Skip to main content
Top
Published in: Journal of Cardiothoracic Surgery 1/2013

Open Access 01-12-2013 | Research article

Mixed venous O2 saturation and fluid responsiveness after cardiac or major vascular surgery

Authors: Arjan N Kuiper, Ronald J Trof, AB Johan Groeneveld

Published in: Journal of Cardiothoracic Surgery | Issue 1/2013

Login to get access

Abstract

Background

It is unclear if and how SvO2 can serve as an indicator of fluid responsiveness in patients after cardiac or major vascular surgery.

Methods

This was a substudy of a randomized single-blinded clinical trial reported earlier on critically ill patients with clinical hypovolemia after cardiac or major vascular surgery. Colloid fluid loading was done for 90 min, guided by changes in pulmonary artery occlusion pressure (PAOP) or central venous pressure (CVP). Fluid responsiveness was defined as ≥15% increase in cardiac index (CI). Hemodynamics, including transpulmonary dilution-derived global end-diastolic volume index (GEDVI) and global ejection fraction (GEF), were measured and blood samples taken.

Results

Whereas baseline SvO2 (>70% in 68% of patients) did not differ, the SvO2 increased in patients responding to fluid loading (≥15% in CI in n = 26) versus those not responding (n = 11; P = 0.03). The increase in GEDVI was also greater in responders (P = 0.005). The area under the receiver operating characteristic curve for fluid responsiveness of changes in SvO2 was 0.73 (P = 0.007), with an optimal cutoff of 2%, and of those in GEDVI 0.82 (P < 0.001), while the areas did not differ. However, the value of SvO2 increases to reflect CI increases with fluid loading was greatest when GEF was ≤20% (in 53% of patients).

Conclusions

An increase in SvO2 ≥2%, irrespective of a relatively high baseline value, can thus be used as a monitor of fluid responsiveness in clinically hypovolemic patients after cardiac or major vascular surgery, particularly in those with systolic cardiac dysfunction. Fluid responsiveness concurs with increased tissue O2 delivery.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gattinoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R, for the SvO2 collaborative group: A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med. 1995, 16: 1025-1032.CrossRef Gattinoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R, for the SvO2 collaborative group: A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med. 1995, 16: 1025-1032.CrossRef
2.
go back to reference Ziegler DW, Wright JG, Choban PS, Flancbaum L: A prospective randomized trial of preoperative “optimization” of cardiac function in patients undergoing elective peripheral vascular surgery. Surg. 1997, 122: 584-592. 10.1016/S0039-6060(97)90132-X.CrossRef Ziegler DW, Wright JG, Choban PS, Flancbaum L: A prospective randomized trial of preoperative “optimization” of cardiac function in patients undergoing elective peripheral vascular surgery. Surg. 1997, 122: 584-592. 10.1016/S0039-6060(97)90132-X.CrossRef
3.
go back to reference Pölönen P, Ruokonen E, Hippeläinen M, Pöyhönen M, Takala J: A prospective, randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients. Anesth Analg. 2000, 90: 1052-1059. 10.1097/00000539-200005000-00010.CrossRefPubMed Pölönen P, Ruokonen E, Hippeläinen M, Pöyhönen M, Takala J: A prospective, randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients. Anesth Analg. 2000, 90: 1052-1059. 10.1097/00000539-200005000-00010.CrossRefPubMed
4.
go back to reference Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB: Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006, 32: 1030-1038. 10.1007/s00134-006-0195-5.CrossRefPubMed Verheij J, van Lingen A, Beishuizen A, Christiaans HM, de Jong JR, Girbes AR, Wisselink W, Rauwerda JA, Huybregts MA, Groeneveld AB: Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med. 2006, 32: 1030-1038. 10.1007/s00134-006-0195-5.CrossRefPubMed
5.
go back to reference Goepfert MSG, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz AE: Goal-directed therapy reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med. 2007, 33: 96-103. 10.1007/s00134-006-0404-2.CrossRefPubMed Goepfert MSG, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz AE: Goal-directed therapy reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med. 2007, 33: 96-103. 10.1007/s00134-006-0404-2.CrossRefPubMed
6.
go back to reference Marik PE, Baram M, Vahid B: Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008, 134: 172-178. 10.1378/chest.07-2331.CrossRefPubMed Marik PE, Baram M, Vahid B: Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008, 134: 172-178. 10.1378/chest.07-2331.CrossRefPubMed
7.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590da.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590da.CrossRefPubMed
8.
go back to reference Trof RJ, Danad I, Reilingh MW, Breukers RM, Groeneveld AB: Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function. Crit Care. 2011, 15: R73-10.1186/cc10062.CrossRefPubMedPubMedCentral Trof RJ, Danad I, Reilingh MW, Breukers RM, Groeneveld AB: Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function. Crit Care. 2011, 15: R73-10.1186/cc10062.CrossRefPubMedPubMedCentral
9.
go back to reference Vedrinne C, Bastien O, De Varax R, Blanc P, Durand PG, Du Grès B, Bouvier H, Saroul C, Lehot JJ: Predictive factors for usefulness of fiberoptic pulmonary artery catheter for continuous oxygen saturation in mixed venous blood monitoring in cardiac surgery. Anesth Analg. 1997, 85: 2-10.PubMed Vedrinne C, Bastien O, De Varax R, Blanc P, Durand PG, Du Grès B, Bouvier H, Saroul C, Lehot JJ: Predictive factors for usefulness of fiberoptic pulmonary artery catheter for continuous oxygen saturation in mixed venous blood monitoring in cardiac surgery. Anesth Analg. 1997, 85: 2-10.PubMed
10.
go back to reference Lequeux PY, Bouckaert Y, Sekkat H, van der Linden P, Stefanidis C, Huynh CH, Beijani G, Bredas P: Continuous mixed venous and central venous oxygen saturation in cardiac surgery with cardiopulmonary bypass. Eur J Anaesthesiol. 2010, 27: 295-299. 10.1097/EJA.0b013e3283315ad0.CrossRefPubMed Lequeux PY, Bouckaert Y, Sekkat H, van der Linden P, Stefanidis C, Huynh CH, Beijani G, Bredas P: Continuous mixed venous and central venous oxygen saturation in cardiac surgery with cardiopulmonary bypass. Eur J Anaesthesiol. 2010, 27: 295-299. 10.1097/EJA.0b013e3283315ad0.CrossRefPubMed
11.
go back to reference Van B, Wietasch G, Scheeren T, Spronk P, Kuiper M: Clinical review: use of venous oxygen saturations as a goal-a yet unfinished puzzle. Crit Care. 2011, 15: 232-10.1186/cc10351.CrossRef Van B, Wietasch G, Scheeren T, Spronk P, Kuiper M: Clinical review: use of venous oxygen saturations as a goal-a yet unfinished puzzle. Crit Care. 2011, 15: 232-10.1186/cc10351.CrossRef
12.
go back to reference Walley KR: Use of central venous oxygen saturation to guide therapy. Am J Respir Crit. 2011, 184: 514-520. 10.1164/rccm.201010-1584CI.CrossRef Walley KR: Use of central venous oxygen saturation to guide therapy. Am J Respir Crit. 2011, 184: 514-520. 10.1164/rccm.201010-1584CI.CrossRef
13.
go back to reference Viale JP, Annat GJ, Ravat FM, Pommier CM, Brudon JR, Desuzinges CJ, Bertrand OM, Motin JP: Oxygen uptake and mixed venous oxygen saturation during aortic surgery and the first three postoperative hours. Anesth Analg. 1991, 73: 530-535.CrossRefPubMed Viale JP, Annat GJ, Ravat FM, Pommier CM, Brudon JR, Desuzinges CJ, Bertrand OM, Motin JP: Oxygen uptake and mixed venous oxygen saturation during aortic surgery and the first three postoperative hours. Anesth Analg. 1991, 73: 530-535.CrossRefPubMed
14.
go back to reference Inomata S, Nishikawa T, Taguchi M: Continuous monitoring of mixed venous oxygen saturation for detecting alterations in cardiac output after discontinuation of cardiopulmonary bypass. Br J Anaesth. 1994, 72: 111-116.CrossRef Inomata S, Nishikawa T, Taguchi M: Continuous monitoring of mixed venous oxygen saturation for detecting alterations in cardiac output after discontinuation of cardiopulmonary bypass. Br J Anaesth. 1994, 72: 111-116.CrossRef
15.
go back to reference Viale JP, Annat G, Lehot JJ, Quard S, Quintin L, Parlow J, Durand PG, Zabot JM, Villard J, Estanove S: Relationship between oxygen uptake and mixed venous oxygen saturation in the immediate postoperative period. Anesthesiol. 1994, 80: 278-283. 10.1097/00000542-199402000-00007.CrossRef Viale JP, Annat G, Lehot JJ, Quard S, Quintin L, Parlow J, Durand PG, Zabot JM, Villard J, Estanove S: Relationship between oxygen uptake and mixed venous oxygen saturation in the immediate postoperative period. Anesthesiol. 1994, 80: 278-283. 10.1097/00000542-199402000-00007.CrossRef
16.
go back to reference Svedjeholm R, Håkanson E, Szabó Z: Routine SvO2 measurement after CABG surgery with a surgically introduced pulmonary artery catheter. Eur J Cardiothor Surg. 1999, 16: 450-457. 10.1016/S1010-7940(99)00287-0.CrossRef Svedjeholm R, Håkanson E, Szabó Z: Routine SvO2 measurement after CABG surgery with a surgically introduced pulmonary artery catheter. Eur J Cardiothor Surg. 1999, 16: 450-457. 10.1016/S1010-7940(99)00287-0.CrossRef
17.
go back to reference Krantz T, Warberg J, Secher NH: Venous oxygen saturation during normovolaemic haemodilution in the pig. Acta Anaesthesiol Scand. 2005, 49: 1149-1156. 10.1111/j.1399-6576.2005.00778.x.CrossRefPubMed Krantz T, Warberg J, Secher NH: Venous oxygen saturation during normovolaemic haemodilution in the pig. Acta Anaesthesiol Scand. 2005, 49: 1149-1156. 10.1111/j.1399-6576.2005.00778.x.CrossRefPubMed
18.
go back to reference Caille V, Squara P: Oxygen uptake-to-delivery relationship; a way to assess adequate flow. Crit Care. 2006, 10 ((Suppl 3)S4): 1-7. Caille V, Squara P: Oxygen uptake-to-delivery relationship; a way to assess adequate flow. Crit Care. 2006, 10 ((Suppl 3)S4): 1-7.
19.
go back to reference Monnet X, Julien F, Ait-Hamou N, Lequoy M, Gosset C, Jozwiak M, Persichini R, Anguel N, Richard C, Teboul JL: Lactate and veno-arterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders. Crit Care Med. 2013, In press Monnet X, Julien F, Ait-Hamou N, Lequoy M, Gosset C, Jozwiak M, Persichini R, Anguel N, Richard C, Teboul JL: Lactate and veno-arterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders. Crit Care Med. 2013, In press
20.
go back to reference Giraud R, Siegenthaler N, Gayet-Ageron A, Combescure C, Romand JA, Bendjelid K: ScvO2 as a marker to define fluid responsiveness. J Trauma. 2011, 70: 802-807. 10.1097/TA.0b013e3181e7d649.CrossRefPubMed Giraud R, Siegenthaler N, Gayet-Ageron A, Combescure C, Romand JA, Bendjelid K: ScvO2 as a marker to define fluid responsiveness. J Trauma. 2011, 70: 802-807. 10.1097/TA.0b013e3181e7d649.CrossRefPubMed
21.
go back to reference Velissaris D, Pierrakos C, Scoletta S: High mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients. Crit Care. 2011, 15: R177-CrossRefPubMedPubMedCentral Velissaris D, Pierrakos C, Scoletta S: High mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients. Crit Care. 2011, 15: R177-CrossRefPubMedPubMedCentral
22.
go back to reference Breukers RM, de Wilde RB, van den Berg PC, Jansen JR, Faes TJ, Twisk JW, Groeneveld AB: Assessing fluid responses after coronary surgery: role of mathematical coupling of global end-diastolic volume to cardiac output measured by transpulmonary thermodilution. Eur J Anaesthesiol. 2009, 26: 954-960. 10.1097/EJA.0b013e32833098c6.CrossRefPubMed Breukers RM, de Wilde RB, van den Berg PC, Jansen JR, Faes TJ, Twisk JW, Groeneveld AB: Assessing fluid responses after coronary surgery: role of mathematical coupling of global end-diastolic volume to cardiac output measured by transpulmonary thermodilution. Eur J Anaesthesiol. 2009, 26: 954-960. 10.1097/EJA.0b013e32833098c6.CrossRefPubMed
23.
go back to reference Breukers RM, Groeneveld AB, de Wilde RB, Jansen JR: Transpulmonary versus continuous thermodilution cardiac output after valvular and coronary artery surgery. Interact Cardiovasc Thorac Surg. 2009, 9: 4-8. 10.1510/icvts.2009.204545.CrossRefPubMed Breukers RM, Groeneveld AB, de Wilde RB, Jansen JR: Transpulmonary versus continuous thermodilution cardiac output after valvular and coronary artery surgery. Interact Cardiovasc Thorac Surg. 2009, 9: 4-8. 10.1510/icvts.2009.204545.CrossRefPubMed
24.
go back to reference Hofer CK, Furrer L, Matter-Ensner S, Malogigne M, Klaghofer R, Genoni M, Zollinger A: Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005, 94: 748-755. 10.1093/bja/aei123.CrossRefPubMed Hofer CK, Furrer L, Matter-Ensner S, Malogigne M, Klaghofer R, Genoni M, Zollinger A: Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005, 94: 748-755. 10.1093/bja/aei123.CrossRefPubMed
25.
go back to reference Kuiper AN, Trof RJ, Groeneveld AB: S(CV)O2 is not a universal indicator of fluid responsiveness. J Trauma. 2011, 71: 518-519.CrossRefPubMed Kuiper AN, Trof RJ, Groeneveld AB: S(CV)O2 is not a universal indicator of fluid responsiveness. J Trauma. 2011, 71: 518-519.CrossRefPubMed
Metadata
Title
Mixed venous O2 saturation and fluid responsiveness after cardiac or major vascular surgery
Authors
Arjan N Kuiper
Ronald J Trof
AB Johan Groeneveld
Publication date
01-12-2013
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2013
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/1749-8090-8-189

Other articles of this Issue 1/2013

Journal of Cardiothoracic Surgery 1/2013 Go to the issue