Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2012

01-08-2012 | Knee

Mid-term clinical results of alumina medial pivot total knee arthroplasty

Authors: Takahiro Iida, Yukihide Minoda, Yoshinori Kadoya, Yoshio Matsui, Akio Kobayashi, Hiroyoshi Iwaki, Mitsuhiko Ikebuchi, Taku Yoshida, Hiroaki Nakamura

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 8/2012

Login to get access

Abstract

Purpose

The medial pivot total knee prosthesis has been designed to reproduce physiological knee kinematics. It has been reported that alumina ceramic femoral components reduce polyethylene wear. Thus, medial pivot total knee prostheses with alumina ceramic femoral components were introduced. The purpose of this study was to evaluate the clinical results of patients who underwent newly introduced alumina medial pivot total knee arthroplasties (TKA).

Methods

We evaluated the clinical results of 107 alumina medial pivot TKAs in 80 consecutive patients with a mean follow-up period of 5 years.

Results

Alumina medial pivot TKAs provided significant improvements in the patients’ Knee Society knee scores, function scores and post-operative ranges of motion compared with their pre-operative statuses (each, P < 0.05). There was no statistical correlation between the change in maximum knee flexion and the increase in posterior condylar offset. Revision surgery was required in one knee due to a post-operative fracture of the tibial plateau after a fall that occurred 2 years postoperatively. No knees had aseptic loosening, osteolysis, or ceramic fractures. The survival rate was 98.6% at 5 years.

Conclusions

This study demonstrates satisfactory mid-term clinical results for patients receiving the alumina medial pivot prosthesis.

Level of evidence

Therapeutic study, Level IV.
Literature
1.
go back to reference Akagi M, Nakamura T, Matsusue Y, Ueo T, Nishijyo K, Ohnishi E (2000) The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study. J Bone Joint Surg Am 82:1626–1633PubMed Akagi M, Nakamura T, Matsusue Y, Ueo T, Nishijyo K, Ohnishi E (2000) The Bisurface total knee replacement: a unique design for flexion. Four-to-nine-year follow-up study. J Bone Joint Surg Am 82:1626–1633PubMed
2.
go back to reference Anderson MJ, Kruse RL, Leslie C, Levy LJ Jr, Pritchett JW, Hodge J (2010) Medium-term results of total knee arthroplasty using a medially pivoting implant: a multicenter study. J Surg Orthop Adv 19:191–195PubMed Anderson MJ, Kruse RL, Leslie C, Levy LJ Jr, Pritchett JW, Hodge J (2010) Medium-term results of total knee arthroplasty using a medially pivoting implant: a multicenter study. J Surg Orthop Adv 19:191–195PubMed
3.
go back to reference Bae DK, Song SJ, Cho SD (2011) Clinical outcome of total knee arthroplasty with medial pivot prosthesis a comparative study between the cruciate retaining and sacrificing. J Arthroplasty 26:693–698PubMedCrossRef Bae DK, Song SJ, Cho SD (2011) Clinical outcome of total knee arthroplasty with medial pivot prosthesis a comparative study between the cruciate retaining and sacrificing. J Arthroplasty 26:693–698PubMedCrossRef
4.
go back to reference Bal BS, Garino J, Ries M, Oonishi H (2007) Ceramic bearings in total knee arthroplasty. J Knee Surg 20:261–270PubMed Bal BS, Garino J, Ries M, Oonishi H (2007) Ceramic bearings in total knee arthroplasty. J Knee Surg 20:261–270PubMed
5.
go back to reference Barnes CL, Sharma A, Blaha JD, Nambu SN, Carroll ME (2011) Kneeling is safe for patients implanted with medial-pivot total knee arthroplasty designs. J Arthroplasty 26:549–554PubMedCrossRef Barnes CL, Sharma A, Blaha JD, Nambu SN, Carroll ME (2011) Kneeling is safe for patients implanted with medial-pivot total knee arthroplasty designs. J Arthroplasty 26:549–554PubMedCrossRef
6.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef
7.
8.
go back to reference Cooper J, Dowson D, Fisher J, Jobbins B (1991) Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. J Med Eng Technol 15:63–67PubMedCrossRef Cooper J, Dowson D, Fisher J, Jobbins B (1991) Ceramic bearing surfaces in total artificial joints: resistance to third body wear damage from bone cement particles. J Med Eng Technol 15:63–67PubMedCrossRef
9.
go back to reference Dennis DA, Komistek RD, Mahfouz MR (2003) In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res 410:114–130PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR (2003) In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res 410:114–130PubMedCrossRef
10.
go back to reference Ewald F (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald F (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
11.
go back to reference Fan C, Hsieh J, Hsieh M, Shih Y, Lee C (2010) Primitive results after medial-pivot knee arthroplasties a minimum 5-year follow-up study. J Arthroplasty 25:492–496PubMedCrossRef Fan C, Hsieh J, Hsieh M, Shih Y, Lee C (2010) Primitive results after medial-pivot knee arthroplasties a minimum 5-year follow-up study. J Arthroplasty 25:492–496PubMedCrossRef
12.
go back to reference Hanratty B, Thompson N, Wilson R, Beverland D (2007) The influence of posterior condylar offset on knee flexion after total knee replacement using a cruciate-sacrificing mobile-bearing implant. J Bone Joint Surg Br 89:915–918PubMedCrossRef Hanratty B, Thompson N, Wilson R, Beverland D (2007) The influence of posterior condylar offset on knee flexion after total knee replacement using a cruciate-sacrificing mobile-bearing implant. J Bone Joint Surg Br 89:915–918PubMedCrossRef
13.
go back to reference Hossain F, Patel S, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228PubMedCrossRef Hossain F, Patel S, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228PubMedCrossRef
14.
go back to reference Insall J, Dorr L, Scott R, Scott W (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall J, Dorr L, Scott R, Scott W (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
15.
go back to reference Iwaki H, Pinskerova V, Freeman M (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82:1189–1195PubMedCrossRef Iwaki H, Pinskerova V, Freeman M (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82:1189–1195PubMedCrossRef
16.
go back to reference Iwakiri K, Kobayashi A, Minoda Y, Iwaki H, Kadoya Y, Ohashi H, Takaoka K (2007) Difference between lowest points and contact points as a reference in 3D kinematic analysis of medial pivot knee arthroplasty. Trans Orthop Res Soc 32:1826 Iwakiri K, Kobayashi A, Minoda Y, Iwaki H, Kadoya Y, Ohashi H, Takaoka K (2007) Difference between lowest points and contact points as a reference in 3D kinematic analysis of medial pivot knee arthroplasty. Trans Orthop Res Soc 32:1826
17.
go back to reference Julin J, Jämsen E, Puolakka T, Konttinen YT, Moilanen T (2010) Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish arthroplasty register. Acta Orthop 81:413–419PubMedCrossRef Julin J, Jämsen E, Puolakka T, Konttinen YT, Moilanen T (2010) Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish arthroplasty register. Acta Orthop 81:413–419PubMedCrossRef
18.
go back to reference Karachalios T, Roidis N, Giotikas D, Bargiotas K, Varitimidis S, Malizos K (2009) A mid-term clinical outcome study of the advance medial pivot knee arthroplasty. Knee 16:484–488PubMedCrossRef Karachalios T, Roidis N, Giotikas D, Bargiotas K, Varitimidis S, Malizos K (2009) A mid-term clinical outcome study of the advance medial pivot knee arthroplasty. Knee 16:484–488PubMedCrossRef
19.
go back to reference Kim Y, Yoon S, Kim J (2009) Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis. Clin Orthop Relat Res 467:493–503PubMedCrossRef Kim Y, Yoon S, Kim J (2009) Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis. Clin Orthop Relat Res 467:493–503PubMedCrossRef
20.
go back to reference Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89:780–785PubMedCrossRef
21.
go back to reference Majima T, Yasuda K, Tago H, Aoki Y, Minami A (2008) Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co–Cr alloy prosthesis. Knee Surg Sports Traumatol Arthrosc 16:152–156PubMedCrossRef Majima T, Yasuda K, Tago H, Aoki Y, Minami A (2008) Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co–Cr alloy prosthesis. Knee Surg Sports Traumatol Arthrosc 16:152–156PubMedCrossRef
22.
go back to reference Mannan K, Scott G (2009) The Medial Rotation total knee replacement: a clinical and radiological review at a mean follow-up of six years. J Bone Joint Surg Br 91:750–756PubMedCrossRef Mannan K, Scott G (2009) The Medial Rotation total knee replacement: a clinical and radiological review at a mean follow-up of six years. J Bone Joint Surg Br 91:750–756PubMedCrossRef
23.
go back to reference Min B, Song K, Kang C, Bae K, Won Y, Lee K (2007) Delayed fracture of a ceramic insert with modern ceramic total hip replacement. J Arthroplasty 22:136–139PubMedCrossRef Min B, Song K, Kang C, Bae K, Won Y, Lee K (2007) Delayed fracture of a ceramic insert with modern ceramic total hip replacement. J Arthroplasty 22:136–139PubMedCrossRef
24.
go back to reference Minoda Y, Kobayashi A, Iwaki H, Iwakiri K, Inori F, Sugama R, Ikebuchi M, Kadoya Y, Takaoka K (2009) In vivo analysis of polyethylene wear particles after total knee arthroplasty: the influence of improved materials and designs. J Bone Joint Surg Am 91(Suppl 6):67–73PubMedCrossRef Minoda Y, Kobayashi A, Iwaki H, Iwakiri K, Inori F, Sugama R, Ikebuchi M, Kadoya Y, Takaoka K (2009) In vivo analysis of polyethylene wear particles after total knee arthroplasty: the influence of improved materials and designs. J Bone Joint Surg Am 91(Suppl 6):67–73PubMedCrossRef
25.
go back to reference Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Takaoka K (2005) Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis. Biomaterials 26:6034–6040PubMedCrossRef Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Takaoka K (2005) Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis. Biomaterials 26:6034–6040PubMedCrossRef
26.
go back to reference Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Yamano Y, Takaoka K (2003) Polyethylene wear particles in synovial fluid after total knee arthroplasty. Clin Orthop Relat Res 410:165–172PubMedCrossRef Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Yamano Y, Takaoka K (2003) Polyethylene wear particles in synovial fluid after total knee arthroplasty. Clin Orthop Relat Res 410:165–172PubMedCrossRef
27.
go back to reference Miyazaki Y, Nakamura T, Kogame K, Saito M, Yamamoto K, Suguro T (2010) Analysis of the kinematics of total knee prostheses with a medial pivot design. J Arthroplasty 26:1038–1044PubMedCrossRef Miyazaki Y, Nakamura T, Kogame K, Saito M, Yamamoto K, Suguro T (2010) Analysis of the kinematics of total knee prostheses with a medial pivot design. J Arthroplasty 26:1038–1044PubMedCrossRef
28.
go back to reference Mont M, Booth RJ, Laskin R, Stiehl J, Ritter M, Stuchin S, Rajadhyaksha A (2003) The spectrum of prosthesis design for primary total knee arthroplasty. Instr Course Lect 52:397–407PubMed Mont M, Booth RJ, Laskin R, Stiehl J, Ritter M, Stuchin S, Rajadhyaksha A (2003) The spectrum of prosthesis design for primary total knee arthroplasty. Instr Course Lect 52:397–407PubMed
29.
go back to reference Moonot P, Mu S, Railton G, Field R, Banks S (2009) Tibiofemoral kinematic analysis of knee flexion for a medial pivot knee. Knee Surg Sports Traumatol Arthrosc 17:927–934PubMedCrossRef Moonot P, Mu S, Railton G, Field R, Banks S (2009) Tibiofemoral kinematic analysis of knee flexion for a medial pivot knee. Knee Surg Sports Traumatol Arthrosc 17:927–934PubMedCrossRef
30.
go back to reference Ohnish H (1982) Cementless alumina ceramic total knee prosthesis. Orthop Ceramic Implants 1:157–160 Ohnish H (1982) Cementless alumina ceramic total knee prosthesis. Orthop Ceramic Implants 1:157–160
31.
go back to reference Oonishi H, Aono M, Murata N, Kushitani S (1992) Alumina versus polyethylene in total knee arthroplasty. Clin Orthop Relat Res 282:95–104PubMed Oonishi H, Aono M, Murata N, Kushitani S (1992) Alumina versus polyethylene in total knee arthroplasty. Clin Orthop Relat Res 282:95–104PubMed
32.
go back to reference Oonishi H, Ueno M, Kim S, Iwamoto M, Kyomoto M (2009) Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis. J Arthroplasty 24:374–382PubMedCrossRef Oonishi H, Ueno M, Kim S, Iwamoto M, Kyomoto M (2009) Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis. J Arthroplasty 24:374–382PubMedCrossRef
33.
34.
go back to reference Pritchett JW (2011) Patients prefer a bicruciate-retaining or the medial pivot total knee prosthesis. J Arthroplasty 26:224–228PubMedCrossRef Pritchett JW (2011) Patients prefer a bicruciate-retaining or the medial pivot total knee prosthesis. J Arthroplasty 26:224–228PubMedCrossRef
35.
go back to reference Ranawat C, Luessenhop C, Rodriguez J (1997) The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am 79:342–348PubMed Ranawat C, Luessenhop C, Rodriguez J (1997) The press-fit condylar modular total knee system. Four-to-six-year results with a posterior-cruciate-substituting design. J Bone Joint Surg Am 79:342–348PubMed
36.
go back to reference Robertsson O, Bizjajeva S, Fenstad AM, Furnes O, Lidgren L, Mehnert F, Odgaard A, Pedersen AB, Havelin LI (2010) Knee arthroplasty in Denmark, Norway and Sweden. Acta Orthop 81:82–89PubMedCrossRef Robertsson O, Bizjajeva S, Fenstad AM, Furnes O, Lidgren L, Mehnert F, Odgaard A, Pedersen AB, Havelin LI (2010) Knee arthroplasty in Denmark, Norway and Sweden. Acta Orthop 81:82–89PubMedCrossRef
37.
go back to reference Saari T, Uvehammer J, Carlsson L, Herberts P, Regnér L, Kärrholm J (2003) Kinematics of three variations of the Freeman-Samuelson total knee prosthesis. Clin Orthop Relat Res 410:235–247PubMedCrossRef Saari T, Uvehammer J, Carlsson L, Herberts P, Regnér L, Kärrholm J (2003) Kinematics of three variations of the Freeman-Samuelson total knee prosthesis. Clin Orthop Relat Res 410:235–247PubMedCrossRef
38.
go back to reference Schmidt R, Komistek R, Blaha J, Penenberg B, Maloney W (2003) Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants. Clin Orthop Relat Res 410:139–147PubMedCrossRef Schmidt R, Komistek R, Blaha J, Penenberg B, Maloney W (2003) Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants. Clin Orthop Relat Res 410:139–147PubMedCrossRef
39.
go back to reference Shakespeare D, Ledger M, Kinzel V (2006) Flexion after total knee replacement. A comparison between the medial pivot knee and a posterior stabilised implant. Knee 13:371–373PubMedCrossRef Shakespeare D, Ledger M, Kinzel V (2006) Flexion after total knee replacement. A comparison between the medial pivot knee and a posterior stabilised implant. Knee 13:371–373PubMedCrossRef
40.
go back to reference Stiehl J, Komistek R, Cloutier J, Dennis D (2000) The cruciate ligaments in total knee arthroplasty: a kinematic analysis of 2 total knee arthroplasties. J Arthroplasty 15:545–550PubMedCrossRef Stiehl J, Komistek R, Cloutier J, Dennis D (2000) The cruciate ligaments in total knee arthroplasty: a kinematic analysis of 2 total knee arthroplasties. J Arthroplasty 15:545–550PubMedCrossRef
41.
go back to reference Ueno M, Nakamura T, Akagi M (2002) Comparison of the wear properties of polyethylene plate in total knee prostheses (TKP) using different femoral component materials. Bioceramics 15:801–804 Ueno M, Nakamura T, Akagi M (2002) Comparison of the wear properties of polyethylene plate in total knee prostheses (TKP) using different femoral component materials. Bioceramics 15:801–804
42.
go back to reference van Duren BH, Pandit H, Beard DJ, Zavatsky AB, Gallagher JA, Thomas NP, Shakespeare DT, Murray DW, Gill HS (2007) How effective are added constraints in improving TKR kinematics? J Biomech 40(Suppl 1):S31–S37PubMedCrossRef van Duren BH, Pandit H, Beard DJ, Zavatsky AB, Gallagher JA, Thomas NP, Shakespeare DT, Murray DW, Gill HS (2007) How effective are added constraints in improving TKR kinematics? J Biomech 40(Suppl 1):S31–S37PubMedCrossRef
43.
go back to reference Victor J, Banks S, Bellemans J (2005) Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study. J Bone Joint Surg Br 87:646–655PubMedCrossRef Victor J, Banks S, Bellemans J (2005) Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study. J Bone Joint Surg Br 87:646–655PubMedCrossRef
44.
go back to reference Yasuda K, Miyagi N, Kaneda K (1993) Low friction total knee arthroplasty with the alumina ceramic condylar prosthesis. Bull Hosp Jt Dis 53:15–21PubMed Yasuda K, Miyagi N, Kaneda K (1993) Low friction total knee arthroplasty with the alumina ceramic condylar prosthesis. Bull Hosp Jt Dis 53:15–21PubMed
Metadata
Title
Mid-term clinical results of alumina medial pivot total knee arthroplasty
Authors
Takahiro Iida
Yukihide Minoda
Yoshinori Kadoya
Yoshio Matsui
Akio Kobayashi
Hiroyoshi Iwaki
Mitsuhiko Ikebuchi
Taku Yoshida
Hiroaki Nakamura
Publication date
01-08-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 8/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1734-3

Other articles of this Issue 8/2012

Knee Surgery, Sports Traumatology, Arthroscopy 8/2012 Go to the issue