Localization of pacing and defibrillator leads using standard x-ray views is frequently inaccurate and is not reproducible

Authors: Larry R. Jackson II, Jonathan P. Piccini Sr., James P. Daubert, Lynne M. Hurwitz Koweek, Brett D. Atwater

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 1/2015

Login to get access

Abstract

Purpose

While the accuracy of roentography for evaluation of lead tip position compared with three-dimensional imaging techniques has been well described, there remains considerable variability in the interpretation of the reproducibility of standard x-ray for right ventricular (RV) and left ventricular (LV) lead position. The aim of this study was to evaluate the accuracy and reliability of right ventricular (RV) and left ventricular (LV) lead tip position as determined by board-certified cardiac electrophysiologists (EP) using standard x-ray views.

Methods

EP interpretations of RV and LV lead tip position using standard x-ray views (posterior-anterior, lateral, and left anterior oblique) were compared to thoracic computed tomography (CT). The accuracy of x-ray interpretation was compared to the reference CT location, and the reproducibility of x-ray interpretation was tested using the free-marginal Kappa statistic.

Results

A total of 58 EPs were invited to participate in the survey with a response rate of 43 % (25/58). The agreement between x-ray and CT lead tip position (accuracy) was 37 % for RV lead, 33 % for longitudinal LV lead, and 41 % for short axis LV lead. Reproducibility was 64 % for RV lead tip (k = 0.46), 58 % for longitudinal LV lead tip (k = 0.37), and 39 % for short axis LV lead tip (k = 0.24).

Conclusions

Conventional roentography is limited in its ability to accurately and reliably determine pacing lead tip position.
Literature
1.
go back to reference Burri, H., Domenichini, G., Sunthorn, H., Ganière, V., & Stettler, C. (2012). Comparison of tools and techniques for implanting pacemaker leads on the ventricular mid-septum. Europace, 14(6), 847–852.CrossRefPubMed Burri, H., Domenichini, G., Sunthorn, H., Ganière, V., & Stettler, C. (2012). Comparison of tools and techniques for implanting pacemaker leads on the ventricular mid-septum. Europace, 14(6), 847–852.CrossRefPubMed
2.
go back to reference Teh, A. W., Medi, C., Rosso, R., Lee, G., Gurvitch, R., & Mond, H. G. (2009). Pacing from the right ventricular septum: is there a danger to the coronary arteries? Pacing and Clinical Electrophysiology, 32(7), 894–897.CrossRefPubMed Teh, A. W., Medi, C., Rosso, R., Lee, G., Gurvitch, R., & Mond, H. G. (2009). Pacing from the right ventricular septum: is there a danger to the coronary arteries? Pacing and Clinical Electrophysiology, 32(7), 894–897.CrossRefPubMed
3.
go back to reference Ng, A. C. T., Allman, C., Vidaic, J., Tie, H., Hopkins, A. P., & Leung, D. Y. (2009). Long-term impact of right ventricular septal versus apical pacing on left ventricular synchrony and function in patients with second- or third-degree heart block. American Journal of Cardiology, 103(8), 1096–1101.CrossRefPubMed Ng, A. C. T., Allman, C., Vidaic, J., Tie, H., Hopkins, A. P., & Leung, D. Y. (2009). Long-term impact of right ventricular septal versus apical pacing on left ventricular synchrony and function in patients with second- or third-degree heart block. American Journal of Cardiology, 103(8), 1096–1101.CrossRefPubMed
4.
go back to reference Domenichini, G., Sunthorn, H., Fleury, E., Foulkes, H., Stettler, C., & Burri, H. (2012). Pacing of the interventricular septum versus the right ventricular apex: a prospective, randomized study. European Journal of Internal Medicine, 23(7), 621–627.CrossRefPubMed Domenichini, G., Sunthorn, H., Fleury, E., Foulkes, H., Stettler, C., & Burri, H. (2012). Pacing of the interventricular septum versus the right ventricular apex: a prospective, randomized study. European Journal of Internal Medicine, 23(7), 621–627.CrossRefPubMed
5.
go back to reference Singh, J. P., Klein, H. U., Huang, D. T., Reek, S., Kuniss, M., Quesada, A., et al. (2011). Left ventricular lead position and clinical outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) trial. Circulation, 123(11), 1159–1166.CrossRefPubMed Singh, J. P., Klein, H. U., Huang, D. T., Reek, S., Kuniss, M., Quesada, A., et al. (2011). Left ventricular lead position and clinical outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) trial. Circulation, 123(11), 1159–1166.CrossRefPubMed
6.
go back to reference Landis, J. R., & Koch, G. G. (1977). The measurement of observer agreement for categorical data. Biometrics, 33(1), 159–174.CrossRefPubMed Landis, J. R., & Koch, G. G. (1977). The measurement of observer agreement for categorical data. Biometrics, 33(1), 159–174.CrossRefPubMed
7.
go back to reference Osmancik, P., Stros, P., Herman, D., Curila, K., Petr, R. (2013) The insufficiency of left anterior oblique and the usefulness of right anterior oblique projection for correct localization of a CT-verified right ventricular lead into the midseptum. Circulation: Arrhythmia and Electrophysiology. Osmancik, P., Stros, P., Herman, D., Curila, K., Petr, R. (2013) The insufficiency of left anterior oblique and the usefulness of right anterior oblique projection for correct localization of a CT-verified right ventricular lead into the midseptum. Circulation: Arrhythmia and Electrophysiology.
8.
go back to reference Balt, J. C., van Hemel, N. M., Wellens, H. J. J., & de Voogt, W. G. (2010). Radiological and electrocardiographic characterization of right ventricular outflow tract pacing. Europace, 12(12), 1739–1744.CrossRefPubMed Balt, J. C., van Hemel, N. M., Wellens, H. J. J., & de Voogt, W. G. (2010). Radiological and electrocardiographic characterization of right ventricular outflow tract pacing. Europace, 12(12), 1739–1744.CrossRefPubMed
9.
go back to reference Tse, H.-F., & Lau, C.-P. (1997). Long-term effect of right ventricular pacing on myocardial perfusion and function. Journal of the American College of Cardiology, 29(4), 744–749.CrossRefPubMed Tse, H.-F., & Lau, C.-P. (1997). Long-term effect of right ventricular pacing on myocardial perfusion and function. Journal of the American College of Cardiology, 29(4), 744–749.CrossRefPubMed
10.
go back to reference Zhang, X.-H., Chen, H. U. A., Siu, C.-W., Yiu, K.-H., Chan, W.-S., Lee, K. L., et al. (2008). New-onset heart failure after permanent right ventricular apical pacing in patients with acquired high-grade atrioventricular block and normal left ventricular function. Journal of Cardiovascular Electrophysiology, 19(2), 136–141.CrossRefPubMed Zhang, X.-H., Chen, H. U. A., Siu, C.-W., Yiu, K.-H., Chan, W.-S., Lee, K. L., et al. (2008). New-onset heart failure after permanent right ventricular apical pacing in patients with acquired high-grade atrioventricular block and normal left ventricular function. Journal of Cardiovascular Electrophysiology, 19(2), 136–141.CrossRefPubMed
11.
go back to reference The, D. T. I. (2002). Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. Journal of the American Medical Association, 288(24), 3115–3123.CrossRef The, D. T. I. (2002). Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. Journal of the American Medical Association, 288(24), 3115–3123.CrossRef
12.
go back to reference Thébault, C., Donal, E., Meunier, C., Gervais, R., Gerritse, B., Gold, M. R., et al. (2012). Sites of left and right ventricular lead implantation and response to cardiac resynchronization therapy observations from the REVERSE trial. European Heart Journal, 33(21), 2662–2671.CrossRefPubMed Thébault, C., Donal, E., Meunier, C., Gervais, R., Gerritse, B., Gold, M. R., et al. (2012). Sites of left and right ventricular lead implantation and response to cardiac resynchronization therapy observations from the REVERSE trial. European Heart Journal, 33(21), 2662–2671.CrossRefPubMed
13.
go back to reference Khan, F. Z., Salahshouri, P., Duehmke, R., Read, P. A., Pugh, P. J., Elsik, M., et al. (2011). The impact of the right ventricular lead position on response to cardiac resynchronization therapy. Pacing and Clinical Electrophysiology, 34(4), 467–474.CrossRefPubMed Khan, F. Z., Salahshouri, P., Duehmke, R., Read, P. A., Pugh, P. J., Elsik, M., et al. (2011). The impact of the right ventricular lead position on response to cardiac resynchronization therapy. Pacing and Clinical Electrophysiology, 34(4), 467–474.CrossRefPubMed
14.
go back to reference Sade, L. E., Demir, O., Atar, I., Muderrisoglu, H., & Ozin, B. (2009). Effect of right ventricular pacing lead on left ventricular dyssynchrony in patients receiving cardiac resynchronization therapy. American Journal of Cardiology, 103(5), 695–700.CrossRefPubMed Sade, L. E., Demir, O., Atar, I., Muderrisoglu, H., & Ozin, B. (2009). Effect of right ventricular pacing lead on left ventricular dyssynchrony in patients receiving cardiac resynchronization therapy. American Journal of Cardiology, 103(5), 695–700.CrossRefPubMed
15.
go back to reference Rickard, J., Ingelmo, C., Sraow, D., Wilkoff, B. L., Grimm, R. A., Schoenhagen, P., et al. (2011). Chest radiography is a poor predictor of left ventricular lead position in patients undergoing cardiac resynchronization therapy: comparison with multidetector computed tomography. Journal of Interventional Cardiac Electrophysiology, 32(1), 59–65.CrossRefPubMed Rickard, J., Ingelmo, C., Sraow, D., Wilkoff, B. L., Grimm, R. A., Schoenhagen, P., et al. (2011). Chest radiography is a poor predictor of left ventricular lead position in patients undergoing cardiac resynchronization therapy: comparison with multidetector computed tomography. Journal of Interventional Cardiac Electrophysiology, 32(1), 59–65.CrossRefPubMed
16.
go back to reference Duckett, S. G., Ginks, M. R., Knowles, B. R., Ma, Y., Shetty, A., Bostock, J., et al. (2011). Advanced image fusion to overlay coronary sinus anatomy with real-time fluoroscopy to facilitate left ventricular lead implantation in CRT. Pacing and Clinical Electrophysiology, 34(2), 226–234.CrossRefPubMed Duckett, S. G., Ginks, M. R., Knowles, B. R., Ma, Y., Shetty, A., Bostock, J., et al. (2011). Advanced image fusion to overlay coronary sinus anatomy with real-time fluoroscopy to facilitate left ventricular lead implantation in CRT. Pacing and Clinical Electrophysiology, 34(2), 226–234.CrossRefPubMed
17.
go back to reference Blendea, D., Mansour, M., Shah, R. V., Chung, J., Nandigam, V., Heist, E. K., et al. (2007). Usefulness of high-speed rotational coronary venous angiography during cardiac resynchronization therapy. American Journal of Cardiology, 100(10), 1561–1565.CrossRefPubMed Blendea, D., Mansour, M., Shah, R. V., Chung, J., Nandigam, V., Heist, E. K., et al. (2007). Usefulness of high-speed rotational coronary venous angiography during cardiac resynchronization therapy. American Journal of Cardiology, 100(10), 1561–1565.CrossRefPubMed
18.
go back to reference Kumar, P., Blendea, D., Nandigam, V., Moore, S. A., Heist, E. K., & Singh, J. P. (2010). Assessment of the post-implant final left ventricular lead position: a comparative study between radiographic and angiographic modalities. Journal of Interventional Cardiac Electrophysiology, 29(1), 17–22.CrossRefPubMed Kumar, P., Blendea, D., Nandigam, V., Moore, S. A., Heist, E. K., & Singh, J. P. (2010). Assessment of the post-implant final left ventricular lead position: a comparative study between radiographic and angiographic modalities. Journal of Interventional Cardiac Electrophysiology, 29(1), 17–22.CrossRefPubMed
Metadata
Title
Localization of pacing and defibrillator leads using standard x-ray views is frequently inaccurate and is not reproducible
Authors
Larry R. Jackson II
Jonathan P. Piccini Sr.
James P. Daubert
Lynne M. Hurwitz Koweek
Brett D. Atwater
Publication date
01-06-2015
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2015
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-015-9984-5

Other articles of this Issue 1/2015

Journal of Interventional Cardiac Electrophysiology 1/2015 Go to the issue