Skip to main content
Top
Published in: Journal of Cardiothoracic Surgery 1/2019

Open Access 01-12-2019 | Magnetic Resonance Imaging | Case report

Quantitative evaluation using single-photon emission computed tomography with acetazolamide is reliable for preoperative evaluation before cardiac surgery in severe carotid intracranial artery stenotic and/or occlusive disease: a case report

Authors: Eiki Tayama, Ryusuke Mori, Tomohiro Ueda, Ken-ichi Imasaka, Yukihiro Tomita, Shigeki Morita

Published in: Journal of Cardiothoracic Surgery | Issue 1/2019

Login to get access

Abstract

Background

Severe carotid and intracranial artery stenosis disease (CIAD) is major risk for perioperative stroke in coronary artery bypass grafting. Then, preoperative risk assessment is quite important.

Case presentation

A 58-years old Japanese woman with bilateral carotid stenosis and bilateral middle cerebral artery occlusion was suffered from worsening effort angina due to severe three coronary vessel disease. Magnetic resonance imaging angiography demonstrated severe carotid and intracranial vessel stenosis. Selective carotid/cerebral angiography also showed severe stenosis and delayed filling of the right internal carotid artery and moderate stenosis of the left internal carotid artery, with occlusion of the bilateral middle cerebral arteries. However, quantitative evaluation with brain perfusion, single-photon emission computed tomography (SPECT) with acetazolamide showed depleted cerebral perfusion volume and vascular responses, particularly in the left middle cerebral artery area. However, both sides of MCA reserve cerebral blood flow was maintained at > 34 ml/100 g/min. So, we finally considered that her cerebral perfusion reserve was maintained a certain level and could tolerate open heart surgery. Then, she underwent off-pump coronary artery grafting. Before sternotomy, prophylactic intra-aortic balloon pump support was used to minimize possible perioperative stroke. As a result, hemodynamic status and brain regional oxygen saturation were stable throughout the operation, and recovered uneventfully.

Conclusions

Preoperative quantitative evaluation using brain perfusion SPECT with acetazolamide is useful in assessing hemodynamic cerebrovascular risk in patients with severe obstructive CIAD. Off pump coronary artery bypass grafting with intra aortic balloon pump assist is a good option for prevention of cerebrovascular morbidity in ischemic heart disease with severe CIAD.
Literature
1.
go back to reference Naylor AR, Mehta Z, Rothwell PM, Bell PRF. Carotid artery disease and stroke during coronary artery bypass: a critical review of the literature. Eur J Vasc Endovasc Surg. 2002;23:283–94.CrossRef Naylor AR, Mehta Z, Rothwell PM, Bell PRF. Carotid artery disease and stroke during coronary artery bypass: a critical review of the literature. Eur J Vasc Endovasc Surg. 2002;23:283–94.CrossRef
2.
go back to reference Tsuda K, Shiiya N, Washiyama N, Yamashita K, Ohkuma K, Takahashi D, Kando Y, Natsume K, Yamanaka K, Takeuchi Y. Carotid stenosis with impaired brain flow reserve is associated with an increased risk of stroke in on-pump cardiovascular surgery. Interact Cardiovasc Thorac Surg. 2018;27:75–80.CrossRef Tsuda K, Shiiya N, Washiyama N, Yamashita K, Ohkuma K, Takahashi D, Kando Y, Natsume K, Yamanaka K, Takeuchi Y. Carotid stenosis with impaired brain flow reserve is associated with an increased risk of stroke in on-pump cardiovascular surgery. Interact Cardiovasc Thorac Surg. 2018;27:75–80.CrossRef
3.
go back to reference Kuroda S, Houkin K, Kamiyama H, Mitsumori K, Iwasaki Y, Abe H. Long-term prognosis of medically treated patients with internal carotid or middle cerebral artery occlusion: can acetazolamide test predict it? Stroke. 2001;32:2110–6.CrossRef Kuroda S, Houkin K, Kamiyama H, Mitsumori K, Iwasaki Y, Abe H. Long-term prognosis of medically treated patients with internal carotid or middle cerebral artery occlusion: can acetazolamide test predict it? Stroke. 2001;32:2110–6.CrossRef
4.
go back to reference Imasaka K, Yasaka M, Tayama E, Tomita Y. Obstructive carotid and/or intracranial artery disease rarely affects the incidence of haemodynamic ischemic stroke during cardiac surgery: a study on brain perfusion single-photon emission computed tomography with acetazolamide. Eur J Cardiothorac Surg. 2015;48:739–46. https://doi.org/10.1093/ejcts/ezu502.CrossRefPubMed Imasaka K, Yasaka M, Tayama E, Tomita Y. Obstructive carotid and/or intracranial artery disease rarely affects the incidence of haemodynamic ischemic stroke during cardiac surgery: a study on brain perfusion single-photon emission computed tomography with acetazolamide. Eur J Cardiothorac Surg. 2015;48:739–46. https://​doi.​org/​10.​1093/​ejcts/​ezu502.CrossRefPubMed
5.
go back to reference Imasaka K, Tayama E, Morita S, Tomita Y. Neurological outcome and efficacy of intensive craniocervical screening for elective cardiac surgery. Interact Cardiovasc Thorac Surg. 2018;26:216–23.CrossRef Imasaka K, Tayama E, Morita S, Tomita Y. Neurological outcome and efficacy of intensive craniocervical screening for elective cardiac surgery. Interact Cardiovasc Thorac Surg. 2018;26:216–23.CrossRef
6.
go back to reference Yamauchi H, Fukuyama H, Nagahama Y, Nabatame H, Nakamura K, Yamamoto Y, et al. Evidence of misery perfusion and risk for recurrent stroke in major cerebral arterial occlusive disease from PET. J Neurol Neurosurg Psychiatry. 1996;61:18–25.CrossRef Yamauchi H, Fukuyama H, Nagahama Y, Nabatame H, Nakamura K, Yamamoto Y, et al. Evidence of misery perfusion and risk for recurrent stroke in major cerebral arterial occlusive disease from PET. J Neurol Neurosurg Psychiatry. 1996;61:18–25.CrossRef
7.
go back to reference Mizumura S, Nakagawara J, Takahashi M, Kumita S, Cho K, Nakajo H, Toba M, Kumazaki T. Three-dimensional display in staging hemodynamic brain ischemia for JET study: objective evaluation using SEE analysis and 3D-SSP display. Ann Nucl Med. 2004;18:13–21.CrossRef Mizumura S, Nakagawara J, Takahashi M, Kumita S, Cho K, Nakajo H, Toba M, Kumazaki T. Three-dimensional display in staging hemodynamic brain ischemia for JET study: objective evaluation using SEE analysis and 3D-SSP display. Ann Nucl Med. 2004;18:13–21.CrossRef
8.
go back to reference Caplan LR, Hennerici M. Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke. Arch Neurol. 1998;55:1475–82.CrossRef Caplan LR, Hennerici M. Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke. Arch Neurol. 1998;55:1475–82.CrossRef
9.
go back to reference Silvestrini M, Vernieri F, Pasqualetti P, Matteis M, Passarelli F, Troisi E, Caltagirone C. Impaired cerebral vasoreactivity and risk of stroke in patients with asymp- tomatic carotid artery stenosis. JAMA. 2000;283:2122–7.CrossRef Silvestrini M, Vernieri F, Pasqualetti P, Matteis M, Passarelli F, Troisi E, Caltagirone C. Impaired cerebral vasoreactivity and risk of stroke in patients with asymp- tomatic carotid artery stenosis. JAMA. 2000;283:2122–7.CrossRef
10.
go back to reference Lamy A, Devereaux PJ, Prabhakaran D, Taggart DP, Hu S, Paolasso E, Straka Z, Piegas LS, Akar AR, Jain AR, Noiseux N, Padmanabhan C, Bahamondes JC, Novick RJ, Vaijyanath P, Reddy SK, Tao L, Olavegogeascoechea PA, Airan B, Sulling TA, Whitlock RP, Ou Y, Pogue J, Chrolavicius S, Yusuf S. Effects of off-pump and on-pump coronary- artery bypass grafting at 1 year. N Engl J Med. 2013;368:1179–88.CrossRef Lamy A, Devereaux PJ, Prabhakaran D, Taggart DP, Hu S, Paolasso E, Straka Z, Piegas LS, Akar AR, Jain AR, Noiseux N, Padmanabhan C, Bahamondes JC, Novick RJ, Vaijyanath P, Reddy SK, Tao L, Olavegogeascoechea PA, Airan B, Sulling TA, Whitlock RP, Ou Y, Pogue J, Chrolavicius S, Yusuf S. Effects of off-pump and on-pump coronary- artery bypass grafting at 1 year. N Engl J Med. 2013;368:1179–88.CrossRef
11.
go back to reference Diegeler A, Börgermann J, Kappert U, Breuer M, Böning A, Ursulescu A, Rastan A, Holzhey D, Treede H, Rieß FC, Veeckmann P, Asfoor A, Reents W, Zacher M, Hilker M, GOPCABE Study Group. Off-pump versus on-pump coronary-artery bypass grafting in elderly patients. N Engl J Med. 2013;368:1189–98.CrossRef Diegeler A, Börgermann J, Kappert U, Breuer M, Böning A, Ursulescu A, Rastan A, Holzhey D, Treede H, Rieß FC, Veeckmann P, Asfoor A, Reents W, Zacher M, Hilker M, GOPCABE Study Group. Off-pump versus on-pump coronary-artery bypass grafting in elderly patients. N Engl J Med. 2013;368:1189–98.CrossRef
12.
go back to reference Shroyer AL, Grover FL, Hattler B, Collins JF, McDonald GO, Kozora E, Lucke JC, Baltz JH, Novitzky D. On-pump versus off-pump coronary-artery bypass surgery. N Engl J Med. 2009;361:1827–37.CrossRef Shroyer AL, Grover FL, Hattler B, Collins JF, McDonald GO, Kozora E, Lucke JC, Baltz JH, Novitzky D. On-pump versus off-pump coronary-artery bypass surgery. N Engl J Med. 2009;361:1827–37.CrossRef
13.
go back to reference Nishiyama K, Horiguchi M, Shizuta S, Doi T, Ehara N, Tanuguchi R, Haruna Y, Nakagawa Y, Furukawa Y, Fukushima M, Kita T, Kimura T. Temporal pattern of strokes after on-pump and off- pump coronary artery bypass graft surgery. Ann Thorac Surg. 2009;87:1839–45.CrossRef Nishiyama K, Horiguchi M, Shizuta S, Doi T, Ehara N, Tanuguchi R, Haruna Y, Nakagawa Y, Furukawa Y, Fukushima M, Kita T, Kimura T. Temporal pattern of strokes after on-pump and off- pump coronary artery bypass graft surgery. Ann Thorac Surg. 2009;87:1839–45.CrossRef
14.
go back to reference Puskas JD, Kilgo PD, Lattouf OM, Thourani VH, Cooper WA, Vassiliades TA, Chen EP, Vega JD, Guyton RA. Off-pump coronary bypass provides reduced mortality and morbidity and equivalent 10-year survival. Ann Thorac Surg. 2008;86:1139–46.CrossRef Puskas JD, Kilgo PD, Lattouf OM, Thourani VH, Cooper WA, Vassiliades TA, Chen EP, Vega JD, Guyton RA. Off-pump coronary bypass provides reduced mortality and morbidity and equivalent 10-year survival. Ann Thorac Surg. 2008;86:1139–46.CrossRef
15.
go back to reference Doi K, Yaku H. Importance of cerebral artery risk evaluation before off-pump coronary artery bypass grafting to avoid perioperative stroke. Eur J Cardiothorac Surg. 2010;38:568–72.CrossRef Doi K, Yaku H. Importance of cerebral artery risk evaluation before off-pump coronary artery bypass grafting to avoid perioperative stroke. Eur J Cardiothorac Surg. 2010;38:568–72.CrossRef
16.
go back to reference Kim KB, Lim C, Ahn H, Yang JK. Intraaortic balloon pump therapy facilitates posterior vessel off-pump coronary artery bypass grafting in high-risk patients. Ann Thorac Surg. 2001;71:1964–8.CrossRef Kim KB, Lim C, Ahn H, Yang JK. Intraaortic balloon pump therapy facilitates posterior vessel off-pump coronary artery bypass grafting in high-risk patients. Ann Thorac Surg. 2001;71:1964–8.CrossRef
17.
go back to reference Pfluecke C, Christoph M, Kolschmann S, Tarnowski D, Forkmann M, Jellinghaus S, Poitz DM, Wunderlich PC, Strasser RH, Schoen S, Ibrahim K. Intra-aortic balloon pump (IABP) counterpulsation improves cerebral perfusion in patients with decreased left ventricular function. Perfusion. 2014;29:511–6.CrossRef Pfluecke C, Christoph M, Kolschmann S, Tarnowski D, Forkmann M, Jellinghaus S, Poitz DM, Wunderlich PC, Strasser RH, Schoen S, Ibrahim K. Intra-aortic balloon pump (IABP) counterpulsation improves cerebral perfusion in patients with decreased left ventricular function. Perfusion. 2014;29:511–6.CrossRef
18.
go back to reference Tsukube T, Okada M, Ataka K, Ozaki N. Coronary artery bypass grafting in a patient with brain ischemia. J Cardiovasc Surg. 2001;42:349–51. Tsukube T, Okada M, Ataka K, Ozaki N. Coronary artery bypass grafting in a patient with brain ischemia. J Cardiovasc Surg. 2001;42:349–51.
19.
go back to reference Tranmer BI, Peniston C, Iacobacci R, Salerno TA, Hudson AR. Intra-aortic balloon counterpulsation: a treatment for Ischaemic stroke? Neurol Res. 1989;11(2):109–13.CrossRef Tranmer BI, Peniston C, Iacobacci R, Salerno TA, Hudson AR. Intra-aortic balloon counterpulsation: a treatment for Ischaemic stroke? Neurol Res. 1989;11(2):109–13.CrossRef
Metadata
Title
Quantitative evaluation using single-photon emission computed tomography with acetazolamide is reliable for preoperative evaluation before cardiac surgery in severe carotid intracranial artery stenotic and/or occlusive disease: a case report
Authors
Eiki Tayama
Ryusuke Mori
Tomohiro Ueda
Ken-ichi Imasaka
Yukihiro Tomita
Shigeki Morita
Publication date
01-12-2019

Other articles of this Issue 1/2019

Journal of Cardiothoracic Surgery 1/2019 Go to the issue