Skip to main content
Top
Published in: World Journal of Emergency Surgery 1/2016

Open Access 01-12-2016 | Methodology

On table POCUS assessment for the IVC following abdominal packing: how I do it

Author: Fikri M. Abu-Zidan

Published in: World Journal of Emergency Surgery | Issue 1/2016

Login to get access

Abstract

Background

Some surgeons may lack proper experience in abdominal packing. Overpacking may directly compress the inferior vena cava (IVC). This reduces the venous return and possibly causes hypotension. Here, a new on table Point-of-Care Ultrasound application that has been recently used to assess the effect of abdominal packing on the IVC diameter is described. Following abdominal packing, a small print convex array probe with low frequency (2–5 MHz) is used to visualize the IVC. Using the B mode, the IVC can be directly evaluated through a hepatic window between the ribs. The ultrasound beam should be vertical to the IVC longitudinal section at its midpoint. The abdominal towels will be in front of the IVC. This will enable us to judge whether there was overpacking on the IVC.

Results

Our method demonstrates that overpacking does not compress the IVC in a patient whose blood pressure has improved. The IVC diameter progressively increases on table and in the ICU with active resuscitation implying that bleeding stopped and the resuscitation was successful. Furthermore, presence of intra-peritoneal fluid can be excluded.

Conclusions

This new application of ultrasound evaluation of IVC patency after abdominal packing is simple, practical, easily reproducible, and can guide a less experienced surgeon in determining if overpacking of the abdomen is the cause of hypotension. Ultrasound findings should be correlated with the clinical picture to be useful.
Literature
1.
go back to reference Bashir MM, Abu-Zidan FM. Damage control surgery for abdominal trauma. Eur J Surg. 2003;168 Suppl 588:8–13. Bashir MM, Abu-Zidan FM. Damage control surgery for abdominal trauma. Eur J Surg. 2003;168 Suppl 588:8–13.
2.
5.
go back to reference Perera P, Mailhot T, Riley D, Mandavia D. The RUSH exam: rapid ultrasound in SHock in the evaluation of the critically ill. Emerg Med Clin North Am. 2010;28:29–56.CrossRefPubMed Perera P, Mailhot T, Riley D, Mandavia D. The RUSH exam: rapid ultrasound in SHock in the evaluation of the critically ill. Emerg Med Clin North Am. 2010;28:29–56.CrossRefPubMed
6.
go back to reference Dittrich K, Abu-Zidan FM. Role of ultrasound in mass-casualty situations. Int J Disaster Med. 2004;2:18–23.CrossRef Dittrich K, Abu-Zidan FM. Role of ultrasound in mass-casualty situations. Int J Disaster Med. 2004;2:18–23.CrossRef
8.
go back to reference Seif D, Mailhot T, Perera P, Mandavia D. Caval sonography in shock: a noninvasive method for evaluating intravascular volume in critically ill patients. J Ultrasound Med. 2012;31:1885–90.PubMed Seif D, Mailhot T, Perera P, Mandavia D. Caval sonography in shock: a noninvasive method for evaluating intravascular volume in critically ill patients. J Ultrasound Med. 2012;31:1885–90.PubMed
9.
go back to reference Yanagawa Y, Sakamoto T, Okada Y. Hypovolemic shock evaluated by sonographic measurement of the inferior vena cava during resuscitation in trauma patients. J Trauma. 2007;63:1245–8.CrossRefPubMed Yanagawa Y, Sakamoto T, Okada Y. Hypovolemic shock evaluated by sonographic measurement of the inferior vena cava during resuscitation in trauma patients. J Trauma. 2007;63:1245–8.CrossRefPubMed
10.
go back to reference Coen D, Cortellaro F, Pasini S, Tombini V, Vaccaro A, Montalbetti L, Cazzaniga M, Boghi D. Towards a less invasive approach to the early goal-directed treatment of septic shock in the ED. Am J Emerg Med. 2014;32:563–8.CrossRefPubMed Coen D, Cortellaro F, Pasini S, Tombini V, Vaccaro A, Montalbetti L, Cazzaniga M, Boghi D. Towards a less invasive approach to the early goal-directed treatment of septic shock in the ED. Am J Emerg Med. 2014;32:563–8.CrossRefPubMed
12.
go back to reference Sartelli M, Abu-Zidan FM, Ansaloni L, et al. The role of the open abdomen procedure in managing severe abdominal sepsis: WSES position paper. World J Emerg Surg. 2015;10:35.CrossRefPubMedPubMedCentral Sartelli M, Abu-Zidan FM, Ansaloni L, et al. The role of the open abdomen procedure in managing severe abdominal sepsis: WSES position paper. World J Emerg Surg. 2015;10:35.CrossRefPubMedPubMedCentral
13.
14.
go back to reference Weekes AJ, Tassone HM, Babcock A, Quirke DP, Norton HJ, Jayarama K, Tayal VS. Comparison of serial qualitative and quantitative assessments of caval index and left ventricular systolic function during early fluid resuscitation of hypotensive emergency department patients. Acad Emerg Med. 2011;18:912–21.CrossRefPubMed Weekes AJ, Tassone HM, Babcock A, Quirke DP, Norton HJ, Jayarama K, Tayal VS. Comparison of serial qualitative and quantitative assessments of caval index and left ventricular systolic function during early fluid resuscitation of hypotensive emergency department patients. Acad Emerg Med. 2011;18:912–21.CrossRefPubMed
15.
go back to reference Dipti A, Soucy Z, Surana A, Chandra S. Role of inferior vena cava diameter in assessment of volume status: a meta-analysis. Am J Emerg Med. 2012;30:1414–1419.e1.CrossRefPubMed Dipti A, Soucy Z, Surana A, Chandra S. Role of inferior vena cava diameter in assessment of volume status: a meta-analysis. Am J Emerg Med. 2012;30:1414–1419.e1.CrossRefPubMed
16.
go back to reference Ferrada P, Evans D, Wolfe L, Anand RJ, Vanguri P, Mayglothling J, Whelan J, Malhotra A, Goldberg S, Duane T, Aboutanos M, Ivatury RR. Findings of a randomized controlled trial using limited transthoracic echocardiogram (LTTE) as a hemodynamic monitoring tool in the trauma bay. J Trauma Acute Care Surg. 2014;76:31–7.CrossRefPubMed Ferrada P, Evans D, Wolfe L, Anand RJ, Vanguri P, Mayglothling J, Whelan J, Malhotra A, Goldberg S, Duane T, Aboutanos M, Ivatury RR. Findings of a randomized controlled trial using limited transthoracic echocardiogram (LTTE) as a hemodynamic monitoring tool in the trauma bay. J Trauma Acute Care Surg. 2014;76:31–7.CrossRefPubMed
17.
go back to reference Abu-Zidan FM, Idris K. Sonographic measurement of the IVC diameter as an indicator for fluid resuscitation: beware of the intra-abdominal pressure. World J Surg. 2015;39:2608–9.CrossRefPubMed Abu-Zidan FM, Idris K. Sonographic measurement of the IVC diameter as an indicator for fluid resuscitation: beware of the intra-abdominal pressure. World J Surg. 2015;39:2608–9.CrossRefPubMed
18.
go back to reference Abu-Zidan FM, Idris K, Khalifa M. Strangulated epigastric hernia in a 90-year-old man: Point-of-Care Ultrasound (POCUS) as a saving kit: case report. Int J Surg Case Rep. 2016;22:19–22.CrossRefPubMedPubMedCentral Abu-Zidan FM, Idris K, Khalifa M. Strangulated epigastric hernia in a 90-year-old man: Point-of-Care Ultrasound (POCUS) as a saving kit: case report. Int J Surg Case Rep. 2016;22:19–22.CrossRefPubMedPubMedCentral
Metadata
Title
On table POCUS assessment for the IVC following abdominal packing: how I do it
Author
Fikri M. Abu-Zidan
Publication date
01-12-2016
Publisher
BioMed Central
Published in
World Journal of Emergency Surgery / Issue 1/2016
Electronic ISSN: 1749-7922
DOI
https://doi.org/10.1186/s13017-016-0092-3

Other articles of this Issue 1/2016

World Journal of Emergency Surgery 1/2016 Go to the issue