Skip to main content
Top

01-04-2024 | Original Article

Mechanical Effects of Medical Device Attachment to Human Tympanic Membrane

Authors: Arash Ebrahimian, Hossein Mohammadi, Nima Maftoon

Published in: Journal of the Association for Research in Otolaryngology

Login to get access

Abstract

Purpose

Several treatment methods for hearing disorders rely on attaching medical devices to the tympanic membrane. This study aims to systematically analyze the effects of the material and geometrical properties and location of the medical devices attached to the tympanic membrane on middle-ear vibrations.

Methods

A finite-element model of the human middle ear was employed to simulate the effects of attachment of medical devices. Various types of material and geometrical properties, locations, and modeling scenarios were investigated for the medical device.

Results

The attachment of the device magnifies the effects of anti-resonances of the middle ear. Additionally, the variations of the material properties of the device significantly alter the middle-ear resonance frequency while changes in the umbo and stapes footplate motions are negligible at frequencies above 5 kHz. Furthermore, modeling the device as a point mass cannot accurately represent the implanted middle-ear behavior. The variations of the diameter and height of the medical device have negligible effects on the middle-ear vibrations at frequencies below 200 Hz but can have considerable impacts at higher frequencies. The effects of changing the device height were negligible at frequencies above 2 kHz. We also discuss the effects of medical device attachment on the vibration patterns of the tympanic membrane as well as the impacts of the variations of the location of the device on the stapes footplate responses.

Conclusion

The findings of our study aid the development and optimization of new therapeutic devices, attached to the tympanic membrane, to have the least adverse effects on middle-ear vibrations.
Appendix
Available only for authorised users
Footnotes
1
The coefficient of variation is defined as the percentage of the standard deviation divided by the mean.
 
Literature
10.
go back to reference Frear DL, Guan X, Stieger C, Rosowski JJ, Nakajima HH (2018) Impedances of the inner and middle ear estimated from intracochlear sound pressures in normal human temporal bones. Hear Res 367:17–31CrossRefPubMedPubMedCentral Frear DL, Guan X, Stieger C, Rosowski JJ, Nakajima HH (2018) Impedances of the inner and middle ear estimated from intracochlear sound pressures in normal human temporal bones. Hear Res 367:17–31CrossRefPubMedPubMedCentral
11.
go back to reference Xue L, Liu H, Wang W, Yang J, Zhao Y, Huang X (2020) The role of third windows on human sound transmission of forward and reverse stimulations: a lumped-parameter approach. J Acoust Soc Am 147:1478–1490CrossRefPubMed Xue L, Liu H, Wang W, Yang J, Zhao Y, Huang X (2020) The role of third windows on human sound transmission of forward and reverse stimulations: a lumped-parameter approach. J Acoust Soc Am 147:1478–1490CrossRefPubMed
12.
go back to reference Bernhard H, Stieger C, Perriard Y (2010) Design of a semi-implantable hearing device for direct acoustic cochlear stimulation. IEEE Trans Biomed Eng 58:420–428CrossRefPubMed Bernhard H, Stieger C, Perriard Y (2010) Design of a semi-implantable hearing device for direct acoustic cochlear stimulation. IEEE Trans Biomed Eng 58:420–428CrossRefPubMed
18.
go back to reference Ebrahimian A, Maftoon N (2021) Stochastic finite element modelling of human middle-ear. CMBES Proceedings 44 Ebrahimian A, Maftoon N (2021) Stochastic finite element modelling of human middle-ear. CMBES Proceedings 44
24.
go back to reference Vlaming MSMG, Feenstra L (1986) Studies on the mechanics of the normal human middle ear. 11(5):11 Vlaming MSMG, Feenstra L (1986) Studies on the mechanics of the normal human middle ear. 11(5):11
29.
go back to reference Armani D, Liu C, Aluru N (1999) Re-configurable fluid circuits by PDMS elastomer micromachining. In: Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291). IEEE, Orlando, FL, USA, pp 222–227 Armani D, Liu C, Aluru N (1999) Re-configurable fluid circuits by PDMS elastomer micromachining. In: Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291). IEEE, Orlando, FL, USA, pp 222–227
33.
go back to reference Goode RL, Killion M, Nakamura K, Nishihara S (1994) New knowledge about the function of the human middle ear: development of an improved analog model. Am J Otol 15:145–154PubMed Goode RL, Killion M, Nakamura K, Nishihara S (1994) New knowledge about the function of the human middle ear: development of an improved analog model. Am J Otol 15:145–154PubMed
Metadata
Title
Mechanical Effects of Medical Device Attachment to Human Tympanic Membrane
Authors
Arash Ebrahimian
Hossein Mohammadi
Nima Maftoon
Publication date
01-04-2024
Publisher
Springer US
Published in
Journal of the Association for Research in Otolaryngology
Print ISSN: 1525-3961
Electronic ISSN: 1438-7573
DOI
https://doi.org/10.1007/s10162-024-00942-5