Skip to main content
Top
Published in: EJNMMI Research 1/2018

Open Access 01-12-2018 | Original research

The value of 99mTc-MAA SPECT/CT for lung shunt estimation in 90Y radioembolization: a phantom and patient study

Authors: Jonathan D. Allred, Jeremy Niedbala, Justin K. Mikell, Dawn Owen, Kirk A. Frey, Yuni K. Dewaraja

Published in: EJNMMI Research | Issue 1/2018

Login to get access

Abstract

Background

A major toxicity concern in radioembolization therapy of hepatic malignancies is radiation-induced pneumonitis and sclerosis due to hepatopulmonary shunting of 90Y microspheres. Currently, 99mTc macroaggregated albumin (99mTc-MAA) imaging is used to estimate the lung shunt fraction (LSF) prior to treatment. The aim of this study was to evaluate the accuracy/precision of LSF estimated from 99mTc planar and SPECT/CT phantom imaging, and within this context, to compare the corresponding LSF and lung-absorbed dose values from 99mTc-MAA patient studies. Additionally, LSFs from pre- and post-therapy imaging were compared.

Results

A liver/lung torso phantom filled with 99mTc to achieve three lung shunt values was scanned by planar and SPECT/CT imaging with repeat acquisitions to assess accuracy and precision. To facilitate processing of patient data, a workflow that relies on SPECT and CT-based auto-contouring to define liver and lung volumes for the LSF calculation was implemented. Planar imaging-based LSF estimates for 40 patients, obtained from their medical records, were retrospectively compared with SPECT/CT imaging-based calculations with attenuation and scatter correction. Additionally, in a subset of 20 patients, the pre-therapy estimates were compared with 90Y PET/CT-based measurements.
In the phantom study, improved accuracy in LSF estimation was achieved using SPECT/CT with attenuation and scatter correction (within 13% of the true value) compared with planar imaging (up to 44% overestimation). The results in patients showed a similar trend with planar imaging significantly overestimating LSF compared to SPECT/CT. There was no correlation between lung shunt estimates and the delay between 99mTc-MAA administration and scanning, but off-target extra hepatic uptake tended to be more likely in patients with a longer delay. The mean lung absorbed dose predictions for the 28 patients who underwent therapy was 9.3 Gy (range 1.3–29.4) for planar imaging and 3.2 Gy (range 0.4–13.4) for SPECT/CT. For the patients with post-therapy imaging, the mean LSF from 90Y PET/CT was 1.0%, (range 0.3–2.8). This value was not significantly different from the mean LSF estimate from 99mTc-MAA SPECT/CT (mean 1.0%, range 0.4–1.6; p = 0.968), but was significantly lower than the mean LSF estimate based on planar imaging (mean 4.1%, range 1.2–15.0; p = 0.0002).

Conclusions

The improved accuracy demonstrated by the phantom study, agreement with 90Y PET/CT in patient studies, and the practicality of using auto-contouring for liver/lung definition suggests that 99mTc-MAA SPECT/CT with scatter and attenuation corrections should be used for lung shunt estimation prior to radioembolization.
Literature
1.
go back to reference Salem R, Lewandowski RJ, Kulik L, et al. Radioembolization results in longer time-to progression and reduced toxicity compared with chemoembolization in patients with hepatocellular carcinoma. Gastroenterology. 2011;140(2):497–507.CrossRefPubMed Salem R, Lewandowski RJ, Kulik L, et al. Radioembolization results in longer time-to progression and reduced toxicity compared with chemoembolization in patients with hepatocellular carcinoma. Gastroenterology. 2011;140(2):497–507.CrossRefPubMed
2.
go back to reference Edeline J, Crouzet L, Campillo-Gimenez B, et al. Selective internal radiation therapy compared with sorafenib for hepatocellular carcinoma with portal vein thrombosis. Eur J Nucl Med Mol Imaging. 2016;43:635–43.CrossRefPubMed Edeline J, Crouzet L, Campillo-Gimenez B, et al. Selective internal radiation therapy compared with sorafenib for hepatocellular carcinoma with portal vein thrombosis. Eur J Nucl Med Mol Imaging. 2016;43:635–43.CrossRefPubMed
3.
go back to reference Leung TW, Lau WY, Ho SK, et al. Radiation pneumonitis after selective internal radiation treatment with intraarterial 90yttrium-microspheres for inoperable hepatic tumors. Int J Radiat Oncol Biol Phys. 1995;33:919–24.CrossRefPubMed Leung TW, Lau WY, Ho SK, et al. Radiation pneumonitis after selective internal radiation treatment with intraarterial 90yttrium-microspheres for inoperable hepatic tumors. Int J Radiat Oncol Biol Phys. 1995;33:919–24.CrossRefPubMed
4.
go back to reference Ho S, Lau WY, Leung TW, Chan M, et al. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer. Eur J Nucl Med. 1997;24:293–8.PubMed Ho S, Lau WY, Leung TW, Chan M, et al. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer. Eur J Nucl Med. 1997;24:293–8.PubMed
5.
go back to reference Yu N, Srinivas SM, Difilippo FP, Shrikanthan S, et al. Lung dose calculation with SPECT/CT for 90Yittrium radioembolization of liver cancer. Int J Radiat Oncol Biol Phys. 2013;85:834–9.CrossRefPubMed Yu N, Srinivas SM, Difilippo FP, Shrikanthan S, et al. Lung dose calculation with SPECT/CT for 90Yittrium radioembolization of liver cancer. Int J Radiat Oncol Biol Phys. 2013;85:834–9.CrossRefPubMed
6.
go back to reference Kao YH, Magsombol BM, Toh Y, et al. Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization. EJNMMI Res. 2014;4:33.CrossRefPubMedPubMedCentral Kao YH, Magsombol BM, Toh Y, et al. Personalized predictive lung dosimetry by technetium-99m macroaggregated albumin SPECT/CT for yttrium-90 radioembolization. EJNMMI Res. 2014;4:33.CrossRefPubMedPubMedCentral
7.
go back to reference Dittmann HJMH, Kopp D, Kupferschlaeger J, Feil D, Groezinger G, Syha R, Weissinger M, La Fougère C. A prospective study of quantitative SPECT/CT for evaluation of hepatopulmonary shunt fraction prior to SIRT of liver tumors. J Nucl Med. 2018; https://doi.org/10.2967/jnumed.117.205203. [Epub ahead of print] PubMed PMID: 29371406 Dittmann HJMH, Kopp D, Kupferschlaeger J, Feil D, Groezinger G, Syha R, Weissinger M, La Fougère C. A prospective study of quantitative SPECT/CT for evaluation of hepatopulmonary shunt fraction prior to SIRT of liver tumors. J Nucl Med. 2018; https://​doi.​org/​10.​2967/​jnumed.​117.​205203. [Epub ahead of print] PubMed PMID: 29371406
8.
go back to reference Willowson KP, Tapner M, QUEST Investigator Team, Bailey DL. A multicenter comparison of quantitative (90)Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: the QUEST Phantom Study. Eur J Nucl Med Mol Imaging. 2015;42(8):1202–22.CrossRefPubMedPubMedCentral Willowson KP, Tapner M, QUEST Investigator Team, Bailey DL. A multicenter comparison of quantitative (90)Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: the QUEST Phantom Study. Eur J Nucl Med Mol Imaging. 2015;42(8):1202–22.CrossRefPubMedPubMedCentral
9.
go back to reference Elschot M, Lam MG, van den Bosch MA, Viergever MA, de Jong HW. Quantitative Monte Carlo-based 90Y SPECT reconstruction. J Nucl Med. 2013;54:1557–63.CrossRefPubMed Elschot M, Lam MG, van den Bosch MA, Viergever MA, de Jong HW. Quantitative Monte Carlo-based 90Y SPECT reconstruction. J Nucl Med. 2013;54:1557–63.CrossRefPubMed
10.
go back to reference Rong X, Du Y, Ljungberg M, Rault E, Vandenberghe S, Frey EC. Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method. Med Phys. 2012;39(5):2346–58.CrossRefPubMedPubMedCentral Rong X, Du Y, Ljungberg M, Rault E, Vandenberghe S, Frey EC. Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method. Med Phys. 2012;39(5):2346–58.CrossRefPubMedPubMedCentral
11.
go back to reference Dewaraja YK, Chun SY. Srinivasa et al. improved quantitative (90) Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling. Med Phys. 2017;44(12):6364–76.CrossRefPubMed Dewaraja YK, Chun SY. Srinivasa et al. improved quantitative (90) Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling. Med Phys. 2017;44(12):6364–76.CrossRefPubMed
12.
go back to reference Bailey JJ, Dewaraja Y, Hubers D, Srinivasa R, Frey KA. Biodistribution of 99m99mTc-MAA on SPECT/CT performed for 90Y-radioembolization therapy planning: a pictorial review. Clin Transl Imaging. 2017;5:473–85.CrossRefPubMedPubMedCentral Bailey JJ, Dewaraja Y, Hubers D, Srinivasa R, Frey KA. Biodistribution of 99m99mTc-MAA on SPECT/CT performed for 90Y-radioembolization therapy planning: a pictorial review. Clin Transl Imaging. 2017;5:473–85.CrossRefPubMedPubMedCentral
13.
go back to reference De Gersem R, Maleux G, Vanbilloen H, Baete K, Verslype C, Haustermans K, Verbruggen A, Van Cutsem E, Deroose CM. Influence of time delay on the estimated lung shunt fraction on 99mTc-labeled MAA scintigraphy for 90Y microsphere treatment planning. Clin Nucl Med. 2013;38(12):940–2.PubMed De Gersem R, Maleux G, Vanbilloen H, Baete K, Verslype C, Haustermans K, Verbruggen A, Van Cutsem E, Deroose CM. Influence of time delay on the estimated lung shunt fraction on 99mTc-labeled MAA scintigraphy for 90Y microsphere treatment planning. Clin Nucl Med. 2013;38(12):940–2.PubMed
14.
go back to reference Dezarn WA, Cessna JT, DeWerd LA, et al. American Association of Physicists in Medicine. Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies. Med Phys. 2011;38(8):4824–45.CrossRefPubMed Dezarn WA, Cessna JT, DeWerd LA, et al. American Association of Physicists in Medicine. Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies. Med Phys. 2011;38(8):4824–45.CrossRefPubMed
15.
go back to reference Van Dyk J, Keane TJ, Rider WD. Lung density as measured by computerized tomography: implications for radiotherapy. Int J Radiat Oncol Biol Phys. 1982;8:1363–72.CrossRefPubMed Van Dyk J, Keane TJ, Rider WD. Lung density as measured by computerized tomography: implications for radiotherapy. Int J Radiat Oncol Biol Phys. 1982;8:1363–72.CrossRefPubMed
16.
go back to reference Dewaraja YK, Novelli PM, Fessler JA, et al. 90Y imaging for dosimetry in radioembolization: comparison between scatter corrected bremsstrahlung SPECT/CT and time-of-flight PET/CT [abstract]. Eur J Nucl Med Mol Imaging. 2015;42:S156. Dewaraja YK, Novelli PM, Fessler JA, et al. 90Y imaging for dosimetry in radioembolization: comparison between scatter corrected bremsstrahlung SPECT/CT and time-of-flight PET/CT [abstract]. Eur J Nucl Med Mol Imaging. 2015;42:S156.
17.
go back to reference Lim H, Dewaraja Y. Impact of Tc-99m SPECT reconstruction methods on lung shunt and lesion/normal liver activity quantification in radioembolization. J Nucl Med. 2017;58(Supp):1302. Lim H, Dewaraja Y. Impact of Tc-99m SPECT reconstruction methods on lung shunt and lesion/normal liver activity quantification in radioembolization. J Nucl Med. 2017;58(Supp):1302.
18.
go back to reference Xiao J, de Wit TC, Staelens SG, Beekman FJ. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT. J Nucl Med. 2006;47(10):1662–9.PubMed Xiao J, de Wit TC, Staelens SG, Beekman FJ. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT. J Nucl Med. 2006;47(10):1662–9.PubMed
19.
go back to reference Dewaraja YK, Ljungberg M, Fessler JA. 3-D Monte Carlo-based scatter compensation in quantitative I-131 SPECT reconstruction. IEEE Trans Nucl Sci. 2006;53(1):181.CrossRefPubMedPubMedCentral Dewaraja YK, Ljungberg M, Fessler JA. 3-D Monte Carlo-based scatter compensation in quantitative I-131 SPECT reconstruction. IEEE Trans Nucl Sci. 2006;53(1):181.CrossRefPubMedPubMedCentral
20.
go back to reference Margolis LW, Philips TL. Whole lung irradiation for metastatic tumour. Radiology. 1969;93:1173–8.CrossRefPubMed Margolis LW, Philips TL. Whole lung irradiation for metastatic tumour. Radiology. 1969;93:1173–8.CrossRefPubMed
21.
go back to reference Elschot M, Nijsen JF, Lam MG, Smits ML, et al. (99m)99mTc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with 166Ho-microspheres. Eur J Nucl Med Mol Imaging. 2014;41(10):1965–75.CrossRefPubMed Elschot M, Nijsen JF, Lam MG, Smits ML, et al. (99m)99mTc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with 166Ho-microspheres. Eur J Nucl Med Mol Imaging. 2014;41(10):1965–75.CrossRefPubMed
22.
go back to reference Olesen OV, Svarer C, Sibomana M, et al. A movable phantom design for quantitative evaluation of motion correction studies on high resolution PET scanners. IEEE Trans Nucl Sci. 2010;57:1116–24.CrossRef Olesen OV, Svarer C, Sibomana M, et al. A movable phantom design for quantitative evaluation of motion correction studies on high resolution PET scanners. IEEE Trans Nucl Sci. 2010;57:1116–24.CrossRef
Metadata
Title
The value of 99mTc-MAA SPECT/CT for lung shunt estimation in 90Y radioembolization: a phantom and patient study
Authors
Jonathan D. Allred
Jeremy Niedbala
Justin K. Mikell
Dawn Owen
Kirk A. Frey
Yuni K. Dewaraja
Publication date
01-12-2018
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2018
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-018-0402-8

Other articles of this Issue 1/2018

EJNMMI Research 1/2018 Go to the issue