Skip to main content
Top
Published in: Systematic Reviews 1/2017

Open Access 01-12-2017 | Research

Abnormal placental cord insertion and adverse pregnancy outcomes: a systematic review and meta-analysis

Authors: Khadijah Irfah Ismail, Ailish Hannigan, Keelin O’Donoghue, Amanda Cotter

Published in: Systematic Reviews | Issue 1/2017

Login to get access

Abstract

Background

Abnormal placental cord insertion (PCI) includes marginal cord insertion (MCI) and velamentous cord insertion (VCI). VCI has been shown to be associated with adverse pregnancy outcomes. This systematic review and meta-analysis aims to determine the association of abnormal PCI and adverse pregnancy outcomes.

Methods

Embase, Medline, CINAHL, Scopus, Web of Science, ClinicalTrials.gov, and Cochrane Databases were searched in December 2016 (from inception to December 2016). The reference lists of eligible studies were scrutinized to identify further studies. Potentially eligible studies were reviewed by two authors independently using the following inclusion criteria: singleton pregnancies, velamentous cord insertion, marginal cord insertion, and pregnancy outcomes. Case reports and series were excluded. The methodological quality of the included studies was assessed using the Newcastle-Ottawa Scale. Outcomes for meta-analysis were dichotomous and results are presented as summary risk ratios with 95% confidence intervals.

Results

Seventeen studies were included in the systematic review, all of which were assessed as good quality. Normal PCI and MCI were grouped together as non-VCI and compared with VCI in seven studies. Four studies compared MCI, VCI, and normal PCI separately. Two other studies compared MCI with normal PCI, and VCI was excluded from their analysis. Studies in this systematic review reported an association between abnormal PCI, defined differently across studies, with preterm birth, small for gestational age (SGA), low birthweight (< 2500 g), emergency cesarean delivery, and intrauterine fetal death. Four cohort studies comparing MCI, VCI, and normal PCI separately were included in a meta-analysis resulting in a statistically significant increased risk of emergency cesarean delivery for VCI (pooled RR 2.86, 95% CI 1.56–5.22, P = 0.0006) and abnormal PCI (pooled RR 1.77, 95% CI 1.33–2.36, P < 0.0001) compared to normal PCI.

Conclusions

The available evidence suggests an association between abnormal PCI and emergency cesarean delivery. However, the number of studies with comparable definitions of abnormal PCI was small, limiting the analysis of other adverse pregnancy outcomes, and further research is required.
Appendix
Available only for authorised users
Literature
1.
go back to reference Baergen RN. Pathology of the Umbilical Cord, in Manual of Pathology of the Human Placenta, Second edn. New York: Springer Science & Business Media; 2011. Baergen RN. Pathology of the Umbilical Cord, in Manual of Pathology of the Human Placenta, Second edn. New York: Springer Science & Business Media; 2011.
2.
go back to reference Yampolsky M, Salafia CM, Shlakhter O, Haas D, Eucker B, Thorp J. Centrality of the umbilical cord insertion in a human placenta influences the placental efficiency. Placenta. 2009;30(12):1058–64.CrossRefPubMedPubMedCentral Yampolsky M, Salafia CM, Shlakhter O, Haas D, Eucker B, Thorp J. Centrality of the umbilical cord insertion in a human placenta influences the placental efficiency. Placenta. 2009;30(12):1058–64.CrossRefPubMedPubMedCentral
3.
go back to reference Benirschke K. Manual of pathology of the human placental. 2nd ed. New York: Spinger Science & Business Media; 2011. Benirschke K. Manual of pathology of the human placental. 2nd ed. New York: Spinger Science & Business Media; 2011.
4.
go back to reference Hubinont C, Lewi L, Bernard P, Marbaix E, Debieve F, Jauniaux E. Anomalies of the placenta and umbilical cord in twin gestations. Am J Obstet Gynecol. 2015;213(4):S91–S102.CrossRefPubMed Hubinont C, Lewi L, Bernard P, Marbaix E, Debieve F, Jauniaux E. Anomalies of the placenta and umbilical cord in twin gestations. Am J Obstet Gynecol. 2015;213(4):S91–S102.CrossRefPubMed
5.
go back to reference Nordenvall M, Sandstedt B, Ulmsten U. Relationship between placental shape, cord insertion, lobes and gestational outcome. Acta Obstet Gynecol Scand. 1988;67(7):611–6.CrossRefPubMed Nordenvall M, Sandstedt B, Ulmsten U. Relationship between placental shape, cord insertion, lobes and gestational outcome. Acta Obstet Gynecol Scand. 1988;67(7):611–6.CrossRefPubMed
6.
go back to reference Ebbing C, Kiserud T, Johnsen SL, Albrechtsen S, Rasmussen S. Prevalence, risk factors and outcomes of Velamentous and marginal cord insertions: a population-based study of 634,741 pregnancies. PLoS One. 2013;8(7):e70380.CrossRefPubMedPubMedCentral Ebbing C, Kiserud T, Johnsen SL, Albrechtsen S, Rasmussen S. Prevalence, risk factors and outcomes of Velamentous and marginal cord insertions: a population-based study of 634,741 pregnancies. PLoS One. 2013;8(7):e70380.CrossRefPubMedPubMedCentral
7.
go back to reference Esakoff TF, Cheng YW, Snowden JM, Tran SH, Shaffer BL, Caughey AB. Velamentous cord insertion: is it associated with adverse perinatal outcomes? J Matern Fetal Neonatal Med. 2015;28(4):409–12.CrossRefPubMed Esakoff TF, Cheng YW, Snowden JM, Tran SH, Shaffer BL, Caughey AB. Velamentous cord insertion: is it associated with adverse perinatal outcomes? J Matern Fetal Neonatal Med. 2015;28(4):409–12.CrossRefPubMed
8.
go back to reference Raisanen S, Georgiadis L, Harju M, Keski-Nisula L, Heinonen S. Risk factors and adverse pregnancy outcomes among births affected by velamentous umbilical cord insertion: a retrospective population-based register study. Eur J Obstet Gynecol Reprod Biol. 2012;165(2):231–4.CrossRefPubMed Raisanen S, Georgiadis L, Harju M, Keski-Nisula L, Heinonen S. Risk factors and adverse pregnancy outcomes among births affected by velamentous umbilical cord insertion: a retrospective population-based register study. Eur J Obstet Gynecol Reprod Biol. 2012;165(2):231–4.CrossRefPubMed
9.
go back to reference Uyanwah-Akpom P, Fox H. The clinical significance of marginal and velamentous insertion of the cord. Br J Obstet Gynaecol. 1977;84(12):941–3.CrossRefPubMed Uyanwah-Akpom P, Fox H. The clinical significance of marginal and velamentous insertion of the cord. Br J Obstet Gynaecol. 1977;84(12):941–3.CrossRefPubMed
10.
go back to reference Eddleman KA, Lockwood CJ, Berkowitz GS, Lapinski RH, Berkowitz RL. Clinical significance and sonographic diagnosis of velamentous umbilical cord insertion. Am J Perinatol. 1992;9(2):123–6.CrossRefPubMed Eddleman KA, Lockwood CJ, Berkowitz GS, Lapinski RH, Berkowitz RL. Clinical significance and sonographic diagnosis of velamentous umbilical cord insertion. Am J Perinatol. 1992;9(2):123–6.CrossRefPubMed
11.
go back to reference Vahanian SA, Lavery JA, Ananth CV, Vintzileos A. Placental implantation abnormalities and risk of preterm delivery: a systematic review and metaanalysis. Am J Obstet Gynecol. 2015;213(4):S78–90.CrossRefPubMed Vahanian SA, Lavery JA, Ananth CV, Vintzileos A. Placental implantation abnormalities and risk of preterm delivery: a systematic review and metaanalysis. Am J Obstet Gynecol. 2015;213(4):S78–90.CrossRefPubMed
12.
go back to reference Wells GA, Shea B, O’Connell D, Peterson J, Welch V, Losos M, Tugwell P. The Newcastle-Ottawa scale (NOS) for assesssing the quality of nonrandomized studies in meta-analyses. Ottawa: Ottawa Hospital Research Institute. Wells GA, Shea B, O’Connell D, Peterson J, Welch V, Losos M, Tugwell P. The Newcastle-Ottawa scale (NOS) for assesssing the quality of nonrandomized studies in meta-analyses. Ottawa: Ottawa Hospital Research Institute.
13.
go back to reference Huguet A, Hayden JA, Stinson J, McGrath PJ, Chambers CT, Tougas ME, Wozney L. Judging the quality of evidence in reviews of prognostic factor research: adapting the GRADE framework. Syst Rev. 2013;2:71.CrossRefPubMedPubMedCentral Huguet A, Hayden JA, Stinson J, McGrath PJ, Chambers CT, Tougas ME, Wozney L. Judging the quality of evidence in reviews of prognostic factor research: adapting the GRADE framework. Syst Rev. 2013;2:71.CrossRefPubMedPubMedCentral
14.
go back to reference Burke G, Saunders J, Gabathuse T, Fahy U, Slevin J, Abu H. The significance of umbilical cord insertion in term singleton pregnancies. Am J Obstet Gynecol. 2011;204(1):S60–1. Burke G, Saunders J, Gabathuse T, Fahy U, Slevin J, Abu H. The significance of umbilical cord insertion in term singleton pregnancies. Am J Obstet Gynecol. 2011;204(1):S60–1.
15.
go back to reference Pinar H, Goldenberg RL, Koch MA, Heim-Hall J, Hawkins HK, Shehata B, Abramowsky C, Parker CB, Dudley DJ, Silver RM, et al. Placental findings in singleton stillbirths. Obstet Gynecol. 2014;123(2 Pt 1):325–36.CrossRefPubMedPubMedCentral Pinar H, Goldenberg RL, Koch MA, Heim-Hall J, Hawkins HK, Shehata B, Abramowsky C, Parker CB, Dudley DJ, Silver RM, et al. Placental findings in singleton stillbirths. Obstet Gynecol. 2014;123(2 Pt 1):325–36.CrossRefPubMedPubMedCentral
16.
go back to reference Tantbirojn P, Saleemuddin A, Sirois K, Crum CP, Boyd TK, Tworoger S, Parast MM. Gross abnormalities of the umbilical cord: related placental histology and clinical significance. Placenta. 2009;30(12):1083–8.CrossRefPubMed Tantbirojn P, Saleemuddin A, Sirois K, Crum CP, Boyd TK, Tworoger S, Parast MM. Gross abnormalities of the umbilical cord: related placental histology and clinical significance. Placenta. 2009;30(12):1083–8.CrossRefPubMed
17.
go back to reference Feldman D, Koning K, Bobrowski R, Borgida A, Ingardia C. Clinical implications of prenatally diagnosed marginal placental cord insertion. Am J Obstet Gynecol. 2004;191(6):S176.CrossRef Feldman D, Koning K, Bobrowski R, Borgida A, Ingardia C. Clinical implications of prenatally diagnosed marginal placental cord insertion. Am J Obstet Gynecol. 2004;191(6):S176.CrossRef
18.
go back to reference Hasegawa J, Matsuoka R, Ichizuka K, Otsuki K, Sekizawa A, Farina A, Okai T. Cord insertion into the lower third of the uterus in the first trimester is associated with placental and umbilical cord abnormalities. Ultrasound Obstet Gynecol. 2006;28(2):183–6.CrossRefPubMed Hasegawa J, Matsuoka R, Ichizuka K, Otsuki K, Sekizawa A, Farina A, Okai T. Cord insertion into the lower third of the uterus in the first trimester is associated with placental and umbilical cord abnormalities. Ultrasound Obstet Gynecol. 2006;28(2):183–6.CrossRefPubMed
19.
go back to reference Hasegawa J, Matsuoka R, Ichizuka K, Kotani M, Nakamura M, Mikoshiba T, Sekizawa A, Okai T. Atypical variable deceleration in the first stage of labor is a characteristic fetal heart-rate pattern for velamentous cord insertion and hypercoiled cord. J Obstet Gynaecol Res. 2009;35(1):35–9.CrossRefPubMed Hasegawa J, Matsuoka R, Ichizuka K, Kotani M, Nakamura M, Mikoshiba T, Sekizawa A, Okai T. Atypical variable deceleration in the first stage of labor is a characteristic fetal heart-rate pattern for velamentous cord insertion and hypercoiled cord. J Obstet Gynaecol Res. 2009;35(1):35–9.CrossRefPubMed
20.
go back to reference Heinonen S, Ryynanen M, Kirkinen P, Saarikoski S. Perinatal diagnostic evaluation of velamentous umbilical cord insertion: clinical, Doppler, and ultrasonic findings. Obstet Gynecol. 1996;87(1):112–7.CrossRefPubMed Heinonen S, Ryynanen M, Kirkinen P, Saarikoski S. Perinatal diagnostic evaluation of velamentous umbilical cord insertion: clinical, Doppler, and ultrasonic findings. Obstet Gynecol. 1996;87(1):112–7.CrossRefPubMed
21.
go back to reference Suzuki S, Kato M. Clinical significance of pregnancies complicated by Velamentous umbilical cord insertion associated with other umbilical cord/placental abnormalities. J Clin Med Res. 2015;7(11):853–6.CrossRefPubMedPubMedCentral Suzuki S, Kato M. Clinical significance of pregnancies complicated by Velamentous umbilical cord insertion associated with other umbilical cord/placental abnormalities. J Clin Med Res. 2015;7(11):853–6.CrossRefPubMedPubMedCentral
22.
go back to reference Yerlikaya G, Pils S, Springer S, Chalubinski K, Ott J. Velamentous cord insertion as a risk factor for obstetric outcome: a retrospective case-control study. Arch Gynecol Obstet. 2016;293(5):975–81.CrossRefPubMed Yerlikaya G, Pils S, Springer S, Chalubinski K, Ott J. Velamentous cord insertion as a risk factor for obstetric outcome: a retrospective case-control study. Arch Gynecol Obstet. 2016;293(5):975–81.CrossRefPubMed
23.
go back to reference Carbone J, Feldman D, Lazarus S, Borgida A. Clinical implications of prenatally diagnosed marginal placental cord insertion. Am J Obstet Gynecol. 2008;199(6):S187.CrossRef Carbone J, Feldman D, Lazarus S, Borgida A. Clinical implications of prenatally diagnosed marginal placental cord insertion. Am J Obstet Gynecol. 2008;199(6):S187.CrossRef
24.
go back to reference Boulis TS, Rochelson B, Meirowitz N, Fleischer A, Smith-Levitin M, Edelman M, Rosen L, Williamson A, Vohra N. Is velamentous/marginal cord insertion associated with adverse outcomes in singletons? Am J Obstet Gynecol. 2013;208(1):S79. Boulis TS, Rochelson B, Meirowitz N, Fleischer A, Smith-Levitin M, Edelman M, Rosen L, Williamson A, Vohra N. Is velamentous/marginal cord insertion associated with adverse outcomes in singletons? Am J Obstet Gynecol. 2013;208(1):S79.
25.
go back to reference Brouillet S, Dufour A, Prot F, Feige JJ, Equy V, Alfaidy N, Gillois P, Hoffmann P. Influence of the umbilical cord insertion site on the optimal individual birth weight achievement. Biomed Res Int. 2014;2014:8. Brouillet S, Dufour A, Prot F, Feige JJ, Equy V, Alfaidy N, Gillois P, Hoffmann P. Influence of the umbilical cord insertion site on the optimal individual birth weight achievement. Biomed Res Int. 2014;2014:8.
26.
go back to reference Salomon LJ, Alfirevic Z, Berghella V, Bilardo C, Hernandez-Andrade E, Johnsen SL, Kalache K, Leung KY, Malinger G, Munoz H, et al. Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol. 2011;37(1):116–26.CrossRefPubMed Salomon LJ, Alfirevic Z, Berghella V, Bilardo C, Hernandez-Andrade E, Johnsen SL, Kalache K, Leung KY, Malinger G, Munoz H, et al. Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol. 2011;37(1):116–26.CrossRefPubMed
27.
go back to reference Salomon LJ, Alfirevic Z, Bilardo CM, Chalouhi GE, Ghi T, Kagan KO, Lau TK, Papageorghiou AT, Raine-Fenning NJ, Stirnemann J, et al. ISUOG practice guidelines: performance of first-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol. 2013;41(1):102–13.CrossRefPubMed Salomon LJ, Alfirevic Z, Bilardo CM, Chalouhi GE, Ghi T, Kagan KO, Lau TK, Papageorghiou AT, Raine-Fenning NJ, Stirnemann J, et al. ISUOG practice guidelines: performance of first-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol. 2013;41(1):102–13.CrossRefPubMed
28.
go back to reference AIUM. AIUM practice guideline for the performance of obstetric ultrasound examinations. J Ultrasound Med. 2013;32(6):1083–101.CrossRef AIUM. AIUM practice guideline for the performance of obstetric ultrasound examinations. J Ultrasound Med. 2013;32(6):1083–101.CrossRef
Metadata
Title
Abnormal placental cord insertion and adverse pregnancy outcomes: a systematic review and meta-analysis
Authors
Khadijah Irfah Ismail
Ailish Hannigan
Keelin O’Donoghue
Amanda Cotter
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Systematic Reviews / Issue 1/2017
Electronic ISSN: 2046-4053
DOI
https://doi.org/10.1186/s13643-017-0641-1

Other articles of this Issue 1/2017

Systematic Reviews 1/2017 Go to the issue