Abstract

To include the two key parameters of circulating air volume and instantaneous ultraviolet illuminance, as well as the minor influencing factors such as temperature, humidity, comings and goings of personnel and other parameters into the scope of conventional monitoring, and monitor and alarm each parameter, the key problem is to design the data transmission of sensors of existing products and debug the network management system, and solve every problem in the research process through the cycle of experiment-trial-experiment. The specific functions of a single instrument and system software can be achieved by solving the key links such as type selection of various sensors, circuit interface, guarantee measures for measurement accuracy of various parameters, research and development of networked air disinfection management system software, design of WiFi interface, cost control of single machine and system and so on. And ultraviolet luminance sensors can be used to monitor the ultraviolet intensity in the machine in real time, and monitor 7 parameters, including circulating air volume, ozone concentration, comings and goings of personnel, temperature, humidity and leaked ultraviolet intensity.
Literature
1.
go back to reference Roth, A., Douglass, K., and Wagner, J., “Effectiveness of a shielded ultraviolet C air disinfection system in an inpatient pharmacy of a tertiary care children's hospital” lacks scientific evidence. Am. J. Infect. Control 46(6):730–731, 2018.CrossRef Roth, A., Douglass, K., and Wagner, J., “Effectiveness of a shielded ultraviolet C air disinfection system in an inpatient pharmacy of a tertiary care children's hospital” lacks scientific evidence. Am. J. Infect. Control 46(6):730–731, 2018.CrossRef
2.
go back to reference Quintero, D. G., Taylor, R. B., and Miller, M. B., Air-abrasive disinfection of implant surfaces in a simulated model of Periimplantitis. Implant. Dent. 26(3):423, 2017.CrossRef Quintero, D. G., Taylor, R. B., and Miller, M. B., Air-abrasive disinfection of implant surfaces in a simulated model of Periimplantitis. Implant. Dent. 26(3):423, 2017.CrossRef
3.
go back to reference Balikhin, I. L., Berestenko, V. I., and Domashnev, I. A., Photocatalytic recyclers for purification and disinfection of indoor air in medical institutions. Biomed. Eng. 49(6):389–393, 2016.CrossRef Balikhin, I. L., Berestenko, V. I., and Domashnev, I. A., Photocatalytic recyclers for purification and disinfection of indoor air in medical institutions. Biomed. Eng. 49(6):389–393, 2016.CrossRef
4.
go back to reference Versiani, M. A., Ordinola-Zapata, R., and Keleş, A., Middle mesial canals in mandibular first molars: A micro-CT study in different populations. Arch. Oral Biol. 61:130–137, 2016.CrossRef Versiani, M. A., Ordinola-Zapata, R., and Keleş, A., Middle mesial canals in mandibular first molars: A micro-CT study in different populations. Arch. Oral Biol. 61:130–137, 2016.CrossRef
5.
go back to reference Li, Q., Xie, R., and Li, Y. W., Enhanced visible-light-induced photocatalytic disinfection of E. Coli by carbon-sensitized nitrogen-doped titanium oxide. Environ. Sci. Technol. 41(14):5050–5056, 2016.CrossRef Li, Q., Xie, R., and Li, Y. W., Enhanced visible-light-induced photocatalytic disinfection of E. Coli by carbon-sensitized nitrogen-doped titanium oxide. Environ. Sci. Technol. 41(14):5050–5056, 2016.CrossRef
6.
go back to reference Tardif, R., Catto, C., and Haddad, S., Assessment of air and water contamination by disinfection by-products at 41 indoor swimming pools. Environ. Res. 148:411–420, 2016.CrossRef Tardif, R., Catto, C., and Haddad, S., Assessment of air and water contamination by disinfection by-products at 41 indoor swimming pools. Environ. Res. 148:411–420, 2016.CrossRef
7.
go back to reference Benammar, M., Abdaoui, A., and Shm, A., A modular IoT platform for real-time indoor air quality monitoring. Sensors 18(2):581, 2018.CrossRef Benammar, M., Abdaoui, A., and Shm, A., A modular IoT platform for real-time indoor air quality monitoring. Sensors 18(2):581, 2018.CrossRef
Metadata
Title
Monitoring and Control of Medical Air Disinfection Parameters of Nosocomial Infection System Based on Internet of Things
Authors
Liu Yang
Tianling Yao
Guiting Liu
Limei Sun
Na Yang
He Zhang
Shuli Zhang
Yueguang Yang
Yaqiu Pang
Xiaohong Liu
Xianming Hou
Publication date
01-05-2019
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2019
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-019-1205-9

Other articles of this Issue 5/2019

Journal of Medical Systems 5/2019 Go to the issue