Skip to main content
Top
Published in: International Journal of Implant Dentistry 1/2021

Open Access 01-12-2021 | Silicone | Research

Accuracy of guided surgery using the silicon impression and digital impression method for the mandibular free end: a comparative study

Authors: Koudai Nagata, Kei Fuchigami, Noriyuki Hoshi, Mihoko Atsumi, Katsuhiko Kimoto, Hiromasa Kawana

Published in: International Journal of Implant Dentistry | Issue 1/2021

Login to get access

Abstract

Background

Implant treatment using guided surgery is becoming widespread in clinical dental practice. Furthermore, the development of digital technology has enabled the use of intraoral scanners (IOSs) to fabricate surgical guide plates. The objective of this study was to compare the accuracy of guided surgery using the silicone impression method with a three-dimensional (3D) scanner and the digital impression method with IOS for one side of the mandibular free end. In addition, we compared the accuracy of tooth-supported vs tooth/mucosa-supported surgical guide plates.

Results

The accuracy of the tooth-supported surgical guide plate using the new IOS method instead of the method of obtaining impressions with conventional silicone resulted in better measurements of 3D deviation at the crest, 3D deviation at the apex, and angular deviation. In terms of the accuracy of the tooth/mucosa-supported surgical guide plate, there were no significant differences in all measurements. The surgical guide plate using an IOS and the tooth/mucosa-supported surgical guide plate may enable more accurate guided surgery.

Conclusion

Tooth/mucosa-supported guided surgery involving preparation with an IOS may result in more accurate implant surgery.
Literature
1.
go back to reference Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants. 2009;24:234–42.PubMed Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants. 2009;24:234–42.PubMed
2.
go back to reference Joda T, Derksen W, Wittneben JG, Kuehl S. Static computer-aided implant surgery (s-CAIS) analysing patient-reported outcome measures (PROMs), economics and surgical complications: a systematic review. Clin Oral Implants Res. 2018;29:359–73.CrossRef Joda T, Derksen W, Wittneben JG, Kuehl S. Static computer-aided implant surgery (s-CAIS) analysing patient-reported outcome measures (PROMs), economics and surgical complications: a systematic review. Clin Oral Implants Res. 2018;29:359–73.CrossRef
3.
go back to reference Monaco C, Arena A, Corsaletti L, Santomauro V, Venezia P. 2D/3D accuracies of implant position after guided surgery using different surgical protocols: a retrospective study. J Prosthodont Res. 2020;64:424–30.CrossRef Monaco C, Arena A, Corsaletti L, Santomauro V, Venezia P. 2D/3D accuracies of implant position after guided surgery using different surgical protocols: a retrospective study. J Prosthodont Res. 2020;64:424–30.CrossRef
4.
go back to reference Camardella LT, Vilella OV, van Hezel MM, Breuning KH. Accuracy of stereolithographically printed digital models compared to plaster models. J Orofac Orthop. 2017;78:394–402.CrossRef Camardella LT, Vilella OV, van Hezel MM, Breuning KH. Accuracy of stereolithographically printed digital models compared to plaster models. J Orofac Orthop. 2017;78:394–402.CrossRef
5.
go back to reference Camardella LT, de Vasconcellos VO, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthodont Dentofac Orthop. 2017;151:1178–87.CrossRef Camardella LT, de Vasconcellos VO, Breuning H. Accuracy of printed dental models made with 2 prototype technologies and different designs of model bases. Am J Orthodont Dentofac Orthop. 2017;151:1178–87.CrossRef
6.
go back to reference Zhang F, Suh KJ, Lee KM. Validity of intraoral scans compared with plaster models: an in-vivo comparison of dental measurements and 3D surface analysis. PLoS One. 2016;11:e0157713.CrossRef Zhang F, Suh KJ, Lee KM. Validity of intraoral scans compared with plaster models: an in-vivo comparison of dental measurements and 3D surface analysis. PLoS One. 2016;11:e0157713.CrossRef
7.
go back to reference Baig MR, Buzayan MM, Yunus N. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions. J Invest Clin Dentistry. 2018;9:e12320.CrossRef Baig MR, Buzayan MM, Yunus N. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions. J Invest Clin Dentistry. 2018;9:e12320.CrossRef
8.
go back to reference Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17:1759–64.CrossRef Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17:1759–64.CrossRef
9.
go back to reference Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig. 2014;18:1687–94.CrossRef Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig. 2014;18:1687–94.CrossRef
10.
go back to reference Derksen W, Wismeijer D, Flügge T, Hassan B, Tahmaseb A. The accuracy of computer-guided implant surgery with tooth supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study. Clin Oral Implants Res. 2019;30:1005–15.CrossRef Derksen W, Wismeijer D, Flügge T, Hassan B, Tahmaseb A. The accuracy of computer-guided implant surgery with tooth supported, digitally designed drill guides based on CBCT and intraoral scanning. A prospective cohort study. Clin Oral Implants Res. 2019;30:1005–15.CrossRef
11.
go back to reference Smitkarn P, Subbalekha K, Mattheos N, Pimkhaokham A. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J Clin Periodontol. 2019;46:949–57.CrossRef Smitkarn P, Subbalekha K, Mattheos N, Pimkhaokham A. The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. J Clin Periodontol. 2019;46:949–57.CrossRef
12.
go back to reference Behneke A, Burwinkel M, Behneke N. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 2012;23:416–23.CrossRef Behneke A, Burwinkel M, Behneke N. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 2012;23:416–23.CrossRef
13.
go back to reference Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29:416–35.CrossRef Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin Oral Implants Res. 2018;29:416–35.CrossRef
14.
go back to reference Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29:25–42.CrossRef Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29:25–42.CrossRef
15.
go back to reference El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static computer assisted implant surgery. Clin Implant Dentistry Relat Res. 2019;21:101–7.CrossRef El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static computer assisted implant surgery. Clin Implant Dentistry Relat Res. 2019;21:101–7.CrossRef
16.
go back to reference Bover-Ramos F, Viña-Almunia J, Cervera-Ballester J, Peñarrocha-Diago M, García-Mira B. Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants. 2018;33:101–15.CrossRef Bover-Ramos F, Viña-Almunia J, Cervera-Ballester J, Peñarrocha-Diago M, García-Mira B. Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. Int J Oral Maxillofac Implants. 2018;33:101–15.CrossRef
17.
go back to reference El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery. Clin Oral Implants Res. 2019;30:1067–75.CrossRef El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery. Clin Oral Implants Res. 2019;30:1067–75.CrossRef
18.
go back to reference Toyoshima T, Tanaka H, Sasaki M, Ichimaru E, Naito Y. Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study. Clin Exp Dental Res. 2015;1:10–7.CrossRef Toyoshima T, Tanaka H, Sasaki M, Ichimaru E, Naito Y. Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study. Clin Exp Dental Res. 2015;1:10–7.CrossRef
19.
go back to reference Kattadiyil MT, Parciak E, Puri S, Scherer MD. CAD/CAM guided surgery in implant dentistry: a brief review. Alpha Omegan. 2014;107:26–31.PubMed Kattadiyil MT, Parciak E, Puri S, Scherer MD. CAD/CAM guided surgery in implant dentistry: a brief review. Alpha Omegan. 2014;107:26–31.PubMed
Metadata
Title
Accuracy of guided surgery using the silicon impression and digital impression method for the mandibular free end: a comparative study
Authors
Koudai Nagata
Kei Fuchigami
Noriyuki Hoshi
Mihoko Atsumi
Katsuhiko Kimoto
Hiromasa Kawana
Publication date
01-12-2021
Publisher
Springer Berlin Heidelberg
Keyword
Silicone
Published in
International Journal of Implant Dentistry / Issue 1/2021
Electronic ISSN: 2198-4034
DOI
https://doi.org/10.1186/s40729-020-00281-z

Other articles of this Issue 1/2021

International Journal of Implant Dentistry 1/2021 Go to the issue