Published in: Journal of Medical Systems 5/2019

01-05-2019 | Education & Training

Monitoring an Analysis of Perturbations in Fusion Deposition Modelling (FDM) Processes for the Use of Biomaterials

Authors: Fernando Blaya Haro, José María de Agustín del Burgo, Roberto D’Amato, Manuel Islán, Enrique Soriano Heras, Jesus Manuel Garcia Alonso, Juan Antonio Juanes Mendez

Published in: Journal of Medical Systems | Issue 5/2019

Login to get access

Abstract

During an FDM production process, there are different external disturbances to the characteristics of the machine that can affect to the production process. These disturbances will cause the final result differs from the desired one. Moreover, these disturbances, such as temperature or chamber humidity, are extremely important in case of using biocompatible materials. The use of these kind of materials with not controlled environment, can cause them to modify or loss of their properties; what will make the product unusable. Apart from these external disturbances, the conditions of the machine to which the material is subjected must also be considered, such as temperature, vibrations or extrusion speed. The monitoring of all these data will allow to know the conditions to which the product was exposed during the process. In this way, it will be able to verify the validity of the final product. For these reasons, the purpose of this work is to monitor the conditions of production of structures with biocompatible materials by fused deposition modelling (FDM) technique. This monitoring will allow us to obtain a report that guarantee the technical and geometrical characteristics of the model and the biomaterial properties. The parameters chosen to be monitored are: Diameter of filament use, temperature in extrusion nozzle, ambient temperature in closed chamber, ambient humidity in closed chamber. The obtained results, after collected and analysing the data, present variations of up to 3% in the temperature of the nozzle of the extruder with respect to set temperature. In the case of the filament diameter the difference with respect to the value provided from the filament supplier is of 13,7%. In addition, the results show how the ambient humidity in closed chamber has changed by 2 percentage points and the ambient temperature in closed chamber has been increased 6,52 °C with respect to the set values.
Literature
1.
go back to reference Wojciechowski, S., Maruda, R. W., Barrans, S., Nieslony, P., and Krolczyk, G. M., Optimisation of machining parameters during ball end milling of hardened steel with various surface inclinations. Measurement 111:18–28, 2017.CrossRef Wojciechowski, S., Maruda, R. W., Barrans, S., Nieslony, P., and Krolczyk, G. M., Optimisation of machining parameters during ball end milling of hardened steel with various surface inclinations. Measurement 111:18–28, 2017.CrossRef
2.
go back to reference Jarosz, K., Löschner, P., Niesłony, P., and Krolczyk, G., Optimization of CNC face milling process of Al-6061-T6 aluminum alloy. J. Mach. Eng. 17(1):69–77, 2017. Jarosz, K., Löschner, P., Niesłony, P., and Krolczyk, G., Optimization of CNC face milling process of Al-6061-T6 aluminum alloy. J. Mach. Eng. 17(1):69–77, 2017.
3.
go back to reference Ruggiero, A., Merola, M., and Affatato, S., On the biotribology of total knee replacement: A new roughness measurements protocol on in vivo condyles considering the dynamic loading from musculoskeletal multibody model. Measurement 112:22–28, 2017.CrossRef Ruggiero, A., Merola, M., and Affatato, S., On the biotribology of total knee replacement: A new roughness measurements protocol on in vivo condyles considering the dynamic loading from musculoskeletal multibody model. Measurement 112:22–28, 2017.CrossRef
4.
go back to reference Merola, M., Ruggiero, A., De Mattia, J. S., and Affatato, S., On the tribological behavior of retrieved hip femoral heads affected by metallic debris. A comparative investigation by stylus and optical profilometer for a new roughness measurement protocol. Measurement 90:365–371, 2016.CrossRef Merola, M., Ruggiero, A., De Mattia, J. S., and Affatato, S., On the tribological behavior of retrieved hip femoral heads affected by metallic debris. A comparative investigation by stylus and optical profilometer for a new roughness measurement protocol. Measurement 90:365–371, 2016.CrossRef
5.
go back to reference Ruggiero, A., Merola, M., and Affatato, S., Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a musculoskeletal model during walking. Materials (Basel). 11(4):574, 2018.CrossRef Ruggiero, A., Merola, M., and Affatato, S., Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a musculoskeletal model during walking. Materials (Basel). 11(4):574, 2018.CrossRef
6.
go back to reference Ruggiero, A., D’Amato, R., and Gómez, E., Experimental analysis of tribological behavior of UHMWPE against AISI420C and against TiAl6V4 alloy under dry and lubricated conditions. Tribol. Int. 92:154–161, 2015.CrossRef Ruggiero, A., D’Amato, R., and Gómez, E., Experimental analysis of tribological behavior of UHMWPE against AISI420C and against TiAl6V4 alloy under dry and lubricated conditions. Tribol. Int. 92:154–161, 2015.CrossRef
7.
go back to reference Ruggiero, A., D’Amato, R., Gómez, E., and Merola, M., Experimental comparison on tribological pairs UHMWPE/TIAL6V4 alloy, UHMWPE/AISI316L austenitic stainless and UHMWPE/AL2O3 ceramic, under dry and lubricated conditions. Tribol. Int. 96:349–360, 2016.CrossRef Ruggiero, A., D’Amato, R., Gómez, E., and Merola, M., Experimental comparison on tribological pairs UHMWPE/TIAL6V4 alloy, UHMWPE/AISI316L austenitic stainless and UHMWPE/AL2O3 ceramic, under dry and lubricated conditions. Tribol. Int. 96:349–360, 2016.CrossRef
8.
go back to reference Ruggiero, A., Gòmez, E., and D’Amato, R., Approximate analytical model for the squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage. Tribol. Lett. 41(2):337–343, 2011.CrossRef Ruggiero, A., Gòmez, E., and D’Amato, R., Approximate analytical model for the squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage. Tribol. Lett. 41(2):337–343, 2011.CrossRef
9.
go back to reference Ruggiero, A., Gómez, E., and D’Amato, R., Approximate closed-form solution of the synovial fluid film force in the human ankle joint with non-Newtonian lubricant. Tribol. Int. 57:156–161, 2013.CrossRef Ruggiero, A., Gómez, E., and D’Amato, R., Approximate closed-form solution of the synovial fluid film force in the human ankle joint with non-Newtonian lubricant. Tribol. Int. 57:156–161, 2013.CrossRef
10.
go back to reference ‘amato, R. D., Calvo, R., and Mez, E. G., Sensitivity study of the morphometric fitting on the pressure field inside ankle joints. Case Stud. Mech. Syst. Signal Process. 1:8–14, 2015. ‘amato, R. D., Calvo, R., and Mez, E. G., Sensitivity study of the morphometric fitting on the pressure field inside ankle joints. Case Stud. Mech. Syst. Signal Process. 1:8–14, 2015.
11.
go back to reference Islan, M., Blaya, F., San Pedro, P., D’Amato, R., Lechosa Urquijo, E., and Juanes, J. A., Analysis and fem simulation methodology of dynamic behavior of human rotator cuff in repetitive routines: Musician case study. J. Med. Syst. 42(3), 2018. Islan, M., Blaya, F., San Pedro, P., D’Amato, R., Lechosa Urquijo, E., and Juanes, J. A., Analysis and fem simulation methodology of dynamic behavior of human rotator cuff in repetitive routines: Musician case study. J. Med. Syst. 42(3), 2018.
12.
go back to reference Marcos, M. I., Urquijo, E. L., Haro, F. B., D’Amato, R., Juanes, J. A., and Heras, E. S., Finite element simulation and analysis of the behavior under load of a human shoulder. In Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality - TEEM’18, 2018, pp 454–461. Marcos, M. I., Urquijo, E. L., Haro, F. B., D’Amato, R., Juanes, J. A., and Heras, E. S., Finite element simulation and analysis of the behavior under load of a human shoulder. In Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality - TEEM’18, 2018, pp 454–461.
13.
go back to reference Haro, F. B., Pedro, P. S., Pedro, A. B. S., Lopez-Silva, J., Juanes, J. A., and D’Amato, R., Design and prototyping by additive manufacturing of a functional splint for rehabilitation of Achilles tendon intrasubstance rupture. In Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality - TEEM’18, 2018, pp 433–439. Haro, F. B., Pedro, P. S., Pedro, A. B. S., Lopez-Silva, J., Juanes, J. A., and D’Amato, R., Design and prototyping by additive manufacturing of a functional splint for rehabilitation of Achilles tendon intrasubstance rupture. In Proceedings of the Sixth International Conference on Technological Ecosystems for Enhancing Multiculturality - TEEM’18, 2018, pp 433–439.
14.
go back to reference Blaya, F., San Pedro, P., López Silva, J., D’Amato, R., Soriano Heras, E., and Antonio Juanes, J., Design of an Orthopedic Product by using additive manufacturing technology: The arm splint. J. Med. Syst. 42:3, 2018.CrossRef Blaya, F., San Pedro, P., López Silva, J., D’Amato, R., Soriano Heras, E., and Antonio Juanes, J., Design of an Orthopedic Product by using additive manufacturing technology: The arm splint. J. Med. Syst. 42:3, 2018.CrossRef
15.
go back to reference Calderon, A., Griffin, J., and Zagal, J. C., BeamMaker: An open hardware high-resolution digital fabricator for the masses. Rapid Prototyp. J. 20(3):245–255, 2014.CrossRef Calderon, A., Griffin, J., and Zagal, J. C., BeamMaker: An open hardware high-resolution digital fabricator for the masses. Rapid Prototyp. J. 20(3):245–255, 2014.CrossRef
16.
go back to reference Mota, C., The rise of personal fabrication. In Proceedings of the 8th ACM conference on Creativity and cognition - C&C ‘11, 2011, p 279. Mota, C., The rise of personal fabrication. In Proceedings of the 8th ACM conference on Creativity and cognition - C&C ‘11, 2011, p 279.
17.
go back to reference Stemp-Morlock, G., and Graeme, Personal fabrication. Commun. ACM 53(10):14, 2010.CrossRef Stemp-Morlock, G., and Graeme, Personal fabrication. Commun. ACM 53(10):14, 2010.CrossRef
18.
go back to reference Stopp, S., Wolff, T., Irlinger, F., and Lueth, T., A new method for printer calibration and contour accuracy manufacturing with 3D-print technology. Rapid Prototyp. J. 14(3):167–172, 2008.CrossRef Stopp, S., Wolff, T., Irlinger, F., and Lueth, T., A new method for printer calibration and contour accuracy manufacturing with 3D-print technology. Rapid Prototyp. J. 14(3):167–172, 2008.CrossRef
19.
go back to reference Hashemi Sanatgar, R., Campagne, C., and Nierstrasz, V., Investigation of the adhesion properties of direct 3D printing of polymers and nanocomposites on textiles: Effect of FDM printing process parameters. Appl. Surf. Sci. 403:551–563, 2017.CrossRef Hashemi Sanatgar, R., Campagne, C., and Nierstrasz, V., Investigation of the adhesion properties of direct 3D printing of polymers and nanocomposites on textiles: Effect of FDM printing process parameters. Appl. Surf. Sci. 403:551–563, 2017.CrossRef
20.
go back to reference Stabile, L., Scungio, M., Buonanno, G., Arpino, F., and Ficco, G., Airborne particle emission of a commercial 3D printer: The effect of filament material and printing temperature. Indoor Air 27(2):398–408, 2017.CrossRef Stabile, L., Scungio, M., Buonanno, G., Arpino, F., and Ficco, G., Airborne particle emission of a commercial 3D printer: The effect of filament material and printing temperature. Indoor Air 27(2):398–408, 2017.CrossRef
21.
go back to reference Reutzel, E. W. and Nassar, A. R., A survey of sensing and control systems for machine and process monitoring of directedenergy, metal-based additive manufacturing. Rapid Prototyp. J. 21(2). Emerald Group Publishing Ltd., pp. 159–167, 16-Mar-2015. Reutzel, E. W. and Nassar, A. R., A survey of sensing and control systems for machine and process monitoring of directedenergy, metal-based additive manufacturing. Rapid Prototyp. J. 21(2). Emerald Group Publishing Ltd., pp. 159–167, 16-Mar-2015.
22.
go back to reference Soriano Heras, E., Blaya Haro, F., de Agustín del Burgo, J. M., Islán Marcos, M., and D’Amato, R., Filament advance detection sensor for fused deposition modelling 3D printers. Sensors (Switzerland) 18(5):1495, 2018.CrossRef Soriano Heras, E., Blaya Haro, F., de Agustín del Burgo, J. M., Islán Marcos, M., and D’Amato, R., Filament advance detection sensor for fused deposition modelling 3D printers. Sensors (Switzerland) 18(5):1495, 2018.CrossRef
23.
go back to reference Soriano Heras, E., Blaya Haro, F., de Agustín del Burgo, J., Islán Marcos, M., and D’Amato, R., Filament advance detection sensor for fused deposition modelling 3D printers. Sensors 18(5):1495, 2018.CrossRef Soriano Heras, E., Blaya Haro, F., de Agustín del Burgo, J., Islán Marcos, M., and D’Amato, R., Filament advance detection sensor for fused deposition modelling 3D printers. Sensors 18(5):1495, 2018.CrossRef
24.
go back to reference Volpato, N., Kretschek, D., Foggiatto, J. A., and Gomez da Silva Cruz, C. M., Experimental analysis of an extrusion system for additive manufacturing based on polymer pellets. Int. J. Adv. Manuf. Technol. 81(9–12):1519–1531, 2015.CrossRef Volpato, N., Kretschek, D., Foggiatto, J. A., and Gomez da Silva Cruz, C. M., Experimental analysis of an extrusion system for additive manufacturing based on polymer pellets. Int. J. Adv. Manuf. Technol. 81(9–12):1519–1531, 2015.CrossRef
25.
go back to reference Turner, B. N., and Gold, S. A., A review of melt extrusion additive manufacturing processes: II. Materials, dimensional accuracy, and surface roughness. Rapid Prototyp. J. 21(3):250–261, 2015.CrossRef Turner, B. N., and Gold, S. A., A review of melt extrusion additive manufacturing processes: II. Materials, dimensional accuracy, and surface roughness. Rapid Prototyp. J. 21(3):250–261, 2015.CrossRef
26.
go back to reference Habibovic, P., Gbureck, U., Doillon, C. J., Bassett, D. C., van Blitterswijk, C. A., and Barralet, J. E., Osteoconduction and osteoinduction of low-temperature 3D printed bioceramic implants. Biomaterials 29(7):944–953, 2008.CrossRef Habibovic, P., Gbureck, U., Doillon, C. J., Bassett, D. C., van Blitterswijk, C. A., and Barralet, J. E., Osteoconduction and osteoinduction of low-temperature 3D printed bioceramic implants. Biomaterials 29(7):944–953, 2008.CrossRef
Metadata
Title
Monitoring an Analysis of Perturbations in Fusion Deposition Modelling (FDM) Processes for the Use of Biomaterials
Authors
Fernando Blaya Haro
José María de Agustín del Burgo
Roberto D’Amato
Manuel Islán
Enrique Soriano Heras
Jesus Manuel Garcia Alonso
Juan Antonio Juanes Mendez
Publication date
01-05-2019
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2019
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-019-1236-2

Other articles of this Issue 5/2019

Journal of Medical Systems 5/2019 Go to the issue