Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2013

Open Access 01-12-2013 | Research article

Measures and procedures utilized to determine the added value of microprocessor-controlled prosthetic knee joints: a systematic review

Authors: Patrick JR Theeven, Bea Hemmen, Peter RG Brink, Rob JEM Smeets, Henk AM Seelen

Published in: BMC Musculoskeletal Disorders | Issue 1/2013

Login to get access

Abstract

Background

The effectiveness of microprocessor-controlled prosthetic knee joints (MPKs) has been assessed using a variety of outcome measures in a variety of health and health-related domains. However, if the patient is to receive a prosthetic knee joint that enables him to function optimally in daily life, it is vital that the clinician has adequate information about the effects of that particular component on all aspects of persons’ functioning. Especially information concerning activities and participation is of high importance, as this component of functioning closely describes the person’s ability to function with the prosthesis in daily life. The present study aimed to review the outcome measures that have been utilized to assess the effects of microprocessor-controlled prosthetic knee joints (MPK), in comparison with mechanically controlled prosthetic knee joints, and aimed to classify these measures according to the components and categories of functioning defined by the International Classification of Functioning, Disability and Health (ICF). Subsequently, the gaps in the scientific evidence regarding the effectiveness of MPKs were determined.

Methods

A systematic literature search in 6 databases (i.e. PubMed, CINAHL, Cochrane Library, Embase, Medline and PsychInfo) identified scientific studies that compared the effects of using MPKs with mechanically controlled prosthetic knee joints on persons’ functioning. The outcome measures that have been utilized in those studies were extracted and categorized according to the ICF framework. Also, a descriptive analysis regarding all studies has been performed.

Results

A total of 37 studies and 72 outcome measures have been identified. The majority (67%) of the outcome measures that described the effects of using an MPK on persons’ actual performance with the prosthesis covered the ICF body functions component. Only 31% of the measures on persons’ actual performance investigated how an MPK may affect performance in daily life. Research also typically focused on young, fit and active persons.

Conclusions

Scientifically valid evidence regarding the performance of persons with an MPK in everyday life is limited. Future research should specifically focus on activities and participation to increase the understanding of the possible functional added value of MPKs.
Appendix
Available only for authorised users
Literature
2.
go back to reference World Health Organisation: International Classification of Functioning, Disability and Health: ICF. 2001, Geneva: World Health Organisation World Health Organisation: International Classification of Functioning, Disability and Health: ICF. 2001, Geneva: World Health Organisation
3.
go back to reference Centers for Medicare and Medicaid Services. U.S. Department of Health and Human Services: HCFA Common Procedure Coding System (HCPCS). 2001, Springfield (VA): U.S. Department of Commerce, National Technical Information Service Centers for Medicare and Medicaid Services. U.S. Department of Health and Human Services: HCFA Common Procedure Coding System (HCPCS). 2001, Springfield (VA): U.S. Department of Commerce, National Technical Information Service
5.
go back to reference van Tulder M, Furlan A, Bombardier C, Bouter L: Updated method guidelines for systematic reviews in the cochrane collaboration back review group. Spine (Phila Pa 1976). 2003, 28 (12): 1290-1299. van Tulder M, Furlan A, Bombardier C, Bouter L: Updated method guidelines for systematic reviews in the cochrane collaboration back review group. Spine (Phila Pa 1976). 2003, 28 (12): 1290-1299.
6.
go back to reference van Tulder MW, Assendelft WJ, Koes BW, Bouter LM: Method guidelines for systematic reviews in the Cochrane Collaboration Back Review Group for Spinal Disorders. Spine (Phila Pa 1976). 1997, 22 (20): 2323-2330. 10.1097/00007632-199710150-00001.CrossRef van Tulder MW, Assendelft WJ, Koes BW, Bouter LM: Method guidelines for systematic reviews in the Cochrane Collaboration Back Review Group for Spinal Disorders. Spine (Phila Pa 1976). 1997, 22 (20): 2323-2330. 10.1097/00007632-199710150-00001.CrossRef
7.
go back to reference Kirker S, Keymer S, Talbot J, Lachmann S: An assessment of the intelligent knee prosthesis. Clin Rehabil. 1996, 10 (3): 267-273. 10.1177/026921559601000314.CrossRef Kirker S, Keymer S, Talbot J, Lachmann S: An assessment of the intelligent knee prosthesis. Clin Rehabil. 1996, 10 (3): 267-273. 10.1177/026921559601000314.CrossRef
8.
go back to reference Taylor MB, Clark E, Offord EA, Baxter C: A comparison of energy expenditure by a high level trans-femoral amputee using the Intelligent Prosthesis and conventionally damped prosthetic limbs. Prosthet Orthot Int. 1996, 20 (2): 116-121.PubMed Taylor MB, Clark E, Offord EA, Baxter C: A comparison of energy expenditure by a high level trans-femoral amputee using the Intelligent Prosthesis and conventionally damped prosthetic limbs. Prosthet Orthot Int. 1996, 20 (2): 116-121.PubMed
9.
go back to reference Buckley JG, Spence WD, Solomonidis SE: Energy cost of walking: comparison of “intelligent prosthesis” with conventional mechanism. Arch Phys Med Rehabil. 1997, 78 (3): 330-333. 10.1016/S0003-9993(97)90044-7.CrossRefPubMed Buckley JG, Spence WD, Solomonidis SE: Energy cost of walking: comparison of “intelligent prosthesis” with conventional mechanism. Arch Phys Med Rehabil. 1997, 78 (3): 330-333. 10.1016/S0003-9993(97)90044-7.CrossRefPubMed
10.
go back to reference Datta D, Howitt J: Conventional versus microchip controlled pneumatic swing phase control for trans-femoral amputees: user’s verdict. Prosthet Orthot Int. 1998, 22 (2): 129-135.PubMed Datta D, Howitt J: Conventional versus microchip controlled pneumatic swing phase control for trans-femoral amputees: user’s verdict. Prosthet Orthot Int. 1998, 22 (2): 129-135.PubMed
11.
go back to reference Heller BW, Datta D, Howitt J: A pilot study comparing the cognitive demand of walking for transfemoral amputees using the Intelligent Prosthesis with that using conventionally damped knees. Clin Rehabil. 2000, 14 (5): 518-522. 10.1191/0269215500cr345oa.CrossRefPubMed Heller BW, Datta D, Howitt J: A pilot study comparing the cognitive demand of walking for transfemoral amputees using the Intelligent Prosthesis with that using conventionally damped knees. Clin Rehabil. 2000, 14 (5): 518-522. 10.1191/0269215500cr345oa.CrossRefPubMed
12.
go back to reference Stinus H: Biomechanics and evaluation of the microprocessor-controlled C-leg. [German] Biomechanik und beurteilung des exoprothesenkniegelenkes C-leg. Z Orthop Ihre Grenzgeb. 2000, 138 (3): 278-282. 10.1055/s-2000-10149.CrossRefPubMed Stinus H: Biomechanics and evaluation of the microprocessor-controlled C-leg. [German] Biomechanik und beurteilung des exoprothesenkniegelenkes C-leg. Z Orthop Ihre Grenzgeb. 2000, 138 (3): 278-282. 10.1055/s-2000-10149.CrossRefPubMed
13.
go back to reference Schmalz T, Blumentritt S, Jarasch R: Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components. Gait Posture. 2002, 16 (3): 255-263. 10.1016/S0966-6362(02)00008-5.CrossRefPubMed Schmalz T, Blumentritt S, Jarasch R: Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components. Gait Posture. 2002, 16 (3): 255-263. 10.1016/S0966-6362(02)00008-5.CrossRefPubMed
14.
go back to reference Perry J, Burnfield JM, Newsam CJ, Conley P: Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses. Arch Phys Med Rehabil. 2004, 85 (10): 1711-1717. 10.1016/j.apmr.2004.02.028.CrossRefPubMed Perry J, Burnfield JM, Newsam CJ, Conley P: Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses. Arch Phys Med Rehabil. 2004, 85 (10): 1711-1717. 10.1016/j.apmr.2004.02.028.CrossRefPubMed
15.
go back to reference Yokogushi K, Narita H, Uchiyama E, Chiba S, Nosaka T, Yamakoshi KI: Biomechanical and clinical evaluation of a newly designed polycentric knee of transfemoral prosthesis. J Rehabil Res Dev. 2004, 41 (5): 675-681. 10.1682/JRRD.2003.05.0076.CrossRefPubMed Yokogushi K, Narita H, Uchiyama E, Chiba S, Nosaka T, Yamakoshi KI: Biomechanical and clinical evaluation of a newly designed polycentric knee of transfemoral prosthesis. J Rehabil Res Dev. 2004, 41 (5): 675-681. 10.1682/JRRD.2003.05.0076.CrossRefPubMed
16.
go back to reference Datta D, Heller B, Howitt J: A comparative evaluation of oxygen consumption and gait pattern in amputees using Intelligent Prostheses and conventionally damped knee swing-phase control. Clin Rehabil. 2005, 19 (4): 398-403. 10.1191/0269215505cr805oa.CrossRefPubMed Datta D, Heller B, Howitt J: A comparative evaluation of oxygen consumption and gait pattern in amputees using Intelligent Prostheses and conventionally damped knee swing-phase control. Clin Rehabil. 2005, 19 (4): 398-403. 10.1191/0269215505cr805oa.CrossRefPubMed
17.
go back to reference Johansson JL, Sherrill DM, Riley PO, Bonato P, Herr H: A clinical comparison of variable-damping and mechanically passive prosthetic knee devices. Am J Phys Med Rehabil. 2005, 84 (8): 563-575. 10.1097/01.phm.0000174665.74933.0b.CrossRefPubMed Johansson JL, Sherrill DM, Riley PO, Bonato P, Herr H: A clinical comparison of variable-damping and mechanically passive prosthetic knee devices. Am J Phys Med Rehabil. 2005, 84 (8): 563-575. 10.1097/01.phm.0000174665.74933.0b.CrossRefPubMed
18.
go back to reference Wetz HH, Hafkemeyer U, Drerup B: [The influence of the C-leg knee-shin system from the Otto Bock Company in the care of above-knee amputees. A clinical-biomechanical study to define indications]. Orthopade. 2005, 34 (4): 298, 300-314, 316-299- Wetz HH, Hafkemeyer U, Drerup B: [The influence of the C-leg knee-shin system from the Otto Bock Company in the care of above-knee amputees. A clinical-biomechanical study to define indications]. Orthopade. 2005, 34 (4): 298, 300-314, 316-299-
19.
go back to reference Klute GK, Berge JS, Orendurff MS, Williams RM, Czerniecki JM: Prosthetic intervention effects on activity of lower-extremity amputees. Arch Phys Med Rehabil. 2006, 87 (5): 717-722. 10.1016/j.apmr.2006.02.007.CrossRefPubMed Klute GK, Berge JS, Orendurff MS, Williams RM, Czerniecki JM: Prosthetic intervention effects on activity of lower-extremity amputees. Arch Phys Med Rehabil. 2006, 87 (5): 717-722. 10.1016/j.apmr.2006.02.007.CrossRefPubMed
20.
go back to reference Orendurff MS, Segal AD, Klute GK, McDowell ML, Pecoraro JA, Czerniecki JM: Gait efficiency using the C-Leg. J Rehabil Res Dev. 2006, 43 (2): 239-246. 10.1682/JRRD.2005.06.0095.CrossRefPubMed Orendurff MS, Segal AD, Klute GK, McDowell ML, Pecoraro JA, Czerniecki JM: Gait efficiency using the C-Leg. J Rehabil Res Dev. 2006, 43 (2): 239-246. 10.1682/JRRD.2005.06.0095.CrossRefPubMed
21.
go back to reference Segal AD, Orendurff MS, Klute GK, McDowell ML, Pecoraro JA, Shofer J, Czerniecki JM: Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees. J Rehabil Res Dev. 2006, 43 (7): 857-870. 10.1682/JRRD.2005.09.0147.CrossRefPubMed Segal AD, Orendurff MS, Klute GK, McDowell ML, Pecoraro JA, Shofer J, Czerniecki JM: Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees. J Rehabil Res Dev. 2006, 43 (7): 857-870. 10.1682/JRRD.2005.09.0147.CrossRefPubMed
22.
go back to reference Williams RM, Turner AP, Orendurff M, Segal AD, Klute GK, Pecoraro J, Czerniecki J: Does having a computerized prosthetic knee influence cognitive performance during amputee walking?. Arch Phys Med Rehabil. 2006, 87 (7): 989-994. 10.1016/j.apmr.2006.03.006.CrossRefPubMed Williams RM, Turner AP, Orendurff M, Segal AD, Klute GK, Pecoraro J, Czerniecki J: Does having a computerized prosthetic knee influence cognitive performance during amputee walking?. Arch Phys Med Rehabil. 2006, 87 (7): 989-994. 10.1016/j.apmr.2006.03.006.CrossRefPubMed
23.
go back to reference Bunce DJ, Breakey JW: The impact of C-Leg on the physical and psychological adjustment to transfemoral amputation. J Prosthet Orthot. 2007, 19 (1): 7-14. 10.1097/JPO.0b013e31802d41a4.CrossRef Bunce DJ, Breakey JW: The impact of C-Leg on the physical and psychological adjustment to transfemoral amputation. J Prosthet Orthot. 2007, 19 (1): 7-14. 10.1097/JPO.0b013e31802d41a4.CrossRef
24.
go back to reference Chin T, Maeda Y, Sawamura S, Oyabu H, Nagakura Y, Takase I, Machida K: Successful prosthetic fitting of elderly trans-femoral amputees with Intelligent Prosthesis (IP): a clinical pilot study. Prosthet Orthot Int. 2007, 31 (3): 271-276. 10.1080/03093640601040152.CrossRefPubMed Chin T, Maeda Y, Sawamura S, Oyabu H, Nagakura Y, Takase I, Machida K: Successful prosthetic fitting of elderly trans-femoral amputees with Intelligent Prosthesis (IP): a clinical pilot study. Prosthet Orthot Int. 2007, 31 (3): 271-276. 10.1080/03093640601040152.CrossRefPubMed
25.
go back to reference Hafner BJ, Willingham LL, Buell NC, Allyn KJ, Smith DG: Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee. Arch Phys Med Rehabil. 2007, 88 (2): 207-217. 10.1016/j.apmr.2006.10.030.CrossRefPubMed Hafner BJ, Willingham LL, Buell NC, Allyn KJ, Smith DG: Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee. Arch Phys Med Rehabil. 2007, 88 (2): 207-217. 10.1016/j.apmr.2006.10.030.CrossRefPubMed
26.
go back to reference Kaufman KR, Levine JA, Brey RH, Iverson BK, McCrady SK, Padgett DJ, Joyner MJ: Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees. Gait Posture. 2007, 26 (4): 489-493. 10.1016/j.gaitpost.2007.07.011.CrossRefPubMed Kaufman KR, Levine JA, Brey RH, Iverson BK, McCrady SK, Padgett DJ, Joyner MJ: Gait and balance of transfemoral amputees using passive mechanical and microprocessor-controlled prosthetic knees. Gait Posture. 2007, 26 (4): 489-493. 10.1016/j.gaitpost.2007.07.011.CrossRefPubMed
27.
go back to reference Seymour R, Engbretson B, Kott K, Ordway N, Brooks G, Crannell J, Hickernell E, Wheeler K: Comparison between the C-leg microprocessor-controlled prosthetic knee and non-microprocessor control prosthetic knees: a preliminary study of energy expenditure, obstacle course performance, and quality of life survey. Prosthet Orthot Int. 2007, 31 (1): 51-61. 10.1080/03093640600982255.CrossRefPubMed Seymour R, Engbretson B, Kott K, Ordway N, Brooks G, Crannell J, Hickernell E, Wheeler K: Comparison between the C-leg microprocessor-controlled prosthetic knee and non-microprocessor control prosthetic knees: a preliminary study of energy expenditure, obstacle course performance, and quality of life survey. Prosthet Orthot Int. 2007, 31 (1): 51-61. 10.1080/03093640600982255.CrossRefPubMed
28.
go back to reference Stevens PM, Carson R: Case report: Using the Activities-Specific Balance Confidence Scale to quantify the impact of prosthetic knee choice on balance confidence. J Prosthet Orthot. 2007, 19 (4): 114-116. 10.1097/JPO.0b013e31815711a3.CrossRef Stevens PM, Carson R: Case report: Using the Activities-Specific Balance Confidence Scale to quantify the impact of prosthetic knee choice on balance confidence. J Prosthet Orthot. 2007, 19 (4): 114-116. 10.1097/JPO.0b013e31815711a3.CrossRef
29.
go back to reference Jepson F, Datta D, Harris I, Heller B, Howitt J, McLean J: A comparative evaluation of the Adaptive knee and Catech knee joints: a preliminary study. Prosthet Orthot Int. 2008, 32 (1): 84-92. 10.1080/03093640701676376.CrossRefPubMed Jepson F, Datta D, Harris I, Heller B, Howitt J, McLean J: A comparative evaluation of the Adaptive knee and Catech knee joints: a preliminary study. Prosthet Orthot Int. 2008, 32 (1): 84-92. 10.1080/03093640701676376.CrossRefPubMed
30.
go back to reference Kahle JT, Highsmith MJ, Hubbard SL: Comparison of nonmicroprocessor knee mechanism versus C-Leg on Prosthesis Evaluation Questionnaire, stumbles, falls, walking tests, stair descent, and knee preference. J Rehabil Res Dev. 2008, 45 (1): 1-14. 10.1682/JRRD.2007.04.0054.CrossRefPubMed Kahle JT, Highsmith MJ, Hubbard SL: Comparison of nonmicroprocessor knee mechanism versus C-Leg on Prosthesis Evaluation Questionnaire, stumbles, falls, walking tests, stair descent, and knee preference. J Rehabil Res Dev. 2008, 45 (1): 1-14. 10.1682/JRRD.2007.04.0054.CrossRefPubMed
31.
go back to reference Kaufman KR, Levine JA, Brey RH, McCrady SK, Padgett DJ, Joyner MJ: Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees. Arch Phys Med Rehabil. 2008, 89 (7): 1380-1385. 10.1016/j.apmr.2007.11.053.CrossRefPubMedPubMedCentral Kaufman KR, Levine JA, Brey RH, McCrady SK, Padgett DJ, Joyner MJ: Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees. Arch Phys Med Rehabil. 2008, 89 (7): 1380-1385. 10.1016/j.apmr.2007.11.053.CrossRefPubMedPubMedCentral
32.
go back to reference Berry D, Olson MD, Larntz K: Perceived stability, function, and satisfaction among transfemoral amputees using microprocessor and nonmicroprocessor controlled prosthetic knees: a multicentre survey. J Prosthet Orthot. 2009, 21: 32-42. 10.1097/JPO.0b013e318195b1d1.CrossRef Berry D, Olson MD, Larntz K: Perceived stability, function, and satisfaction among transfemoral amputees using microprocessor and nonmicroprocessor controlled prosthetic knees: a multicentre survey. J Prosthet Orthot. 2009, 21: 32-42. 10.1097/JPO.0b013e318195b1d1.CrossRef
33.
go back to reference Blumentritt S, Schmalz T, Jarasch R: The safety of C-leg: biomechanical tests. J Prosthet Orthot. 2009, 21: 2-15. 10.1097/JPO.0b013e318192e96a.CrossRef Blumentritt S, Schmalz T, Jarasch R: The safety of C-leg: biomechanical tests. J Prosthet Orthot. 2009, 21: 2-15. 10.1097/JPO.0b013e318192e96a.CrossRef
34.
go back to reference Hafner BJ, Smith DG: Differences in function and safety between Medicare Functional Classification Level-2 and -3 transfemoral amputees and influence of prosthetic knee joint control. J Rehabil Res Dev. 2009, 46 (3): 417-433. 10.1682/JRRD.2008.01.0007.CrossRefPubMed Hafner BJ, Smith DG: Differences in function and safety between Medicare Functional Classification Level-2 and -3 transfemoral amputees and influence of prosthetic knee joint control. J Rehabil Res Dev. 2009, 46 (3): 417-433. 10.1682/JRRD.2008.01.0007.CrossRefPubMed
35.
go back to reference Mâaref K, Martinet N, Grumillier C, Ghannouchi S, Andre JM, Paysant J: Kinematics in the terminal swing phase of unilateral transfemoral amputees: microprocessor-controlled versus swing-phase control prosthetic knees. Arch Phys Med Rehabil. 2010, 91 (6): 919-925. 10.1016/j.apmr.2010.01.025.CrossRefPubMed Mâaref K, Martinet N, Grumillier C, Ghannouchi S, Andre JM, Paysant J: Kinematics in the terminal swing phase of unilateral transfemoral amputees: microprocessor-controlled versus swing-phase control prosthetic knees. Arch Phys Med Rehabil. 2010, 91 (6): 919-925. 10.1016/j.apmr.2010.01.025.CrossRefPubMed
36.
go back to reference Petersen AO, Comins J, Alkjaer T: Assessment of gait symmetry in transfemoral amputees using C-leg compared with 3R60 prosthetic knees. J Prosthet Orthot. 2010, 22: 106-112. 10.1097/JPO.0b013e3181ccc986.CrossRef Petersen AO, Comins J, Alkjaer T: Assessment of gait symmetry in transfemoral amputees using C-leg compared with 3R60 prosthetic knees. J Prosthet Orthot. 2010, 22: 106-112. 10.1097/JPO.0b013e3181ccc986.CrossRef
37.
go back to reference Highsmith MJ, Kahle JT, Carey SL, Lura DJ, Dubey RV, Csavina KR, Quillen WS: Kinetic asymmetry in transfemoral amputees while performing sit to stand and stand to sit movements. Gait Posture. 2011, 34 (1): 86-91. 10.1016/j.gaitpost.2011.03.018.CrossRefPubMed Highsmith MJ, Kahle JT, Carey SL, Lura DJ, Dubey RV, Csavina KR, Quillen WS: Kinetic asymmetry in transfemoral amputees while performing sit to stand and stand to sit movements. Gait Posture. 2011, 34 (1): 86-91. 10.1016/j.gaitpost.2011.03.018.CrossRefPubMed
38.
go back to reference Theeven P, Hemmen B, Rings F, Meys G, Brink P, Smeets R, Seelen H: Functional added value of microprocessor-controlled knee joints in daily life performance of Medicare Functional Classification Level-2 amputees. J Rehabil Med. 2011,  : 906-915. Theeven P, Hemmen B, Rings F, Meys G, Brink P, Smeets R, Seelen H: Functional added value of microprocessor-controlled knee joints in daily life performance of Medicare Functional Classification Level-2 amputees. J Rehabil Med. 2011,  : 906-915.
39.
go back to reference Burnfield JM, Eberly VJ, Gronely JK, Perry J, Yule WJ, Mulroy SJ: Impact of stance phase microprocessor-controlled knee prosthesis on ramp negotiation and community walking function in K2 level transfemoral amputees. Prosthet Orthot Int. 2012, 36 (1): 95-104. 10.1177/0309364611431611.CrossRefPubMed Burnfield JM, Eberly VJ, Gronely JK, Perry J, Yule WJ, Mulroy SJ: Impact of stance phase microprocessor-controlled knee prosthesis on ramp negotiation and community walking function in K2 level transfemoral amputees. Prosthet Orthot Int. 2012, 36 (1): 95-104. 10.1177/0309364611431611.CrossRefPubMed
40.
go back to reference Kaufman KR, Frittoli S, Frigo CA: Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees. Clin Biomech (Bristol, Avon). 2012, 27 (5): 460-465. 10.1016/j.clinbiomech.2011.11.011.CrossRef Kaufman KR, Frittoli S, Frigo CA: Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees. Clin Biomech (Bristol, Avon). 2012, 27 (5): 460-465. 10.1016/j.clinbiomech.2011.11.011.CrossRef
41.
go back to reference Schaarschmidt M, Lipfert SW, Meier-Gratz C, Scholle HC, Seyfarth A: Functional gait asymmetry of unilateral transfemoral amputees. Hum Mov Sci. 2012, 31 (4): 907-917. 10.1016/j.humov.2011.09.004.CrossRefPubMed Schaarschmidt M, Lipfert SW, Meier-Gratz C, Scholle HC, Seyfarth A: Functional gait asymmetry of unilateral transfemoral amputees. Hum Mov Sci. 2012, 31 (4): 907-917. 10.1016/j.humov.2011.09.004.CrossRefPubMed
42.
go back to reference Theeven PJ, Hemmen B, Geers RP, Smeets RJ, Brink PR, Seelen HA: Influence of advanced prosthetic knee joints on perceived performance and everyday life activity level of low-functional persons with a transfemoral amputation or knee disarticulation. J Rehabil Med. 2012, 44 (5): 454-461. 10.2340/16501977-0969.CrossRefPubMed Theeven PJ, Hemmen B, Geers RP, Smeets RJ, Brink PR, Seelen HA: Influence of advanced prosthetic knee joints on perceived performance and everyday life activity level of low-functional persons with a transfemoral amputation or knee disarticulation. J Rehabil Med. 2012, 44 (5): 454-461. 10.2340/16501977-0969.CrossRefPubMed
43.
go back to reference Wong CK, Wilska J, Stern M: Balance, Balance Confidence, and Falls Using Nonmicroprocessor and Microprocessor Knee Prostheses: A Case Study After Vascular Amputation With 12-Month Follow-Up. J Prosthet Orthot (JPO). 2012, 24 (1): 16-18. 10.1097/JPO.0b013e3182435f12.CrossRef Wong CK, Wilska J, Stern M: Balance, Balance Confidence, and Falls Using Nonmicroprocessor and Microprocessor Knee Prostheses: A Case Study After Vascular Amputation With 12-Month Follow-Up. J Prosthet Orthot (JPO). 2012, 24 (1): 16-18. 10.1097/JPO.0b013e3182435f12.CrossRef
44.
go back to reference Phillips B, Zhao H: Predictors of assistive technology abandonment. Assist Technol. 1993, 5 (1): 36-45. 10.1080/10400435.1993.10132205.CrossRefPubMed Phillips B, Zhao H: Predictors of assistive technology abandonment. Assist Technol. 1993, 5 (1): 36-45. 10.1080/10400435.1993.10132205.CrossRefPubMed
45.
go back to reference Riemer-Reiss ML, Wacker RR: Factors associated with assistive technology discontinuance among individuals with disabilities. J Rehabil. 2000, 66: 44-50. Riemer-Reiss ML, Wacker RR: Factors associated with assistive technology discontinuance among individuals with disabilities. J Rehabil. 2000, 66: 44-50.
46.
go back to reference Condie E, Scott H, Treweek S: Lower limb prosthetic outcome measures: a review of the literature 1995 to 2005. JPO. 2006, 18 (1S): 13-45. Condie E, Scott H, Treweek S: Lower limb prosthetic outcome measures: a review of the literature 1995 to 2005. JPO. 2006, 18 (1S): 13-45.
47.
go back to reference Theeven PJR, Hemmen B, Stevens CHC, Ilmer EC, Brink PRG, Seelen HAM: Feasibility of a new concept for measuring actual functional performance in daily life of transfemoral amputees. J Rehabil Med. 2010, 42 (8): 744-751. 10.2340/16501977-0591.CrossRefPubMed Theeven PJR, Hemmen B, Stevens CHC, Ilmer EC, Brink PRG, Seelen HAM: Feasibility of a new concept for measuring actual functional performance in daily life of transfemoral amputees. J Rehabil Med. 2010, 42 (8): 744-751. 10.2340/16501977-0591.CrossRefPubMed
48.
go back to reference Buell NC, Willingham LL, Allyn KJ, Hafner BJ, Smith DG: Evaluation of gait style to ascend and descend stairs for lower limb amputees. 11th World Congress of the International Society of Prosthetics and Orthotics. 2004, Hong Kong, 367- Buell NC, Willingham LL, Allyn KJ, Hafner BJ, Smith DG: Evaluation of gait style to ascend and descend stairs for lower limb amputees. 11th World Congress of the International Society of Prosthetics and Orthotics. 2004, Hong Kong, 367-
49.
go back to reference Buell NC, Willingham LL, Allyn KJ, Hafner BJ, Smith DG: Evaluation of gait style for hill descent for lower limb amputees. 11th World Congress of the International Society of Prosthetics and Orthotics. 2004, Hong Kong, 53- Buell NC, Willingham LL, Allyn KJ, Hafner BJ, Smith DG: Evaluation of gait style for hill descent for lower limb amputees. 11th World Congress of the International Society of Prosthetics and Orthotics. 2004, Hong Kong, 53-
50.
go back to reference Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R: Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008, 89 (3): 422-429. 10.1016/j.apmr.2007.11.005.CrossRefPubMed Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R: Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008, 89 (3): 422-429. 10.1016/j.apmr.2007.11.005.CrossRefPubMed
51.
go back to reference Rommers GM, Vos LD, Groothoff JW, Schuiling CH, Eisma WH: Epidemiology of lower limb amputees in the north of The Netherlands: aetiology, discharge destination and prosthetic use. Prosthet Orthot Int. 1997, 21 (2): 92-99.PubMed Rommers GM, Vos LD, Groothoff JW, Schuiling CH, Eisma WH: Epidemiology of lower limb amputees in the north of The Netherlands: aetiology, discharge destination and prosthetic use. Prosthet Orthot Int. 1997, 21 (2): 92-99.PubMed
52.
go back to reference English RD, Hubbard WA, McElroy GK: Establishment of consistent gait after fitting of new components. J Rehabil Res Dev. 1995, 32 (1): 32-35.PubMed English RD, Hubbard WA, McElroy GK: Establishment of consistent gait after fitting of new components. J Rehabil Res Dev. 1995, 32 (1): 32-35.PubMed
Metadata
Title
Measures and procedures utilized to determine the added value of microprocessor-controlled prosthetic knee joints: a systematic review
Authors
Patrick JR Theeven
Bea Hemmen
Peter RG Brink
Rob JEM Smeets
Henk AM Seelen
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2013
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-14-333

Other articles of this Issue 1/2013

BMC Musculoskeletal Disorders 1/2013 Go to the issue