Abstract

Background

More than one-third of American adults are obese, and an elevated body mass index (BMI) is postulated to reduce the sensitivity of the clinical evaluation of the axilla. Clinical nodal examination is important in allocating breast cancer patients to appropriate axillary management. This study sought to determine whether BMI influences the rate of nodal positivity in women designated clinically as node-negative (cN0) by physical examination.

Methods

Breast cancer patients deemed cN0 who underwent sentinel lymph node biopsy (SLNB) from February 2006 to December 2011 were identified from a prospectively maintained database. Clinicopathologic features including BMI and axillary surgery results were recorded and compared among pathologically node-negative and node-positive patients.

Results

Overall, 5142 cN0 patients underwent 5262 SLNB procedures during the study period. Nearly one-third of the patients (28 %) were obese (BMI, >30 kg/m2). A positive SLN was identified in 25 % of the patients, and 84 % proceeded to axillary lymph node dissection. Predictors of SLN positivity included younger age, larger tumor size, high nuclear grade, multifocality, and lymphovascular invasion. An increased BMI did not correlate with a higher likelihood of SLN positivity (p = 0.6). The likelihood of cN0 patients having a high burden of axillary metastases (>3 positive nodes) was 4 % overall and, similarly, did not differ according to BMI (p = 0.4).

Conclusion

Elevated BMI was not associated with a higher likelihood of SLN positivity or heavy nodal disease burden among women staged as cN0 by physical exam. These findings indicate that physical examination is appropriate and sufficient for preoperative axillary evaluation of women undergoing initial surgery regardless of patient BMI.
Literature
1.
go back to reference Payne WS, Taylor WF, Khonsari S, Snider JH, Harrison EG Jr, Golenzer H, et al. Surgical treatment of breast cancer: trends and factors affecting survival. Arch Surg. 1970;101:105–13.CrossRefPubMed Payne WS, Taylor WF, Khonsari S, Snider JH, Harrison EG Jr, Golenzer H, et al. Surgical treatment of breast cancer: trends and factors affecting survival. Arch Surg. 1970;101:105–13.CrossRefPubMed
2.
go back to reference Krag DN, Anderson SJ, Julian TB, Brown AM, Harlow SP, Costantino JP, et al. Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trial. Lancet Oncol. 2010;11:927–33.CrossRefPubMedPubMedCentral Krag DN, Anderson SJ, Julian TB, Brown AM, Harlow SP, Costantino JP, et al. Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trial. Lancet Oncol. 2010;11:927–33.CrossRefPubMedPubMedCentral
3.
go back to reference Veronesi U, Paganelli G, Viale G, Luini A, Zurrida S, Galimberti V, et al. Sentinel-lymph-node biopsy as a staging procedure in breast cancer: update of a randomised controlled study. Lancet Oncol. 2006;7:983–90.CrossRefPubMed Veronesi U, Paganelli G, Viale G, Luini A, Zurrida S, Galimberti V, et al. Sentinel-lymph-node biopsy as a staging procedure in breast cancer: update of a randomised controlled study. Lancet Oncol. 2006;7:983–90.CrossRefPubMed
4.
go back to reference Galimberti V, Cole BF, Zurrida S, Viale G, Luini A, Veronesi P, et al. Axillary dissection versus no axillary dissection in patients with sentinel-node micrometastases (IBCSG 23-01): a phase 3 randomised controlled trial. Lancet Oncol. 2013;14:297–305.CrossRefPubMedPubMedCentral Galimberti V, Cole BF, Zurrida S, Viale G, Luini A, Veronesi P, et al. Axillary dissection versus no axillary dissection in patients with sentinel-node micrometastases (IBCSG 23-01): a phase 3 randomised controlled trial. Lancet Oncol. 2013;14:297–305.CrossRefPubMedPubMedCentral
5.
go back to reference Giuliano AE, Hunt KK, Ballman KV, Beitsch PD, Whitworth PW, Blumencranz PW, et al. Axillary dissection vs no axillary dissection in women with invasive breast cancer and sentinel node metastasis: a randomized clinical trial. JAMA. 2011;305:569–75.CrossRefPubMed Giuliano AE, Hunt KK, Ballman KV, Beitsch PD, Whitworth PW, Blumencranz PW, et al. Axillary dissection vs no axillary dissection in women with invasive breast cancer and sentinel node metastasis: a randomized clinical trial. JAMA. 2011;305:569–75.CrossRefPubMed
6.
go back to reference Sola M, Alberro JA, Fraile M, Santesteban P, Ramos M, Fabregas R, et al. Complete axillary lymph node dissection versus clinical follow-up in breast cancer patients with sentinel node micrometastasis: final results from the multicenter clinical trial AATRM 048/13/2000. Ann Surg Oncol. 2013;20:120–7.CrossRefPubMed Sola M, Alberro JA, Fraile M, Santesteban P, Ramos M, Fabregas R, et al. Complete axillary lymph node dissection versus clinical follow-up in breast cancer patients with sentinel node micrometastasis: final results from the multicenter clinical trial AATRM 048/13/2000. Ann Surg Oncol. 2013;20:120–7.CrossRefPubMed
7.
go back to reference Wang Z, Wu LC, Chen JQ. Sentinel lymph node biopsy compared with axillary lymph node dissection in early breast cancer: a meta-analysis. Breast Cancer Res Treat. 2011;129:675–89.CrossRefPubMed Wang Z, Wu LC, Chen JQ. Sentinel lymph node biopsy compared with axillary lymph node dissection in early breast cancer: a meta-analysis. Breast Cancer Res Treat. 2011;129:675–89.CrossRefPubMed
8.
go back to reference Saadatmand S, Bretveld R, Siesling S, Tilanus-Linthorst MM. Influence of tumour stage at breast cancer detection on survival in modern times: population based study in 173,797 patients. BMJ. 2015;351:h4901.CrossRefPubMedPubMedCentral Saadatmand S, Bretveld R, Siesling S, Tilanus-Linthorst MM. Influence of tumour stage at breast cancer detection on survival in modern times: population based study in 173,797 patients. BMJ. 2015;351:h4901.CrossRefPubMedPubMedCentral
9.
go back to reference Majid S, Tengrup I, Manjer J. Clinical assessment of axillary lymph nodes and tumor size in breast cancer compared with histopathological examination: a population-based analysis of 2537 women. World J Surg. 2013;37:67–71.CrossRefPubMed Majid S, Tengrup I, Manjer J. Clinical assessment of axillary lymph nodes and tumor size in breast cancer compared with histopathological examination: a population-based analysis of 2537 women. World J Surg. 2013;37:67–71.CrossRefPubMed
10.
go back to reference Donker M, van Tienhoven G, Straver ME, Meijnen P, van de Velde CJ, Mansel RE, et al. Radiotherapy or surgery of the axilla after a positive sentinel node in breast cancer (EORTC 10981-22023 AMAROS): a randomised, multicentre, open-label, phase 3 non-inferiority trial. Lancet Oncol. 2014;15:1303–10.CrossRefPubMedPubMedCentral Donker M, van Tienhoven G, Straver ME, Meijnen P, van de Velde CJ, Mansel RE, et al. Radiotherapy or surgery of the axilla after a positive sentinel node in breast cancer (EORTC 10981-22023 AMAROS): a randomised, multicentre, open-label, phase 3 non-inferiority trial. Lancet Oncol. 2014;15:1303–10.CrossRefPubMedPubMedCentral
11.
go back to reference Weaver DL, Ashikaga T, Krag DN, Skelly JM, Anderson SJ, Harlow SP, et al. Effect of occult metastases on survival in node-negative breast cancer. N Engl J Med. 2011;364:412–21.CrossRefPubMedPubMedCentral Weaver DL, Ashikaga T, Krag DN, Skelly JM, Anderson SJ, Harlow SP, et al. Effect of occult metastases on survival in node-negative breast cancer. N Engl J Med. 2011;364:412–21.CrossRefPubMedPubMedCentral
12.
go back to reference Dengel LT, Van Zee KJ, King TA, Stempel M, Cody HS, El-Tamer M, et al. Axillary dissection can be avoided in the majority of clinically node-negative patients undergoing breast-conserving therapy. Ann Surg Oncol. 2014;21:22–7.CrossRefPubMed Dengel LT, Van Zee KJ, King TA, Stempel M, Cody HS, El-Tamer M, et al. Axillary dissection can be avoided in the majority of clinically node-negative patients undergoing breast-conserving therapy. Ann Surg Oncol. 2014;21:22–7.CrossRefPubMed
13.
14.
go back to reference Fink HA, Lederle FA, Roth CS, Bowles CA, Nelson DB, Haas MA. The accuracy of physical examination to detect abdominal aortic aneurysm. Arch Intern Med. 2000;160:833–6.CrossRefPubMed Fink HA, Lederle FA, Roth CS, Bowles CA, Nelson DB, Haas MA. The accuracy of physical examination to detect abdominal aortic aneurysm. Arch Intern Med. 2000;160:833–6.CrossRefPubMed
15.
go back to reference Derossis AM, Fey JV, Cody HS III, Borgen PI. Obesity influences outcome of sentinel lymph node biopsy in early-stage breast cancer. J Am Coll Surg. 2003;197:896–901.CrossRefPubMed Derossis AM, Fey JV, Cody HS III, Borgen PI. Obesity influences outcome of sentinel lymph node biopsy in early-stage breast cancer. J Am Coll Surg. 2003;197:896–901.CrossRefPubMed
16.
go back to reference Goyal A, Newcombe RG, Chhabra A, Mansel RE. Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer–results of the ALMANAC validation phase. Breast Cancer Res Treat. 2006;99:203–8.CrossRefPubMed Goyal A, Newcombe RG, Chhabra A, Mansel RE. Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer–results of the ALMANAC validation phase. Breast Cancer Res Treat. 2006;99:203–8.CrossRefPubMed
18.
go back to reference Rao R, Euhus D, Mayo HG, Balch C. Axillary node interventions in breast cancer: a systematic review. JAMA. 2013;310:1385–94.CrossRefPubMed Rao R, Euhus D, Mayo HG, Balch C. Axillary node interventions in breast cancer: a systematic review. JAMA. 2013;310:1385–94.CrossRefPubMed
19.
go back to reference Mansel RE, Fallowfield L, Kissin M, Goyal A, Newcombe RG, Dixon JM, et al. Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial. J Natl Cancer Inst. 2006;98:599–609.CrossRefPubMed Mansel RE, Fallowfield L, Kissin M, Goyal A, Newcombe RG, Dixon JM, et al. Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial. J Natl Cancer Inst. 2006;98:599–609.CrossRefPubMed
20.
go back to reference Cox CE, Dupont E, Whitehead GF, Ebert MD, Nguyen K, Peltz ES, et al. Age and body mass index may increase the chance of failure in sentinel lymph node biopsy for women with breast cancer. Breast J. 2002;8:88–91.CrossRefPubMed Cox CE, Dupont E, Whitehead GF, Ebert MD, Nguyen K, Peltz ES, et al. Age and body mass index may increase the chance of failure in sentinel lymph node biopsy for women with breast cancer. Breast J. 2002;8:88–91.CrossRefPubMed
21.
go back to reference Diepstraten SC, Sever AR, Buckens CF, Veldhuis WB, van Dalen T, van den Bosch MA, et al. Value of preoperative ultrasound-guided axillary lymph node biopsy for preventing completion axillary lymph node dissection in breast cancer: a systematic review and meta-analysis. Ann Surg Oncol. 2014;21:51–9.CrossRefPubMed Diepstraten SC, Sever AR, Buckens CF, Veldhuis WB, van Dalen T, van den Bosch MA, et al. Value of preoperative ultrasound-guided axillary lymph node biopsy for preventing completion axillary lymph node dissection in breast cancer: a systematic review and meta-analysis. Ann Surg Oncol. 2014;21:51–9.CrossRefPubMed
22.
go back to reference Pilewskie M, Jochelson M, Gooch JC, Patil S, Stempel M, Morrow M. Is preoperative axillary imaging beneficial in identifying clinically node-negative patients requiring axillary lymph node dissection? J Am Coll Surg. 2016;222:138–45.CrossRefPubMed Pilewskie M, Jochelson M, Gooch JC, Patil S, Stempel M, Morrow M. Is preoperative axillary imaging beneficial in identifying clinically node-negative patients requiring axillary lymph node dissection? J Am Coll Surg. 2016;222:138–45.CrossRefPubMed
23.
go back to reference Pilewskie M, Mautner SK, Stempel M, Eaton A, Morrow M. Does a positive axillary lymph node needle biopsy result predict the need for an axillary lymph node dissection in clinically node-negative breast cancer patients in the ACOSOG Z0011 era? Ann Surg Oncol. 2016;23:1123–8.CrossRefPubMed Pilewskie M, Mautner SK, Stempel M, Eaton A, Morrow M. Does a positive axillary lymph node needle biopsy result predict the need for an axillary lymph node dissection in clinically node-negative breast cancer patients in the ACOSOG Z0011 era? Ann Surg Oncol. 2016;23:1123–8.CrossRefPubMed
24.
go back to reference Choi JS, Kim MJ, Moon HJ, Kim EK, Yoon JH. False-negative results of preoperative axillary ultrasound in patients with invasive breast cancer: correlations with clinicopathologic findings. Ultrasound Med Biol. 2012;38:1881–6.CrossRefPubMed Choi JS, Kim MJ, Moon HJ, Kim EK, Yoon JH. False-negative results of preoperative axillary ultrasound in patients with invasive breast cancer: correlations with clinicopathologic findings. Ultrasound Med Biol. 2012;38:1881–6.CrossRefPubMed
25.
go back to reference Garcia Fernandez A, Fraile M, Gimenez N, Rene A, Torras M, Canales L, et al. Use of axillary ultrasound, ultrasound-fine-needle aspiration biopsy, and magnetic resonance imaging in the preoperative triage of breast cancer patients considered for sentinel node biopsy. Ultrasound Med Biol. 2011;37:16–22.CrossRefPubMed Garcia Fernandez A, Fraile M, Gimenez N, Rene A, Torras M, Canales L, et al. Use of axillary ultrasound, ultrasound-fine-needle aspiration biopsy, and magnetic resonance imaging in the preoperative triage of breast cancer patients considered for sentinel node biopsy. Ultrasound Med Biol. 2011;37:16–22.CrossRefPubMed
26.
go back to reference Shah AR, Glazebrook KN, Boughey JC, Hoskin TL, Shah SS, Bergquist JR, et al. Does BMI affect the accuracy of preoperative axillary ultrasound in breast cancer patients? Ann Surg Oncol. 2014;21:3278–83.CrossRefPubMed Shah AR, Glazebrook KN, Boughey JC, Hoskin TL, Shah SS, Bergquist JR, et al. Does BMI affect the accuracy of preoperative axillary ultrasound in breast cancer patients? Ann Surg Oncol. 2014;21:3278–83.CrossRefPubMed
Metadata
Title
Impact of Body Mass Index on Clinical Axillary Nodal Assessment in Breast Cancer Patients
Authors
Damian McCartan, MD
Michelle Stempel, MPH
Anne Eaton, MS
Monica Morrow, MD
Melissa Pilewskie, MD
Publication date
01-10-2016
Publisher
Springer International Publishing
Published in
Annals of Surgical Oncology / Issue 10/2016
Print ISSN: 1068-9265
Electronic ISSN: 1534-4681
DOI
https://doi.org/10.1245/s10434-016-5330-0

Other articles of this Issue 10/2016

Annals of Surgical Oncology 10/2016 Go to the issue