Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2020

01-12-2020 | Computed Tomography | Research article

Radiological measurement of pelvic fractures using a pelvic deformity measurement software program

Authors: Shuwei Zhang, Gongzi Zhang, Ye Peng, Xiang Wang, Peifu Tang, Lihai Zhang

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2020

Login to get access

Abstract

Background

It is difficult for the surgeon to measure pelvic displacement in the closed reduction operation for unstable pelvic fracture. We therefore developed a pelvic deformity measurement software program based on standardized radiographs. The objectives of the present study were to evaluate the inter-observer reliability of the program for measuring specific fracture types on preoperative pelvic films and to assess the validity of the measurement software program by comparing it with a gold standard.

Methods

Twenty-five patients diagnosed with AO/OTA type B or C pelvic fractures with the unilateral pelvis fractured and dislocated were included in this study. Four separate observers repeatedly determined the translational and rotational patterns and outcomes using the software program and hand measurement, and calculated the displacement using computed tomography (CT) coupled with a three-dimensional (3D) CT model. The validity of the measurement software was calculated by assessing the consistency between the software measurements and the gold standard. Additionally, inter-observer reliability was assessed for the software. The software was also applied in preliminary clinical practice for closed reduction procedures.

Results

The overall inter-observer reliabilities of the software program, CT coupled with 3D reconstruction, and hand measurements were high, with kappa values of 0.956, 0.958, and 0.853, respectively. The software showed validity similar to that of CT coupled with 3D reconstruction (0.939 vs. 0.969), and better than that of hand measurement (0.939 vs. 0.858). A preliminary clinical application demonstrated that the software is effective for guiding closed reduction of pelvic fractures.

Conclusions

Our newly established pelvic deformity measurement program is a reliable and accurate tool for analyzing pelvic displacement patterns and can be used for guidance of closed reduction and planning of the reduction pathway.

Level of evidence

III
Appendix
Available only for authorised users
Literature
1.
go back to reference Buller LT, Best MJ, Quinnan SR. A nationwide analysis of pelvic ring fractures: incidence and trends in treatment, length of stay, and mortality. Geriatr Orthop Surg Rehabil. 2016;7(1):9–17.CrossRef Buller LT, Best MJ, Quinnan SR. A nationwide analysis of pelvic ring fractures: incidence and trends in treatment, length of stay, and mortality. Geriatr Orthop Surg Rehabil. 2016;7(1):9–17.CrossRef
2.
go back to reference Yoshihara H, Yoneoka D. Demographic epidemiology of unstable pelvic fracture in the United States from 2000 to 2009: trends and in-hospital mortality. J Trauma Acute Care Surg. 2014;76(2):380–5.CrossRef Yoshihara H, Yoneoka D. Demographic epidemiology of unstable pelvic fracture in the United States from 2000 to 2009: trends and in-hospital mortality. J Trauma Acute Care Surg. 2014;76(2):380–5.CrossRef
3.
go back to reference Schulman JE, et al. Pelvic ring fractures are an independent risk factor for death after blunt trauma. J Trauma. 2010;68(4):930–934.CrossRef Schulman JE, et al. Pelvic ring fractures are an independent risk factor for death after blunt trauma. J Trauma. 2010;68(4):930–934.CrossRef
4.
go back to reference Miskimins R, et al. Complications of pelvic ring fixation in patients requiring laparotomy. J Surg Res. 2015;199(1):244–8.CrossRef Miskimins R, et al. Complications of pelvic ring fixation in patients requiring laparotomy. J Surg Res. 2015;199(1):244–8.CrossRef
5.
go back to reference Kaempffe FA, Bone LB, Border JR. Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma. 1991;5(4):439–45.CrossRef Kaempffe FA, Bone LB, Border JR. Open reduction and internal fixation of acetabular fractures: heterotopic ossification and other complications of treatment. J Orthop Trauma. 1991;5(4):439–45.CrossRef
6.
go back to reference Reinert CM, et al. A modified extensile exposure for the treatment of complex or malunited acetabular fractures. J Bone Joint Surg. 1988;70(3):329–37.CrossRef Reinert CM, et al. A modified extensile exposure for the treatment of complex or malunited acetabular fractures. J Bone Joint Surg. 1988;70(3):329–37.CrossRef
7.
go back to reference Crowl AC, Kahler DM. Closed reduction and percutaneous fixation of anterior column acetabular fractures. Computer Aided Surg. 2002;7(3):169–78.CrossRef Crowl AC, Kahler DM. Closed reduction and percutaneous fixation of anterior column acetabular fractures. Computer Aided Surg. 2002;7(3):169–78.CrossRef
8.
go back to reference Kellam JF, et al. The unstable pelvic fracture. Operative treatment. Orthop Clin N Am. 1987;18(1):25–41. Kellam JF, et al. The unstable pelvic fracture. Operative treatment. Orthop Clin N Am. 1987;18(1):25–41.
9.
go back to reference Krishnan BH, Sharma Y, Magdum G. A retrospective analysis of percutaneous SI joint fixation in unstable pelvic fractures: our experience in armed forces. Med J Armed Forces India. 2016;72(3):231–5.CrossRef Krishnan BH, Sharma Y, Magdum G. A retrospective analysis of percutaneous SI joint fixation in unstable pelvic fractures: our experience in armed forces. Med J Armed Forces India. 2016;72(3):231–5.CrossRef
10.
go back to reference Nork SE, et al. Percutaneous stabilization of U-shaped sacral fractures using iliosacral screws: technique and early results. J Orthop Trauma. 2001;15(4):238–46.CrossRef Nork SE, et al. Percutaneous stabilization of U-shaped sacral fractures using iliosacral screws: technique and early results. J Orthop Trauma. 2001;15(4):238–46.CrossRef
11.
go back to reference Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Related Res. 1989;242(242):83–97. Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Related Res. 1989;242(242):83–97.
12.
go back to reference Lefaivre KA, Starr AJ, Reinert CM. Reduction of displaced pelvic ring disruptions using a pelvic reduction frame. J Orthop Trauma. 2009;23(4):299–308.CrossRef Lefaivre KA, Starr AJ, Reinert CM. Reduction of displaced pelvic ring disruptions using a pelvic reduction frame. J Orthop Trauma. 2009;23(4):299–308.CrossRef
13.
go back to reference Keating JF, et al. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13(2):107–13.CrossRef Keating JF, et al. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13(2):107–13.CrossRef
14.
go back to reference Papakostidis C, et al. Pelvic ring disruptions: treatment modalities and analysis of outcomes. Int Orthop. 2009;33(2):329–38.CrossRef Papakostidis C, et al. Pelvic ring disruptions: treatment modalities and analysis of outcomes. Int Orthop. 2009;33(2):329–38.CrossRef
15.
go back to reference Lindsay A, Diwan A, Templeman D. Is closed reduction and percutaneous fixation of unstable posterior ring injuries as accurate as open reduction and internal fixation? J Orthop Trauma. 2016;30(1):29–33.CrossRef Lindsay A, Diwan A, Templeman D. Is closed reduction and percutaneous fixation of unstable posterior ring injuries as accurate as open reduction and internal fixation? J Orthop Trauma. 2016;30(1):29–33.CrossRef
16.
go back to reference Mclaren AC, Rorabeck CH, Halpenny J. Long-term pain and disability in relation to residual deformity after displaced pelvic ring fractures. Can J Surg J Can De Chirurgie. 1990;33(6):492–4. Mclaren AC, Rorabeck CH, Halpenny J. Long-term pain and disability in relation to residual deformity after displaced pelvic ring fractures. Can J Surg J Can De Chirurgie. 1990;33(6):492–4.
17.
go back to reference Lindahl J, et al. Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg Brit Vol. 1999;81(6):955–62.CrossRef Lindahl J, et al. Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg Brit Vol. 1999;81(6):955–62.CrossRef
18.
go back to reference Lindahl J, Hirvensalo E. Outcome of operatively treated type-C injuries of the pelvic ring. Acta Orthop Scand. 2005;76(5):667–78.CrossRef Lindahl J, Hirvensalo E. Outcome of operatively treated type-C injuries of the pelvic ring. Acta Orthop Scand. 2005;76(5):667–78.CrossRef
19.
go back to reference Sen RK, Veerappa LA. Outcome analysis of pelvic ring fractures. Indian J Orthop. 2010;44(1):79–83.CrossRef Sen RK, Veerappa LA. Outcome analysis of pelvic ring fractures. Indian J Orthop. 2010;44(1):79–83.CrossRef
20.
go back to reference Dujardin FH, et al. Long-term functional prognosis of posterior injuries in high-energy pelvic disruption. J Orthop Trauma. 1998;12(3):592–3.CrossRef Dujardin FH, et al. Long-term functional prognosis of posterior injuries in high-energy pelvic disruption. J Orthop Trauma. 1998;12(3):592–3.CrossRef
21.
go back to reference Dienstknecht T, et al. The long-term clinical outcome after pelvic ring injuries. Bone Joint J. 2013;95-B(4):548–53.CrossRef Dienstknecht T, et al. The long-term clinical outcome after pelvic ring injuries. Bone Joint J. 2013;95-B(4):548–53.CrossRef
22.
go back to reference Takao M, et al. Clinical application of navigation in the surgical treatment of a pelvic ring injury and acetabular fracture. Adv Exp Med Biol. 2018;1093:289–305.CrossRef Takao M, et al. Clinical application of navigation in the surgical treatment of a pelvic ring injury and acetabular fracture. Adv Exp Med Biol. 2018;1093:289–305.CrossRef
23.
go back to reference Zhang LH, et al. Computer-aided pelvic reduction frame for anatomical closed reduction of unstable pelvic fractures. J Orthop Res. 2015;34(1):81–7.CrossRef Zhang LH, et al. Computer-aided pelvic reduction frame for anatomical closed reduction of unstable pelvic fractures. J Orthop Res. 2015;34(1):81–7.CrossRef
24.
go back to reference Gardner MJ, et al. Displacement after simulated pelvic ring injuries: a cadaveric model of recoil. J Trauma. 2010;68(1):159–65.CrossRef Gardner MJ, et al. Displacement after simulated pelvic ring injuries: a cadaveric model of recoil. J Trauma. 2010;68(1):159–65.CrossRef
25.
go back to reference Zhao JX, et al. A computer aided measurement method for unstable pelvic fractures based on standardized radiographs. BMC Med Imaging. 2015;15(1):1–10.CrossRef Zhao JX, et al. A computer aided measurement method for unstable pelvic fractures based on standardized radiographs. BMC Med Imaging. 2015;15(1):1–10.CrossRef
26.
go back to reference Rockwood CA, et al. Rockwood & Green’s fractures in adults, 7th. Wolters Kluwer Health/ Lippincott, Williams & Wilkins, Philadelphia. 2010:465–466. Rockwood CA, et al. Rockwood & Green’s fractures in adults, 7th. Wolters Kluwer Health/ Lippincott, Williams & Wilkins, Philadelphia. 2010:465–466.
27.
go back to reference Slätis P, Huittinen VM. Double vertical fractures of the pelvis. A report on 163 patients. Am J Clin Nutr. 1972;39(5):722–9. Slätis P, Huittinen VM. Double vertical fractures of the pelvis. A report on 163 patients. Am J Clin Nutr. 1972;39(5):722–9.
28.
go back to reference Semba RT, Yasukawa K, Gustilo RB. Critical analysis of results of 53 Malgaigne fractures of the pelvis. J Trauma. 1983;23(6):535–7.CrossRef Semba RT, Yasukawa K, Gustilo RB. Critical analysis of results of 53 Malgaigne fractures of the pelvis. J Trauma. 1983;23(6):535–7.CrossRef
29.
go back to reference Gabbe BJ, et al. The imaging and classification of severe pelvic ring fractures: experiences from two level 1 trauma centres. Bone Joint J. 2013;95-B(10):1396–401.CrossRef Gabbe BJ, et al. The imaging and classification of severe pelvic ring fractures: experiences from two level 1 trauma centres. Bone Joint J. 2013;95-B(10):1396–401.CrossRef
30.
go back to reference Viegas SF, et al. Measurement of carpal bone geometry by computer analysis of three-dimensional CT images. J Hand Surg. 1993;18(2):341–9.CrossRef Viegas SF, et al. Measurement of carpal bone geometry by computer analysis of three-dimensional CT images. J Hand Surg. 1993;18(2):341–9.CrossRef
31.
go back to reference Nystrom LM, Mckinley TO, Marsh JL. Radiographic measurement of rotational deformity in pelvic fractures: a novel method with validity and reliability testing. J Orthop Trauma. 2015;29(8):365–9.CrossRef Nystrom LM, Mckinley TO, Marsh JL. Radiographic measurement of rotational deformity in pelvic fractures: a novel method with validity and reliability testing. J Orthop Trauma. 2015;29(8):365–9.CrossRef
32.
go back to reference Boulay C, et al. Three-dimensional study of pelvic asymmetry on anatomical specimens and its clinical perspectives. J Anat. 2006;208(1):21–33.CrossRef Boulay C, et al. Three-dimensional study of pelvic asymmetry on anatomical specimens and its clinical perspectives. J Anat. 2006;208(1):21–33.CrossRef
33.
go back to reference Lefaivre KA, et al. Methodology and interpretation of radiographic outcomes in surgically treated pelvic fractures: a systematic review. J Orthop Trauma. 2012;26(8):474–81.CrossRef Lefaivre KA, et al. Methodology and interpretation of radiographic outcomes in surgically treated pelvic fractures: a systematic review. J Orthop Trauma. 2012;26(8):474–81.CrossRef
34.
go back to reference Lefaivre KA, et al. Radiographic displacement in pelvic ring disruption: reliability of 3 previously described measurement techniques. J Orthop Trauma. 2014;28(3):160–6.CrossRef Lefaivre KA, et al. Radiographic displacement in pelvic ring disruption: reliability of 3 previously described measurement techniques. J Orthop Trauma. 2014;28(3):160–6.CrossRef
35.
go back to reference Lefaivre KA, et al. Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. Bone Joint J. 2009;91(9):1201–7. Lefaivre KA, et al. Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. Bone Joint J. 2009;91(9):1201–7.
36.
go back to reference Keshishyan RA, et al. Pelvic polyfractures in children: radiographic diagnosis and treatment. Clin Orthop Related Res. 1995;320(320):28–33. Keshishyan RA, et al. Pelvic polyfractures in children: radiographic diagnosis and treatment. Clin Orthop Related Res. 1995;320(320):28–33.
37.
go back to reference Sagi HC, et al. A comprehensive analysis with minimum 1-year follow-up of vertically unstable transforaminal sacral fractures treated with triangular osteosynthesis. J Orthop Trauma. 2009;23(5):313–9 discussion 319-21.CrossRef Sagi HC, et al. A comprehensive analysis with minimum 1-year follow-up of vertically unstable transforaminal sacral fractures treated with triangular osteosynthesis. J Orthop Trauma. 2009;23(5):313–9 discussion 319-21.CrossRef
Metadata
Title
Radiological measurement of pelvic fractures using a pelvic deformity measurement software program
Authors
Shuwei Zhang
Gongzi Zhang
Ye Peng
Xiang Wang
Peifu Tang
Lihai Zhang
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2020
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-020-1558-2

Other articles of this Issue 1/2020

Journal of Orthopaedic Surgery and Research 1/2020 Go to the issue