Abstract

Background

Intramedullary hip nails may be classified as blades or screws depending on the type of lag screw used. Recently, a combination of lag screw types with a U-clip insertion has also been used. The purpose of this study was to evaluate the clinical and radiological outcomes of these new screw types.

Methods

A total of 185 patients with trochanteric femoral fractures (age ≥ 65 years) who underwent surgery with intramedullary nails were selected. Surgeries with InterTrochanteric/SubTrochanteric (ITST), Proximal Femoral Nail Antirotation (PFNA), and Gamma 3 U-Blade lag screws were performed between January 2011 and June 2016. The AO/OTA classification, presence of a basicervical fracture type on 3D-CT, BMI, BMD, reduction quality, position of the lag screw, TAD (tip apex distance) of the lag screw, sliding distance of the lag screw, varus change (neck shaft angle), radiological union period, fixation failure and functional outcome as determined by walking ability were analyzed.

Results

There were 3/60 (5.0%) cases of fixation failure in the ITST group, all caused by cut-out; 4/57 (7.0%) in the PFNA II group: 3 caused by cut-through and 1 by metal fracture; 1/68 (1.5%) in the Gamma 3 U-Blade lag screw group (P = 0.301). In each group, the sliding distance of the lag screw showed a significant difference (P = 0.017), whereas significant sliding over 10 mm showed no statistically significant results.

Conclusion

There was only one (1.5%) case of fixation failure in the Gamma 3 U-Blade lag screw group. The sliding distance of the U-Blade was found to be in the middle, between the PFNA II (shorter) and ITST (longer) implants. The new rotational control lag screw seems to be comparable to other screw types.
Literature
1.
go back to reference Domingo LJ, Cecilia D, Herrera A, Resines C. Trochanteric fractures treated with a proximal femoral nail. Int Orthop. 2001;25(5):298–301.CrossRef Domingo LJ, Cecilia D, Herrera A, Resines C. Trochanteric fractures treated with a proximal femoral nail. Int Orthop. 2001;25(5):298–301.CrossRef
2.
go back to reference Huang SG, Chen B, Zhang Y, Nie FF, Ju L, Li M, Zhang YH. Comparison of the clinical effectiveness of PFNA, PFLCP, and DHS in treatment of unstable intertrochanteric femoral fracture. Am J Ther. 2017;24(6):e659–66.CrossRef Huang SG, Chen B, Zhang Y, Nie FF, Ju L, Li M, Zhang YH. Comparison of the clinical effectiveness of PFNA, PFLCP, and DHS in treatment of unstable intertrochanteric femoral fracture. Am J Ther. 2017;24(6):e659–66.CrossRef
3.
go back to reference Lang NW, Arthold C, Joestl J, Gormasz A, Boesmueller S, Hajdu S, Sarahrudi K. Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO/OTA 31 A1-3 fractures with gamma 3 nail? Injury. 2016;47(12):2733–8.CrossRef Lang NW, Arthold C, Joestl J, Gormasz A, Boesmueller S, Hajdu S, Sarahrudi K. Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO/OTA 31 A1-3 fractures with gamma 3 nail? Injury. 2016;47(12):2733–8.CrossRef
4.
go back to reference Choi K, Kim Y, Zhou S, Hwang J. Failure of a rotation control Gamma 3 lag screw used to treat a trochanteric fracture. Hip Pelvis. 2018;30(2):129–33.CrossRef Choi K, Kim Y, Zhou S, Hwang J. Failure of a rotation control Gamma 3 lag screw used to treat a trochanteric fracture. Hip Pelvis. 2018;30(2):129–33.CrossRef
5.
go back to reference Fung W, Jonsson A, Buhren V, Bhandari M. Classifying intertrochanteric fractures of the proximal femur: does experience matter? Med Princ Pract. 2007;16(3):198–202.CrossRef Fung W, Jonsson A, Buhren V, Bhandari M. Classifying intertrochanteric fractures of the proximal femur: does experience matter? Med Princ Pract. 2007;16(3):198–202.CrossRef
6.
go back to reference Koval KJ, Skovron ML, Aharonoff GB, Meadows SE, Zuckerman JD. Ambulatory ability after hip fracture. A prospective study in geriatric patients. Clin Orthop Relat Res. 1995;310:150–9. Koval KJ, Skovron ML, Aharonoff GB, Meadows SE, Zuckerman JD. Ambulatory ability after hip fracture. A prospective study in geriatric patients. Clin Orthop Relat Res. 1995;310:150–9.
7.
go back to reference Koval KJ, Aharonoff GB, Rosenberg AD, Bernstein RL, Zuckerman JD. Functional outcome after hip fracture. Effect of general versus regional anesthesia. Clin Orthop Relat Res. 1998;348:37–41. Koval KJ, Aharonoff GB, Rosenberg AD, Bernstein RL, Zuckerman JD. Functional outcome after hip fracture. Effect of general versus regional anesthesia. Clin Orthop Relat Res. 1998;348:37–41.
8.
go back to reference Corrales LA, Morshed S, Bhandari M, Miclau T III. Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am. 2008;90(9):1862.CrossRef Corrales LA, Morshed S, Bhandari M, Miclau T III. Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am. 2008;90(9):1862.CrossRef
9.
go back to reference Kim TY, Lee YB, Chang JD, Lee SS, Yoo JH, Chung KJ, Hwang JH. Torsional malalignment, how much significant in the trochanteric fractures? Injury. 2015;46(11):2196–200.CrossRef Kim TY, Lee YB, Chang JD, Lee SS, Yoo JH, Chung KJ, Hwang JH. Torsional malalignment, how much significant in the trochanteric fractures? Injury. 2015;46(11):2196–200.CrossRef
10.
go back to reference Cho JW, Kent WT, Yoon YC, Kim Y, Kim H, Jha A, Durai SK, Oh JK. Fracture morphology of AO/OTA 31-A trochanteric fractures: a 3D CT study with an emphasis on coronal fragments. Injury. 2017;48(2):277–84.CrossRef Cho JW, Kent WT, Yoon YC, Kim Y, Kim H, Jha A, Durai SK, Oh JK. Fracture morphology of AO/OTA 31-A trochanteric fractures: a 3D CT study with an emphasis on coronal fragments. Injury. 2017;48(2):277–84.CrossRef
11.
go back to reference Shoda E, Kitada S, Sasaki Y, Hirase H, Niikura T, Lee SY, Sakurai A, Oe K, Sasaki T. Proposal of new classification of femoral trochanteric fracture by three-dimensional computed tomography and relationship to usual plain X-ray classification. J Orthop Surg. 2017;25(1):2309499017692700.CrossRef Shoda E, Kitada S, Sasaki Y, Hirase H, Niikura T, Lee SY, Sakurai A, Oe K, Sasaki T. Proposal of new classification of femoral trochanteric fracture by three-dimensional computed tomography and relationship to usual plain X-ray classification. J Orthop Surg. 2017;25(1):2309499017692700.CrossRef
12.
go back to reference Cho YC, Lee PY, Lee CH, Chen CH, Lin YM. Three-dimensional CT improves the reproducibility of stability evaluation for intertrochanteric fractures. Orthop Surg. 2018;10(3):212–7.CrossRef Cho YC, Lee PY, Lee CH, Chen CH, Lin YM. Three-dimensional CT improves the reproducibility of stability evaluation for intertrochanteric fractures. Orthop Surg. 2018;10(3):212–7.CrossRef
13.
go back to reference Huang X, Leung F, Liu M, Chen L, Xu Z, Xiang Z. Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol. 2014;24(8):1461–8.CrossRef Huang X, Leung F, Liu M, Chen L, Xu Z, Xiang Z. Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol. 2014;24(8):1461–8.CrossRef
14.
go back to reference Leung F, Gudushauri P, Yuen G, Lau TW, Fang C, Chow SP. Dynamic hip screw blade fixation for intertrochanteric hip fractures. J Orthop Surg. 2012;20(3):302–6.CrossRef Leung F, Gudushauri P, Yuen G, Lau TW, Fang C, Chow SP. Dynamic hip screw blade fixation for intertrochanteric hip fractures. J Orthop Surg. 2012;20(3):302–6.CrossRef
15.
go back to reference Arirachakaran A, Amphansap T, Thanindratarn P, Piyapittayanun P, Srisawat P, Kongtharvonskul J. Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol. 2017;37:937–52.CrossRef Arirachakaran A, Amphansap T, Thanindratarn P, Piyapittayanun P, Srisawat P, Kongtharvonskul J. Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol. 2017;37:937–52.CrossRef
16.
go back to reference Luo Q, Yuen G, Lau TW, Yeung K, Leung F. A biomechanical study comparing helical blade with screw design for sliding hip fixations of unstable intertrochanteric fractures. Sci World J. 2013;2013:351936. Luo Q, Yuen G, Lau TW, Yeung K, Leung F. A biomechanical study comparing helical blade with screw design for sliding hip fixations of unstable intertrochanteric fractures. Sci World J. 2013;2013:351936.
17.
go back to reference Schwarzkopf R, Takemoto RC, Kummer FJ, Egol KA. Helical blade vs telescoping lag screw for intertrochanteric fracture fixation. Am J Orthop. 2011;40(9):452–6.PubMed Schwarzkopf R, Takemoto RC, Kummer FJ, Egol KA. Helical blade vs telescoping lag screw for intertrochanteric fracture fixation. Am J Orthop. 2011;40(9):452–6.PubMed
18.
go back to reference Stern R, Lubbeke A, Suva D, Miozzari H, Hoffmeyer P. Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures. Int Orthop. 2011;35(12):1855–61.CrossRef Stern R, Lubbeke A, Suva D, Miozzari H, Hoffmeyer P. Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures. Int Orthop. 2011;35(12):1855–61.CrossRef
19.
go back to reference Kancherla R, Sankineni S, Trikha V, Kumar R, Malhotra R. Comment on Stern et al.: Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures. Int Orthop. 2012;36(5):1109–10 (author reply 1111).CrossRef Kancherla R, Sankineni S, Trikha V, Kumar R, Malhotra R. Comment on Stern et al.: Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures. Int Orthop. 2012;36(5):1109–10 (author reply 1111).CrossRef
20.
go back to reference Stern LC, Gorczyca JT, Kates S, Ketz J, Soles G, Humphrey CA. Radiographic review of helical blade versus lag screw fixation for cephalomedullary nailing of low-energy peritrochanteric femur fractures: there is a difference in cutout. J Orthop Trauma. 2017;31(6):305–10.CrossRef Stern LC, Gorczyca JT, Kates S, Ketz J, Soles G, Humphrey CA. Radiographic review of helical blade versus lag screw fixation for cephalomedullary nailing of low-energy peritrochanteric femur fractures: there is a difference in cutout. J Orthop Trauma. 2017;31(6):305–10.CrossRef
21.
go back to reference Ma JX, Kuang MJ, Fan ZR, Xing F, Zhao YL, Zhang LK, Chen HT, Han C, Ma XL. Comparison of clinical outcomes with InterTan vs Gamma nail or PFNA in the treatment of intertrochanteric fractures: a meta-analysis. Sci Rep. 2017;7(1):15962.CrossRef Ma JX, Kuang MJ, Fan ZR, Xing F, Zhao YL, Zhang LK, Chen HT, Han C, Ma XL. Comparison of clinical outcomes with InterTan vs Gamma nail or PFNA in the treatment of intertrochanteric fractures: a meta-analysis. Sci Rep. 2017;7(1):15962.CrossRef
22.
go back to reference Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W. Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury. 2010;41(12):1234–8.CrossRef Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W. Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury. 2010;41(12):1234–8.CrossRef
23.
go back to reference Hong JB, Dan Y, Ouyang L, Liu Y, Xiong LM, Li S, Feng XB, Shao ZW, Yan C, Yang SH, et al. Biomechanical study on different lengths of PFNA fixation for unstable intertrochanteric femoral fractures. J Musculoskelet Neuronal Interact. 2017;17(4):299–302.PubMedPubMedCentral Hong JB, Dan Y, Ouyang L, Liu Y, Xiong LM, Li S, Feng XB, Shao ZW, Yan C, Yang SH, et al. Biomechanical study on different lengths of PFNA fixation for unstable intertrochanteric femoral fractures. J Musculoskelet Neuronal Interact. 2017;17(4):299–302.PubMedPubMedCentral
24.
go back to reference Shin WC, Seo JD, Lee SM, Moon NH, Lee JS, Suh KT. Radiographic outcomes of osteosynthesis using proximal femoral nail antirotation (PFNA) system in intertrochanteric femoral fracture: has PFNA II solved all the problems? Hip Pelvis. 2017;29(2):104–12.CrossRef Shin WC, Seo JD, Lee SM, Moon NH, Lee JS, Suh KT. Radiographic outcomes of osteosynthesis using proximal femoral nail antirotation (PFNA) system in intertrochanteric femoral fracture: has PFNA II solved all the problems? Hip Pelvis. 2017;29(2):104–12.CrossRef
25.
go back to reference Kler J, Godula R, Gazdzik T. Remarks on Gamma nail use in the treatment of trochanteric fracture of the femur. Chir Narzadow Ruchu Ortop Pol. 1998;63(4):329–32.PubMed Kler J, Godula R, Gazdzik T. Remarks on Gamma nail use in the treatment of trochanteric fracture of the femur. Chir Narzadow Ruchu Ortop Pol. 1998;63(4):329–32.PubMed
Metadata
Title
Gamma 3 U-Blade lag screws in patients with trochanteric femur fractures: are rotation control lag screws better than others?
Authors
Jehyun Yoo
Sangmin Kim
Junyoung Choi
Jihyo Hwang
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2019
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-019-1427-z

Other articles of this Issue 1/2019

Journal of Orthopaedic Surgery and Research 1/2019 Go to the issue