maderwald S, Baba HA et al (2008) MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system. Eur Radiol 18:2865–2873PubMedCrossRef Stattaus J, Maderwald S, Baba HA et al (2008) MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system. Eur Radiol 18:2865–2873PubMedCrossRef
19.
go back to reference Obenauer S, Grabbe E, Knollmann F (2006) Value of MR-guided localization and biopsy in breast lesions. Rofo 178:477–483PubMedCrossRef Obenauer S, Grabbe E, Knollmann F (2006) Value of MR-guided localization and biopsy in breast lesions. Rofo 178:477–483PubMedCrossRef
20.
go back to reference Fritz J, Tzaribachev N, Thomas C et al (2012) Magnetic resonance imaging-guided osseous biopsy in children with chronic recurrent multifocal osteomyelitis. Cardiovasc Intervent Radiol 35:146–153PubMedCrossRef Fritz J, Tzaribachev N, Thomas C et al (2012) Magnetic resonance imaging-guided osseous biopsy in children with chronic recurrent multifocal osteomyelitis. Cardiovasc Intervent Radiol 35:146–153PubMedCrossRef
21.
go back to reference Merkle EM, Lewin JS, Aschoff AJ et al (2000) Percutaneous magnetic resonance image-guided biopsy and aspiration in the head and neck. Laryngoscope 110:382–385PubMedCrossRef Merkle EM, Lewin JS, Aschoff AJ et al (2000) Percutaneous magnetic resonance image-guided biopsy and aspiration in the head and neck. Laryngoscope 110:382–385PubMedCrossRef
22.
go back to reference Kuhn JP, Langner S, Hegenscheid K et al (2010) Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: Feasibility, handling, and needle artifacts. Eur Radiol 20:2414–2421PubMedCrossRef Kuhn JP, Langner S, Hegenscheid K et al (2010) Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: Feasibility, handling, and needle artifacts. Eur Radiol 20:2414–2421PubMedCrossRef
23.
go back to reference Yakar D, Hambrock T, Huisman H et al (2010) Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy. Invest Radiol 45:121–125PubMedCrossRef Yakar D, Hambrock T, Huisman H et al (2010) Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy. Invest Radiol 45:121–125PubMedCrossRef
24.
go back to reference Kariniemi J, Blanco Sequeiros R, Ojala R, Tervonen O (2005) MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. Eur Radiol 15:1256–1262PubMedCrossRef Kariniemi J, Blanco Sequeiros R, Ojala R, Tervonen O (2005) MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. Eur Radiol 15:1256–1262PubMedCrossRef
25.
go back to reference Sakarya ME, Ynak O, Ozbay B et al (2003) MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility. Radiology 228:589–592PubMedCrossRef Sakarya ME, Ynak O, Ozbay B et al (2003) MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility. Radiology 228:589–592PubMedCrossRef
26.
go back to reference Ojala R, Vahala E, Karppinen J et al (2001) Nerve root infiltration of the first sacral root with MRI guidance. J Magn Reson Imaging 12:556–561CrossRef Ojala R, Vahala E, Karppinen J et al (2001) Nerve root infiltration of the first sacral root with MRI guidance. J Magn Reson Imaging 12:556–561CrossRef
27.
go back to reference Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed Moore EH (1998) Technical aspects of needle aspiration lung biopsy: a personal perspective. Radiology 208:303–318PubMed
28.
go back to reference Yamagami T, Kato T, Iida S, Hirota T, Nishimura T (2004) Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt. Chest 126:744–747PubMedCrossRef Yamagami T, Kato T, Iida S, Hirota T, Nishimura T (2004) Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt. Chest 126:744–747PubMedCrossRef
29.
go back to reference Kazerooni EA, Hartker FW, Whyte RI, Martinez FJ, Lynch JP (1996) Transthoracic needle aspiration in patients with severe emphysema: a study of lung transplant candidates. Chest 109:616–619PubMedCrossRef Kazerooni EA, Hartker FW, Whyte RI, Martinez FJ, Lynch JP (1996) Transthoracic needle aspiration in patients with severe emphysema: a study of lung transplant candidates. Chest 109:616–619PubMedCrossRef
30.
go back to reference Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed
31.
go back to reference Harter LP, Moss AA, Goldberg HI, Gross BH (1983) CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol 140:363–367PubMedCrossRef Harter LP, Moss AA, Goldberg HI, Gross BH (1983) CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol 140:363–367PubMedCrossRef
32.
go back to reference Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMedCrossRef Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMedCrossRef
33.
go back to reference Laurent F, Michel P, Latrabe V et al (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique. AJR Am J Roentgenol 172:1049–1053PubMedCrossRef Laurent F, Michel P, Latrabe V et al (1999) Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique. AJR Am J Roentgenol 172:1049–1053PubMedCrossRef
Metadata
Title
MRI-guided percutaneous coaxial cutting needle biopsy of small pulmonary nodules: feasibility
Authors
Ming Liu
Yubo Lv
Lebin Wu
Jiqing Song
Roberto Blanco Sequeiros
Chengli Li
Publication date
01-10-2013
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 10/2013
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-013-2871-5

Other articles of this Issue 10/2013

European Radiology 10/2013 Go to the issue