Abstract

Objective

Pelvic organ prolapse (POP) is clinically diagnosed in the supine position, where the effect of gravity is simulated by having the patients put strain on their pelvic floor. The objective of this study was to determine the degree of POP underestimation in the supine position based on magnetic resonance imaging (MRI) findings.

Methods

This prospective study was conducted with symptomatic POP grade ≥ 2 patients. Fifteen female patients were examined with an MRI system that allows supine and upright imaging. The differences between supine and upright in distances of the bladder neck, cervix, and pouch of Douglas from the pubococcygeal line (PCL) were estimated, together with changes in the genital hiatal area. Patients were scanned at rest and during straining. All distances were compared using the Wilcoxon ranking test.

Results

All mean distances from the PCL increased from the supine–strain to the upright–rest and from the supine–strain to the upright–strain position. These distances were found in the supine and upright positions: the bladder descended 1.3 cm to 1.4 cm, the cervix 1.1 cm to 2.2 cm, and the pouch of Douglas 0.8 cm to 1.5 cm respectively (all p values <0.05). The hiatal area was larger in the upright–strain position (mean 42.0 cm2; SD ±14.8) than during the supine–strain position (mean 33.5 cm2; SD ±14.5), with a p value of 0.02.

Conclusion

Upright MRI scanning of patients with POP grade ≥ 2 both at rest and during straining shows a significantly larger extent of the prolapse than that observed during supine straining.
Literature
1.
go back to reference Nygaard I, Barder M. Prevalence of symptomatic pelvic floor disorders in US women. JAMA. 2008;300(11):1311–6.CrossRef Nygaard I, Barder M. Prevalence of symptomatic pelvic floor disorders in US women. JAMA. 2008;300(11):1311–6.CrossRef
2.
go back to reference Hendrix S, Clark A, Nygaard I, Aragaki A, Barnabei V, McTiernan A. Pelvic organ prolapse in the Women’s Health Initiative: gravity and gravidity. Am J Obstet Gynecol. 2002;186(6):1160–6.CrossRef Hendrix S, Clark A, Nygaard I, Aragaki A, Barnabei V, McTiernan A. Pelvic organ prolapse in the Women’s Health Initiative: gravity and gravidity. Am J Obstet Gynecol. 2002;186(6):1160–6.CrossRef
3.
go back to reference Persu C, Chapple C, Cauni V, Gutue S, Geavlete P. Pelvic organ prolapse quantification system (POP-Q)—a new era in pelvic prolapse staging. J Med Life. 2011;4(1):75–81.PubMedPubMedCentral Persu C, Chapple C, Cauni V, Gutue S, Geavlete P. Pelvic organ prolapse quantification system (POP-Q)—a new era in pelvic prolapse staging. J Med Life. 2011;4(1):75–81.PubMedPubMedCentral
4.
go back to reference Pham T, Burgart A, Keller K. Current use of pelvic organ prolapse quantification by AUGS and ICS members. Female Pelvic Med Reconstr Surg. 2011;17:67–9.CrossRef Pham T, Burgart A, Keller K. Current use of pelvic organ prolapse quantification by AUGS and ICS members. Female Pelvic Med Reconstr Surg. 2011;17:67–9.CrossRef
5.
go back to reference Tumbarello J, Hsu Y, Lewicky-Gauppa C, Rohrerc S, DeLancey J. Do repetitive Valsalva maneuvers change maximum prolapse on dynamic MRI? Int Urogynecol J. 2010;21(10):1247–51.CrossRef Tumbarello J, Hsu Y, Lewicky-Gauppa C, Rohrerc S, DeLancey J. Do repetitive Valsalva maneuvers change maximum prolapse on dynamic MRI? Int Urogynecol J. 2010;21(10):1247–51.CrossRef
6.
go back to reference Altringer W, Saclarides T, Dominguez J, Brubaker L, Smith C. Four-contrast defecography: pelvic ‘floor-oscopy’. Dis Colon Rectum. 1995;38(7):695–9.CrossRef Altringer W, Saclarides T, Dominguez J, Brubaker L, Smith C. Four-contrast defecography: pelvic ‘floor-oscopy’. Dis Colon Rectum. 1995;38(7):695–9.CrossRef
7.
go back to reference Halligan S, Spence-Jones C, Kamm M, Bartram C. Dynamic cystoproctography and physiological testing in women with urinary stress incontinence and urogenital prolapse. Clin Radiol. 1996;51(11):785–90.CrossRef Halligan S, Spence-Jones C, Kamm M, Bartram C. Dynamic cystoproctography and physiological testing in women with urinary stress incontinence and urogenital prolapse. Clin Radiol. 1996;51(11):785–90.CrossRef
8.
go back to reference Kelvin FM, Hale DS, Maglinte DDT, Patten BJ, Benson JT. Female pelvic organ prolapse: diagnostic contribution of dynamic cystoproctography and comparison with physical examination. AJR Am J Roentgenol. 1999;173:31–7.CrossRef Kelvin FM, Hale DS, Maglinte DDT, Patten BJ, Benson JT. Female pelvic organ prolapse: diagnostic contribution of dynamic cystoproctography and comparison with physical examination. AJR Am J Roentgenol. 1999;173:31–7.CrossRef
9.
go back to reference Nicolau-Toulouse V, Tiwari P, Lee T. Does bilateral sacrospinous fixation with synthetic mesh recreate nulliparous pelvic anatomy? An MRI evaluation. Female Pelvic Med Reconstr Surg. 2014;20:222–7.CrossRef Nicolau-Toulouse V, Tiwari P, Lee T. Does bilateral sacrospinous fixation with synthetic mesh recreate nulliparous pelvic anatomy? An MRI evaluation. Female Pelvic Med Reconstr Surg. 2014;20:222–7.CrossRef
10.
go back to reference Örnö A, Dietz H. Levator co-activation is a significant confounder of pelvic organ descent on Valsalva maneuver. Ultrasound Obstet Gynecol. 2007;30:346–50.CrossRef Örnö A, Dietz H. Levator co-activation is a significant confounder of pelvic organ descent on Valsalva maneuver. Ultrasound Obstet Gynecol. 2007;30:346–50.CrossRef
11.
go back to reference El Sayed R, Alt CD, Maccioni F, Meissnitzer M, Masselli G, Manganaro L, Vinci V, Weishaupt D. Magnetic resonance imaging of pelvic floor dysfunction—joint recommendations of the ESUR and ESGAR Pelvic Floor Working Group. Eur Radiol. 2016;27(5):2067–85.CrossRef El Sayed R, Alt CD, Maccioni F, Meissnitzer M, Masselli G, Manganaro L, Vinci V, Weishaupt D. Magnetic resonance imaging of pelvic floor dysfunction—joint recommendations of the ESUR and ESGAR Pelvic Floor Working Group. Eur Radiol. 2016;27(5):2067–85.CrossRef
12.
go back to reference Betschart C, Chen L, Ashton-Miller JA, Delancey JO. On pelvic reference lines and the MR evaluation of genital prolapse: a proposal for standardization using the pelvic inclination correction system. Int Urogynecol J. 2013;24:1421–8.CrossRef Betschart C, Chen L, Ashton-Miller JA, Delancey JO. On pelvic reference lines and the MR evaluation of genital prolapse: a proposal for standardization using the pelvic inclination correction system. Int Urogynecol J. 2013;24:1421–8.CrossRef
13.
go back to reference Healy JC, Halligan S, Reznek RH, et al. Dynamic MR imaging compared with evacuation proctography when evaluating anorectal configuration and pelvic floor movement. Am J Roentgenol. 1997;169:775–9.CrossRef Healy JC, Halligan S, Reznek RH, et al. Dynamic MR imaging compared with evacuation proctography when evaluating anorectal configuration and pelvic floor movement. Am J Roentgenol. 1997;169:775–9.CrossRef
14.
go back to reference Elsayed RF. Overview of posterior compartment. In: Shaaban AM, editor. Diagnostic imaging: gynecology, 2nd edition. Amsterdam: Amirsys/Elsevier; 2015. p. 8/88–8/101. Elsayed RF. Overview of posterior compartment. In: Shaaban AM, editor. Diagnostic imaging: gynecology, 2nd edition. Amsterdam: Amirsys/Elsevier; 2015. p. 8/88–8/101.
15.
go back to reference Fauconnier A, Zareski E, Abichedid J, Bader G, Falissard B, Fritel X. Dynamic magnetic resonance imaging for grading pelvic organ prolapse according to the International Continence Society classification: which line should be used? Neurourol Urodyn. 2008;27:191–8.CrossRef Fauconnier A, Zareski E, Abichedid J, Bader G, Falissard B, Fritel X. Dynamic magnetic resonance imaging for grading pelvic organ prolapse according to the International Continence Society classification: which line should be used? Neurourol Urodyn. 2008;27:191–8.CrossRef
16.
go back to reference Dietz HP, Shek C, Clarke B. Biometry of the pubovisceral muscle and levator hiatus by three-dimensional pelvic floor ultrasound. Ultrasound Obstet Gynecol. 2005;25:580–5.CrossRef Dietz HP, Shek C, Clarke B. Biometry of the pubovisceral muscle and levator hiatus by three-dimensional pelvic floor ultrasound. Ultrasound Obstet Gynecol. 2005;25:580–5.CrossRef
17.
go back to reference Barber MD, Lambers AR, Visco AG, Bump RC. Effect of patient position on clinical evaluation of pelvic organ prolapse. Obstet Gynecol. 2000;96:18–22.PubMed Barber MD, Lambers AR, Visco AG, Bump RC. Effect of patient position on clinical evaluation of pelvic organ prolapse. Obstet Gynecol. 2000;96:18–22.PubMed
18.
go back to reference Cardozo L, Staskin D. Textbook of female urology and urogynecology. Boca Raton, FL: CRC Press, 2010.CrossRef Cardozo L, Staskin D. Textbook of female urology and urogynecology. Boca Raton, FL: CRC Press, 2010.CrossRef
19.
go back to reference Lakeman MME, Zijta FM, Peringa J, Nederveen AJ, Stoker J, Roovers JPWR. Dynamic magnetic resonance imaging to quantify pelvic organ prolapse: reliability of assessment and correlation with clinical findings and pelvic floor symptoms. Int Urogynecol J. 2012;23(11):1547–54.CrossRef Lakeman MME, Zijta FM, Peringa J, Nederveen AJ, Stoker J, Roovers JPWR. Dynamic magnetic resonance imaging to quantify pelvic organ prolapse: reliability of assessment and correlation with clinical findings and pelvic floor symptoms. Int Urogynecol J. 2012;23(11):1547–54.CrossRef
20.
go back to reference Iacobellis F, Brillantino A, Renzi A, Serra N, Feragalli B, Iacomino A, et al. MR imaging in diagnosis of pelvic floor descent: supine versus sitting position. Gastroenterol Res Pract. 2015;2016:1–12.CrossRef Iacobellis F, Brillantino A, Renzi A, Serra N, Feragalli B, Iacomino A, et al. MR imaging in diagnosis of pelvic floor descent: supine versus sitting position. Gastroenterol Res Pract. 2015;2016:1–12.CrossRef
21.
go back to reference Abdulaziz M, Kavanagh A, Stothers L, Manab A. Relevance of open magnetic imaging position (sitting and standing) to quantify pelvic organ prolapse in women. Can Urol Assoc. 2018. 12(11):E453–60. Abdulaziz M, Kavanagh A, Stothers L, Manab A. Relevance of open magnetic imaging position (sitting and standing) to quantify pelvic organ prolapse in women. Can Urol Assoc. 2018. 12(11):E453–60.
22.
go back to reference Vergeldt TFM, Weemhoff M, Inthout J, Kluivers KB. Risk factors for pelvic organ prolapse and its recurrence: a systematic review. Int Urogynecol J. 2015;26(1):1559–73.CrossRef Vergeldt TFM, Weemhoff M, Inthout J, Kluivers KB. Risk factors for pelvic organ prolapse and its recurrence: a systematic review. Int Urogynecol J. 2015;26(1):1559–73.CrossRef
23.
go back to reference Broekhuis SR, Kluivers KB, Hendriks JCM, Fütterer JJ, Barentsz JO, Vierhout ME. POP-Q, dynamic MR imaging, and perineal ultrasonography: do they agree in the quantification of female pelvic organ prolapse? Int Urogynecol J. 2009;20(5):541–9.CrossRef Broekhuis SR, Kluivers KB, Hendriks JCM, Fütterer JJ, Barentsz JO, Vierhout ME. POP-Q, dynamic MR imaging, and perineal ultrasonography: do they agree in the quantification of female pelvic organ prolapse? Int Urogynecol J. 2009;20(5):541–9.CrossRef
24.
go back to reference Broekhuis SR, Fütterer JJ, Hendriks JCM, Barentsz JO, Vierhout ME, Kluivers KB. Symptoms of pelvic floor dysfunction are poorly correlated with findings on clinical examination and dynamic MR imaging of the pelvic floor. Int Urogynecol J. 2009;20(10):1169–74.CrossRef Broekhuis SR, Fütterer JJ, Hendriks JCM, Barentsz JO, Vierhout ME, Kluivers KB. Symptoms of pelvic floor dysfunction are poorly correlated with findings on clinical examination and dynamic MR imaging of the pelvic floor. Int Urogynecol J. 2009;20(10):1169–74.CrossRef
Metadata
Title
Underestimation of pelvic organ prolapse in the supine straining position, based on magnetic resonance imaging findings
Authors
Anique T. M. Grob
Judith olde Heuvel
Jurgen J. Futterer
Diana Massop
Angelique L. Veenstra van Nieuwenhoven
Frank F. J. Simonis
Carl H. van der Vaart
Publication date
01-11-2019
Publisher
Springer International Publishing
Published in
International Urogynecology Journal / Issue 11/2019
Print ISSN: 0937-3462
Electronic ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-018-03862-0

Other articles of this Issue 11/2019

International Urogynecology Journal 11/2019 Go to the issue