Skip to main content
Top
Published in: European Radiology 7/2019

01-07-2019 | Magnetic Resonance Imaging | Magnetic Resonance

Modified CAIPIRINHA-VIBE without view-sharing on gadoxetic acid–enhanced multi-arterial phase MR imaging for diagnosing hepatocellular carcinoma: comparison with the CAIPIRINHA-Dixon-TWIST-VIBE

Authors: Seung Baek Hong, Nam Kyung Lee, Suk Kim, Hyeong Il Seo, Hyun Sung Kim, Dong Uk Kim, Tae Un Kim, Hwa Seong Ryu

Published in: European Radiology | Issue 7/2019

Login to get access

Abstract

Purpose

We evaluated the detection rate and degree of motion artifact of the modified CAIPIRINHA-VIBE (mC-VIBE) without view-sharing and compare them with the CAIPIRINHA-Dixon-TWIST-VIBE (CDT-VIBE) with view-sharing on multi-arterial gadoxetic acid–enhanced liver MRI in the assessment of hepatocellular carcinoma (HCC).

Material and methods

We retrospectively identified 114 pathological-proven hepatic tumors in 114 patients with risk of HCC who underwent multi-arterial gadoxetic acid–enhanced MRI between June 2016 and June 2018. All patients underwent triple arterial phase imaging using the mC-VIBE without view-sharing (54 patients; 49 HCCs and 5 non-HCCs) or the CDT-VIBE with view-sharing (60 patients; 55 HCCs and 5 non-HCCs). We compared the detection rate of two sequences for HCC, with reference to LI-RADS.V.2017. We also compared the mean motion scores and proportions of transient severe motion (TSM) in two sequences.

Result

For the examination using the mC-VIBE, the HCC-detection rate was significantly higher, compared with that using CDT-VIBE (93.9% [46/49] vs 80.0% [44/55], respectively; p = 0.047). For the examination with the mC-VIBE, mean motion scores were significantly lower compared with those of CDT-VIBE for all multi-arterial phases (1.21, 1.19, and 1.15 vs. 1.82, 1.85, and 1.84, respectively; p < 0.001 for all three comparisons). The proportion of TSM in the CDT-VIBE was significantly higher than that in the mC-VIBE (15.0% [9/60] vs 0.0% [0/54], respectively; p = 0.003).

Conclusion

In multi-arterial phase gadoxetic acid–enhanced MRI, the mC-VIBE sequence without view-sharing has slightly higher HCC-detection rate and fewer motion artifacts compared with CDT-VIBE with view-sharing.

Key Points

Multi-arterial phase using the mC-VIBE without view-sharing can overcome motion artifacts, resulting in providing optimal arterial phase imaging.
The HCC-detection rate is slightly higher with the mC-VIBE vs. CAIPIRINHA-Dixon-TWIST-VIBE with view-sharing (CDT-VIBE).
View-sharing of CDT-VIBE in the multi-arterial phase is associated with increased frequency of TSM.
Literature
1.
go back to reference Mitchell DG, Bruix J, Sherman M, Sirlin CB (2015) LI-RADS (Liver Imaging Reporting and Data System): summary, discussion, and consensus of the LI-RADS Management Working Group and future directions. Hepatology 61:1056–1065CrossRefPubMed Mitchell DG, Bruix J, Sherman M, Sirlin CB (2015) LI-RADS (Liver Imaging Reporting and Data System): summary, discussion, and consensus of the LI-RADS Management Working Group and future directions. Hepatology 61:1056–1065CrossRefPubMed
2.
go back to reference Purysko AS, Remer EM, Coppa CP, Leao Filho HM, Thupili CR, Veniero JC (2012) LI-RADS: a case-based review of the new categorization of liver findings in patients with end-stage liver disease. Radiographics 32:1977–1995CrossRefPubMed Purysko AS, Remer EM, Coppa CP, Leao Filho HM, Thupili CR, Veniero JC (2012) LI-RADS: a case-based review of the new categorization of liver findings in patients with end-stage liver disease. Radiographics 32:1977–1995CrossRefPubMed
3.
go back to reference An C, Rakhmonova G, Choi JY, Kim MJ (2016) Liver imaging reporting and data system (LI-RADS) version 2014: understanding and application of the diagnostic algorithm. Clin Mol Hepatol 22:296–307CrossRefPubMedPubMedCentral An C, Rakhmonova G, Choi JY, Kim MJ (2016) Liver imaging reporting and data system (LI-RADS) version 2014: understanding and application of the diagnostic algorithm. Clin Mol Hepatol 22:296–307CrossRefPubMedPubMedCentral
4.
go back to reference Chen N, Motosugi U, Morisaka H et al (2016) Added value of a gadoxetic acid-enhanced hepatocyte-phase image to the LI-RADS system for diagnosing hepatocellular carcinoma. Magn Reson Med Sci 15:49–59CrossRefPubMed Chen N, Motosugi U, Morisaka H et al (2016) Added value of a gadoxetic acid-enhanced hepatocyte-phase image to the LI-RADS system for diagnosing hepatocellular carcinoma. Magn Reson Med Sci 15:49–59CrossRefPubMed
5.
go back to reference Tirkes T, Mehta P, Aisen AM, Lall C, Akisik F (2015) Comparison of dynamic phase enhancement of hepatocellular carcinoma using gadoxetate disodium vs gadobenate dimeglumine. J Comput Assist Tomogr 39:479–482CrossRefPubMed Tirkes T, Mehta P, Aisen AM, Lall C, Akisik F (2015) Comparison of dynamic phase enhancement of hepatocellular carcinoma using gadoxetate disodium vs gadobenate dimeglumine. J Comput Assist Tomogr 39:479–482CrossRefPubMed
6.
go back to reference Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724CrossRefPubMed Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724CrossRefPubMed
7.
go back to reference Tamada T, Ito K, Yoshida K et al (2011) Comparison of three different injection methods for arterial phase of Gd-EOB-DTPA enhanced MR imaging of the liver. Eur J Radiol 80:e284–e288CrossRefPubMed Tamada T, Ito K, Yoshida K et al (2011) Comparison of three different injection methods for arterial phase of Gd-EOB-DTPA enhanced MR imaging of the liver. Eur J Radiol 80:e284–e288CrossRefPubMed
8.
go back to reference Zech CJ, Vos B, Nordell A et al (2009) Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA. Invest Radiol 44:305–310CrossRefPubMed Zech CJ, Vos B, Nordell A et al (2009) Vascular enhancement in early dynamic liver MR imaging in an animal model: comparison of two injection regimen and two different doses Gd-EOB-DTPA (gadoxetic acid) with standard Gd-DTPA. Invest Radiol 44:305–310CrossRefPubMed
9.
go back to reference Secil M, Obuz F, Altay C et al (2008) The role of dynamic subtraction MRI in detection of hepatocellular carcinoma. Diagn Interv Radiol 14:200–204PubMed Secil M, Obuz F, Altay C et al (2008) The role of dynamic subtraction MRI in detection of hepatocellular carcinoma. Diagn Interv Radiol 14:200–204PubMed
10.
go back to reference An C, Park MS, Kim D et al (2013) Added value of subtraction imaging in detecting arterial enhancement in small (<3 cm) hepatic nodules on dynamic contrast-enhanced MRI in patients at high risk of hepatocellular carcinoma. Eur Radiol 23:924–930CrossRefPubMed An C, Park MS, Kim D et al (2013) Added value of subtraction imaging in detecting arterial enhancement in small (<3 cm) hepatic nodules on dynamic contrast-enhanced MRI in patients at high risk of hepatocellular carcinoma. Eur Radiol 23:924–930CrossRefPubMed
11.
go back to reference Fujinaga Y, Ohya A, Tokoro H et al (2014) Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase. Eur Radiol 24:1290–1299CrossRefPubMed Fujinaga Y, Ohya A, Tokoro H et al (2014) Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase. Eur Radiol 24:1290–1299CrossRefPubMed
12.
go back to reference Pietryga JA, Burke LM, Marin D, Jaffe TA, Bashir MR (2014) Respiratory motion artifact affecting hepatic arterial phase imaging with gadoxetate disodium: examination recovery with a multiple arterial phase acquisition. Radiology 271:426–434CrossRefPubMed Pietryga JA, Burke LM, Marin D, Jaffe TA, Bashir MR (2014) Respiratory motion artifact affecting hepatic arterial phase imaging with gadoxetate disodium: examination recovery with a multiple arterial phase acquisition. Radiology 271:426–434CrossRefPubMed
13.
go back to reference Riffel P, Attenberger UI, Kannengiesser S et al (2013) Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Invest Radiol 48:554–561CrossRefPubMed Riffel P, Attenberger UI, Kannengiesser S et al (2013) Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Invest Radiol 48:554–561CrossRefPubMed
14.
go back to reference Yu MH, Lee JM, Yoon JH, Kiefer B, Han JK, Choi BI (2013) Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 38:1020–1026CrossRefPubMed Yu MH, Lee JM, Yoon JH, Kiefer B, Han JK, Choi BI (2013) Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 38:1020–1026CrossRefPubMed
15.
go back to reference Breuer FA, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM (2005) Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med 53:684–691CrossRefPubMed Breuer FA, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM (2005) Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med 53:684–691CrossRefPubMed
16.
go back to reference Wile GE, Leyendecker JR (2010) Magnetic resonance imaging of the liver: sequence optimization and artifacts. Magn Reson Imaging Clin N Am 18(525–547):xi Wile GE, Leyendecker JR (2010) Magnetic resonance imaging of the liver: sequence optimization and artifacts. Magn Reson Imaging Clin N Am 18(525–547):xi
17.
go back to reference Vogt FM, Antoch G, Hunold P et al (2005) Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging 21:376–382CrossRefPubMed Vogt FM, Antoch G, Hunold P et al (2005) Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging 21:376–382CrossRefPubMed
18.
go back to reference Le Y, Kroeker R, Kipfer HD, Lin C (2012) Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression. J Magn Reson Imaging 36:483–491CrossRefPubMed Le Y, Kroeker R, Kipfer HD, Lin C (2012) Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression. J Magn Reson Imaging 36:483–491CrossRefPubMed
19.
go back to reference Michaely HJ, Morelli JN, Budjan J et al (2013) CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution. Invest Radiol 48:590–597CrossRefPubMed Michaely HJ, Morelli JN, Budjan J et al (2013) CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution. Invest Radiol 48:590–597CrossRefPubMed
20.
go back to reference Kazmierczak PM, Theisen D, Thierfelder KM et al (2015) Improved detection of hypervascular liver lesions with CAIPIRINHA-Dixon-TWIST-volume-interpolated breath-hold examination. Invest Radiol 50:153–160CrossRefPubMed Kazmierczak PM, Theisen D, Thierfelder KM et al (2015) Improved detection of hypervascular liver lesions with CAIPIRINHA-Dixon-TWIST-volume-interpolated breath-hold examination. Invest Radiol 50:153–160CrossRefPubMed
21.
go back to reference Ikram NS, Yee J, Weinstein S et al (2017) Multiple arterial phase MRI of arterial hypervascular hepatic lesions: improved arterial phase capture and lesion enhancement. Abdom Radiol (NY) 42:870–876CrossRefPubMedCentral Ikram NS, Yee J, Weinstein S et al (2017) Multiple arterial phase MRI of arterial hypervascular hepatic lesions: improved arterial phase capture and lesion enhancement. Abdom Radiol (NY) 42:870–876CrossRefPubMedCentral
22.
go back to reference Gruber L, Rainer V, Plaikner M, Kremser C, Jaschke W, Henninger B (2018) CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol 28:2013–2021CrossRefPubMed Gruber L, Rainer V, Plaikner M, Kremser C, Jaschke W, Henninger B (2018) CAIPIRINHA-Dixon-TWIST (CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium: a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol 28:2013–2021CrossRefPubMed
24.
go back to reference Davenport MS, Viglianti BL, Al-Hawary MM et al (2013) Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine: effect on arterial phase image quality. Radiology 266:452–461CrossRefPubMed Davenport MS, Viglianti BL, Al-Hawary MM et al (2013) Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine: effect on arterial phase image quality. Radiology 266:452–461CrossRefPubMed
25.
go back to reference Bruix J, Sherman M, American Association for the Study of Liver Disease (2011) Management of hepatocellular carcinoma: an update. Hepatology 53:1020–1022 Bruix J, Sherman M, American Association for the Study of Liver Disease (2011) Management of hepatocellular carcinoma: an update. Hepatology 53:1020–1022
26.
go back to reference Lencioni R, Llovet JM (2010) Modified RECIST (mRECIST) assessment for hepatocellular carcinoma. Semin Liver Dis 30:52–60CrossRefPubMed Lencioni R, Llovet JM (2010) Modified RECIST (mRECIST) assessment for hepatocellular carcinoma. Semin Liver Dis 30:52–60CrossRefPubMed
27.
go back to reference Brismar TB, Dahlstrom N, Edsborg N, Persson A, Smedby O, Albiin N (2009) Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: a comparison in healthy volunteers. Acta Radiol 50:709–715CrossRefPubMed Brismar TB, Dahlstrom N, Edsborg N, Persson A, Smedby O, Albiin N (2009) Liver vessel enhancement by Gd-BOPTA and Gd-EOB-DTPA: a comparison in healthy volunteers. Acta Radiol 50:709–715CrossRefPubMed
28.
go back to reference Tamada T, Ito K, Sone T et al (2009) Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA. J Magn Reson Imaging 29:636–640CrossRefPubMed Tamada T, Ito K, Sone T et al (2009) Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA. J Magn Reson Imaging 29:636–640CrossRefPubMed
29.
go back to reference Attenberger UI, Haneder S, Morelli JN, Diehl SJ, Schoenberg SO, Michaely HJ (2010) Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography. Radiology 257:879–887CrossRefPubMed Attenberger UI, Haneder S, Morelli JN, Diehl SJ, Schoenberg SO, Michaely HJ (2010) Peripheral arterial occlusive disease: evaluation of a high spatial and temporal resolution 3-T MR protocol with a low total dose of gadolinium versus conventional angiography. Radiology 257:879–887CrossRefPubMed
30.
go back to reference Giesel FL, Runge V, Kirchin M et al (2010) Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T: a quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent. J Comput Assist Tomogr 34:678–683CrossRefPubMed Giesel FL, Runge V, Kirchin M et al (2010) Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T: a quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent. J Comput Assist Tomogr 34:678–683CrossRefPubMed
31.
go back to reference Michaely HJ, Attenberger UI, Dietrich O et al (2008) Feasibility of gadofosveset-enhanced steady-state magnetic resonance angiography of the peripheral vessels at 3 tesla with Dixon fat saturation. Invest Radiol 43:635–641CrossRefPubMed Michaely HJ, Attenberger UI, Dietrich O et al (2008) Feasibility of gadofosveset-enhanced steady-state magnetic resonance angiography of the peripheral vessels at 3 tesla with Dixon fat saturation. Invest Radiol 43:635–641CrossRefPubMed
32.
go back to reference Davenport MS, Caoili EM, Kaza RK, Hussain HK (2014) Matched within-patient cohort study of transient arterial phase respiratory motion-related artifact in MR imaging of the liver: gadoxetate disodium versus gadobenate dimeglumine. Radiology 272:123–131CrossRefPubMed Davenport MS, Caoili EM, Kaza RK, Hussain HK (2014) Matched within-patient cohort study of transient arterial phase respiratory motion-related artifact in MR imaging of the liver: gadoxetate disodium versus gadobenate dimeglumine. Radiology 272:123–131CrossRefPubMed
33.
go back to reference Kim SY, Park SH, Wu EH et al (2015) Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium: risk factor analyses. AJR Am J Roentgenol 204:1220–1227CrossRefPubMed Kim SY, Park SH, Wu EH et al (2015) Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium: risk factor analyses. AJR Am J Roentgenol 204:1220–1227CrossRefPubMed
Metadata
Title
Modified CAIPIRINHA-VIBE without view-sharing on gadoxetic acid–enhanced multi-arterial phase MR imaging for diagnosing hepatocellular carcinoma: comparison with the CAIPIRINHA-Dixon-TWIST-VIBE
Authors
Seung Baek Hong
Nam Kyung Lee
Suk Kim
Hyeong Il Seo
Hyun Sung Kim
Dong Uk Kim
Tae Un Kim
Hwa Seong Ryu
Publication date
01-07-2019
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 7/2019
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06095-x

Other articles of this Issue 7/2019

European Radiology 7/2019 Go to the issue