Published in:
Open Access
01-10-2014 | Research article
Ultrasound composite scores for the assessment of inflammatory and structural pathologies in Psoriatic Arthritis (PsASon-Score)
Authors:
Anja Ficjan, Rusmir Husic, Judith Gretler, Angelika Lackner, Winfried B Graninger, Marwin Gutierrez, Christina Duftner, Josef Hermann, Christian Dejaco
Published in:
Arthritis Research & Therapy
|
Issue 5/2014
Login to get access
Abstract
Introduction
This study was performed to develop ultrasound composite scores for the assessment of inflammatory and structural lesions in Psoriatic Arthritis (PsA).
Methods
We performed a prospective study on 83 PsA patients undergoing two study visits scheduled 6 months apart. B-mode and Power Doppler (PD) findings were semi-quantitatively scored at 68 joints (evaluating synovia, perisynovial tissue, tendons and bone) and 14 entheses. We constructed bilateral and unilateral (focusing the dominant site) ultrasound composite scores selecting relevant sites by a hierarchical approach. We tested convergent construct validity, reliability and feasibility of inflammatory and structural elements of the scores as well as sensitivity to change for inflammatory items.
Results
The bilateral score (termed PsASon22) included 22 joints (6 metacarpophalangeal joints (MCPs), 4 proximal interphalangeal joints (PIPs) of hands (H-PIPs), 2 metatarsophalangeal joints (MTPs), 4 distal interphalangeal joints (DIPs) of hands (H-DIPs), 2 DIPs of feet (F-DIPs), 4 large joints) and 4 entheses (bilateral assessment of lateral epicondyle and distal patellar tendon). The unilateral score (PsASon13) compromised 13 joints (2 MCPs, 3 H-PIPs, 1 PIP of feet (F-PIP), 2 MTPs, 1 H-DIP and 2 F-DIPs and 2 large joints) and 2 entheses (unilateral lateral epicondyle and distal patellar tendon). Both composite scores revealed a moderate to high sensitivity (bilateral composite score 43% to 100%, unilateral 36% to 100%) to detect inflammatory and structural lesions compared to the 68-joint/14-entheses score. The inflammatory and structural components of the composite scores correlated weakly with clinical markers of disease activity (corrcoeffs 0 to 0.40) and the health assessment questionnaire (HAQ, corrcoeffs 0 to 0.39), respectively. Patients with active disease achieving remission at follow-up yielded greater reductions of ultrasound inflammatory scores than those with stable clinical activity (Cohen’s d effect size ranging from 0 to 0.79). Inter-rater reliability of bi- and unilateral composite scores was moderate to good with ICCs ranging from 0.42 to 0.96 and from 0.36 to 0.71, respectively for inflammatory and structural sub-scores. The PsASon22 and PsASon13 required 16 to 26 and 9 to 13 minutes, respectively to be completed.
Conclusion
Both new PsA ultrasound composite scores (PsASon22 and PsASon13) revealed sufficient convergent construct validity, sensitivity to change, reliability and feasibility.