Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2019

Open Access 01-12-2019 | Ultrasound | Research article

Is it difficult to obtain inter-observer agreement in the measurement of the beta angle in ultrasound evaluation of the paediatric hip?

Authors: Ozgun Karakus, Ozgur Karaman, Ahmet Sinan Sari, Mehmet Mufit Orak, Hasan Hilmi Muratli

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2019

Login to get access

Abstract

Introduction

The aim of this study was to determine the differences and consistencies in the morphological and angular interpretations of standard USG images. Therefore, it was aimed to show the correlations of orthopaedic doctors with different periods of experience in hip ultrasound measurements taken with the Graf method.

Materials and methods

The study included 210 infants randomly selected from those who presented at our hospital for DDH screening. A total of 6 ultrasound images were taken for each hip. These images were evaluated by  two paediatric orthopaedic professors, two orthopaedic specialists and two orthopaedic residents. The correlations of these measurements between all the doctors were evaluated statistically.

Results

In beta angle evaluation, agreement between all the evaluators was at the level of 0.054. No agreement was seen between the two residents or between the two specialists (p = 0.003, p = 0.998, p = 0.998, respectively). Agreement between the two professors was determined at the level of 0.508 (p < 0.001). Agreement was determined at the level of 0.066 between the specialists and the residents. No agreement was observed between the specialists and the professors or between the professors and the residents (p = 0.014, p = 0.098, p = 0.737, respectively).

Conclusions

It can be concluded that greater emphasis on the beta angle, the cartilage labrum, and more detailed explanations of this subject in the resident training program will achieve standardisation on this subject, and this is in direct proportion to clinical experience.

Level of evidence

IV
Literature
1.
go back to reference Wientroub S, Grill F. Ultrasonography in developmental dysplasia of the hip. J Bone Joint Surg Am. 2000;82-A(7):1004–18.CrossRef Wientroub S, Grill F. Ultrasonography in developmental dysplasia of the hip. J Bone Joint Surg Am. 2000;82-A(7):1004–18.CrossRef
2.
go back to reference Lowry CA, Donoghue VB, Murphy JF. Auditing hip ultrasound screening of infants at increased risk of developmental dysplasia of the hip. Arch Dis Child. 2005;90(6):579–81.CrossRef Lowry CA, Donoghue VB, Murphy JF. Auditing hip ultrasound screening of infants at increased risk of developmental dysplasia of the hip. Arch Dis Child. 2005;90(6):579–81.CrossRef
3.
go back to reference Mahan ST, Katz JN, Kim YJ. To screen or not to screen? A decision analysis of the utility of screening for developmental dysplasia of the hip. J Bone Joint Surg Am. 2009;91(7):1705–19.CrossRef Mahan ST, Katz JN, Kim YJ. To screen or not to screen? A decision analysis of the utility of screening for developmental dysplasia of the hip. J Bone Joint Surg Am. 2009;91(7):1705–19.CrossRef
4.
go back to reference Keller MS, Nijs EL. The role of radiographs and US in developmental dysplasia of the hip: how good are they? Pediatr Radiol. 2009;39(Suppl (2)):S211–5.CrossRef Keller MS, Nijs EL. The role of radiographs and US in developmental dysplasia of the hip: how good are they? Pediatr Radiol. 2009;39(Suppl (2)):S211–5.CrossRef
5.
go back to reference Castelein RM, Sauter AJ. Ultrasound screening for congenital dysplasia of the hip in newborns: its values. J Pediatr Orthop. 1988;8(6):666–70.CrossRef Castelein RM, Sauter AJ. Ultrasound screening for congenital dysplasia of the hip in newborns: its values. J Pediatr Orthop. 1988;8(6):666–70.CrossRef
6.
go back to reference Exner GU. Ultrasound screening for hip dysplasia in neonates. J Pediatr Orthop. 1988;8(6):656–60.CrossRef Exner GU. Ultrasound screening for hip dysplasia in neonates. J Pediatr Orthop. 1988;8(6):656–60.CrossRef
7.
go back to reference Grissom LE, Harcke HT, Kumar SJ, et al. Ultrasound evaluation of hip position in the Pavlik harness. J Ultrasound Med. 1988;7(1):1–6.CrossRef Grissom LE, Harcke HT, Kumar SJ, et al. Ultrasound evaluation of hip position in the Pavlik harness. J Ultrasound Med. 1988;7(1):1–6.CrossRef
8.
go back to reference Szöke N, Kühl L, Heinrichs J. Ultrasound examination in the diagnosis of congenital hip dysplasia of newborns. J Pediatr Orthop. 1988;8(1):12–6.CrossRef Szöke N, Kühl L, Heinrichs J. Ultrasound examination in the diagnosis of congenital hip dysplasia of newborns. J Pediatr Orthop. 1988;8(1):12–6.CrossRef
9.
go back to reference Tonnis D, Storch K, Ulbrich H. Results of newborn screening for CDH with and without sonography and correlation of risk factors. J Pediatr Orthop. 1990;10(2):145–52.CrossRef Tonnis D, Storch K, Ulbrich H. Results of newborn screening for CDH with and without sonography and correlation of risk factors. J Pediatr Orthop. 1990;10(2):145–52.CrossRef
10.
go back to reference Bon RA, Exner GU. Early diagnosis of hip dysplasia: arguments for a general ultrasonographic screening. Schweiz Rundsch Med Prax. 1992;81(16):519–23.PubMed Bon RA, Exner GU. Early diagnosis of hip dysplasia: arguments for a general ultrasonographic screening. Schweiz Rundsch Med Prax. 1992;81(16):519–23.PubMed
11.
go back to reference Graf R. Kursus der Hüftsonographie beim Säugling. Stuttgart: Gustav Fischer Verlag; 1995. Graf R. Kursus der Hüftsonographie beim Säugling. Stuttgart: Gustav Fischer Verlag; 1995.
12.
go back to reference Shorter D, Hong T, Osborn DA. Cochrane review: screening programmes for developmental dysplasia of the hip in newborn infants. Evid Based Child Health. 2013;8(1):11–54.CrossRef Shorter D, Hong T, Osborn DA. Cochrane review: screening programmes for developmental dysplasia of the hip in newborn infants. Evid Based Child Health. 2013;8(1):11–54.CrossRef
13.
go back to reference Portinaro NM, Pelillo F, Cerutti P. The role of ultrasonography in the diagnosis of developmental dysplasia of the hip. J Pediatr Orthop. 2007;27(2):247–50.CrossRef Portinaro NM, Pelillo F, Cerutti P. The role of ultrasonography in the diagnosis of developmental dysplasia of the hip. J Pediatr Orthop. 2007;27(2):247–50.CrossRef
14.
go back to reference Graf R. The ultrasound examination of the hip. In: Tonnis D, editor. Congenital dysplasia and dislocation of the hip. Berlin: Springer; 1987. p. 172–229.CrossRef Graf R. The ultrasound examination of the hip. In: Tonnis D, editor. Congenital dysplasia and dislocation of the hip. Berlin: Springer; 1987. p. 172–229.CrossRef
15.
go back to reference Bar-On E, Meyer S, Harari G, et al. Ultrasonography of the hip in developmental hip dysplasia. J Bone Joint Surg (Br). 1998;80(2):321–4.CrossRef Bar-On E, Meyer S, Harari G, et al. Ultrasonography of the hip in developmental hip dysplasia. J Bone Joint Surg (Br). 1998;80(2):321–4.CrossRef
16.
go back to reference Graf R. Hip sonography: diagnosis and management of infant hip dysplasia. Berlin: Springer; 2006. Graf R. Hip sonography: diagnosis and management of infant hip dysplasia. Berlin: Springer; 2006.
17.
go back to reference Graf R. Classification of hip joint dysplasia by means of sonography. Arch Orthop Trauma Surg. 1984;102:248–55.CrossRef Graf R. Classification of hip joint dysplasia by means of sonography. Arch Orthop Trauma Surg. 1984;102:248–55.CrossRef
18.
go back to reference Peled E, Eidelman M, Katzman A, et al. Neonatal incidence of hip dysplasia: ten years of experience. Clin Orthop Relat Res. 2008;466(4):771–5.CrossRef Peled E, Eidelman M, Katzman A, et al. Neonatal incidence of hip dysplasia: ten years of experience. Clin Orthop Relat Res. 2008;466(4):771–5.CrossRef
19.
go back to reference Falliner A, Schwinzer D, Hahne HJ, et al. Comparing ultrasound measurements of neonatal hips using the methods of Graf and Tejersen. J Bone Joint Surg Br. 2006;88(1):104–6.CrossRef Falliner A, Schwinzer D, Hahne HJ, et al. Comparing ultrasound measurements of neonatal hips using the methods of Graf and Tejersen. J Bone Joint Surg Br. 2006;88(1):104–6.CrossRef
20.
go back to reference Graf R. The diagnosis of congenital hip-joint dislocation by the ultrasonic Combound treatment. Arch Orthop Trauma Surg. 1980;97(2):117–33.CrossRef Graf R. The diagnosis of congenital hip-joint dislocation by the ultrasonic Combound treatment. Arch Orthop Trauma Surg. 1980;97(2):117–33.CrossRef
21.
go back to reference Kamath S, Mehdi A, Wilson N, et al. The lack of evidence of the effect of selective ultrasound screening on the incidence of late developmental dysplasia of the hip in the Greater Glasgow Region. J Pediatr Orthop B. 2007;16(3):189–91.CrossRef Kamath S, Mehdi A, Wilson N, et al. The lack of evidence of the effect of selective ultrasound screening on the incidence of late developmental dysplasia of the hip in the Greater Glasgow Region. J Pediatr Orthop B. 2007;16(3):189–91.CrossRef
22.
go back to reference Laborie LB, Engesæter IØ, Lehmann TG, et al. Screening strategies for hip dysplasia: long-term outcome of a randomized controlled trial. Pediatrics. 2013;132(3):492–501.CrossRef Laborie LB, Engesæter IØ, Lehmann TG, et al. Screening strategies for hip dysplasia: long-term outcome of a randomized controlled trial. Pediatrics. 2013;132(3):492–501.CrossRef
23.
go back to reference Roovers EA, Boere-Boonekamp MM, Castelein RM, et al. Effectiveness of ultrasound screening for developmental dysplasia of the hip. Arch Dis Child Fetal Neonatal Ed. 2005;90(1):F25–30.CrossRef Roovers EA, Boere-Boonekamp MM, Castelein RM, et al. Effectiveness of ultrasound screening for developmental dysplasia of the hip. Arch Dis Child Fetal Neonatal Ed. 2005;90(1):F25–30.CrossRef
24.
go back to reference Simon EA, Saur F, Buerge M, et al. Inter-observer agreement of ultrasonographic measurement of alpha and beta angles and the final type classification based on the Graf method. Swiss Med Wkly. 2004;134(45–46):671–7.PubMed Simon EA, Saur F, Buerge M, et al. Inter-observer agreement of ultrasonographic measurement of alpha and beta angles and the final type classification based on the Graf method. Swiss Med Wkly. 2004;134(45–46):671–7.PubMed
25.
go back to reference Roovers EA, Boere-Boonekamp MM, Geertsma TS, et al. Ultrasonographic screening for developmental dysplasia of the hip in infants. Reproducibility of assessments made by radiographers. J Bone Joint Surg Br. 2003;85(5):726–30.CrossRef Roovers EA, Boere-Boonekamp MM, Geertsma TS, et al. Ultrasonographic screening for developmental dysplasia of the hip in infants. Reproducibility of assessments made by radiographers. J Bone Joint Surg Br. 2003;85(5):726–30.CrossRef
Metadata
Title
Is it difficult to obtain inter-observer agreement in the measurement of the beta angle in ultrasound evaluation of the paediatric hip?
Authors
Ozgun Karakus
Ozgur Karaman
Ahmet Sinan Sari
Mehmet Mufit Orak
Hasan Hilmi Muratli
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2019
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-019-1263-1

Other articles of this Issue 1/2019

Journal of Orthopaedic Surgery and Research 1/2019 Go to the issue