Published in: International Orthopaedics 6/2008

01-12-2008 | Original Paper

Migration of the Duraloc cup after 5 years

Authors: Christoph Stihsen, Christof Pabinger, Roman Radl, Peter Rehak, Reinhard Windhager

Published in: International Orthopaedics | Issue 6/2008

Login to get access

Abstract

The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters ≥54 mm migrated significantly more than cups <54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).
Literature
1.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
2.
go back to reference Girard J, Laffargue P, Decoulx J, Migaud H (2005) Reliability of porous coating metal-backed cups: advantages and adverse effect of a posterior elevated rim polyethylene liner (in French). Rev Chir Orthop Reparatrice Appar Mot 91:432–438PubMed Girard J, Laffargue P, Decoulx J, Migaud H (2005) Reliability of porous coating metal-backed cups: advantages and adverse effect of a posterior elevated rim polyethylene liner (in French). Rev Chir Orthop Reparatrice Appar Mot 91:432–438PubMed
3.
go back to reference Grobler GP, Learmonth ID, Bernstein BP, Dower BJ (2005) Ten-year results of a press-fit, porous-coated acetabular component. J Bone Joint Surg Br 87:786–789PubMedCrossRef Grobler GP, Learmonth ID, Bernstein BP, Dower BJ (2005) Ten-year results of a press-fit, porous-coated acetabular component. J Bone Joint Surg Br 87:786–789PubMedCrossRef
4.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
5.
go back to reference Hintermann B, Morscher EW (1995) Total hip replacement with solid autologous femoral head graft for hip dysplasia. Arch Orthop Trauma Surg 114:137–144PubMedCrossRef Hintermann B, Morscher EW (1995) Total hip replacement with solid autologous femoral head graft for hip dysplasia. Arch Orthop Trauma Surg 114:137–144PubMedCrossRef
6.
go back to reference Ilchmann T, Franzen H, Mjoberg B, Wingstrand H (1992) Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 7:121–127PubMedCrossRef Ilchmann T, Franzen H, Mjoberg B, Wingstrand H (1992) Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis. J Arthroplasty 7:121–127PubMedCrossRef
7.
go back to reference Ilchmann T, Freeman MA, Mjoberg B (1992) Accuracy of the Nunn method in measuring acetabular cup migration. Ups J Med Sci 97:67–68PubMedCrossRef Ilchmann T, Freeman MA, Mjoberg B (1992) Accuracy of the Nunn method in measuring acetabular cup migration. Ups J Med Sci 97:67–68PubMedCrossRef
8.
go back to reference Kim YH (2002) Cementless total hip arthroplasty with a close proximal fit and short tapered distal stem (third-generation) prosthesis. J Arthroplasty 17:841–850PubMedCrossRef Kim YH (2002) Cementless total hip arthroplasty with a close proximal fit and short tapered distal stem (third-generation) prosthesis. J Arthroplasty 17:841–850PubMedCrossRef
9.
go back to reference Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85:109–114PubMedCrossRef Kim YH, Oh SH, Kim JS (2003) Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J Bone Joint Surg Am 85:109–114PubMedCrossRef
10.
go back to reference Krismer M, Fischer M, Mayrhofer P, Stockl F, Bittner C, Trojer C, Stockl B (1994) A prospective study of the migration of two acetabular components. PCA versus RM cups. Int Orthop 18:23–28PubMedCrossRef Krismer M, Fischer M, Mayrhofer P, Stockl F, Bittner C, Trojer C, Stockl B (1994) A prospective study of the migration of two acetabular components. PCA versus RM cups. Int Orthop 18:23–28PubMedCrossRef
11.
go back to reference Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225–1236PubMedCrossRef Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28:1225–1236PubMedCrossRef
12.
go back to reference Krismer M, Stockl B, Fischer M, Bauer R, Mayrhofer P, Ogon M (1996) Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg Br 78:422–426PubMed Krismer M, Stockl B, Fischer M, Bauer R, Mayrhofer P, Ogon M (1996) Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg Br 78:422–426PubMed
13.
go back to reference Krismer M, Biedermann R, Stöckl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. J Bone Joint Surg Br 81:273–280PubMedCrossRef Krismer M, Biedermann R, Stöckl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. J Bone Joint Surg Br 81:273–280PubMedCrossRef
14.
go back to reference Mjoberg B (1991) Fixation and loosening of hip prostheses. A review. Acta Orthop Scand 62:500–508PubMedCrossRef Mjoberg B (1991) Fixation and loosening of hip prostheses. A review. Acta Orthop Scand 62:500–508PubMedCrossRef
15.
go back to reference Phillips NJ, Stockley I, Wilkinson JM (2002) Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 17:917–925PubMedCrossRef Phillips NJ, Stockley I, Wilkinson JM (2002) Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 17:917–925PubMedCrossRef
16.
go back to reference Stocks GW, Freeman MAR, Evans SJW (1995) Acetabular cup migration. Prediction of aseptic loosening. J Bone Joint Surg Br 77:853–861PubMed Stocks GW, Freeman MAR, Evans SJW (1995) Acetabular cup migration. Prediction of aseptic loosening. J Bone Joint Surg Br 77:853–861PubMed
17.
go back to reference Stöckl B, Sandow M, Krismer M, Biedermann R, Wimmer C, Frischhut B (1999) Migration of the Duraloc cup at two years. J Bone Joint Surg Br 81:51–53PubMedCrossRef Stöckl B, Sandow M, Krismer M, Biedermann R, Wimmer C, Frischhut B (1999) Migration of the Duraloc cup at two years. J Bone Joint Surg Br 81:51–53PubMedCrossRef
18.
go back to reference Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R (2005) Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop 29:14–17PubMedCrossRef Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R (2005) Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop 29:14–17PubMedCrossRef
19.
go back to reference Takatori Y, Ninomiya S, Umeyama T, Yamamoto M, Moro T, Nakamura K (2002) Bipolar revision arthroplasty for failed threaded acetabular components: radiographic evaluation of cup migration. J Orthop Sci 7:467–471PubMedCrossRef Takatori Y, Ninomiya S, Umeyama T, Yamamoto M, Moro T, Nakamura K (2002) Bipolar revision arthroplasty for failed threaded acetabular components: radiographic evaluation of cup migration. J Orthop Sci 7:467–471PubMedCrossRef
20.
go back to reference Vernois J, Gabrion A, Havet E, Gaullier O, Mertl P (2004) The cementless Duraloc acetabular component: 100 cases assessed after a minimum five year follow-up (in French). Rev Chir Orthop Reparatrice Appar Mot 90:434–441PubMed Vernois J, Gabrion A, Havet E, Gaullier O, Mertl P (2004) The cementless Duraloc acetabular component: 100 cases assessed after a minimum five year follow-up (in French). Rev Chir Orthop Reparatrice Appar Mot 90:434–441PubMed
21.
go back to reference Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30:473–483PubMedCrossRef Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30:473–483PubMedCrossRef
22.
go back to reference Wilkinson JM, Hamer AJ, Elson RA, Stockley I, Eastell R (2002) Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 17:910–916PubMedCrossRef Wilkinson JM, Hamer AJ, Elson RA, Stockley I, Eastell R (2002) Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 17:910–916PubMedCrossRef
Metadata
Title
Migration of the Duraloc cup after 5 years
Authors
Christoph Stihsen
Christof Pabinger
Roman Radl
Peter Rehak
Reinhard Windhager
Publication date
01-12-2008
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2008
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0405-y

Other articles of this Issue 6/2008

International Orthopaedics 6/2008 Go to the issue