Skip to main content
Top
Published in: Antimicrobial Resistance & Infection Control 1/2018

Open Access 01-12-2018 | Research

Bioaerosol concentrations generated from toilet flushing in a hospital-based patient care setting

Authors: Samantha D. Knowlton, Corey L. Boles, Eli N. Perencevich, Daniel J. Diekema, Matthew W. Nonnenmann, CDC Epicenters Program

Published in: Antimicrobial Resistance & Infection Control | Issue 1/2018

Login to get access

Abstract

Background

In the United States, 1.7 million immunocompromised patients contract a healthcare-associated infection, annually. These infections increase morbidity, mortality and costs of care. A relatively unexplored route of transmission is the generation of bioaerosols during patient care. Transmission of pathogenic microorganisms may result from inhalation or surface contamination of bioaerosols. The toilet flushing of patient fecal waste may be a source of bioaerosols. To date, no study has investigated bioaerosol concentrations from flushing fecal wastes during patient care.

Methods

Particle and bioaerosol concentrations were measured in hospital bathrooms across three sampling conditions; no waste no flush, no waste with flush, and fecal waste with flush. Particle and bioaerosol concentrations were measured with a particle counter bioaerosol sampler both before after a toilet flushing event at distances of 0.15, 0.5, and 1 m from the toilet for 5, 10, 15 min.

Results

Particle concentrations measured before and after the flush were found to be significantly different (0.3–10 μm). Bioaerosol concentrations when flushing fecal waste were found to be significantly greater than background concentrations (p-value = 0.005). However, the bioaerosol concentrations were not different across time (p-value = 0.977) or distance (p-value = 0.911) from the toilet, suggesting that aerosols generated may remain for longer than 30 min post flush. Toilets produce aerosol particles when flushed, with the majority of the particles being 0.3 μm in diameter. The particles aerosolized include microorganisms remaining from previous use or from fecal wastes. Differences in bioaerosol concentrations across conditions also suggest that toilet flushing is a source of bioaerosols that may result in transmission of pathogenic microorganisms.

Conclusions

This study is the first to quantify particles and bioaerosols produced from flushing a hospital toilet during routine patient care. Future studies are needed targeting pathogens associated with gastrointestinal illness and evaluating aerosol exposure reduction interventions.
Literature
1.
go back to reference Klevens RM, Edwards JR, Richards CL Jr, Horan TC, Gaynes RP, Pollock DA, Cardo DM. Estimating health care-associated infections and deaths in US hospitals, 2002. Public Health Rep. 2007;122(2):160–6.CrossRefPubMedPubMedCentral Klevens RM, Edwards JR, Richards CL Jr, Horan TC, Gaynes RP, Pollock DA, Cardo DM. Estimating health care-associated infections and deaths in US hospitals, 2002. Public Health Rep. 2007;122(2):160–6.CrossRefPubMedPubMedCentral
2.
go back to reference Hassan M, Tuckman HP, Patrick RH, Kountz DS, Kohn JL. Cost of hospital-acquired infection. Hosp Top. 2010;88:82–9.CrossRefPubMed Hassan M, Tuckman HP, Patrick RH, Kountz DS, Kohn JL. Cost of hospital-acquired infection. Hosp Top. 2010;88:82–9.CrossRefPubMed
4.
go back to reference Levy SB. Factors impacting on the problem of antibiotic resistance. J Antimicrob Chemother. 2002;49:25–30.CrossRefPubMed Levy SB. Factors impacting on the problem of antibiotic resistance. J Antimicrob Chemother. 2002;49:25–30.CrossRefPubMed
5.
go back to reference Huslage K, Rutala WA, Weber DJ. A quantitative approach to defining “high-touch” surfaces in hospitals. Infect Control Hosp Epidemiol. 2010;31:850–3.CrossRefPubMed Huslage K, Rutala WA, Weber DJ. A quantitative approach to defining “high-touch” surfaces in hospitals. Infect Control Hosp Epidemiol. 2010;31:850–3.CrossRefPubMed
6.
go back to reference Weinstein RA, Hota B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis. 2004;39:1182–9.CrossRef Weinstein RA, Hota B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis. 2004;39:1182–9.CrossRef
7.
go back to reference Io M. Emerging infections: microbial threats to health in the United States. Washington, DC: The National Academies Press; 1992. Io M. Emerging infections: microbial threats to health in the United States. Washington, DC: The National Academies Press; 1992.
8.
go back to reference Otter JA, Yezli S, French GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol. 2011;32:687–99.CrossRefPubMed Otter JA, Yezli S, French GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol. 2011;32:687–99.CrossRefPubMed
9.
go back to reference Weber DJ, Rutala WA, Miller MB, Huslage K, Sickbert-Bennett E. Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium Difficile, and Acinetobacter species. Am J Infect Control. 2010;38:S25–33.CrossRefPubMed Weber DJ, Rutala WA, Miller MB, Huslage K, Sickbert-Bennett E. Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium Difficile, and Acinetobacter species. Am J Infect Control. 2010;38:S25–33.CrossRefPubMed
10.
go back to reference Fekety R, Kim K-H, Brown D, Batts DH, Cudmore M, Silva J. Epidemiology of antibiotic-associated colitis: isolation of Clostridium Difficile from the hospital environment. Am J Med. 1981;70:906–8.CrossRefPubMed Fekety R, Kim K-H, Brown D, Batts DH, Cudmore M, Silva J. Epidemiology of antibiotic-associated colitis: isolation of Clostridium Difficile from the hospital environment. Am J Med. 1981;70:906–8.CrossRefPubMed
11.
go back to reference Drees M, Snydman DR, Schmid CH, Barefoot L, Hansjosten K, Vue PM, Cronin M, Nasraway SA, Golan Y. Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci. Clin Infect Dis. 2008;46:678–85.CrossRefPubMed Drees M, Snydman DR, Schmid CH, Barefoot L, Hansjosten K, Vue PM, Cronin M, Nasraway SA, Golan Y. Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci. Clin Infect Dis. 2008;46:678–85.CrossRefPubMed
12.
go back to reference Malamou-Ladas H, O'farrell S, Nash J, Tabaqchali S. Isolation of Clostridium Difficile from patients and the environment of hospital wards. J Clin Pathol. 1983;36:88–92.CrossRefPubMedPubMedCentral Malamou-Ladas H, O'farrell S, Nash J, Tabaqchali S. Isolation of Clostridium Difficile from patients and the environment of hospital wards. J Clin Pathol. 1983;36:88–92.CrossRefPubMedPubMedCentral
14.
go back to reference Shaughnessy MK, Micielli RL, DePestel DD, Arndt J, Strachan CL, Welch KB, Chenoweth CE. Evaluation of hospital room assignment and acquisition of Clostridium Difficile infection. Infect Control Hosp Epidemiol. 2011;32:201–6.CrossRefPubMed Shaughnessy MK, Micielli RL, DePestel DD, Arndt J, Strachan CL, Welch KB, Chenoweth CE. Evaluation of hospital room assignment and acquisition of Clostridium Difficile infection. Infect Control Hosp Epidemiol. 2011;32:201–6.CrossRefPubMed
15.
go back to reference Best EL, Fawley WN, Parnell P, Wilcox MH. The potential for airborne dispersal of Clostridium Difficile from symptomatic patients. Clin Infect Dis. 2010;50:1450–7.CrossRefPubMed Best EL, Fawley WN, Parnell P, Wilcox MH. The potential for airborne dispersal of Clostridium Difficile from symptomatic patients. Clin Infect Dis. 2010;50:1450–7.CrossRefPubMed
16.
go back to reference Sudharsanam S, Swaminathan S, Ramalingam A, Thangavel G, Annamalai R, Steinberg R, Balakrishnan K, Srikanth P. Characterization of indoor bioaerosols from a hospital ward in a tropical setting. Afr Health Sci. 2012;12:217–25.CrossRefPubMedPubMedCentral Sudharsanam S, Swaminathan S, Ramalingam A, Thangavel G, Annamalai R, Steinberg R, Balakrishnan K, Srikanth P. Characterization of indoor bioaerosols from a hospital ward in a tropical setting. Afr Health Sci. 2012;12:217–25.CrossRefPubMedPubMedCentral
17.
go back to reference Roberts K, Smith CF, Snelling AM, Kerr KG, Banfield KR, Sleigh PA, Beggs CB. Aerial dissemination of Clostridium Difficile spores. BMC Infect Dis. 2008;8:1.CrossRef Roberts K, Smith CF, Snelling AM, Kerr KG, Banfield KR, Sleigh PA, Beggs CB. Aerial dissemination of Clostridium Difficile spores. BMC Infect Dis. 2008;8:1.CrossRef
18.
go back to reference Li C-S, Hou P-A. Bioaerosol characteristics in hospital clean rooms. Sci Total Environ. 2003;305:169–76.CrossRefPubMed Li C-S, Hou P-A. Bioaerosol characteristics in hospital clean rooms. Sci Total Environ. 2003;305:169–76.CrossRefPubMed
19.
go back to reference Pastuszka J, Marchwinska-Wyrwal E, Wlazlo A. Bacterial aerosol in Silesian hospitals: preliminary results. Pol J Environ Stud. 2005;14:883. Pastuszka J, Marchwinska-Wyrwal E, Wlazlo A. Bacterial aerosol in Silesian hospitals: preliminary results. Pol J Environ Stud. 2005;14:883.
20.
21.
go back to reference Augustowska M, Dutkiewicz J. Variability of airborne microflora in a hospital ward within a period of one year. Ann Agric Environ Med. 2006;13:99–106.PubMed Augustowska M, Dutkiewicz J. Variability of airborne microflora in a hospital ward within a period of one year. Ann Agric Environ Med. 2006;13:99–106.PubMed
22.
go back to reference Darlow H, Bale W. Infective hazards of water-closets. Lancet. 1959;273:1196–200.CrossRef Darlow H, Bale W. Infective hazards of water-closets. Lancet. 1959;273:1196–200.CrossRef
23.
26.
go back to reference Gerba CP, Wallis C, Melnick JL. Microbiological hazards of household toilets: droplet production and the fate of residual organisms. Appl Microbiol. 1975;30:229–37.CrossRefPubMedPubMedCentral Gerba CP, Wallis C, Melnick JL. Microbiological hazards of household toilets: droplet production and the fate of residual organisms. Appl Microbiol. 1975;30:229–37.CrossRefPubMedPubMedCentral
27.
go back to reference Best EL, Sandoe J, Wilcox M. Potential for aerosolization of Clostridium Difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk. J Hosp Infect. 2012;80:1–5.CrossRefPubMed Best EL, Sandoe J, Wilcox M. Potential for aerosolization of Clostridium Difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk. J Hosp Infect. 2012;80:1–5.CrossRefPubMed
28.
go back to reference Jessen C: Luftbarne mikroorganismer forekomst og bekaempelse [in danish]. Copenhagen; 1955. Jessen C: Luftbarne mikroorganismer forekomst og bekaempelse [in danish]. Copenhagen; 1955.
29.
go back to reference Barker J, Jones M. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. J Appl Microbiol. 2005;99:339–47.CrossRefPubMed Barker J, Jones M. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. J Appl Microbiol. 2005;99:339–47.CrossRefPubMed
30.
go back to reference Macher JM. Positive-hole correction of multiple-jet impactors for collecting viable microorganisms. Ann Agric Environ Med. 1989;50:561–8. Macher JM. Positive-hole correction of multiple-jet impactors for collecting viable microorganisms. Ann Agric Environ Med. 1989;50:561–8.
31.
go back to reference ACGIH. Bioaerosols: assessment and control. ACGIH: Cincinnati; 1999. ACGIH. Bioaerosols: assessment and control. ACGIH: Cincinnati; 1999.
32.
go back to reference Hinds WC: Aerosol technology: properties, behavior, and measurement of airborne particles. 2: New York: Wiley; 1999. Hinds WC: Aerosol technology: properties, behavior, and measurement of airborne particles. 2: New York: Wiley; 1999.
33.
go back to reference Möhler O, Georgakopoulos DG, Morris CE, Benz S, Ebert V, Hunsmann S, Saathoff H, Schnaiter M, Wagner R. Heterogeneous ice nucleation activity of bacteria: new laboratory experiments at simulated cloud conditions. Biogeosciences. 2008;5:1425–35.CrossRef Möhler O, Georgakopoulos DG, Morris CE, Benz S, Ebert V, Hunsmann S, Saathoff H, Schnaiter M, Wagner R. Heterogeneous ice nucleation activity of bacteria: new laboratory experiments at simulated cloud conditions. Biogeosciences. 2008;5:1425–35.CrossRef
35.
go back to reference Willshaw GA, Thirlwell J, Jones AP, Parry S, Salmon RL, Hickey M. Vero cytotoxin-producing Escherichia Coli O157 in beefburgers linked to an outbreak of diarrhoea, haemorrhagic colitis and haemolytic uraemic syndrome in Britain. Lett Appl Microbiol. 1994;19:304–7.CrossRefPubMed Willshaw GA, Thirlwell J, Jones AP, Parry S, Salmon RL, Hickey M. Vero cytotoxin-producing Escherichia Coli O157 in beefburgers linked to an outbreak of diarrhoea, haemorrhagic colitis and haemolytic uraemic syndrome in Britain. Lett Appl Microbiol. 1994;19:304–7.CrossRefPubMed
36.
go back to reference Nonnenmann M, Bextine B, Dowd S, Gilmore K, Levin J. Culture-independent characterization of bacteria and fungi in a poultry bioaerosol using pyrosequencing: a new approach. J Occup Environ Hyg. 2010;7:693–9.CrossRefPubMed Nonnenmann M, Bextine B, Dowd S, Gilmore K, Levin J. Culture-independent characterization of bacteria and fungi in a poultry bioaerosol using pyrosequencing: a new approach. J Occup Environ Hyg. 2010;7:693–9.CrossRefPubMed
37.
go back to reference O'Brien KM, Chimenti MS, Farnell M, Tabler T, Bair T, Bray JL, Nonnenmann MW. High throughput genomic sequencing of bioaerosols in broiler chicken production facilities. Microb Biotechnol. 2016;9:782–91.CrossRefPubMedPubMedCentral O'Brien KM, Chimenti MS, Farnell M, Tabler T, Bair T, Bray JL, Nonnenmann MW. High throughput genomic sequencing of bioaerosols in broiler chicken production facilities. Microb Biotechnol. 2016;9:782–91.CrossRefPubMedPubMedCentral
Metadata
Title
Bioaerosol concentrations generated from toilet flushing in a hospital-based patient care setting
Authors
Samantha D. Knowlton
Corey L. Boles
Eli N. Perencevich
Daniel J. Diekema
Matthew W. Nonnenmann
CDC Epicenters Program
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Antimicrobial Resistance & Infection Control / Issue 1/2018
Electronic ISSN: 2047-2994
DOI
https://doi.org/10.1186/s13756-018-0301-9

Other articles of this Issue 1/2018

Antimicrobial Resistance & Infection Control 1/2018 Go to the issue