Skip to main content
Top
Published in: International Journal of Implant Dentistry 1/2017

Open Access 01-12-2017 | Research

Comparison of access-hole filling materials for screw retained implant prostheses: 12-month in vivo study

Authors: Rémy Tanimura, Shiro Suzuki

Published in: International Journal of Implant Dentistry | Issue 1/2017

Login to get access

Abstract

Background

Screw retained implant prostheses seem to be an efficient restorative method to prevent peri-implantitis caused by cement excess around the abutment. The drawback of the screw-retained prostheses is the difficulty to realize an efficient access-hole filling functionally and aesthetically. Up to now, few in vitro and in vivo studies were reported in the literature. The aim of this study was to evaluate clinical performances of two direct filling materials through a period of 12 months.

Methods

To pursue a previous in vitro evaluation, this in vivo 12 months prospective study followed up and compared the access-hole filling integrity of a modified 4-META (4-methacryloxyethyl trimellitate anhydride)/MMA-TBB (methyl methacrylate-tri-n-butyl borane) – based resin (M4M) and a photo-polymerizing nano-hybrid composite resin (CR).
Twenty-eight access-holes were filled with both materials respectively, then impressions and intra-oral photographs were taken at T = 0, T = 1 M (month), 3, 6, and 12 M. The access-hole surface measurement and the margin analysis (depth and angle) were carried out. The VAS (visual analogue scale) value on marginal discoloration and integrity at the baseline T = 0 and T = 12 M was recorded.

Results

The mean values of the surface areas changes from T = 1 to T = 12 M were 83.3 ± 11.5% for group CR and 77.1 ± 13.1% for group M4M, respectively. (Mann-Whitney test p < 0.05, p = 0.046). The mean marginal depth at T = 12 M for group CR were 141.2 ± 125.5 μm and 132.1 ± 107.8 μm for the group M4M, respectively. (Mann-Whitney test p > 0.05, p = 0.58). The mean values of the angle formed at the margin (T = 12 M) were for group CR 39.5 ± 19.4° and 28.2 ± 17.2° for group M4M, respectively (Mann-Whitney test p < 0.0001). The photographical analysis by VAS values showed no significant difference between CR and M4M groups (Mann-Whitney test p > 0.05, p = 0.848).

Conclusions

Based on intra- and extra-oral evaluations with the limitation, both CR and M4M combined with a ceramic primer are indicated as promising materials to fill the access-hole. Further long-term investigation is necessary to confirm this finding.
Literature
1.
go back to reference Millen C, Brägger U, Wittneben JG. Influence of prosthesis type and retention mechanism on complications with fixed implant-supported prostheses: a systematic review applying multivariate analyses. Int J Oral Maxillofac Implants. 2015;30(1):110–24.CrossRefPubMed Millen C, Brägger U, Wittneben JG. Influence of prosthesis type and retention mechanism on complications with fixed implant-supported prostheses: a systematic review applying multivariate analyses. Int J Oral Maxillofac Implants. 2015;30(1):110–24.CrossRefPubMed
2.
go back to reference Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants. 2000;15:239–46.PubMed Guichet DL, Caputo AA, Choi H, Sorensen JA. Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants. 2000;15:239–46.PubMed
3.
go back to reference de França DG, Morais MH, dasNeves FD, Carreiro AF, Barbosa GA. Precision fit of screw-retained implant-supported fixed dental prostheses fabricated by CAD/CAM, copy-milling, and conventional methods. Int J Oral Maxillofac Implants. 2016. doi:10.11607/jomi.5023.PubMed de França DG, Morais MH, dasNeves FD, Carreiro AF, Barbosa GA. Precision fit of screw-retained implant-supported fixed dental prostheses fabricated by CAD/CAM, copy-milling, and conventional methods. Int J Oral Maxillofac Implants. 2016. doi:10.​11607/​jomi.​5023.PubMed
4.
go back to reference Cho SC, Small PN, Elian N, Tarnow D. Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data. Implant Dent. 2004;13:245–50.CrossRefPubMed Cho SC, Small PN, Elian N, Tarnow D. Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data. Implant Dent. 2004;13:245–50.CrossRefPubMed
5.
go back to reference Korsch M, Obst U, Walter W. Cement-associated per-implantitis: a retrospective clinical observational study of fixed implant-supported restorations using a methacrylate cement. Clin Oral Implants Res. 2014;25(7):797–802.CrossRefPubMed Korsch M, Obst U, Walter W. Cement-associated per-implantitis: a retrospective clinical observational study of fixed implant-supported restorations using a methacrylate cement. Clin Oral Implants Res. 2014;25(7):797–802.CrossRefPubMed
6.
go back to reference Linkevicius T, Puisys A, Vindasiute E, Linkeviciene L, Apse P. Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis. Clin Oral Implants Res. 2013;24(11):1179–84.PubMed Linkevicius T, Puisys A, Vindasiute E, Linkeviciene L, Apse P. Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis. Clin Oral Implants Res. 2013;24(11):1179–84.PubMed
7.
go back to reference Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prothet Dent. 1997;77:28–35.CrossRef Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prothet Dent. 1997;77:28–35.CrossRef
8.
go back to reference Torrado E, Ercoli C, Al M, Graser GN, Tallents RH, Cordaro L. A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns. J Prosthet Dent. 2004;91:532–7.CrossRefPubMed Torrado E, Ercoli C, Al M, Graser GN, Tallents RH, Cordaro L. A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns. J Prosthet Dent. 2004;91:532–7.CrossRefPubMed
9.
go back to reference Derafshi R, Farzin M, Taghva M, Heidary H, Atashkar B. The effects of new design of access hole on porcelain fracture resistance of implant-supported crowns. J Dent (Shiraz). 2015;16(1 Suppl):61–7. Derafshi R, Farzin M, Taghva M, Heidary H, Atashkar B. The effects of new design of access hole on porcelain fracture resistance of implant-supported crowns. J Dent (Shiraz). 2015;16(1 Suppl):61–7.
10.
go back to reference Taylor RC, Ghoneim AS, McGlumphy EA. An esthetic technique to fill screw-retained fixed prostheses. J Oral Implantol. 2004;30(6):384–5.CrossRefPubMed Taylor RC, Ghoneim AS, McGlumphy EA. An esthetic technique to fill screw-retained fixed prostheses. J Oral Implantol. 2004;30(6):384–5.CrossRefPubMed
11.
go back to reference Weininger B, McGlumphy E, Beck M. Esthetic evaluation of materials used to fill access holes of screw-retained implant crowns. J Oral Implantol. 2008;34(3):145–9.CrossRefPubMed Weininger B, McGlumphy E, Beck M. Esthetic evaluation of materials used to fill access holes of screw-retained implant crowns. J Oral Implantol. 2008;34(3):145–9.CrossRefPubMed
12.
go back to reference Tanimura R, Suzuki S. In vitro evaluation of a modified 4-META/MMA-TBB resin for filling access holes of screw-retained implant prostheses. J Biomed Mater Res B ApplBiomater. 2015;103(5):1030–6.CrossRef Tanimura R, Suzuki S. In vitro evaluation of a modified 4-META/MMA-TBB resin for filling access holes of screw-retained implant prostheses. J Biomed Mater Res B ApplBiomater. 2015;103(5):1030–6.CrossRef
13.
go back to reference Korsch M, Walther W. Peri-implantitis associated with type of cement: a retrospective analysis of different types of cement and their clinical correlation to the peri-implant tissue. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e434–43.CrossRefPubMed Korsch M, Walther W. Peri-implantitis associated with type of cement: a retrospective analysis of different types of cement and their clinical correlation to the peri-implant tissue. Clin Implant Dent Relat Res. 2015;17(Suppl 2):e434–43.CrossRefPubMed
14.
go back to reference Linkevicius T, Vindasiute E, Puisys A, Linkeviciene L, Maslova N, Puriene A. The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study. Clin Oral Implants Res. 2013;24(1):71–6.CrossRefPubMed Linkevicius T, Vindasiute E, Puisys A, Linkeviciene L, Maslova N, Puriene A. The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study. Clin Oral Implants Res. 2013;24(1):71–6.CrossRefPubMed
15.
go back to reference Vindasiute E, Puisys A, Maslova N, Linkeviciene L, Peciuliene V, Linkevicius T. Clinical factors influencing removal of the cement excess in implant-supported restorations. Clin Implant Dent Relat Res. 2015;17(4):771–8.CrossRefPubMed Vindasiute E, Puisys A, Maslova N, Linkeviciene L, Peciuliene V, Linkevicius T. Clinical factors influencing removal of the cement excess in implant-supported restorations. Clin Implant Dent Relat Res. 2015;17(4):771–8.CrossRefPubMed
16.
go back to reference Thalji G, Bryington M, De Kok IJ, Cooper LF. Prosthodontic management of implant therapy. Dent Clin North Am. 2014;58(1):207–25.CrossRefPubMed Thalji G, Bryington M, De Kok IJ, Cooper LF. Prosthodontic management of implant therapy. Dent Clin North Am. 2014;58(1):207–25.CrossRefPubMed
17.
go back to reference Dittmer MP, Nensa M, Stiesch M, Kohorst P. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading. J Appl Oral Sci. 2013;21(4):307–13.CrossRefPubMedPubMedCentral Dittmer MP, Nensa M, Stiesch M, Kohorst P. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks (I-Bridge®2) before and after cyclic mechanical loading. J Appl Oral Sci. 2013;21(4):307–13.CrossRefPubMedPubMedCentral
18.
go back to reference Turkylmaz I, Patel NS, McGlumphy EA. Oral rehabilitation of a severely resorbed edentoulous maxilla with screw-retained hybrid denture using Cresco system: a case report. Eur J Dent. 2008;2(3):220–3. Turkylmaz I, Patel NS, McGlumphy EA. Oral rehabilitation of a severely resorbed edentoulous maxilla with screw-retained hybrid denture using Cresco system: a case report. Eur J Dent. 2008;2(3):220–3.
19.
go back to reference Balshi SF, Wolfinger GJ, Balshi TJ. A protocol for immediate placement of a prefabricated screw-retained provisional prosthesis using computed tomography and guided surgery and incorporating planned alveoplasty. Int J Periodontics Restorative Dent. 2011;31(1):49–55.PubMed Balshi SF, Wolfinger GJ, Balshi TJ. A protocol for immediate placement of a prefabricated screw-retained provisional prosthesis using computed tomography and guided surgery and incorporating planned alveoplasty. Int J Periodontics Restorative Dent. 2011;31(1):49–55.PubMed
20.
go back to reference Meloni SM, De Riu G, Pisano M, Tullio A. Full arch restoration with computer-assisted implant surgery and immediate loading in edentulous ridges with dental fresh extraction sockets. One year results of 10 consecutively treated patients: guided implant surgery and extraction sockets. J Maxillofac Oral Surg. 2013;12(3):321–5.CrossRefPubMed Meloni SM, De Riu G, Pisano M, Tullio A. Full arch restoration with computer-assisted implant surgery and immediate loading in edentulous ridges with dental fresh extraction sockets. One year results of 10 consecutively treated patients: guided implant surgery and extraction sockets. J Maxillofac Oral Surg. 2013;12(3):321–5.CrossRefPubMed
21.
go back to reference Lee A, Okayasu K, Wang HL. Screw-versus cement-retained implant restorations: current concepts. Implant Dent. 2010;19(1):8–15.CrossRefPubMed Lee A, Okayasu K, Wang HL. Screw-versus cement-retained implant restorations: current concepts. Implant Dent. 2010;19(1):8–15.CrossRefPubMed
22.
go back to reference Cicciù M, Beretta M, Risitano G, Maiorana C. Cemented-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatol. 2008;57(4):167–79.PubMed Cicciù M, Beretta M, Risitano G, Maiorana C. Cemented-retained vs screw-retained implant restorations: an investigation on 1939 dental implants. Minerva Stomatol. 2008;57(4):167–79.PubMed
23.
go back to reference Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants. 2003;18(5):719–28.PubMed Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants. 2003;18(5):719–28.PubMed
24.
go back to reference Taira Y, Sakai M, Sawase T. Effects of primer containing silane and thiophosphate monomers on bonding resin to a leucite-reinforced ceramic. J Dent. 2012;40(5):353–8.CrossRefPubMed Taira Y, Sakai M, Sawase T. Effects of primer containing silane and thiophosphate monomers on bonding resin to a leucite-reinforced ceramic. J Dent. 2012;40(5):353–8.CrossRefPubMed
25.
go back to reference Kato H, Matsumura H, Tanaka T, Atsuta M. Bond strength and durability of porcelain bonding systems. J Prosthet Dent. 1996;75(2):163–8.CrossRefPubMed Kato H, Matsumura H, Tanaka T, Atsuta M. Bond strength and durability of porcelain bonding systems. J Prosthet Dent. 1996;75(2):163–8.CrossRefPubMed
26.
go back to reference Queiroz JR, Souza RO, Nogueira Junior Jr L, Ozcan M, Bottino MA. Influence of acid-etching and ceramic primers on the repair of a glass ceramic. Gen Dent. 2012;60(2):e79–85.PubMed Queiroz JR, Souza RO, Nogueira Junior Jr L, Ozcan M, Bottino MA. Influence of acid-etching and ceramic primers on the repair of a glass ceramic. Gen Dent. 2012;60(2):e79–85.PubMed
27.
go back to reference Bottino MA, Snellaert A, Bergoli CD, Özcan M, Bottino MC, Valandro LF. Effect of ceramic etching protocols on resin bond strength to a felspar ceramic. Oper Dent. 2015;40(2):E40–6.CrossRefPubMed Bottino MA, Snellaert A, Bergoli CD, Özcan M, Bottino MC, Valandro LF. Effect of ceramic etching protocols on resin bond strength to a felspar ceramic. Oper Dent. 2015;40(2):E40–6.CrossRefPubMed
28.
go back to reference Ozcan M, Allahbeickaraghi A, Dündar M. Possible hazardous effects of hydrofluoric acid and recommendations for treatment approach: a review. Clin Oral Investig. 2012;16(1):15–23.CrossRefPubMed Ozcan M, Allahbeickaraghi A, Dündar M. Possible hazardous effects of hydrofluoric acid and recommendations for treatment approach: a review. Clin Oral Investig. 2012;16(1):15–23.CrossRefPubMed
29.
go back to reference Magne P, Cascione D. Influence of post-etching cleaning and connecting porcelain on the microtensile bond strength of composite resin to feldspatic porcelain. J Prothet Dent. 2006;96(5):354–61.CrossRef Magne P, Cascione D. Influence of post-etching cleaning and connecting porcelain on the microtensile bond strength of composite resin to feldspatic porcelain. J Prothet Dent. 2006;96(5):354–61.CrossRef
30.
go back to reference Leinfelder KF, Suzuki S. In vitro wear device for determining posterior composite wear. J Am Dent Assoc. 1999;130(9):1347–53.CrossRefPubMed Leinfelder KF, Suzuki S. In vitro wear device for determining posterior composite wear. J Am Dent Assoc. 1999;130(9):1347–53.CrossRefPubMed
31.
go back to reference Sumino N, Tsubota K, Takamizawa T, Shiratsuchi K, Miyazawa M, Latta MA. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions. Acta Odontol Scand. 2013;71:820–7.CrossRefPubMed Sumino N, Tsubota K, Takamizawa T, Shiratsuchi K, Miyazawa M, Latta MA. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions. Acta Odontol Scand. 2013;71:820–7.CrossRefPubMed
32.
go back to reference Ikeda T, Wakabayashi N, Ona M, Ohyama T. Effects of polymerization shrinkage on the interfacial stress at resin-metal joint in denture-base: a non-linear FE stress analysis. Dent Mater. 2006;22:413–9.CrossRefPubMed Ikeda T, Wakabayashi N, Ona M, Ohyama T. Effects of polymerization shrinkage on the interfacial stress at resin-metal joint in denture-base: a non-linear FE stress analysis. Dent Mater. 2006;22:413–9.CrossRefPubMed
33.
go back to reference Kawai K, Leinfelder KF. Effect of resin composite adhesion on marginal degradation. Dent Mater J. 1995;14(2):211–20.CrossRefPubMed Kawai K, Leinfelder KF. Effect of resin composite adhesion on marginal degradation. Dent Mater J. 1995;14(2):211–20.CrossRefPubMed
34.
go back to reference Naito K. Bonding and wear characteristics of a tri-n-butylborane initiated adhesive resin filled with pre-polymerized composite particles. J Oral Sci. 2011;53(1):109–16. Naito K. Bonding and wear characteristics of a tri-n-butylborane initiated adhesive resin filled with pre-polymerized composite particles. J Oral Sci. 2011;53(1):109–16.
35.
go back to reference Wimmer T, Huffmann AM, Eichberger M, Schmidlin PR, Stawarczyk B. Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: effect of specimen geometries, antagonist materials and test set-up configuration. Dent Mater. 2016;32(6):e127–36.CrossRefPubMed Wimmer T, Huffmann AM, Eichberger M, Schmidlin PR, Stawarczyk B. Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: effect of specimen geometries, antagonist materials and test set-up configuration. Dent Mater. 2016;32(6):e127–36.CrossRefPubMed
36.
go back to reference Kurt M, Ural C, Kulunk T, Sanal AF, Erkoçak A. The effect of screw color and technique to fill access hole on the final color of screw-retained implants crowns. J Oral Implantol. 2011;37(6):673–9.CrossRefPubMed Kurt M, Ural C, Kulunk T, Sanal AF, Erkoçak A. The effect of screw color and technique to fill access hole on the final color of screw-retained implants crowns. J Oral Implantol. 2011;37(6):673–9.CrossRefPubMed
37.
go back to reference de Pereira R P, Rocha CO, Reis JM, Arioli-Filho JN. Influence of sealing of the screw access hole on the fracture resistance of implant-supported restorations. Braz Dent J. 2016;27(2):148–52.CrossRef de Pereira R P, Rocha CO, Reis JM, Arioli-Filho JN. Influence of sealing of the screw access hole on the fracture resistance of implant-supported restorations. Braz Dent J. 2016;27(2):148–52.CrossRef
38.
go back to reference Mihali S, Canjau S, Bratu E, Wang HL. Utilization of ceramic inlays for sealing implant prostheses screw access holes: a case-control study. Int J Oral Maxillofac Implants. 2016;31(5):1142–9.CrossRefPubMed Mihali S, Canjau S, Bratu E, Wang HL. Utilization of ceramic inlays for sealing implant prostheses screw access holes: a case-control study. Int J Oral Maxillofac Implants. 2016;31(5):1142–9.CrossRefPubMed
Metadata
Title
Comparison of access-hole filling materials for screw retained implant prostheses: 12-month in vivo study
Authors
Rémy Tanimura
Shiro Suzuki
Publication date
01-12-2017
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Implant Dentistry / Issue 1/2017
Electronic ISSN: 2198-4034
DOI
https://doi.org/10.1186/s40729-017-0076-4

Other articles of this Issue 1/2017

International Journal of Implant Dentistry 1/2017 Go to the issue