Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 2/2009

Open Access 01-02-2009 | Original Article

Early Outcome of TKA with a Medial Pivot Fixed-bearing Prosthesis is Worse than with a PFC Mobile-bearing Prosthesis

Authors: Young-Hoo Kim, MD, Sung-Hwan Yoon, MD, Jun-Shik Kim, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 2/2009

Login to get access

Abstract

Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55–81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2–3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis.
Level of Evidence: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Argenson JN, O’Connor JJ. Polyethylene wear in meniscal knee replacement: a one to nine-year retrieval analysis of the Oxford knee. J Bone Joint Surg Br. 1992;74:228–232.PubMed Argenson JN, O’Connor JJ. Polyethylene wear in meniscal knee replacement: a one to nine-year retrieval analysis of the Oxford knee. J Bone Joint Surg Br. 1992;74:228–232.PubMed
2.
go back to reference Barrack RL, McClure JT, Burak CF, Clohisy JC, Parvizi J, Hozack W. Revision total hip arthroplasty: the patient’s perspective. Clin Orthop Relat Res. 2006;453:173–177.PubMedCrossRef Barrack RL, McClure JT, Burak CF, Clohisy JC, Parvizi J, Hozack W. Revision total hip arthroplasty: the patient’s perspective. Clin Orthop Relat Res. 2006;453:173–177.PubMedCrossRef
3.
go back to reference Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 1986;68:1041–1051.PubMed Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 1986;68:1041–1051.PubMed
4.
go back to reference Buechel FF Sr, Buechel FF Jr, Pappas MJ, D’Alessio J. Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop Relat Res. 2001;388:41–50.PubMedCrossRef Buechel FF Sr, Buechel FF Jr, Pappas MJ, D’Alessio J. Twenty-year evaluation of meniscal bearing and rotating platform knee replacements. Clin Orthop Relat Res. 2001;388:41–50.PubMedCrossRef
5.
go back to reference Bugbee WD, Ammeen DJ, Parks NL, Engh GA. 4- to 10-year results with the anatomic modular total knee. Clin Orthop Relat Res. 1998;348:158–165.PubMedCrossRef Bugbee WD, Ammeen DJ, Parks NL, Engh GA. 4- to 10-year results with the anatomic modular total knee. Clin Orthop Relat Res. 1998;348:158–165.PubMedCrossRef
6.
go back to reference Colizza WA, Insall JN, Scuderi GR. The posterior stabilized total knee prosthesis: assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. J Bone Joint Surg Am. 1995;77:1713–1720.PubMed Colizza WA, Insall JN, Scuderi GR. The posterior stabilized total knee prosthesis: assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. J Bone Joint Surg Am. 1995;77:1713–1720.PubMed
7.
go back to reference Diduch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D. Total knee replacement in young, active patients: long-term follow-up and functional outcome. J Bone Joint Surg Am. 1997;79:575–582.PubMed Diduch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D. Total knee replacement in young, active patients: long-term follow-up and functional outcome. J Bone Joint Surg Am. 1997;79:575–582.PubMed
8.
go back to reference Engh GA. Failure of the polyethylene bearing surface of a total knee replacement within four years: a case report. J Bone Joint Surg Am. 1988;70:1093–1096.PubMed Engh GA. Failure of the polyethylene bearing surface of a total knee replacement within four years: a case report. J Bone Joint Surg Am. 1988;70:1093–1096.PubMed
9.
go back to reference Hanssen AD, Rand JA. Evaluation and treatment of infection at the site of a total hip or knee arthroplasty. Instr Course Lect. 1999;48:111–122.PubMed Hanssen AD, Rand JA. Evaluation and treatment of infection at the site of a total hip or knee arthroplasty. Instr Course Lect. 1999;48:111–122.PubMed
10.
go back to reference Hill C, Flamant R, Mazas F, Evrard J. Prophylactic cefazolin versus placebo in total hip replacement: report of a multicentre double blind randomised trial. Lancet. 1981;1:795–796.PubMedCrossRef Hill C, Flamant R, Mazas F, Evrard J. Prophylactic cefazolin versus placebo in total hip replacement: report of a multicentre double blind randomised trial. Lancet. 1981;1:795–796.PubMedCrossRef
11.
go back to reference Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed
12.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14.PubMed Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14.PubMed
13.
go back to reference Insall JN, Hood RW, Flawn LB, Sullivan DJ. The total condylar knee prosthesis in gonarthrosis: a five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Joint Surg Am. 1983;65:619–628.PubMed Insall JN, Hood RW, Flawn LB, Sullivan DJ. The total condylar knee prosthesis in gonarthrosis: a five to nine-year follow-up of the first one hundred consecutive replacements. J Bone Joint Surg Am. 1983;65:619–628.PubMed
14.
go back to reference Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am. 1976;58:754–765.PubMed Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am. 1976;58:754–765.PubMed
15.
go back to reference Kim YH, Kim DY, Kim JS. Simultaneous mobile- and fixed-bearing total knee replacement in the same patients: a prospective comparison of mid-term outcomes using a similar design of prosthesis. J Bone Joint Surg Br. 2007;89:904–910.PubMed Kim YH, Kim DY, Kim JS. Simultaneous mobile- and fixed-bearing total knee replacement in the same patients: a prospective comparison of mid-term outcomes using a similar design of prosthesis. J Bone Joint Surg Br. 2007;89:904–910.PubMed
16.
go back to reference Kim YH, Kook HK, Kim JS. Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop Relat Res. 2001;392:101–115.PubMedCrossRef Kim YH, Kook HK, Kim JS. Comparison of fixed-bearing and mobile-bearing total knee arthroplasties. Clin Orthop Relat Res. 2001;392:101–115.PubMedCrossRef
17.
go back to reference Menchetti PP, Walker PS. Mechanical evaluation of mobile bearing knees. Am J Knee Surg. 1997;10:73–81, discussion 81–82.PubMed Menchetti PP, Walker PS. Mechanical evaluation of mobile bearing knees. Am J Knee Surg. 1997;10:73–81, discussion 81–82.PubMed
18.
go back to reference O’Connor JJ, Goodfellow JW. Theory and practice of meniscal knee replacement: designing against wear. Proc Inst Mech Eng [H]. 1996;210:217–222. O’Connor JJ, Goodfellow JW. Theory and practice of meniscal knee replacement: designing against wear. Proc Inst Mech Eng [H]. 1996;210:217–222.
19.
go back to reference Peersman G, Laskin R, Davis J, Peterson M. Infection in total knee replacement: a retrospective review of 6489 total knee replacements. Clin Orthop Relat Res. 2001;392:15–23.PubMedCrossRef Peersman G, Laskin R, Davis J, Peterson M. Infection in total knee replacement: a retrospective review of 6489 total knee replacements. Clin Orthop Relat Res. 2001;392:15–23.PubMedCrossRef
20.
go back to reference Schai PA, Thornhill TS, Scott RD. Total knee arthroplasty with the PFC system: results at a minimum of ten years and survivorship analysis. J Bone Joint Surg Br. 1998;80:850–858.PubMedCrossRef Schai PA, Thornhill TS, Scott RD. Total knee arthroplasty with the PFC system: results at a minimum of ten years and survivorship analysis. J Bone Joint Surg Br. 1998;80:850–858.PubMedCrossRef
21.
go back to reference Schmidt R, Komistek RD, Blaha JD, Penenberg BL, Maloney WJ. Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants. Clin Orthop Relat Res. 2003;410:139–147.PubMedCrossRef Schmidt R, Komistek RD, Blaha JD, Penenberg BL, Maloney WJ. Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants. Clin Orthop Relat Res. 2003;410:139–147.PubMedCrossRef
22.
go back to reference Shakespeare D, Kinzel V, Ledger M. Achieving ligament stability and correct rotational alignment of the femur in knee arthroplasty: a study using the Medial Pivot knee. Knee. 2005;12:419–423.PubMedCrossRef Shakespeare D, Kinzel V, Ledger M. Achieving ligament stability and correct rotational alignment of the femur in knee arthroplasty: a study using the Medial Pivot knee. Knee. 2005;12:419–423.PubMedCrossRef
23.
go back to reference Stern SH, Insall JN. Posterior stabilized prosthesis: results after follow-up of nine to twelve years. J Bone Joint Surg Am. 1992;74:980–986.PubMed Stern SH, Insall JN. Posterior stabilized prosthesis: results after follow-up of nine to twelve years. J Bone Joint Surg Am. 1992;74:980–986.PubMed
24.
go back to reference Stiehl JB. Mobile bearings in total knee arthroplasty. In: Scott WN, ed. Insall & Scott Surgery of Knee. Vol 2. Philadelphia, PA: Churchill Livingstone Elsevier; 2006:1588–1573. Stiehl JB. Mobile bearings in total knee arthroplasty. In: Scott WN, ed. Insall & Scott Surgery of Knee. Vol 2. Philadelphia, PA: Churchill Livingstone Elsevier; 2006:1588–1573.
25.
go back to reference Wohlrab D, Ditl J, Herrschelmann R, Schietsch U, Hein W, Hube R. [Does the NexGen LPS flex mobile knee prosthesis offer advantages compared to the NexGen LPS?: a comparison of clinical and radiographic results][in German]. Z Orthop Ihre Grenzgeb. 2005;143:567–572.PubMedCrossRef Wohlrab D, Ditl J, Herrschelmann R, Schietsch U, Hein W, Hube R. [Does the NexGen LPS flex mobile knee prosthesis offer advantages compared to the NexGen LPS?: a comparison of clinical and radiographic results][in German]. Z Orthop Ihre Grenzgeb. 2005;143:567–572.PubMedCrossRef
26.
go back to reference Woolson ST, Northrop GD. Mobile vs fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty. 2004;19:135–140.PubMedCrossRef Woolson ST, Northrop GD. Mobile vs fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty. 2004;19:135–140.PubMedCrossRef
27.
go back to reference Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop Relat Res. 1986;205:67–74.PubMed Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop Relat Res. 1986;205:67–74.PubMed
Metadata
Title
Early Outcome of TKA with a Medial Pivot Fixed-bearing Prosthesis is Worse than with a PFC Mobile-bearing Prosthesis
Authors
Young-Hoo Kim, MD
Sung-Hwan Yoon, MD
Jun-Shik Kim, MD
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0221-8

Other articles of this Issue 2/2009

Clinical Orthopaedics and Related Research® 2/2009 Go to the issue

Symposium: Clinical Risk and Judicial Reasoning

An Introduction to Medical Malpractice in the United States

Orthopaedic • Radiology • Pathology Conference

Low Backache in a 70-year-old Woman