Skip to main content
Top
Published in: Sports Medicine 12/2002

01-10-2002 | Review Article

Utility of Pedometers for Assessing Physical Activity

Convergent Validity

Authors: Catrine Tudor-Locke, Joel E. Williams, Jared P. Reis, Delores Pluto

Published in: Sports Medicine | Issue 12/2002

Login to get access

Abstract

Valid assessment of physical activity is important to researchers and practitioners interested in surveillance, screening, programme evaluation and intervention. The validity of an assessment instrument is commonly considered its most important attribute. Convergent validity is the extent to which an instrument’s output is associated with that of other instruments intended to measure the same exposure of interest. A systematic review of the literature produced 25 articles directly relevant to the question of convergent validity of pedometers against accelerometers, observation, and self-reported measures of physical activity. Reported correlations were pooled and a median r-value was computed. Pedometers correlate strongly (median r = 0.86) with different accelerometers (specifically uniaxial accelerometers) depending on the specific instruments used, monitoring frame and conditions implemented, and the manner in which the outputs are expressed. Pedometers also correlate strongly (median r = 0.82) with time in observed activity. Time in observed inactivity correlated negatively with pedometer outputs (median r = -0.44). The relationship with observed steps taken depended upon monitoring conditions and speed of walking. The highest agreement was apparent during ambulatory activity (running, walking) or during sitting (when both observation and pedometers would register few steps taken). There was consistent evidence of reduced accuracy during slow walking. Pedometers correlate moderately with different measures of energy expenditure (median r = 0.68). The relationship between pedometer outputs and energy expenditure is complicated by the use of many different direct and indirect measures of energy expenditure and population samples. Concordance with self-reported physical activity (median r = 0.33) varied depending upon the self-report instrument used, individuals assessed, and how pedometer outputs are expressed (e.g. steps, distance travelled, energy expenditure). Pedometer output has an inverse relationship with reported time spent sitting (r = -0.38). The accumulated evidence herein provides ample support that the simple and inexpensive pedometer is a valid option for assessing physical activity in research and practice.
Literature
1.
go back to reference Ainsworth BE, LaMonte MJ, Tudor-Locke C. Physical activity. In: Anderson R, editor. Obesity: etiology, assessment, treatment, and prevention. Champaign (IL): Human Kinetics. In press Ainsworth BE, LaMonte MJ, Tudor-Locke C. Physical activity. In: Anderson R, editor. Obesity: etiology, assessment, treatment, and prevention. Champaign (IL): Human Kinetics. In press
2.
go back to reference Montoye HJ, Taylor HL. Measurement of physical activity in population studies: a review. Hum Biol 1984; 56 (2): 195–216PubMed Montoye HJ, Taylor HL. Measurement of physical activity in population studies: a review. Hum Biol 1984; 56 (2): 195–216PubMed
3.
go back to reference Kriska AM, Casperson CJ. A collection of physical activity questionnaires for health-related research. Med Sci Sports Exerc 1997; 29 Suppl. 6: S1-S205 Kriska AM, Casperson CJ. A collection of physical activity questionnaires for health-related research. Med Sci Sports Exerc 1997; 29 Suppl. 6: S1-S205
4.
go back to reference Westerterp KR. Assessment of physical activity level in relation to obesity: current evidence and research issues. Med Sci Sports Exerc 1999; 31 Suppl. 11: S522-S5 Westerterp KR. Assessment of physical activity level in relation to obesity: current evidence and research issues. Med Sci Sports Exerc 1999; 31 Suppl. 11: S522-S5
5.
go back to reference Westerterp KR. Physical activity assessment with accelerometers. Int J Obes Relat Metab Disord 1999; 23 Suppl. 3: S45-S9CrossRef Westerterp KR. Physical activity assessment with accelerometers. Int J Obes Relat Metab Disord 1999; 23 Suppl. 3: S45-S9CrossRef
6.
go back to reference Tudor-Locke CE, Myers AM. Challenges and opportunities for measuring physical activity in sedentary adults. Sports Med 2001; 31 (312): 91–100PubMedCrossRef Tudor-Locke CE, Myers AM. Challenges and opportunities for measuring physical activity in sedentary adults. Sports Med 2001; 31 (312): 91–100PubMedCrossRef
7.
go back to reference Rowlands AV, Eston RG, Ingledew EK. Measurement of physical activity in children with particular reference to the use of heart rate and pedometry. Sports Med 1997; 24 (4): 258–72PubMedCrossRef Rowlands AV, Eston RG, Ingledew EK. Measurement of physical activity in children with particular reference to the use of heart rate and pedometry. Sports Med 1997; 24 (4): 258–72PubMedCrossRef
8.
go back to reference Sequeira MM, Rickenbach M, Wietlisbach V, et al. Physical activity assessment using a pedometer and its comparison with a questionnaire in a large population survey. Am J Epidemiol 1995; 142 (9): 989–99PubMed Sequeira MM, Rickenbach M, Wietlisbach V, et al. Physical activity assessment using a pedometer and its comparison with a questionnaire in a large population survey. Am J Epidemiol 1995; 142 (9): 989–99PubMed
9.
go back to reference Mahar MT, Ainsworth BE. Measurement of physical activity: the Cooper Institute Conference Series. Res Q Exerc Sport 2000; 71 Suppl. 2: S1-S158 Mahar MT, Ainsworth BE. Measurement of physical activity: the Cooper Institute Conference Series. Res Q Exerc Sport 2000; 71 Suppl. 2: S1-S158
10.
go back to reference Raven PB, Perrel AW, Robertson DM, et al. Measurement of moderate physical activity: advances in assessment techniques. Med Sci Sports Exerc 2000; 33 Suppl. 9: S439–516 Raven PB, Perrel AW, Robertson DM, et al. Measurement of moderate physical activity: advances in assessment techniques. Med Sci Sports Exerc 2000; 33 Suppl. 9: S439–516
11.
go back to reference Freedson PS, Melanson E, Sirard J. Calibration of the Computer Science Applications Inc. accelerometer. Med Sci Sports Exerc 1998; 30 (5): 777–81PubMedCrossRef Freedson PS, Melanson E, Sirard J. Calibration of the Computer Science Applications Inc. accelerometer. Med Sci Sports Exerc 1998; 30 (5): 777–81PubMedCrossRef
12.
go back to reference Welk GJ, Corbin CB, Dale D. Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 2000; 71 Suppl. 2: 59–73 Welk GJ, Corbin CB, Dale D. Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 2000; 71 Suppl. 2: 59–73
13.
go back to reference Welk GJ, Differding JA, Thompson RW, et al. The utility of the Digi-walker step counter to assess daily physical activity patterns. Med Sci Sports Exerc 2000; 32 (9): S481-S8 Welk GJ, Differding JA, Thompson RW, et al. The utility of the Digi-walker step counter to assess daily physical activity patterns. Med Sci Sports Exerc 2000; 32 (9): S481-S8
14.
go back to reference Bassett DR. Validity and reliability issues in objective monitoring of physical activity. Res Q Exerc Sport 2000; 71 (2): 30–6 Bassett DR. Validity and reliability issues in objective monitoring of physical activity. Res Q Exerc Sport 2000; 71 (2): 30–6
15.
go back to reference Freedson PS, Miller K. Objective monitoring of physical activity using motion sensors and heart rate. Res Q Exerc Sport 2000; 71 (2): 21–9 Freedson PS, Miller K. Objective monitoring of physical activity using motion sensors and heart rate. Res Q Exerc Sport 2000; 71 (2): 21–9
16.
go back to reference Tudor-Locke CE, Myers AM. Methodological considerations for researchers and practitioners using pedometers tomeasure physical (ambulatory) activity. Res Q Exerc Sport 2001; 72 (1): 1–12PubMed Tudor-Locke CE, Myers AM. Methodological considerations for researchers and practitioners using pedometers tomeasure physical (ambulatory) activity. Res Q Exerc Sport 2001; 72 (1): 1–12PubMed
17.
go back to reference Campbell DT, Fiske DW. Convergent and discriminant validation by the multitrait-multi method matrix. Psychol Bull 1959; 56: 80–105CrossRef Campbell DT, Fiske DW. Convergent and discriminant validation by the multitrait-multi method matrix. Psychol Bull 1959; 56: 80–105CrossRef
18.
go back to reference Windsor R, Baranowski T, Clark N, et al. Evaluation of health promotion, health education, and disease prevention programs. 2nd ed. Mountain view (CA): Mayfield Publishing Company, 1994 Windsor R, Baranowski T, Clark N, et al. Evaluation of health promotion, health education, and disease prevention programs. 2nd ed. Mountain view (CA): Mayfield Publishing Company, 1994
19.
go back to reference Ainsworth BE, Sternfeld B, Slattery ML, et al. Physical activity and breast cancer: evaluation of physical activity assessment methods. Cancer 1998; 83 (3): 611–20PubMedCrossRef Ainsworth BE, Sternfeld B, Slattery ML, et al. Physical activity and breast cancer: evaluation of physical activity assessment methods. Cancer 1998; 83 (3): 611–20PubMedCrossRef
20.
go back to reference Bassett DR, Strath SJ. Use of pedometers in assessing physical activity. In: Welk G, Dale D, editors. Physical activity assessments for health-related research. Champaign (IL): Human Kinetics. In press Bassett DR, Strath SJ. Use of pedometers in assessing physical activity. In: Welk G, Dale D, editors. Physical activity assessments for health-related research. Champaign (IL): Human Kinetics. In press
21.
go back to reference Gardner AW, Poehlman ET. Assessment of free-living daily physical activity in older claudicants: validation against the doubly labeled water technique. J Gerontol Med Sci 1998; 53A (4): M275-M80CrossRef Gardner AW, Poehlman ET. Assessment of free-living daily physical activity in older claudicants: validation against the doubly labeled water technique. J Gerontol Med Sci 1998; 53A (4): M275-M80CrossRef
22.
go back to reference Kilanowski CK, Consalvi AR, Epstein LH. Validation of an electronic pedometer for measurement of physical activity in children. Pediatr Exerc Sci 1999; 11: 63–8 Kilanowski CK, Consalvi AR, Epstein LH. Validation of an electronic pedometer for measurement of physical activity in children. Pediatr Exerc Sci 1999; 11: 63–8
23.
go back to reference Leenders NYJM, Sherman WM, Nagaraja HN. Comparisons of four methods of estimating physical activity in adult women. Med Sci Sports Exerc 2000; 32 (7): 1320–6CrossRef Leenders NYJM, Sherman WM, Nagaraja HN. Comparisons of four methods of estimating physical activity in adult women. Med Sci Sports Exerc 2000; 32 (7): 1320–6CrossRef
24.
go back to reference Schmalzried TP, Shepherd EF, Dorey FJ, et al. Wear is a function of use, not time. Clin Ortho Rel Res 2000; 381: 36–46CrossRef Schmalzried TP, Shepherd EF, Dorey FJ, et al. Wear is a function of use, not time. Clin Ortho Rel Res 2000; 381: 36–46CrossRef
25.
go back to reference Bassett DR, Ainsworth BE, Swartz AM, et al. Validity of four motion sensors in measuring moderate intensity physical activity. Med Sci Sports Exerc 2000; 32 Suppl. 9: S471–80 Bassett DR, Ainsworth BE, Swartz AM, et al. Validity of four motion sensors in measuring moderate intensity physical activity. Med Sci Sports Exerc 2000; 32 Suppl. 9: S471–80
26.
go back to reference Leenders NYJM, Sherman WM, Nagaraja HN, et al. Evaluation of methods to assess physical activity in free-living conditions. Med Sci Sports Exerc 2001; 33 (7): 1233–40PubMed Leenders NYJM, Sherman WM, Nagaraja HN, et al. Evaluation of methods to assess physical activity in free-living conditions. Med Sci Sports Exerc 2001; 33 (7): 1233–40PubMed
27.
go back to reference Nishikido N, Kashiwazaki H, Suzuki T. Preschool children’s daily activities: direct observation, pedometry or questionnaire. J Hum Ergol (Tokyo) 1982; 11: 214–8 Nishikido N, Kashiwazaki H, Suzuki T. Preschool children’s daily activities: direct observation, pedometry or questionnaire. J Hum Ergol (Tokyo) 1982; 11: 214–8
28.
go back to reference Hoodless DJ, Stainer K, Savic N, et al. Reduced customary activity in chronic heart failure: assessment with a new shoe mounted pedometer. Int J Cardiol 1994; 43 (1): 39–42PubMedCrossRef Hoodless DJ, Stainer K, Savic N, et al. Reduced customary activity in chronic heart failure: assessment with a new shoe mounted pedometer. Int J Cardiol 1994; 43 (1): 39–42PubMedCrossRef
29.
go back to reference Selin K, Winkel J, Stockholm MUSIC 1 Study Group. Evaluation of two instruments for recording sitting and standing postures and number of foot steps. Appl Ergon 1994; 25 (1): 503–10CrossRef Selin K, Winkel J, Stockholm MUSIC 1 Study Group. Evaluation of two instruments for recording sitting and standing postures and number of foot steps. Appl Ergon 1994; 25 (1): 503–10CrossRef
30.
go back to reference Bassett DR, Ainsworth BE, Leggett SR, et al. Accuracy of five electronic pedometers for measuring distance walked. Med Sci Sports Exerc 1996; 28 (8): 1071–7PubMedCrossRef Bassett DR, Ainsworth BE, Leggett SR, et al. Accuracy of five electronic pedometers for measuring distance walked. Med Sci Sports Exerc 1996; 28 (8): 1071–7PubMedCrossRef
31.
go back to reference Schmalzried TP, Szuszczewicz ES, Northfield MR, et al. Quantitative assessment of walking activity after total hip or knee replacement. J Bone Joint Surg Am 1998; 80 (1): 54–9PubMedCrossRef Schmalzried TP, Szuszczewicz ES, Northfield MR, et al. Quantitative assessment of walking activity after total hip or knee replacement. J Bone Joint Surg Am 1998; 80 (1): 54–9PubMedCrossRef
32.
go back to reference Shepherd EF, Toloza E, McClung CD, et al. Step activity monitor: increased accuracy in quantifying ambulatory activity. J Orthop Res 1999; 17 (5): 703–8PubMedCrossRef Shepherd EF, Toloza E, McClung CD, et al. Step activity monitor: increased accuracy in quantifying ambulatory activity. J Orthop Res 1999; 17 (5): 703–8PubMedCrossRef
33.
go back to reference Hendelman D, Miller K, Baggett C, et al. Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Med Sci Sports Exerc 2000; 32 (9): S442–50 Hendelman D, Miller K, Baggett C, et al. Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Med Sci Sports Exerc 2000; 32 (9): S442–50
34.
go back to reference Kashiwazaki H, Inaoka T, Suzuki T, et al. Correlations of pedometer readings with energy expenditure in workers during free-living daily activities. Euro J Appl Physiol Occup Physiol 1986; 54 (6): 585–90CrossRef Kashiwazaki H, Inaoka T, Suzuki T, et al. Correlations of pedometer readings with energy expenditure in workers during free-living daily activities. Euro J Appl Physiol Occup Physiol 1986; 54 (6): 585–90CrossRef
35.
go back to reference Irimagawa S, Imamiya S-I. Industrial hygienic study on nursing activities comparison of energy expenditure between pedometer and Holter electrocardiograph. Kitasato Arch Exp Med 1993; 65: 99–105PubMed Irimagawa S, Imamiya S-I. Industrial hygienic study on nursing activities comparison of energy expenditure between pedometer and Holter electrocardiograph. Kitasato Arch Exp Med 1993; 65: 99–105PubMed
36.
go back to reference Eston RG, Rowlands AV, Ingledew DK. Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children’s activities. J Appl Physiol 1998; 84: 362–71PubMed Eston RG, Rowlands AV, Ingledew DK. Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children’s activities. J Appl Physiol 1998; 84: 362–71PubMed
37.
go back to reference Fogelholm M, Hiilloskorpi H, Laukkanen R, et al. Assessment of energy expenditure in overweight women. Med Sci Sports Exerc 1998; 30 (8): 1191–7PubMedCrossRef Fogelholm M, Hiilloskorpi H, Laukkanen R, et al. Assessment of energy expenditure in overweight women. Med Sci Sports Exerc 1998; 30 (8): 1191–7PubMedCrossRef
38.
go back to reference Edelman B, Smits G. The pedometer: a reassessment of its usefulness in the measurement of activity level. Percept Mot Skills 1984; 58: 151–8CrossRef Edelman B, Smits G. The pedometer: a reassessment of its usefulness in the measurement of activity level. Percept Mot Skills 1984; 58: 151–8CrossRef
39.
go back to reference Feller JA, Kay PR, Hodgkinson JP, et al. Activity and socket wear in the Charnley low-friction arthroplasty. J Arthroplasty 1994; 9 (4): 341–5PubMedCrossRef Feller JA, Kay PR, Hodgkinson JP, et al. Activity and socket wear in the Charnley low-friction arthroplasty. J Arthroplasty 1994; 9 (4): 341–5PubMedCrossRef
40.
go back to reference Shaukat N, Douglas JT, Bennett JL, et al. Can physical activity explain the differences in insulin levels and fibrinolytic activity between young Indo-origin and European relatives of patients with coronary heart disease? Fibrinolysis 1995; 9: 55–63CrossRef Shaukat N, Douglas JT, Bennett JL, et al. Can physical activity explain the differences in insulin levels and fibrinolytic activity between young Indo-origin and European relatives of patients with coronary heart disease? Fibrinolysis 1995; 9: 55–63CrossRef
41.
go back to reference Zahiri CA, Schmalzried TP, Szuszczewicz ES, et al. Assessing activity in joint replacement patients. J Arthroplasty 1998; 13 (8): 890–5PubMedCrossRef Zahiri CA, Schmalzried TP, Szuszczewicz ES, et al. Assessing activity in joint replacement patients. J Arthroplasty 1998; 13 (8): 890–5PubMedCrossRef
42.
go back to reference Narring F, Cauderay M, Cavadini C, et al. Physical fitness and sport activity of children and adolescents: methodological aspects of a regional survey. Soz Praventivmed 1999; 44 (2): 44–54PubMedCrossRef Narring F, Cauderay M, Cavadini C, et al. Physical fitness and sport activity of children and adolescents: methodological aspects of a regional survey. Soz Praventivmed 1999; 44 (2): 44–54PubMedCrossRef
43.
go back to reference Bassett DR, Cureton AL, Ainsworth BE. Measurement of daily walking distance: questionnaire versus pedometer. Med Sci Sports Exerc 2000; 32 (5): 1018–23PubMed Bassett DR, Cureton AL, Ainsworth BE. Measurement of daily walking distance: questionnaire versus pedometer. Med Sci Sports Exerc 2000; 32 (5): 1018–23PubMed
44.
go back to reference Singh PN, Fraser GE, Knutsen SF, et al. Validity of a physical activity questionnaire among African-American Seventh- Day Adventists. Med Sci Sports Exerc 2001; 33 (3): 468–75PubMedCrossRef Singh PN, Fraser GE, Knutsen SF, et al. Validity of a physical activity questionnaire among African-American Seventh- Day Adventists. Med Sci Sports Exerc 2001; 33 (3): 468–75PubMedCrossRef
45.
go back to reference Hatano Y. Prevalence and use of pedometer [in Japanese]. Res J Walk 1997; 1: 45–54 Hatano Y. Prevalence and use of pedometer [in Japanese]. Res J Walk 1997; 1: 45–54
46.
go back to reference Wilcox S, Tudor-Locke CE, Ainsworth BE. Physical activity patterns, assessment, and motivation in older adults. In: Shephard RJ, editor. Gender, physical activity and aging. Boca Raton (FL): CRC Press, 2002: 513–39 Wilcox S, Tudor-Locke CE, Ainsworth BE. Physical activity patterns, assessment, and motivation in older adults. In: Shephard RJ, editor. Gender, physical activity and aging. Boca Raton (FL): CRC Press, 2002: 513–39
47.
go back to reference McClung CD, Zahiri CA, Higa JK, et al. Relationship between body mass index and activity in hip or knee arthroplasty patients. J Orthop Res 2000; 18 (1): 35–9PubMedCrossRef McClung CD, Zahiri CA, Higa JK, et al. Relationship between body mass index and activity in hip or knee arthroplasty patients. J Orthop Res 2000; 18 (1): 35–9PubMedCrossRef
48.
go back to reference Montoye HJ, Kemper HCG, Saris WHM, et al. Measuring physical activity and energy expenditure. Champaign (IL): Human Kinetics, 1996 Montoye HJ, Kemper HCG, Saris WHM, et al. Measuring physical activity and energy expenditure. Champaign (IL): Human Kinetics, 1996
49.
go back to reference Sallis JF, Saelens BE. Assessment of physical activity by self-report: status, limitations, and future directions. Res Q Exerc Sport 2000; 71 (2): 1–14 Sallis JF, Saelens BE. Assessment of physical activity by self-report: status, limitations, and future directions. Res Q Exerc Sport 2000; 71 (2): 1–14
Metadata
Title
Utility of Pedometers for Assessing Physical Activity
Convergent Validity
Authors
Catrine Tudor-Locke
Joel E. Williams
Jared P. Reis
Delores Pluto
Publication date
01-10-2002
Publisher
Springer International Publishing
Published in
Sports Medicine / Issue 12/2002
Print ISSN: 0112-1642
Electronic ISSN: 1179-2035
DOI
https://doi.org/10.2165/00007256-200232120-00004