Skip to main content
Top
Published in: Critical Care 1/2020

Open Access 01-12-2020 | Septicemia | Letter

Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy

Author: Varun Suresh

Published in: Critical Care | Issue 1/2020

Login to get access

Excerpt

I read with interest the research work done by Yang and colleagues [1] on measurement of ultrasonography-guided optic nerve sheath diameter (ONSD) in sepsis-associated encephalopathy (SAE) and its correlation with outcome. I appreciate the authors for successfully demonstrating raised ONSD in SAE patients; however, I have a few methodological concerns with the study. …
Literature
1.
go back to reference Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020;24(1):235.CrossRef Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020;24(1):235.CrossRef
2.
go back to reference Killer HE, Jaggi GP, Miller NR. Papilledema revisited: is its pathophysiology really understood? Clin Exp Ophthalmol. 2009;37(5):444–7.CrossRef Killer HE, Jaggi GP, Miller NR. Papilledema revisited: is its pathophysiology really understood? Clin Exp Ophthalmol. 2009;37(5):444–7.CrossRef
3.
go back to reference Obermeier B, Daneman R, Ransohoff RM. Development, maintenance and disruption of the blood-brain barrier. Nat Med. 2013;19(12):1584–96.CrossRef Obermeier B, Daneman R, Ransohoff RM. Development, maintenance and disruption of the blood-brain barrier. Nat Med. 2013;19(12):1584–96.CrossRef
4.
go back to reference De Bernardo M, Vitiello L, Rosa N. Optic nerve sheath diameter ultrasound: optic nerve growth curve and its application to detect intracranial hypertension in children. Am J Ophthalmol. 2019;208:438.CrossRef De Bernardo M, Vitiello L, Rosa N. Optic nerve sheath diameter ultrasound: optic nerve growth curve and its application to detect intracranial hypertension in children. Am J Ophthalmol. 2019;208:438.CrossRef
5.
go back to reference Bala R, Kumar R, Sharma J. A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter. Indian J Anaesth. 2019;63:537–43.CrossRef Bala R, Kumar R, Sharma J. A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter. Indian J Anaesth. 2019;63:537–43.CrossRef
Metadata
Title
Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy
Author
Varun Suresh
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2020
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-020-03232-7

Other articles of this Issue 1/2020

Critical Care 1/2020 Go to the issue