Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2018

Open Access 01-12-2018 | Research article

Comparing case-control study for treatment of proximal tibia fractures with a complete metaphyseal component in two centers with different distinct strategies: fixation with Ilizarov frame or locking plates

Authors: Haakon Berven, Michael Brix, Kaywan Izadpanah, Eva Johanna Kubosch, Hagen Schmal

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2018

Login to get access

Abstract

Background

The purpose of this study was to compare two methods of stabilization for proximal tibia fractures (AO 41) with a complete metaphyseal component, external fixation with the Ilizarov wire frame, and internal fixation with locking plates.

Methods

Patients from two level 1 trauma centers treated between 2009 and 2015 were included in a retrospective comparing cohort study. The first center stabilized the non-pathological, proximal tibia fractures exclusively with external fixation and the second with internal plating. Combined clinically and radiologically evaluated, bone healing was the primary outcome. The secondary outcomes included complications, range of motion (ROM) and axial alignment of the knee, the reoperation rate within 6 months, heterotopic ossifications (HTO), and signs of posttraumatic osteoarthritis (PTOA). A logistic regression analysis corrected for uneven distributed parameters.

Results

The 62 patients treated with Ilizarov frame and the 68 patients treated with plate fixation were comparable regarding epidemiological parameters, injury characteristics, and comorbidity except for injury severity score (ISS) and smoking behavior. The time of healing was shorter in the group undergoing plate fixation (p = 0.041); however, the incidence of non-unions was equal. Furthermore, there was no difference regarding the rate of deep infections, thrombosis, alignment, reoperations, PTOA, and ROM. Heterotopic ossifications were more prevalent following plate fixation (13.2 vs 1.6%, p = .013). External fixation was associated with a higher rate of superficial infections (40.4 vs 2.9%, p = .000). The initial displacement, the incidence of deep infections, and the classification significantly influenced the incidence of non-unions in both groups (p < 0.02).

Conclusions

Fixation of proximal tibia fractures with plates resulted in a slightly shorter healing time compared to Ilizarov frame stabilization. Furthermore, the complication profiles differ with more heterotopic ossifications and less superficial infections following internal plating.

Trial registration

DRKS, DRKS00013275, Registered 11/2/2017, Retrospectively registered.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bono CM, Levine RG, Rao JP, Behrens FF. Nonarticular proximal tibia fractures: treatment options and decision making. J Am Acad Orthop Surg. 2001;9(3):176–86.CrossRefPubMed Bono CM, Levine RG, Rao JP, Behrens FF. Nonarticular proximal tibia fractures: treatment options and decision making. J Am Acad Orthop Surg. 2001;9(3):176–86.CrossRefPubMed
2.
go back to reference Naik MA, Arora G, Tripathy SK, Sujir P, Rao SK. Clinical and radiological outcome of percutaneous plating in extra-articular proximal tibia fractures: a prospective study. Injury. 2013;44(8):1081–6.CrossRefPubMed Naik MA, Arora G, Tripathy SK, Sujir P, Rao SK. Clinical and radiological outcome of percutaneous plating in extra-articular proximal tibia fractures: a prospective study. Injury. 2013;44(8):1081–6.CrossRefPubMed
3.
go back to reference Kokkalis ZT, Iliopoulos ID, Pantazis C, Panagiotopoulos E. What’s new in the management of complex tibial plateau fractures? Injury. 2016;47(6):1162–9.CrossRefPubMed Kokkalis ZT, Iliopoulos ID, Pantazis C, Panagiotopoulos E. What’s new in the management of complex tibial plateau fractures? Injury. 2016;47(6):1162–9.CrossRefPubMed
4.
go back to reference Schmal H, Strohm PC, Jaeger M, Sudkamp NP. Flexible fixation and fracture healing: do locked plating ‘internal fixators’ resemble external fixators? J Orthop Trauma. 2011;25(Suppl 1):S15–20.CrossRefPubMed Schmal H, Strohm PC, Jaeger M, Sudkamp NP. Flexible fixation and fracture healing: do locked plating ‘internal fixators’ resemble external fixators? J Orthop Trauma. 2011;25(Suppl 1):S15–20.CrossRefPubMed
5.
go back to reference El-Sayed MMH, Khanfour AA. Management of high-energy bicondylar tibial plateau fractures by minimal internal fixation and the ilizarov frame: the knee function. Eur Orthop Traumatol. 2014;5:109–14.CrossRef El-Sayed MMH, Khanfour AA. Management of high-energy bicondylar tibial plateau fractures by minimal internal fixation and the ilizarov frame: the knee function. Eur Orthop Traumatol. 2014;5:109–14.CrossRef
6.
go back to reference Spagnolo R, Pace F. Management of the Schatzker VI fractures with lateral locked screw plating. Musculoskelet Surg. 2012;96(2):75–80.CrossRefPubMed Spagnolo R, Pace F. Management of the Schatzker VI fractures with lateral locked screw plating. Musculoskelet Surg. 2012;96(2):75–80.CrossRefPubMed
7.
go back to reference Yu L, Fenglin Z. High-energy tibial plateau fractures: external fixation versus plate fixation. Eur J Orthop Surg Traumatol. 2015;25(3):411–23.CrossRefPubMed Yu L, Fenglin Z. High-energy tibial plateau fractures: external fixation versus plate fixation. Eur J Orthop Surg Traumatol. 2015;25(3):411–23.CrossRefPubMed
8.
go back to reference Hauschild O, Konrad G, Audige L, et al. Operative versus non-operative treatment for two-part surgical neck fractures of the proximal humerus. Arch Orthop Trauma Surg. 2013;133(10):1385–93.CrossRefPubMed Hauschild O, Konrad G, Audige L, et al. Operative versus non-operative treatment for two-part surgical neck fractures of the proximal humerus. Arch Orthop Trauma Surg. 2013;133(10):1385–93.CrossRefPubMed
9.
go back to reference Müller ME, Nazarian S, Koch P, Schatzker J. The comprehensive classification of fractures of long bones. Springer-Verlag Berlin Heidelberg, Springer-Verlag Berlin Heidelberg. 1990. p. 148–91. Müller ME, Nazarian S, Koch P, Schatzker J. The comprehensive classification of fractures of long bones. Springer-Verlag Berlin Heidelberg, Springer-Verlag Berlin Heidelberg. 1990. p. 148–91.
10.
go back to reference Baker SP, O'Neill B, Haddon W Jr, Long WB. The injury severity score: a method for describing patients with multiple injuries and evaluating emergency care. J Trauma. 1974;14(3):187–96.CrossRefPubMed Baker SP, O'Neill B, Haddon W Jr, Long WB. The injury severity score: a method for describing patients with multiple injuries and evaluating emergency care. J Trauma. 1974;14(3):187–96.CrossRefPubMed
11.
go back to reference Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma. 2004;18(8):528–35.CrossRefPubMed Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma. 2004;18(8):528–35.CrossRefPubMed
13.
go back to reference Krupp RJ, Malkani AL, Roberts CS, Seligson D, Crawford CH 3rd, Smith L. Treatment of bicondylar tibia plateau fractures using locked plating versus external fixation. Orthopedics. 2009;32(8) Krupp RJ, Malkani AL, Roberts CS, Seligson D, Crawford CH 3rd, Smith L. Treatment of bicondylar tibia plateau fractures using locked plating versus external fixation. Orthopedics. 2009;32(8)
14.
go back to reference Ahearn N, Oppy A, Halliday R, et al. The outcome following fixation of bicondylar tibial plateau fractures. Bone Joint J. 2014;96-B(7):956–62.CrossRefPubMed Ahearn N, Oppy A, Halliday R, et al. The outcome following fixation of bicondylar tibial plateau fractures. Bone Joint J. 2014;96-B(7):956–62.CrossRefPubMed
15.
go back to reference Lindvall E, Sanders R, Dipasquale T, Herscovici D, Haidukewych G, Sagi C. Intramedullary nailing versus percutaneous locked plating of extra-articular proximal tibial fractures: comparison of 56 cases. J Orthop Trauma. 2009;23(7):485–92.CrossRefPubMed Lindvall E, Sanders R, Dipasquale T, Herscovici D, Haidukewych G, Sagi C. Intramedullary nailing versus percutaneous locked plating of extra-articular proximal tibial fractures: comparison of 56 cases. J Orthop Trauma. 2009;23(7):485–92.CrossRefPubMed
16.
go back to reference Bhandari M, Audige L, Ellis T, Hanson B, Evidence-Based Orthopaedic Trauma Working G. Operative treatment of extra-articular proximal tibial fractures. J Orthop Trauma. 2003;17(8):591–5.CrossRefPubMed Bhandari M, Audige L, Ellis T, Hanson B, Evidence-Based Orthopaedic Trauma Working G. Operative treatment of extra-articular proximal tibial fractures. J Orthop Trauma. 2003;17(8):591–5.CrossRefPubMed
17.
go back to reference Chan C, Keating J. Comparison of outcomes of operatively treated bicondylar tibial plateau fractures by external fixation and internal fixation. Malays Orthop J. 2012;6(1):7–12.CrossRefPubMedPubMedCentral Chan C, Keating J. Comparison of outcomes of operatively treated bicondylar tibial plateau fractures by external fixation and internal fixation. Malays Orthop J. 2012;6(1):7–12.CrossRefPubMedPubMedCentral
18.
go back to reference Meena RC, Meena UK, Gupta GL, Gahlot N, Gaba S. Intramedullary nailing versus proximal plating in the management of closed extra-articular proximal tibial fracture: a randomized controlled trial. J Orthop Traumatol. 2015;16(3):203–8.CrossRefPubMedPubMedCentral Meena RC, Meena UK, Gupta GL, Gahlot N, Gaba S. Intramedullary nailing versus proximal plating in the management of closed extra-articular proximal tibial fracture: a randomized controlled trial. J Orthop Traumatol. 2015;16(3):203–8.CrossRefPubMedPubMedCentral
19.
go back to reference Metcalfe D, Hickson CJ, McKee L, Griffin XL. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis. J Orthop Traumatol. 2015;16(4):275–85.CrossRefPubMedPubMedCentral Metcalfe D, Hickson CJ, McKee L, Griffin XL. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis. J Orthop Traumatol. 2015;16(4):275–85.CrossRefPubMedPubMedCentral
20.
go back to reference Keightley AJ, Nawaz SZ, Jacob JT, Unnithan A, Elliott DS, Khaleel A. Ilizarov management of Schatzker IV to VI fractures of the tibial plateau: 105 fractures at a mean follow-up of 7.8 years. Bone Joint J. 2015;97-B(12):1693–7.CrossRefPubMed Keightley AJ, Nawaz SZ, Jacob JT, Unnithan A, Elliott DS, Khaleel A. Ilizarov management of Schatzker IV to VI fractures of the tibial plateau: 105 fractures at a mean follow-up of 7.8 years. Bone Joint J. 2015;97-B(12):1693–7.CrossRefPubMed
21.
go back to reference Canadian Orthopaedic Trauma S. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial. J Bone Joint Surg Am. 2006;88(12):2613–23.CrossRef Canadian Orthopaedic Trauma S. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial. J Bone Joint Surg Am. 2006;88(12):2613–23.CrossRef
22.
go back to reference Conserva V, Vicenti G, Allegretti G, et al. Retrospective review of tibial plateau fractures treated by two methods without staging. Injury. 2015;46(10):1951–6.CrossRefPubMed Conserva V, Vicenti G, Allegretti G, et al. Retrospective review of tibial plateau fractures treated by two methods without staging. Injury. 2015;46(10):1951–6.CrossRefPubMed
23.
go back to reference Jiang R, Luo CF, Wang MC, Yang TY, Zeng BF. A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures. Knee. 2008;15(2):139–43.CrossRefPubMed Jiang R, Luo CF, Wang MC, Yang TY, Zeng BF. A comparative study of Less Invasive Stabilization System (LISS) fixation and two-incision double plating for the treatment of bicondylar tibial plateau fractures. Knee. 2008;15(2):139–43.CrossRefPubMed
24.
go back to reference Jansen H, Frey SP, Doht S, Fehske K, Meffert RH. Medium-term results after complex intra-articular fractures of the tibial plateau. J Orthop Sci. 2013;18(4):569–77.CrossRefPubMed Jansen H, Frey SP, Doht S, Fehske K, Meffert RH. Medium-term results after complex intra-articular fractures of the tibial plateau. J Orthop Sci. 2013;18(4):569–77.CrossRefPubMed
25.
go back to reference van Dreumel RL, van Wunnik BP, Janssen L, Simons PC, Janzing HM. Mid- to long-term functional outcome after open reduction and internal fixation of tibial plateau fractures. Injury. 2015;46(8):1608–12.CrossRefPubMed van Dreumel RL, van Wunnik BP, Janssen L, Simons PC, Janzing HM. Mid- to long-term functional outcome after open reduction and internal fixation of tibial plateau fractures. Injury. 2015;46(8):1608–12.CrossRefPubMed
26.
go back to reference Andersen T, Christensen FB, Laursen M, Høy K, Hansen ES, Bunger C. Smoking as a predictor of negative outcome in lumbar spinal fusion. Spine. 2001;26(23):2623–8.CrossRefPubMed Andersen T, Christensen FB, Laursen M, Høy K, Hansen ES, Bunger C. Smoking as a predictor of negative outcome in lumbar spinal fusion. Spine. 2001;26(23):2623–8.CrossRefPubMed
27.
go back to reference Kubosch EJ, Bernstein A, Wolf L, Fretwurst T, Nelson K, Schmal H. Clinical trial and in-vitro study comparing the efficacy of treating bony lesions with allografts versus synthetic or highly-processed xenogeneic bone grafts. BMC Musculoskelet Disord. 2016;17:77.CrossRefPubMedPubMedCentral Kubosch EJ, Bernstein A, Wolf L, Fretwurst T, Nelson K, Schmal H. Clinical trial and in-vitro study comparing the efficacy of treating bony lesions with allografts versus synthetic or highly-processed xenogeneic bone grafts. BMC Musculoskelet Disord. 2016;17:77.CrossRefPubMedPubMedCentral
28.
go back to reference Turan A, Mascha EJ, Roberman D, et al. Smoking and perioperative outcomes. Anesthesiology. 2011;114(4):837–46.CrossRefPubMed Turan A, Mascha EJ, Roberman D, et al. Smoking and perioperative outcomes. Anesthesiology. 2011;114(4):837–46.CrossRefPubMed
Metadata
Title
Comparing case-control study for treatment of proximal tibia fractures with a complete metaphyseal component in two centers with different distinct strategies: fixation with Ilizarov frame or locking plates
Authors
Haakon Berven
Michael Brix
Kaywan Izadpanah
Eva Johanna Kubosch
Hagen Schmal
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2018
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-018-0792-3