Magnetization and demagnetization of magnetic dental attachments in a 3-T MRI system

Authors: Norio Hayashi, Akio Ogura, Toshio Tsuchihashi, Daisuke Takahashi, Tsuyoshi Matsuda, Shinya Seino, Tsukasa Doi

Published in: Radiological Physics and Technology | Issue 3/2017

Login to get access

Abstract

The purpose of this study was to evaluate the magnetization and demagnetization of magnetic dental attachments in a 3.0-T magnetic resonance imaging (MRI) scanner. A high-field-strength (3.0 T) MRI scanner (Achieva 3.0 T, Philips, Amsterdam, Netherlands) was used. Magnetic flux leakage was measured using a gaussmeter. To evaluate the magnetization and demagnetization of the magnetic assemblies and keepers caused by the moving in and out of the MRI scanner, the magnetic force of the attachments was measured before and after the table was moved in and out. Two settings were used wherein the magnetic assemblies and keepers were positioned on the table at angles of 0° or 90° with respect to the magnetic flux of the static magnetic field. The movement of the table was repeated 15 times. In addition, the retentive force of the magnetic dental attachments was measured after magnetic field exposure. The magnetic force of the magnetic attachments positioned at 0° decreased significantly after moving in and out of the MRI scanner (p < 0.05). In contrast, the magnetic force of the magnetic attachments positioned at 90° was stable after the movement of the table. The magnetic force of the keepers placed at both 0° and 90° was slightly increased after the movement of the table. At 0°, the retentive force of the magnet-keeper combinations decreased when the magnetic assembly was exposed to the strong magnetic flux of the MRI scanner. Therefore, the removal of all removable magnetic dentures is recommended before an MRI examination.
Literature
1.
go back to reference Hasegawa M, Umekawa Y, Nagai E, Ishigami T. Retentive force and magnetic flux leakage of magnetic attachment in various keeper and magnetic assembly combinations. J Prosthet Dent. 2011;105(4):266–71.CrossRefPubMed Hasegawa M, Umekawa Y, Nagai E, Ishigami T. Retentive force and magnetic flux leakage of magnetic attachment in various keeper and magnetic assembly combinations. J Prosthet Dent. 2011;105(4):266–71.CrossRefPubMed
2.
go back to reference S-I Masumi, Nagatomi K, Miyake S, Toyoda S. Removable magnetic dental attachment that permits magnetic resonance imaging. J Prosthet Dent. 1992;68(4):698–701.CrossRef S-I Masumi, Nagatomi K, Miyake S, Toyoda S. Removable magnetic dental attachment that permits magnetic resonance imaging. J Prosthet Dent. 1992;68(4):698–701.CrossRef
3.
go back to reference Miyata K, Hasegawa M, Abe Y, Tabuchi T, Namiki T, Ishigami T. Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI. Dentomaxillofac Radiol. 2012;41(8):668–74.CrossRefPubMedPubMedCentral Miyata K, Hasegawa M, Abe Y, Tabuchi T, Namiki T, Ishigami T. Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI. Dentomaxillofac Radiol. 2012;41(8):668–74.CrossRefPubMedPubMedCentral
4.
go back to reference Willinek WA, Schild HH. Clinical advantages of 3.0 T MRI over 1.5 T. Eur J Radiol. 2008;65(1):2–14.CrossRefPubMed Willinek WA, Schild HH. Clinical advantages of 3.0 T MRI over 1.5 T. Eur J Radiol. 2008;65(1):2–14.CrossRefPubMed
5.
go back to reference Shellock FG, Rothman B, Sarti D. Heating of the scrotum by high-field-strength MR imaging. Am J Roentgenol. 1990;154(6):1229–32.CrossRef Shellock FG, Rothman B, Sarti D. Heating of the scrotum by high-field-strength MR imaging. Am J Roentgenol. 1990;154(6):1229–32.CrossRef
6.
go back to reference Shellock FG, Curtis JS. MR imaging and biomedical implants, materials, and devices: an updated review. Radiology. 1991;180(2):541–50.CrossRefPubMed Shellock FG, Curtis JS. MR imaging and biomedical implants, materials, and devices: an updated review. Radiology. 1991;180(2):541–50.CrossRefPubMed
7.
go back to reference Shellock FG, Hatfield M, Simon BJ, Block S, Wamboldt J, Starewicz PM, et al. Implantable spinal fusion stimulator: assessment of MR safety and artifacts. J Magn Reson Imaging. 2000;12(2):214–23.CrossRefPubMed Shellock FG, Hatfield M, Simon BJ, Block S, Wamboldt J, Starewicz PM, et al. Implantable spinal fusion stimulator: assessment of MR safety and artifacts. J Magn Reson Imaging. 2000;12(2):214–23.CrossRefPubMed
8.
go back to reference Shellock FG. Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla. J Magn Reson Imaging. 2001;14(3):295–9.CrossRefPubMed Shellock FG. Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla. J Magn Reson Imaging. 2001;14(3):295–9.CrossRefPubMed
9.
go back to reference Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging. 2002;16(6):721–32.CrossRefPubMed Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging. 2002;16(6):721–32.CrossRefPubMed
10.
go back to reference Shellock FG. Magnetic resonance safety update 2002: implants and devices. J Magn Reson Imaging. 2002;16(5):485–96.CrossRefPubMed Shellock FG. Magnetic resonance safety update 2002: implants and devices. J Magn Reson Imaging. 2002;16(5):485–96.CrossRefPubMed
11.
go back to reference Shellock FG, Tkach JA, Ruggieri PM, Masaryk TJ. Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional (“long-bore”) and “short-bore” 1.5- and 3.0-Tesla MR systems. J Cardiovasc Magn Reson. 2003;5(2):387–97.CrossRefPubMed Shellock FG, Tkach JA, Ruggieri PM, Masaryk TJ. Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional (“long-bore”) and “short-bore” 1.5- and 3.0-Tesla MR systems. J Cardiovasc Magn Reson. 2003;5(2):387–97.CrossRefPubMed
12.
go back to reference Shellock FG, Crues JV. MR procedures: biologic effects, safety, and patient care. Radiology. 2004;232(3):635–52.CrossRefPubMed Shellock FG, Crues JV. MR procedures: biologic effects, safety, and patient care. Radiology. 2004;232(3):635–52.CrossRefPubMed
13.
go back to reference Shellock FG. Comments on MR heating tests of critical implants. J Magn Reson Imaging. 2007;26(5):1182–5.CrossRefPubMed Shellock FG. Comments on MR heating tests of critical implants. J Magn Reson Imaging. 2007;26(5):1182–5.CrossRefPubMed
14.
go back to reference Shellock FG, Woods TO, Crues JV 3rd. MR labeling information for implants and devices: explanation of terminology. Radiology. 2009;253(1):26–30.CrossRefPubMed Shellock FG, Woods TO, Crues JV 3rd. MR labeling information for implants and devices: explanation of terminology. Radiology. 2009;253(1):26–30.CrossRefPubMed
15.
go back to reference Shellock FG, Meepos LN, Stapleton MR, Valencerina S. In vitro magnetic resonance imaging evaluation of ossicular implants at 3 T. Otol Neurotol. 2012;33(5):871–7.CrossRefPubMed Shellock FG, Meepos LN, Stapleton MR, Valencerina S. In vitro magnetic resonance imaging evaluation of ossicular implants at 3 T. Otol Neurotol. 2012;33(5):871–7.CrossRefPubMed
16.
go back to reference Shellock FG, Spinazzi A. MRI safety update 2008: part 2, screening patients for MRI. Am J Roentgenol. 2008;191(4):1140–9.CrossRef Shellock FG, Spinazzi A. MRI safety update 2008: part 2, screening patients for MRI. Am J Roentgenol. 2008;191(4):1140–9.CrossRef
17.
go back to reference Hasegawa M, Miyata K, Abe Y, Ishii T, Ishigami T, Ohtani K, et al. 3-T MRI safety assessments of magnetic dental attachments and castable magnetic alloys. Dentomaxillofac Radiol. 2015;44(6):20150011.CrossRefPubMedPubMedCentral Hasegawa M, Miyata K, Abe Y, Ishii T, Ishigami T, Ohtani K, et al. 3-T MRI safety assessments of magnetic dental attachments and castable magnetic alloys. Dentomaxillofac Radiol. 2015;44(6):20150011.CrossRefPubMedPubMedCentral
18.
go back to reference Omatsu M, Obata T, Minowa K, Yokosawa K, Inagaki E, Ishizaka K, et al. Magnetic displacement force and torque on dental keepers in the static magnetic field of an MR scanner. J Magn Reson Imaging. 2014;40(6):1481–6.CrossRefPubMed Omatsu M, Obata T, Minowa K, Yokosawa K, Inagaki E, Ishizaka K, et al. Magnetic displacement force and torque on dental keepers in the static magnetic field of an MR scanner. J Magn Reson Imaging. 2014;40(6):1481–6.CrossRefPubMed
19.
go back to reference Takahashi D, Ogura A, Hayashi N, Seino S, Kawai R, Matsuda T, et al. The safety of MR conditional cochlear implant at 1.5 tesla magnetic resonance imaging system. Jpn J Radiol Technol. 2016;72(8):674–80.CrossRef Takahashi D, Ogura A, Hayashi N, Seino S, Kawai R, Matsuda T, et al. The safety of MR conditional cochlear implant at 1.5 tesla magnetic resonance imaging system. Jpn J Radiol Technol. 2016;72(8):674–80.CrossRef
20.
go back to reference Gegauff AG, Laurell KA, Thavendrarajah A, Rosenstiel SF. A potential MRI hazard: forces on dental magnet keepers. J Oral Rehabil. 1990;17(5):403–10.CrossRefPubMed Gegauff AG, Laurell KA, Thavendrarajah A, Rosenstiel SF. A potential MRI hazard: forces on dental magnet keepers. J Oral Rehabil. 1990;17(5):403–10.CrossRefPubMed
21.
go back to reference Beau A, Bossard D, Gebeile-Chauty S. Magnetic resonance imaging artefacts and fixed orthodontic attachments. Eur J Orthod. 2015;37(1):105–10.CrossRefPubMed Beau A, Bossard D, Gebeile-Chauty S. Magnetic resonance imaging artefacts and fixed orthodontic attachments. Eur J Orthod. 2015;37(1):105–10.CrossRefPubMed
22.
go back to reference Oriso K, Kobayashi T, Sasaki M, Uwano I, Kihara H, Kondo H. Impact of the static and radiofrequency magnetic fields produced by a 7 T MR imager on metallic dental materials. Magn Reson Med Sci. 2016;15(1):26–33.CrossRefPubMed Oriso K, Kobayashi T, Sasaki M, Uwano I, Kihara H, Kondo H. Impact of the static and radiofrequency magnetic fields produced by a 7 T MR imager on metallic dental materials. Magn Reson Med Sci. 2016;15(1):26–33.CrossRefPubMed
Metadata
Title
Magnetization and demagnetization of magnetic dental attachments in a 3-T MRI system
Authors
Norio Hayashi
Akio Ogura
Toshio Tsuchihashi
Daisuke Takahashi
Tsuyoshi Matsuda
Shinya Seino
Tsukasa Doi
Publication date
01-09-2017
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 3/2017
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-017-0399-0

Other articles of this Issue 3/2017

Radiological Physics and Technology 3/2017 Go to the issue