Skip to main content
Top
Published in: Antimicrobial Resistance & Infection Control 1/2018

Open Access 01-12-2018 | Research

Do wearable alcohol-based handrub dispensers increase hand hygiene compliance? - a mixed-methods study

Authors: Jonas Keller, Aline Wolfensberger, Lauren Clack, Stefan P. Kuster, Mesida Dunic, Doris Eis, Yvonne Flammer, Dagmar I. Keller, Hugo Sax

Published in: Antimicrobial Resistance & Infection Control | Issue 1/2018

Login to get access

Abstract

Background

Hand Hygiene (HH) compliance was shown to be poor in several studies. Improving the availability of alcohol-based hand rub (ABHR) is a cornerstone for increasing HH compliance.

Methods

In this study, we introduced wearable dispensers for ABHR in an Emergency Department (ED) well equipped with mounted ABHR dispensers and accompanied this single-modal intervention by a quasi-experimental mixed-method study. The study was performed in the ED of the University Hospital Zurich, Switzerland, a 950-bed tertiary teaching hospital. During a five-week baseline period and a seven-week intervention period, we observed HH compliance according to the WHO ‘Five Moments’ concept, measured ABHR consumption, and investigated perceived ABHR availability, self-reported HH compliance and knowledge of HH indications by questionnaire. Multivariable logistic regression was used to identify independent determinants for HH compliance. In addition, semi-structured interviews were conducted and thematically analyzed to assess barriers and facilitators for the use of the newly introduced dispensers.

Results

Across 811 observed HH opportunities, the HH compliance for all moments was 56% (95% confidence interval (CI), 51–62%) during baseline and 64% (CI, 59–68%) during intervention period, respectively. In the multivariable analysis adjusted for sex, profession, and WHO HH moment, there was no difference in HH compliance between baseline and intervention (adjusted Odds ratio: 1.22 (0.89–1.66), p = 0.22), No significant changes were observed in consumption and perceived availability of ABHR. During intervention, 7.5% ABHR was consumed using wearable dispensers. HCP perceived wearable dispensers as unnecessary since mounted dispensers were readily accessible. Poor ergonomic design of the wearable dispenser emerged as a main barrier, especially its lid and fastening mechanism. Interviewees identified two ideal situations for wearable dispensers, HCP who accompany patients from ED to other wards, and HCP approaching a patient from a non-patient areas in the ED such as the central working station or the meeting room.

Conclusion

The introduction of wearable dispensers did not increase observed hand hygiene compliance or ABHR consumption in an ED already well equipped with mounted dispensers. For broader acceptance and use, wearable dispensers might benefit from an optimized ergonomic design.
Literature
1.
go back to reference Zimlichman E, et al. Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013;173(22):2039–46.CrossRefPubMed Zimlichman E, et al. Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013;173(22):2039–46.CrossRefPubMed
2.
go back to reference Pittet D, et al. Evidence-based model for hand transmission during patient care and the role of improved practices. Lancet Infect Dis. 2006;6(10):641–52.CrossRefPubMed Pittet D, et al. Evidence-based model for hand transmission during patient care and the role of improved practices. Lancet Infect Dis. 2006;6(10):641–52.CrossRefPubMed
3.
go back to reference Allegranzi B, Pittet D. Role of hand hygiene in healthcare-associated infection prevention. J Hosp Infect. 2009;73(4):305–15.CrossRefPubMed Allegranzi B, Pittet D. Role of hand hygiene in healthcare-associated infection prevention. J Hosp Infect. 2009;73(4):305–15.CrossRefPubMed
5.
go back to reference Erasmus V, et al. Systematic review of studies on compliance with hand hygiene guidelines in hospital care. Infect Control Hosp Epidemiol. 2010;31(3):283–94.CrossRefPubMed Erasmus V, et al. Systematic review of studies on compliance with hand hygiene guidelines in hospital care. Infect Control Hosp Epidemiol. 2010;31(3):283–94.CrossRefPubMed
7.
go back to reference Pittet D, et al. Hand hygiene among physicians: performance, beliefs, and perceptions. Ann Intern Med. 2004;141(1):1–8.CrossRefPubMed Pittet D, et al. Hand hygiene among physicians: performance, beliefs, and perceptions. Ann Intern Med. 2004;141(1):1–8.CrossRefPubMed
8.
go back to reference Goodliffe L, et al. Rate of healthcare worker-patient interaction and hand hygiene opportunities in an acute care setting. Infect Control Hosp Epidemiol. 2014;35(3):225–30.CrossRefPubMed Goodliffe L, et al. Rate of healthcare worker-patient interaction and hand hygiene opportunities in an acute care setting. Infect Control Hosp Epidemiol. 2014;35(3):225–30.CrossRefPubMed
9.
go back to reference Pittet D, et al. Effectiveness of a hospital-wide programme to improve compliance with hand hygiene. Infection Control Programme Lancet. 2000;356(9238):1307–12.PubMed Pittet D, et al. Effectiveness of a hospital-wide programme to improve compliance with hand hygiene. Infection Control Programme Lancet. 2000;356(9238):1307–12.PubMed
10.
go back to reference Yeung WK, Tam WS, Wong TW. Clustered randomized controlled trial of a hand hygiene intervention involving pocket-sized containers of alcohol-based hand rub for the control of infections in long-term care facilities. Infect Control Hosp Epidemiol. 2011;32(1):67–76.CrossRefPubMed Yeung WK, Tam WS, Wong TW. Clustered randomized controlled trial of a hand hygiene intervention involving pocket-sized containers of alcohol-based hand rub for the control of infections in long-term care facilities. Infect Control Hosp Epidemiol. 2011;32(1):67–76.CrossRefPubMed
11.
go back to reference Haas JP, Larson EL. Impact of wearable alcohol gel dispensers on hand hygiene in an emergency department. Acad Emerg Med. 2008;15(4):393–6.CrossRefPubMed Haas JP, Larson EL. Impact of wearable alcohol gel dispensers on hand hygiene in an emergency department. Acad Emerg Med. 2008;15(4):393–6.CrossRefPubMed
12.
go back to reference Sax H, et al. The World Health Organization hand hygiene observation method. Am J Infect Control. 2009;37(10):827–34.CrossRefPubMed Sax H, et al. The World Health Organization hand hygiene observation method. Am J Infect Control. 2009;37(10):827–34.CrossRefPubMed
13.
go back to reference WHO. In WHO Guidelines on Hand Hygiene in Health Care. Geneva: First Global Patient Safety Challenge Clean Care Is Safer Care; 2009. WHO. In WHO Guidelines on Hand Hygiene in Health Care. Geneva: First Global Patient Safety Challenge Clean Care Is Safer Care; 2009.
14.
go back to reference Sax H, et al. My five moments for hand hygiene': a user-centred design approach to understand, train, monitor and report hand hygiene. J Hosp Infect. 2007;67(1):9–21.CrossRefPubMed Sax H, et al. My five moments for hand hygiene': a user-centred design approach to understand, train, monitor and report hand hygiene. J Hosp Infect. 2007;67(1):9–21.CrossRefPubMed
15.
go back to reference Strauss AL, Corbin JM. Grounded theory in practice. Thousand Oaks: Sage Publications; 1997. Strauss AL, Corbin JM. Grounded theory in practice. Thousand Oaks: Sage Publications; 1997.
16.
go back to reference Hugonnet S, Perneger TV, Pittet D. Alcohol-based handrub improves compliance with hand hygiene in intensive care units. Arch Intern Med. 2002;162(9):1037–43.CrossRefPubMed Hugonnet S, Perneger TV, Pittet D. Alcohol-based handrub improves compliance with hand hygiene in intensive care units. Arch Intern Med. 2002;162(9):1037–43.CrossRefPubMed
17.
go back to reference Picheansathian W. A systematic review on the effectiveness of alcohol-based solutions for hand hygiene. Int J Nurs Pract. 2004;10(1):3–9.CrossRefPubMed Picheansathian W. A systematic review on the effectiveness of alcohol-based solutions for hand hygiene. Int J Nurs Pract. 2004;10(1):3–9.CrossRefPubMed
19.
go back to reference Koff MD, et al. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009;110(5):978–85.CrossRefPubMed Koff MD, et al. Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device. Anesthesiology. 2009;110(5):978–85.CrossRefPubMed
20.
go back to reference Parks CL, Schroeder KM, Galgon RE. Personal hand gel for improved hand hygiene compliance on the regional anesthesia team. J Anesth. 2015;29(6):899–903.CrossRefPubMed Parks CL, Schroeder KM, Galgon RE. Personal hand gel for improved hand hygiene compliance on the regional anesthesia team. J Anesth. 2015;29(6):899–903.CrossRefPubMed
21.
go back to reference Drews FA, Bakdash JZ, Gleed JR. Improving central line maintenance to reduce central line-associated bloodstream infections. Am J Infect Control. 2017;45(11):1224–30.CrossRefPubMed Drews FA, Bakdash JZ, Gleed JR. Improving central line maintenance to reduce central line-associated bloodstream infections. Am J Infect Control. 2017;45(11):1224–30.CrossRefPubMed
22.
go back to reference Drews FA. Adherence engineering. a new approach to increasing adherence to protocols Ergon Des. 2013;21:19–25. Drews FA. Adherence engineering. a new approach to increasing adherence to protocols Ergon Des. 2013;21:19–25.
23.
go back to reference Cure L, Van Enk R. Effect of hand sanitizer location on hand hygiene compliance. Am J Infect Control. 2015;43(9):917–21.CrossRefPubMed Cure L, Van Enk R. Effect of hand sanitizer location on hand hygiene compliance. Am J Infect Control. 2015;43(9):917–21.CrossRefPubMed
24.
go back to reference Rogers WA, Mykityshyn AL, Cambell RH, Fisk AD. Analysis of a “simple” medical device. Ergon Des. 2001;9(1):6–14. Rogers WA, Mykityshyn AL, Cambell RH, Fisk AD. Analysis of a “simple” medical device. Ergon Des. 2001;9(1):6–14.
25.
go back to reference Cafazzo, J.A. and O. St-Cyr, From discovery to design: the evolution of human factors in healthcare. Healthc Q, 2012. 15 Spec No: p. 24–29.CrossRefPubMed Cafazzo, J.A. and O. St-Cyr, From discovery to design: the evolution of human factors in healthcare. Healthc Q, 2012. 15 Spec No: p. 24–29.CrossRefPubMed
26.
go back to reference Jick TD. Mixing qualitative and quantitative methods - triangulation in action. Adm Sci Q. 1979;24(4):602–11.CrossRef Jick TD. Mixing qualitative and quantitative methods - triangulation in action. Adm Sci Q. 1979;24(4):602–11.CrossRef
Metadata
Title
Do wearable alcohol-based handrub dispensers increase hand hygiene compliance? - a mixed-methods study
Authors
Jonas Keller
Aline Wolfensberger
Lauren Clack
Stefan P. Kuster
Mesida Dunic
Doris Eis
Yvonne Flammer
Dagmar I. Keller
Hugo Sax
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Antimicrobial Resistance & Infection Control / Issue 1/2018
Electronic ISSN: 2047-2994
DOI
https://doi.org/10.1186/s13756-018-0439-5

Other articles of this Issue 1/2018

Antimicrobial Resistance & Infection Control 1/2018 Go to the issue