Abstract

Background

This case report presents the treatment of a large infected skin defect, which was caused by an accidental explosion, through a skin-stretching device combined with vacuum sealing drainage. To the best of our knowledge, the area of the wound that we treated may currently be the largest.

Case presentation

A 41-year-old Asian man was transferred to the Center of Trauma Surgery of our hospital for the closure of an open infected wound with a large skin defect in his right lower limb caused by an accidental explosion of 100 pieces of blasting cap. The wounds located in his right gluteal were approximately 40 cm × 35 cm. On admission, the wounds had hemorrhaged, exhibiting a darkened appearance, and included scattered metallic foreign bodies. Debridement of his right gluteal area was conducted 6 hours after injury. Subsequently, a skin-stretching device combined with vacuum sealing drainage was applied to reduce the skin defect. This treatment proved to be valuable for the closure of the skin defect and to attain successful functional rehabilitation without sciatic nerve entrapment or amputation in this case.

Conclusions

It is difficult to close large skin defects, especially when they are infected. The application of a skin-stretching device combined with vacuum sealing drainage should be commonly applied to treat infected wounds because it is a safe and easy operative technique.
Literature
1.
go back to reference Har-Shai Y, Ullmann Y, Reis ND, et al. Closure of an open high below-knee guillotine amputation wound using a skin-stretching device. Injury. 1995;26:401–4.CrossRefPubMed Har-Shai Y, Ullmann Y, Reis ND, et al. Closure of an open high below-knee guillotine amputation wound using a skin-stretching device. Injury. 1995;26:401–4.CrossRefPubMed
2.
go back to reference Joethy J, Sebastin SJ, Chong KS, et al. Effect of negative-pressure wound therapy on open fractures of the lower limb. Singapore Med J. 2013;54(11):6204523.CrossRef Joethy J, Sebastin SJ, Chong KS, et al. Effect of negative-pressure wound therapy on open fractures of the lower limb. Singapore Med J. 2013;54(11):6204523.CrossRef
3.
go back to reference Fonder MA, Lazaruse GS, Cowan DA, et al. Treating the chronic wound: A practical approach to the care of nonhealing wounds and wound care dressings. J Am Acad Dermatol. 2008;58:185–7.CrossRefPubMed Fonder MA, Lazaruse GS, Cowan DA, et al. Treating the chronic wound: A practical approach to the care of nonhealing wounds and wound care dressings. J Am Acad Dermatol. 2008;58:185–7.CrossRefPubMed
4.
go back to reference Bostrom B, Wilson H, Radlinsky MA. The use of an external skin-stretching device for wound management in a rabbit. J Exotic Pet Med. 2006;15:145–9.CrossRef Bostrom B, Wilson H, Radlinsky MA. The use of an external skin-stretching device for wound management in a rabbit. J Exotic Pet Med. 2006;15:145–9.CrossRef
5.
go back to reference Rivera AE, Spencer JM. Clinical aspects of full-thickness wound healing. Clin Dermatol. 2007;25:39–48.CrossRefPubMed Rivera AE, Spencer JM. Clinical aspects of full-thickness wound healing. Clin Dermatol. 2007;25:39–48.CrossRefPubMed
6.
go back to reference Baird R, Gholoum S, Laberge J-M, et al. Management of a giant omphalocele with an external skin closure system. J Pediatric Surg. 2010;45:17–20.CrossRef Baird R, Gholoum S, Laberge J-M, et al. Management of a giant omphalocele with an external skin closure system. J Pediatric Surg. 2010;45:17–20.CrossRef
7.
go back to reference Har-Shai Y, Hirshowitz B. The use of a modified skin stretching device (SSD) together with a lower cheek and neck flap for coverage of a large cheek skin defect. Eur J Plast Surg. 1995;18:136–8. Har-Shai Y, Hirshowitz B. The use of a modified skin stretching device (SSD) together with a lower cheek and neck flap for coverage of a large cheek skin defect. Eur J Plast Surg. 1995;18:136–8.
8.
go back to reference Verhaegen PD, van der Wal MB, Bloemen MC, et al. Sustainable effect of skin stretching for burn scar excision: long-term results of a multicenter randomized controlled trial. Burn. 2011;37:1222–8.CrossRef Verhaegen PD, van der Wal MB, Bloemen MC, et al. Sustainable effect of skin stretching for burn scar excision: long-term results of a multicenter randomized controlled trial. Burn. 2011;37:1222–8.CrossRef
9.
go back to reference Daya M, Nair V. Traction-assisted dermatogenesis by serial intermittent skin tape application. Plast Reconstr Surg. 2008;122:1047–54.CrossRefPubMed Daya M, Nair V. Traction-assisted dermatogenesis by serial intermittent skin tape application. Plast Reconstr Surg. 2008;122:1047–54.CrossRefPubMed
Metadata
Title
The use of a skin-stretching device combined with vacuum sealing drainage for closure of a large skin defect: a case report
Authors
Ying Lei
Lei Liu
Si-Heng Du
Zhao-Wen Zong
Lian-Yang Zhang
Qing-Shan Guo
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2018
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-018-1779-8

Other articles of this Issue 1/2018

Journal of Medical Case Reports 1/2018 Go to the issue