Skip to main content
Top
Published in: European Radiology 12/2008

01-12-2008 | Interventional

MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system

Authors: Joerg Stattaus, Stefan Maderwald, Hideo A. Baba, Guido Gerken, Joerg Barkhausen, Michael Forsting, Mark E. Ladd

Published in: European Radiology | Issue 12/2008

Login to get access

Abstract

The purpose of this study was to evaluate the diagnostic efficacy of magnetic resonance (MR)-guided biopsy of focal liver lesions within a short, wide-bore 1.5-T MR system and to determine the duration and accuracy of needle placement using MR fluoroscopy guidance in 25 patients. Accuracy of needle placement was evaluated in two orthogonal planes, and the out-of-plane angle of needle deflection was measured. Needle positioning was characterised subjectively as centred, peripheral, or exterior relative to the lesion. Exterior positioning was corrected by a step-by-step procedure. Surgical resection (n = 6), previous histologies (n = 8), or clinical/radiological follow-up (n = 11) served as the ‘gold standard’. The guidance needle could be placed successfully using MR fluoroscopy in 20 of 25 patients (80%). Needle placement was rated as ‘centred’ in 11 and as ‘peripheral’ in nine patients. Median needle deflection was 2.6 degrees, with a median deviation of 3.4 mm. In five patients, the direct approach failed or was rated as ‘exterior’; therefore, repositioning after needle stabilisation with a stainless-steel stylet was necessary. The diagnostic yield of all biopsies was: sensitivity 95.5%, specificity 100.0% and accuracy 96.0%. In conclusion, MR-guided biopsies in a short, wide-bore MR system yielded highly reliable biopsy results, and in most cases the direct approach with MR fluoroscopy guidance proved to be fast and accurate.
Literature
1.
go back to reference Rappeport ED, Loft A (2007) Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography. Abdom Imaging 32:624–634PubMedCrossRef Rappeport ED, Loft A (2007) Liver metastases from colorectal cancer: imaging with superparamagnetic iron oxide (SPIO)-enhanced MR imaging, computed tomography and positron emission tomography. Abdom Imaging 32:624–634PubMedCrossRef
2.
go back to reference Winterer JT, Kotter E, Ghanem N, Langer M (2006) Detection and characterization of benign focal liver lesions with multislice CT. Eur Radiol 16:2427–2443PubMedCrossRef Winterer JT, Kotter E, Ghanem N, Langer M (2006) Detection and characterization of benign focal liver lesions with multislice CT. Eur Radiol 16:2427–2443PubMedCrossRef
3.
go back to reference Chojniak R, Isberner RK, Viana LM, Yu LS, Aita AA, Soares FA (2006) Computed tomography guided needle biopsy: experience from 1,300 procedures. Sao Paulo Med J 124:10–14PubMedCrossRef Chojniak R, Isberner RK, Viana LM, Yu LS, Aita AA, Soares FA (2006) Computed tomography guided needle biopsy: experience from 1,300 procedures. Sao Paulo Med J 124:10–14PubMedCrossRef
4.
go back to reference Welch TJ, Sheedy PF 2nd, Johnson CD, Johnson CM, Stephens DH (1989) CT-guided biopsy: prospective analysis of 1,000 procedures. Radiology 171:493–496PubMed Welch TJ, Sheedy PF 2nd, Johnson CD, Johnson CM, Stephens DH (1989) CT-guided biopsy: prospective analysis of 1,000 procedures. Radiology 171:493–496PubMed
5.
go back to reference Adam G, Bucker A, Nolte-Ernsting C, Tacke J, Gunther RW (1999) Interventional MR imaging: percutaneous abdominal and skeletal biopsies and drainages of the abdomen. Eur Radiol 9:1471–1478PubMedCrossRef Adam G, Bucker A, Nolte-Ernsting C, Tacke J, Gunther RW (1999) Interventional MR imaging: percutaneous abdominal and skeletal biopsies and drainages of the abdomen. Eur Radiol 9:1471–1478PubMedCrossRef
6.
go back to reference Schmidt AJ, Kee ST, Sze DY, Daniel BL, Razavi MK, Semba CP, Dake MD (1999) Diagnostic yield of MR-guided liver biopsies compared with CT- and US-guided liver biopsies. J Vasc Interv Radiol 10:1323–1329PubMedCrossRef Schmidt AJ, Kee ST, Sze DY, Daniel BL, Razavi MK, Semba CP, Dake MD (1999) Diagnostic yield of MR-guided liver biopsies compared with CT- and US-guided liver biopsies. J Vasc Interv Radiol 10:1323–1329PubMedCrossRef
7.
go back to reference Stattaus J, Kuehl H, Ladd S, Schroeder T, Antoch G, Baba HA, Barkhausen J, Forsting M (2007) CT-guided biopsy of small liver lesions: visibility, artifacts, and corresponding diagnostic accuracy. Cardiovasc Intervent Radiol 30:928–935PubMedCrossRef Stattaus J, Kuehl H, Ladd S, Schroeder T, Antoch G, Baba HA, Barkhausen J, Forsting M (2007) CT-guided biopsy of small liver lesions: visibility, artifacts, and corresponding diagnostic accuracy. Cardiovasc Intervent Radiol 30:928–935PubMedCrossRef
8.
go back to reference Rofsky NM, Yang BM, Schlossberg P, Goldenberg A, Teperman LW, Weinreb JC (1998) MR-guided needle aspiration biopsies of hepatic masses using a closed bore magnet. J Comput Assist Tomogr 22:633–637PubMedCrossRef Rofsky NM, Yang BM, Schlossberg P, Goldenberg A, Teperman LW, Weinreb JC (1998) MR-guided needle aspiration biopsies of hepatic masses using a closed bore magnet. J Comput Assist Tomogr 22:633–637PubMedCrossRef
9.
go back to reference Silverman SG, Collick BD, Figueira MR, Khorasani R, Adams DF, Newman RW, Topulos GP, Jolesz FA (1995) Interactive MR-guided biopsy in an open-configuration MR imaging system. Radiology 197:175–181PubMed Silverman SG, Collick BD, Figueira MR, Khorasani R, Adams DF, Newman RW, Topulos GP, Jolesz FA (1995) Interactive MR-guided biopsy in an open-configuration MR imaging system. Radiology 197:175–181PubMed
10.
go back to reference Lu DS, Lee H, Farahani K, Sinha S, Lufkin R (1997) Biopsy of hepatic dome lesions: semi-real-time coronal MR guidance technique. AJR Am J Roentgenol 168:737–739PubMed Lu DS, Lee H, Farahani K, Sinha S, Lufkin R (1997) Biopsy of hepatic dome lesions: semi-real-time coronal MR guidance technique. AJR Am J Roentgenol 168:737–739PubMed
11.
go back to reference Zangos S, Kiefl D, Eichler K, Engelmann K, Heller M, Herzog C, Mack MG, Jacobi V, Vogl TJ (2003) [MR-guided biopsies of undetermined liver lesions: technique and results]. Rofo 175:688–694PubMed Zangos S, Kiefl D, Eichler K, Engelmann K, Heller M, Herzog C, Mack MG, Jacobi V, Vogl TJ (2003) [MR-guided biopsies of undetermined liver lesions: technique and results]. Rofo 175:688–694PubMed
12.
go back to reference Salomonowitz E (2001) MR imaging-guided biopsy and therapeutic intervention in a closed-configuration magnet: single-center series of 361 punctures. AJR Am J Roentgenol 177:159–163PubMed Salomonowitz E (2001) MR imaging-guided biopsy and therapeutic intervention in a closed-configuration magnet: single-center series of 361 punctures. AJR Am J Roentgenol 177:159–163PubMed
13.
go back to reference Kariniemi J, Blanco Sequeiros R, Ojala R, Tervonen O (2005) MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. Eur Radiol 15:1256–1262PubMedCrossRef Kariniemi J, Blanco Sequeiros R, Ojala R, Tervonen O (2005) MRI-guided abdominal biopsy in a 0.23-T open-configuration MRI system. Eur Radiol 15:1256–1262PubMedCrossRef
14.
go back to reference Arepally A, Karmarkar PV, Qian D, Barnett B, Atalar E (2006) Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model. J Vasc Interv Radiol 17:1165–1173PubMedCrossRef Arepally A, Karmarkar PV, Qian D, Barnett B, Atalar E (2006) Evaluation of MR/fluoroscopy-guided portosystemic shunt creation in a swine model. J Vasc Interv Radiol 17:1165–1173PubMedCrossRef
15.
go back to reference Stattaus J, Maderwald S, Forsting M, Barkhausen J, Ladd ME (2008) MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5-Tesla scanner: feasibility and initial results. J Magn Reson Imaging 27:1181–1187PubMedCrossRef Stattaus J, Maderwald S, Forsting M, Barkhausen J, Ladd ME (2008) MR-guided core biopsy with MR fluoroscopy using a short, wide-bore 1.5-Tesla scanner: feasibility and initial results. J Magn Reson Imaging 27:1181–1187PubMedCrossRef
16.
go back to reference Langen HJ, Kugel H, Landwehr P (2002) MR-guided core biopsies using a closed 1.0 T imager, First clinical results. Eur J Radiol 41:19–25PubMedCrossRef Langen HJ, Kugel H, Landwehr P (2002) MR-guided core biopsies using a closed 1.0 T imager, First clinical results. Eur J Radiol 41:19–25PubMedCrossRef
17.
go back to reference Ladd ME, Erhart P, Debatin JF, Romanowski BJ, Boesiger P, McKinnon GC (1996) Biopsy needle susceptibility artifacts. Magn Reson Med 36:646–651PubMedCrossRef Ladd ME, Erhart P, Debatin JF, Romanowski BJ, Boesiger P, McKinnon GC (1996) Biopsy needle susceptibility artifacts. Magn Reson Med 36:646–651PubMedCrossRef
18.
go back to reference Konig CW, Pereira PL, Trubenbach J, Fritz J, Duda SH, Schick F, Claussen CD (2003) MR imaging-guided adrenal biopsy using an open low-field-strength scanner and MR fluoroscopy. AJR Am J Roentgenol 180:1567–1570PubMed Konig CW, Pereira PL, Trubenbach J, Fritz J, Duda SH, Schick F, Claussen CD (2003) MR imaging-guided adrenal biopsy using an open low-field-strength scanner and MR fluoroscopy. AJR Am J Roentgenol 180:1567–1570PubMed
19.
go back to reference Sakarya ME, Unal O, Ozbay B, Uzun K, Kati I, Ozen S, Etlik O (2003) MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility. Radiology 228:589–592PubMedCrossRef Sakarya ME, Unal O, Ozbay B, Uzun K, Kati I, Ozen S, Etlik O (2003) MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: feasibility. Radiology 228:589–592PubMedCrossRef
20.
go back to reference Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF (1999) CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212:673–681PubMed Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF (1999) CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212:673–681PubMed
21.
go back to reference Zangos S, Eichler K, Wetter A, Lehnert T, Hammerstingl R, Diebold T, Reichel P, Herzog C, Hansmann ML, Mack MG, Vogl TJ (2006) MR-guided biopsies of lesions in the retroperitoneal space: technique and results. Eur Radiol 16:307–312PubMedCrossRef Zangos S, Eichler K, Wetter A, Lehnert T, Hammerstingl R, Diebold T, Reichel P, Herzog C, Hansmann ML, Mack MG, Vogl TJ (2006) MR-guided biopsies of lesions in the retroperitoneal space: technique and results. Eur Radiol 16:307–312PubMedCrossRef
22.
go back to reference Langen HJ, Stutzer H, Kugel H, Krug B, Hesselmann V, Schulte O, Walter C, Landwehr P (2000) [Precision of MRI-guided needle placement-experimental results]. Rofo 172:922–926PubMed Langen HJ, Stutzer H, Kugel H, Krug B, Hesselmann V, Schulte O, Walter C, Landwehr P (2000) [Precision of MRI-guided needle placement-experimental results]. Rofo 172:922–926PubMed
Metadata
Title
MR-guided liver biopsy within a short, wide-bore 1.5 Tesla MR system
Authors
Joerg Stattaus
Stefan Maderwald
Hideo A. Baba
Guido Gerken
Joerg Barkhausen
Michael Forsting
Mark E. Ladd
Publication date
01-12-2008
Publisher
Springer-Verlag
Published in
European Radiology / Issue 12/2008
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1088-5

Other articles of this Issue 12/2008

European Radiology 12/2008 Go to the issue