Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2019

Open Access 01-12-2019 | Clavicle Fracture | Case report

Mechanical failure of plate breakage after open reduction and plate fixation of displaced midshaft clavicle fracture – a possible new risk factor: a case report

Authors: Ron Batash, Ronen Debi, Dan Grinberg, Maayan Shema, Avi Elbaz, Yeshaiau Benedict

Published in: Journal of Medical Case Reports | Issue 1/2019

Login to get access

Abstract

Background

Plate breakage is one form of construct failure after a clavicle fracture treated with an open reduction and plate fixation. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6.9% of which 1.9% were related to broken plates. Plate breakage is rare, thus, there are insufficient data regarding risk factors, pathogenesis, or how to avoid it.

Case presentation

This case report presents an unusual case of a 35-year-old Caucasian man, 7 weeks after open reduction and internal plate fixation of a fracture in the middle third of his clavicle, who developed breakage of the implant. Surgery was advised, the implant was retrieved, the fracture was reduced, and a new bridging locking plate was implanted.

Conclusions

In the current case it seems that the use of a bridging plate, the fundamental anatomical structure of the clavicle and the forces that are applied on it, the lack of discipline in complying with the postoperative functional restrictions, and an unclear “patient expectation” process were the main reasons for the failure. These aspects should be carefully considered and addressed in clavicle fractures.
Literature
1.
go back to reference Nordqvist A, Petersson C. The incidence of fractures of the clavicle. Clin Orthop Relat Res. 1994;300:127–32. Nordqvist A, Petersson C. The incidence of fractures of the clavicle. Clin Orthop Relat Res. 1994;300:127–32.
2.
go back to reference Paladini P, Pellegrini A, Merolla G, Campi F, Porcellini G. Treatment of clavicle fractures. Transl Med UniSa. 2012;2:47–58.PubMedPubMedCentral Paladini P, Pellegrini A, Merolla G, Campi F, Porcellini G. Treatment of clavicle fractures. Transl Med UniSa. 2012;2:47–58.PubMedPubMedCentral
3.
go back to reference van der Meijden OA, Gaskill TR, Millett PJ. Treatment of clavicle fractures: current concepts review. J Shoulder Elb Surg. 2012;21(3):423–9.CrossRef van der Meijden OA, Gaskill TR, Millett PJ. Treatment of clavicle fractures: current concepts review. J Shoulder Elb Surg. 2012;21(3):423–9.CrossRef
4.
go back to reference Jupiter JB, Leffert RD. Non-union of the clavicle. Associated complications and surgical management. J Bone Joint Surg Am. 1987;69(5):753–60.PubMedCrossRef Jupiter JB, Leffert RD. Non-union of the clavicle. Associated complications and surgical management. J Bone Joint Surg Am. 1987;69(5):753–60.PubMedCrossRef
5.
go back to reference Robinson CM, Goudie EB, Murray IR, Jenkins PJ, Ahktar MA, Read EO, et al. Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am. 2013;95(17):1576–84.PubMedCrossRef Robinson CM, Goudie EB, Murray IR, Jenkins PJ, Ahktar MA, Read EO, et al. Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am. 2013;95(17):1576–84.PubMedCrossRef
6.
go back to reference Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg Am. 2004;86-A(7):1359–65.PubMedCrossRef Robinson CM, Court-Brown CM, McQueen MM, Wakefield AE. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg Am. 2004;86-A(7):1359–65.PubMedCrossRef
7.
go back to reference Meeuwis MA, Pull Ter Gunne AF, Verhofstad MH, van der Heijden FH. Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures. Injury. 2017;48(3):715–9.PubMedCrossRef Meeuwis MA, Pull Ter Gunne AF, Verhofstad MH, van der Heijden FH. Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures. Injury. 2017;48(3):715–9.PubMedCrossRef
8.
go back to reference Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD, Group E-BOTW. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma. 2005;19(7):504–7.PubMedCrossRef Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD, Group E-BOTW. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma. 2005;19(7):504–7.PubMedCrossRef
9.
go back to reference Woltz S, Duijff JW, Hoogendoorn JM, Rhemrev SJ, Breederveld RS, Schipper IB, et al. Reconstruction plates for midshaft clavicular fractures: A retrospective cohort study. Orthop Traumatol Surg Res. 2016;102(1):25–9.PubMedCrossRef Woltz S, Duijff JW, Hoogendoorn JM, Rhemrev SJ, Breederveld RS, Schipper IB, et al. Reconstruction plates for midshaft clavicular fractures: A retrospective cohort study. Orthop Traumatol Surg Res. 2016;102(1):25–9.PubMedCrossRef
10.
go back to reference Gilde AK, Jones CB, Sietsema DL, Hoffmann MF. Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study. J Orthop Surg Res. 2014;9:55.PubMedPubMedCentralCrossRef Gilde AK, Jones CB, Sietsema DL, Hoffmann MF. Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study. J Orthop Surg Res. 2014;9:55.PubMedPubMedCentralCrossRef
11.
go back to reference Hulsmans MH, van Heijl M, Houwert RM, Hammacher ER, Meylaerts SA, Verhofstad MH, et al. High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures. Clin Orthop Relat Res. 2017;475(2):532–9.PubMedCrossRef Hulsmans MH, van Heijl M, Houwert RM, Hammacher ER, Meylaerts SA, Verhofstad MH, et al. High Irritation and Removal Rates After Plate or Nail Fixation in Patients With Displaced Midshaft Clavicle Fractures. Clin Orthop Relat Res. 2017;475(2):532–9.PubMedCrossRef
12.
go back to reference Wijdicks FJ, Van der Meijden OA, Millett PJ, Verleisdonk EJ, Houwert RM. Systematic review of the complications of plate fixation of clavicle fractures. Arch Orthop Trauma Surg. 2012;132(5):617–25.PubMedPubMedCentralCrossRef Wijdicks FJ, Van der Meijden OA, Millett PJ, Verleisdonk EJ, Houwert RM. Systematic review of the complications of plate fixation of clavicle fractures. Arch Orthop Trauma Surg. 2012;132(5):617–25.PubMedPubMedCentralCrossRef
13.
go back to reference Navarro RA, Gelber JD, Harrast JJ, Seiler JG, Jackson KR, Garcia IA. Frequency and complications after operative fixation of clavicular fractures. J Shoulder Elb Surg. 2016;25(5):e125–9.CrossRef Navarro RA, Gelber JD, Harrast JJ, Seiler JG, Jackson KR, Garcia IA. Frequency and complications after operative fixation of clavicular fractures. J Shoulder Elb Surg. 2016;25(5):e125–9.CrossRef
14.
go back to reference Marinescu R, Antoniac VI, Stoia DI, Lăptoiu DC. Clavicle anatomical osteosynthesis plate breakage - failure analysis report based on patient morphological parameters. Romanian J Morphol Embryol. 2017;58(2):593–8. Marinescu R, Antoniac VI, Stoia DI, Lăptoiu DC. Clavicle anatomical osteosynthesis plate breakage - failure analysis report based on patient morphological parameters. Romanian J Morphol Embryol. 2017;58(2):593–8.
15.
go back to reference Shin SJ, Do NH, Jang KY. Risk factors for postoperative complications of displaced clavicular midshaft fractures. J Trauma Acute Care Surg. 2012;72(4):1046–50.PubMedCrossRef Shin SJ, Do NH, Jang KY. Risk factors for postoperative complications of displaced clavicular midshaft fractures. J Trauma Acute Care Surg. 2012;72(4):1046–50.PubMedCrossRef
16.
go back to reference Harnroongroj T, Tantikul C, Keatkor S. The clavicular fracture: a biomechanical study of the mechanism of clavicular fracture and modes of the fracture. J Med Assoc Thail. 2000;83(6):663–7. Harnroongroj T, Tantikul C, Keatkor S. The clavicular fracture: a biomechanical study of the mechanism of clavicular fracture and modes of the fracture. J Med Assoc Thail. 2000;83(6):663–7.
17.
go back to reference Waljee J, McGlinn EP, Sears ED, Chung KC. Patient expectations and patient-reported outcomes in surgery: a systematic review. Surgery. 2014;155(5):799–808.PubMedCrossRef Waljee J, McGlinn EP, Sears ED, Chung KC. Patient expectations and patient-reported outcomes in surgery: a systematic review. Surgery. 2014;155(5):799–808.PubMedCrossRef
Metadata
Title
Mechanical failure of plate breakage after open reduction and plate fixation of displaced midshaft clavicle fracture – a possible new risk factor: a case report
Authors
Ron Batash
Ronen Debi
Dan Grinberg
Maayan Shema
Avi Elbaz
Yeshaiau Benedict
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2019
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-019-2046-3

Other articles of this Issue 1/2019

Journal of Medical Case Reports 1/2019 Go to the issue