Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 7/2017

01-10-2017 | Original Article • HIP - FRACTURES

Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials

Authors: Alisara Arirachakaran, Tanawat Amphansap, Pichaya Thanindratarn, Peerapong Piyapittayanun, Phutsapong Srisawat, Jatupon Kongtharvonskul

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 7/2017

Login to get access

Abstract

The ideal implant for the treatment of an unstable intertrochanteric femoral fracture is still a matter of discussion. The aim of this systematic review is to conduct a network meta-analysis of randomized controlled trials (RCTs) comparing clinical outcomes between dynamic hip screws (DHS), Medoff sliding plating, percutaneous compression plating (PCCP), proximal femoral nails (PFN), Gamma nails and less invasive stabilization system fixation in femoral trochanteric fractures in the elderly. These clinical outcomes consist of total intra-operative time, intra-operative fluoroscopy time, intra-operative blood loss, blood component transfusion, length of hospital stay, postoperative general complications, wound complications, late complications and reoperation rates. This systematic review was conducted using PubMed and Scopus search engines for RCTs comparing clinical outcomes between treatments from inception to February 22, 2015. Thirty-six of 785 studies identified were eligible. Compared to the other implants, PCCP showed the lowest total operative time and units of blood transfusion with an unstandardized mean difference (UMD) of 29.27 min (95% CI 5.24, 53.50) and 0.89 units (95% CI 0.52, 1.25). The lowest incidence of general complications, wound complications and late complications of PCCP was 0.09 (95% CI 0.04, 0.18), 0.01 (95% CI 0.01, 0.04) and 0.05 (95% CI 0.02, 0.11), respectively, when compared to others. The lowest fluoroscopic time was with DHS with an UMD of 0.24 min (95% CI 0.16, 0.32), whereas the lowest blood loss and shortest hospital stay were with PFN with an UMD of 233.61 ml of blood loss (95% CI 153.17, 314.04) and 7.23 days of hospital stay (95% CI 7.15, 7.31) when compared to all other fixation methods. Reoperation rates of all implants had no statistically significant difference. The network meta-analysis suggested that fixation with PCCP significantly shortens operative time and decreases the units of blood transfusion required, while also lowering risks of general complications, wound complications and late complications when compared to fixation. Use of PFN showed the least intra-operative blood loss and shortest hospital stay. Multiple active treatment comparisons indicate that PCCP fixation in trochanteric fractures in the elderly is the treatment of choice in terms of intra-operative outcomes and postoperative complications.
Appendix
Available only for authorised users
Literature
1.
go back to reference Altman DG, Bland JM (2003) Interaction revisited: the difference between two estimates. BMJ (Clin Res ed) 326(7382):219CrossRef Altman DG, Bland JM (2003) Interaction revisited: the difference between two estimates. BMJ (Clin Res ed) 326(7382):219CrossRef
2.
go back to reference Bojan AJ, Beimel C, Speitling A, Taglang G, Ekholm C, Jonsson A (2010) 3066 consecutive Gamma nails. 12 years experience at a single centre. BMC Musculoskelet Disorders 11:133. doi:10.1186/1471-2474-11-133 CrossRef Bojan AJ, Beimel C, Speitling A, Taglang G, Ekholm C, Jonsson A (2010) 3066 consecutive Gamma nails. 12 years experience at a single centre. BMC Musculoskelet Disorders 11:133. doi:10.​1186/​1471-2474-11-133 CrossRef
3.
go back to reference Egger M, Davey Smith G, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ (Clin Res ed) 315(7109):629–634CrossRef Egger M, Davey Smith G, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ (Clin Res ed) 315(7109):629–634CrossRef
4.
go back to reference Ekstrom W, Karlsson-Thur C, Larsson S, Ragnarsson B, Alberts KA (2007) Functional outcome in treatment of unstable trochanteric and subtrochanteric fractures with the proximal femoral nail and the Medoff sliding plate. J Orthop Trauma 21(1):18–25. doi:10.1097/BOT.0b013e31802b41cf CrossRefPubMed Ekstrom W, Karlsson-Thur C, Larsson S, Ragnarsson B, Alberts KA (2007) Functional outcome in treatment of unstable trochanteric and subtrochanteric fractures with the proximal femoral nail and the Medoff sliding plate. J Orthop Trauma 21(1):18–25. doi:10.​1097/​BOT.​0b013e31802b41cf​ CrossRefPubMed
5.
go back to reference Forte ML, Virnig BA, Eberly LE, Swiontkowski MF, Feldman R, Bhandari M, Kane RL (2010) Provider factors associated with intramedullary nail use for intertrochanteric hip fractures. J Bone Joint Surg Am 92(5):1105–1114. doi:10.2106/jbjs.i.00295 CrossRefPubMed Forte ML, Virnig BA, Eberly LE, Swiontkowski MF, Feldman R, Bhandari M, Kane RL (2010) Provider factors associated with intramedullary nail use for intertrochanteric hip fractures. J Bone Joint Surg Am 92(5):1105–1114. doi:10.​2106/​jbjs.​i.​00295 CrossRefPubMed
7.
go back to reference Huang X, Leung F, Liu M, Chen L, Xu Z, Xiang Z (2014) Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol 24(8):1461–1468. doi:10.1007/s00590-014-1429-9 CrossRefPubMed Huang X, Leung F, Liu M, Chen L, Xu Z, Xiang Z (2014) Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials. Eur J Orthop Surg Traumatol 24(8):1461–1468. doi:10.​1007/​s00590-014-1429-9 CrossRefPubMed
8.
go back to reference Huang X, Leung F, Xiang Z, Tan PY, Yang J, Wei DQ, Yu X (2013) Proximal femoral nail versus dynamic hip screw fixation for trochanteric fractures: a meta-analysis of randomized controlled trials. Sci World J 2013:805805. doi:10.1155/2013/805805 Huang X, Leung F, Xiang Z, Tan PY, Yang J, Wei DQ, Yu X (2013) Proximal femoral nail versus dynamic hip screw fixation for trochanteric fractures: a meta-analysis of randomized controlled trials. Sci World J 2013:805805. doi:10.​1155/​2013/​805805
9.
go back to reference Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, Ioannidis JP, Straus S, Thorlund K, Jansen JP, Mulrow C, Catala-Lopez F, Gotzsche PC, Dickersin K, Boutron I, Altman DG, Moher D (2015) The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med 162(11):777–784. doi:10.7326/m14-2385 CrossRefPubMed Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, Ioannidis JP, Straus S, Thorlund K, Jansen JP, Mulrow C, Catala-Lopez F, Gotzsche PC, Dickersin K, Boutron I, Altman DG, Moher D (2015) The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med 162(11):777–784. doi:10.​7326/​m14-2385 CrossRefPubMed
10.
go back to reference Kim WY, Han CH, Park JI, Kim JY (2001) Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop 25(6):360–362CrossRefPubMedPubMedCentral Kim WY, Han CH, Park JI, Kim JY (2001) Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop 25(6):360–362CrossRefPubMedPubMedCentral
12.
go back to reference Kosygan KP, Mohan R, Newman RJ (2002) The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 84(1):19–22CrossRefPubMed Kosygan KP, Mohan R, Newman RJ (2002) The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 84(1):19–22CrossRefPubMed
13.
go back to reference Kristek D, Lovric I, Kristek J, Biljan M, Kristek G, Sakic K (2010) The proximal femoral nail antirotation (PFNA) in the treatment of proximal femoral fractures. Coll Antropol 34(3):937–940PubMed Kristek D, Lovric I, Kristek J, Biljan M, Kristek G, Sakic K (2010) The proximal femoral nail antirotation (PFNA) in the treatment of proximal femoral fractures. Coll Antropol 34(3):937–940PubMed
15.
go back to reference Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J, Luan HX, Yang F, Zheng H, He SJ (2014) Proximal femoral nails antirotation, Gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res 100(8):859–866. doi:10.1016/j.otsr.2014.07.023 CrossRefPubMed Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J, Luan HX, Yang F, Zheng H, He SJ (2014) Proximal femoral nails antirotation, Gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res 100(8):859–866. doi:10.​1016/​j.​otsr.​2014.​07.​023 CrossRefPubMed
16.
go back to reference Matre K, Havelin LI, Gjertsen JE, Vinje T, Espehaug B, Fevang JM (2013) Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register. Injury 44(6):735–742. doi:10.1016/j.injury.2012.12.010 CrossRefPubMed Matre K, Havelin LI, Gjertsen JE, Vinje T, Espehaug B, Fevang JM (2013) Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register. Injury 44(6):735–742. doi:10.​1016/​j.​injury.​2012.​12.​010 CrossRefPubMed
18.
go back to reference Palmer TMPJ, Sutton AJ, Moreno SG (2008) Contour-enhanced funnel plots in meta-analysis. STATA J 8(2):242–254 Palmer TMPJ, Sutton AJ, Moreno SG (2008) Contour-enhanced funnel plots in meta-analysis. STATA J 8(2):242–254
19.
go back to reference Parker MJ, Handoll HH (2010) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Datab Syst Rev 9:CD000093. doi:10.1002/14651858.CD000093.pub5 Parker MJ, Handoll HH (2010) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Datab Syst Rev 9:CD000093. doi:10.​1002/​14651858.​CD000093.​pub5
21.
go back to reference Saarenpaa I, Heikkinen T, Ristiniemi J, Hyvonen P, Leppilahti J, Jalovaara P (2009) Functional comparison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures: a matched-pair study of 268 patients. Int Orthop 33(1):255–260. doi:10.1007/s00264-007-0458-y CrossRefPubMed Saarenpaa I, Heikkinen T, Ristiniemi J, Hyvonen P, Leppilahti J, Jalovaara P (2009) Functional comparison of the dynamic hip screw and the Gamma locking nail in trochanteric hip fractures: a matched-pair study of 268 patients. Int Orthop 33(1):255–260. doi:10.​1007/​s00264-007-0458-y CrossRefPubMed
22.
23.
go back to reference Song F, Altman DG, Glenny AM, Deeks JJ (2003) Validity of indirect comparison for estimating efficacy of competing interventions: empirical evidence from published meta-analyses. BMJ (Clin Res ed) 326(7387):472. doi:10.1136/bmj.326.7387.472 CrossRef Song F, Altman DG, Glenny AM, Deeks JJ (2003) Validity of indirect comparison for estimating efficacy of competing interventions: empirical evidence from published meta-analyses. BMJ (Clin Res ed) 326(7387):472. doi:10.​1136/​bmj.​326.​7387.​472 CrossRef
25.
go back to reference StataCorp. (2014) Stata 14 base reference manual. Stata Press, College Station StataCorp. (2014) Stata 14 base reference manual. Stata Press, College Station
26.
go back to reference Tao R, Lu Y, Xu H, Zhou ZY, Wang YH, Liu F (2013) Internal fixation of intertrochanteric hip fractures: a clinical comparison of two implant designs. Sci World J 2013:834825. doi:10.1155/2013/834825 CrossRef Tao R, Lu Y, Xu H, Zhou ZY, Wang YH, Liu F (2013) Internal fixation of intertrochanteric hip fractures: a clinical comparison of two implant designs. Sci World J 2013:834825. doi:10.​1155/​2013/​834825 CrossRef
27.
go back to reference Watson JT, Moed BR, Cramer KE, Karges DE (1998) Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures. Clin Orthop Relat Res 348:79–86CrossRef Watson JT, Moed BR, Cramer KE, Karges DE (1998) Comparison of the compression hip screw with the Medoff sliding plate for intertrochanteric fractures. Clin Orthop Relat Res 348:79–86CrossRef
30.
go back to reference Zhang L, Shen J, Yu S, Huang Q, Xie Z (2014) Percutaneous compression plate versus dynamic hip screw for treatment of intertrochanteric Hip fractures: a meta-analyse of five randomized controlled trials. Sci World J 2014:512512. doi:10.1155/2014/512512 Zhang L, Shen J, Yu S, Huang Q, Xie Z (2014) Percutaneous compression plate versus dynamic hip screw for treatment of intertrochanteric Hip fractures: a meta-analyse of five randomized controlled trials. Sci World J 2014:512512. doi:10.​1155/​2014/​512512
Metadata
Title
Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials
Authors
Alisara Arirachakaran
Tanawat Amphansap
Pichaya Thanindratarn
Peerapong Piyapittayanun
Phutsapong Srisawat
Jatupon Kongtharvonskul
Publication date
01-10-2017
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 7/2017
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-017-1964-2

Other articles of this Issue 7/2017

European Journal of Orthopaedic Surgery & Traumatology 7/2017 Go to the issue